MODEL: CTS2 CTS2 SPECIFICATIONS ES-1902 Rev.2 Page 1/4 http://www.m-system.co.jp/ Plug-in Signal Conditioners M-UNIT HIGH AC CURRENT TRANSMITTER (wide bandwidth) Functions & Features

  • Detecting high current at the flexible current probe and providing a porportional low-ripple standard signal appropriate for computer use
  • Wide frequency band can be accepted
  • Clipped around a conductor without disconnecting the conductor
  • Rogowski coil type
  • Isolation up to 2000 V AC
  • High-density mounting Typical Applications
  • Measurement in tight places as never before possible
  • Monitoring load current of motors employing inverters
  • Detecting failures of a pump or other device by monitoring abnormal load current of motors
  • Monitoring current of electric welding machine (1.97) 123 (4.84) (3.15) mm (inch) MODEL: CTS2–[1][2]–[3][4]

ORDERING INFORMATION

  • Code number: CTS2-[1][2]-[3][4] Specify a code from below for each [1] through [4]. (e.g. CTS2-AA-B/Q)
  • Special output range (For codes Z & 0)
  • Specify the specification for option code /Q (e.g. /C01/S01) Default Setting for input range:

30 A for 300 A rating

300 A for 3000 A rating

[1] INPUT Current A : 0 – 300 A AC (30, 60, 150 or 300 A selectable) B : 0 – 3000 A AC (300, 600, 1500 or 3000 A selectable) [2] OUTPUT Current A: 4 – 20 mA DC (Load resistance 750 Ω max.) B: 2 – 10 mA DC (Load resistance 1500 Ω max.) C: 1 – 5 mA DC (Load resistance 3000 Ω max.) D: 0 – 20 mA DC (Load resistance 750 Ω max.) E: 0 – 16 mA DC (Load resistance 900 Ω max.) F: 0 – 10 mA DC (Load resistance 1500 Ω max.) G: 0 – 1 mA DC (Load resistance 15 kΩ max.) Z: Specify current (See OUTPUT SPECIFICATIONS) Voltage 1: 0 – 10 mV DC (Load resistance 10 kΩ min.) 2: 0 – 100 mV DC (Load resistance 100 kΩ min.) 3: 0 – 1 V DC (Load resistance 100 Ω min.) 4: 0 – 10 V DC (Load resistance 1000 Ω min.) 5: 0 – 5 V DC (Load resistance 500 Ω min.) 6: 1 – 5 V DC (Load resistance 500 Ω min.) 4W: -10 – +10 V DC (Load resistance 2000 Ω min.) 5W: -5 – +5 V DC (Load resistance 1000 Ω min.) 0: Specify voltage (See OUTPUT SPECIFICATIONS) [3] POWER INPUT AC Power B: 100 V AC C: 110 V AC D: 115 V AC F: 120 V AC G: 200 V AC H: 220 V AC J: 240 V AC DC Power S: 12 V DC R: 24 V DC V: 48 V DC P: 110 V DC [4] OPTIONS blank: none /Q: With options (specify the specification) SPECIFICATIONS OF OPTION: Q (multiple selections) COATING (For the detail, refer to M-System's web site.) /C01: Silicone coating /C02: Polyurethane coating /C03: Rubber coating TERMINAL SCREW MATERIAL /S01: Stainless steel

MODEL: CTS2 CTS2 SPECIFICATIONS ES-1902 Rev.2 Page 2/4 http://www.m-system.co.jp/ GENERAL SPECIFICATIONS Construction Probe: Clip-around type Transmitter: Plug-in Connection Output & power: M3.5 screw terminals Input: Connector Screw terminal: Chromated steel (standard) or stainless steel Housing material Probe: TPE rubber, Polypropylene Transmitter: Flame-resistant resin (black) Isolation: Current input to sensor output or transmitter input or transmitter output to power Input waveform RMS sensing: Up to 15 % of 3rd harmonic content Overrange output: 0 to 120 % at 1 – 5 V Zero adjustment: -5 to +5 % (front) Span adjustment: 95 to 105 % (front) Input range: Selectable with the front DIP switch among 30, 60, 150 or 300 A, or 300, 600, 1500 or 3000 A INPUT SPECIFICATIONS Frequency: 4 Hz – 10 kHz (±3 dB) Max. operating voltage: 1000 V AC (primary side) Overload capacity: 1000 % of rating for 3 seconds, 200 % for 10 seconds, 120 % continuous Operational range: 0 – 120 % of rating 204 100 1k 10k (Hz) (dB) Frequency Characteristics OUTPUT SPECIFICATIONS ■ DC Current: 0 – 20 mA DC Minimum span: 1 mA Offset: Max. 1.5 times span Load resistance: Output drive 15 V max. ■ DC Voltage: -10 – +12 V DC Minimum span: 5 mV Offset: Max. 1.5 times span Load resistance: Output drive 10 mA max.; 5 mA for negative voltage output; at ≥ 0.5 V INSTALLATION Power input

  • AC: Operational voltage range: rating ±10 %, 50/60 ±2 Hz, approx. 2 VA
  • DC: Operational voltage range: rating ±10 %, or 85 – 150 V for 110 V rating (ripple 10 % p-p max.) approx. 2 W (80 mA at 24 V) Operating temperature Probe: -10 to +55°C (14 to 131°F) Transmitter: -5 to +60°C (23 to 140°F) Operating humidity: Probe: 15 to 85 % RH (non-condensing) Transmitter: 30 to 90 % RH (non-condensing) Mounting: Surface or DIN rail Weight Probe: 370 g (0.82 lb) Transmitter: 300 g (0.66 lb) PERFORMANCE in percentage of span Accuracy: ±1.5 % at 20 Hz – 1 kHz Repeatability: ±0.1 % Position sensitivity: ±1 % (In recommended mounting; otherwise the sensitivity may increase. Refer to the instruction manual.) Temp. coefficient: ±0.15 %/°C (±0.08 %/°F) Response time: Approx. 1.5 sec. (0 – 90 %) Ripple: 0.5 %p-p max. Line voltage effect: ±0.1 % over voltage range Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength: 2000 V AC @ 1 minute (Current input to sensor output or transmitter input or transmitter output to power to ground)

MODEL: CTS2 CTS2 SPECIFICATIONS ES-1902 Rev.2 Page 3/4 http://www.m-system.co.jp/ EXTERNAL VIEW Range Selector* 4 : 300 (3000) A 3 : 150 (1500) A 2 : 60 ( 600) A 1 : 30 ( 300) A Zero Adj. Span Adj. SENSOR INPUT ON Probe Connector *( ) for input 3000A type. EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch) ■ TRANSMITTER 3456 2187 80 (3.15) 80 (3.15) (.79) 35.4 (1.39) 40 (1.57) 50 (1.97) 7.8 (.31) CLAMP (top & bottom) DIN RAIL 35mm wide2-4.5 (.18) dia. MTG HOLE 15 (.59) deep 8-M3.5 SCREW When mounting, no extra space is needed between units. 13 (.51) Connector of Sensor Cable ■ SENSOR 190 (7.48) max. 9.9 dia. (.39) L 610 8 meters (26.4 ft) CONNECTOR 5 dia. (.20) R 60 (2.36) min. (minimum curvature radius)

MODEL: CTS2 CTS2 SPECIFICATIONS ES-1902 Rev.2 Page 4/4 http://www.m-system.co.jp/ SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM Base Socket SZ R.M.S. OperationIntegrationRange Selector Output Driver OUTPUT U(+) V(–) POWER SOURCE LOAD CT RANGE SELECTOR Specifications are subject to change without notice.