CTFC75-9 MULTICOMP | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 2

Technical content

Features

  • Single 115V primary winding
  • Double section imperial bobbin
  • 6 to 200VA power, 50/60Hz
  • Temperature class B (130°C)
  • Dielectric strength 3,750Vrms
  • Manufactured and tested in accordance with EN60950 and EN61558 Specifications Max. Winding Temperature : 55°C Overall Insulation Rating : >50MΩ (at 500V, 20°C) Flash Test (isolation test) : Primary/Secondary/Lamination 2.4KVrms Winding Wire : Polyurethane coated IEC317 Grade 1 Tape : 3M No 56 or 3M No 1350Y Thermosetting Core : 400/50 Finish : Ultimeg 3.72 Clear 6-50 VA L-Clamps 6-100VA 75 - 200VA Universal end frames 150-200VA VA Rating Reg % 2 A ±1 B ±1 C ±1 D ±1 E ±1 Weight 6 24 55 68 37 45 36 170g 12 16 74 90 50 60 45 390g 20 12 74 90 50 60 52 530g 25 10 83 97 5 69 53 675g 50 9 94 106 65 79 53 985g VA Rating Reg % 2 F ±1 G ±1 H ±1 I ±1 J ±1 K ±1 Weight 75 8 55 54 54 80 67 71 1,480g 100 10 45 57 57 89 75 65 1,550g 200 8 68 72 56 102 85 85 2,750g Dimensions : Millimetres Diagram

www.element14.com www.farnell.com www.newark.com www.cpc.co.uk Page <2> V1.025/08/22 Transformers Chassis Mounting Important Notice : This data sheet and its contents (the “Information”) belong to the members of the Premier Farnell group of companies (the “Group”) or are licensed to it. No licence is granted for the use of it other than for information purposes in connection with the products to which it relates. No licence of any intellectual property rights is granted. The Information is subject to change without notice and replaces all data sheets previously supplied. The Information supplied is believed to be accurate but the Group assumes no responsibility for its accuracy or completeness, any error in or omission from it or for any use made of it. Users of this data sheet should check for themselves the Information and the suitability of the products for their purpose and not make any assumptions based on information included or omitted. Liability for loss or damage resulting from any reliance on the Information or use of it (including liability resulting from negligence or where the Group was aware of the possibility of such loss or damage arising) is excluded. This will not operate to limit or restrict the Group’s liability for death or personal injury resulting from its negligence. pro - POWER is the registered trademark of the Group. © Premier Farnell plc 2012. Single Primary Part Number VA Output V AC CTFC6-4.5 4.5 CTFC6-6 6 CTFC6-9 9 CTFC6-12 12 CTFC6-15 15 CTFC12-9 CTFC12-12 12 CTFC12-15 15 CTFC12-20 20 CTFC12-24 24 Part Number VA Output V AC CTFC20-9 CTFC20-12 12 CTFC20-15 15 CTFC20-18 18 CTFC20-20 20 CTFC20-24 24 CTFC50-6 CTFC50-9 9 CTFC50-12 12 Part Number VA Output V AC CTFC50-15 CTFC50-18 18 CTFC50-24 24 CTFC75-9 CTFC75-20 20 CTFC100-9U 100 CTFC100-12U 12 CTFC100-20U 20 Description Part Number Transformer, 6VA 2 × 4.5V CTFC6-4.5 Transformer, 6VA, 2 × 6V CTFC6-6 Transformer, 6VA, 2 × 9V CTFC6-9 Transformer, 6VA, 2 × 12V CTFC6-12 Transformer, 6VA, 2 × 15V CTFC6-15 Transformer, 12VA, 2 × 9V CTFC12-9 Transformer, 12VA, 2 × 12V CTFC12-12 Transformer, 12VA, 2 × 15V CTFC12-15 Transformer, 12VA, 2 × 20V CTFC12-20 Transformer, 12VA, 2 × 24V CTFC12-24 Transformer, 20VA, 2 × 9V CTFC20-9 Transformer, 20VA, 2 × 12V CTFC20-12 Transformer, 20VA, 2 × 15V CTFC20-15 Transformer, 20VA, 2 × 18V CTFC20-18 Part Number Table Description Part Number Transformer, 20VA, 2 × 20V CTFC20-20 Transformer, 20VA, 2 × 24V CTFC20-24 Transformer, 50VA, 2 × 6V CTFC50-6 Transformer, 50VA, 2 × 9V CTFC50-9 Transformer, 50VA, 2 × 12V CTFC50-12 Transformer, 50VA, 2 × 15V CTFC50-15 Transformer, 50VA, 2 × 18V CTFC50-18 Transformer, 50VA, 2 × 24V CTFC50-24 Transformer, 75VA, 2 × 9V CTFC75-9 Transformer, 75VA, 2 × 20V CTFC75-20 Transformer, 100VA, 2 × 9V CTFC100-9U Transformer, 100VA, 2 × 12V CTFC100-12U Transformer, 100VA, 2 × 20V CTFC100-20U