CSW SENSATA | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 3
Technical content
Features
- Compact and Lightweight – The CSW provides pure sine wave power from a small footprint designed to fit in tight vehicle and marine spaces. And it is lightweight, so won’t weigh you down.
- At-a-Glance Status – The inverter’s status can be determined at a glance with the easy-to-read LED light.
- Digital Display* – The alphanumeric display shows the inverter’s battery voltage, total AC output power, along with additional operation codes. (*not available on the CSW412)
- USB Port – Power and charge your USB-enabled device with the available USB port.
- GFCI AC Outlet – Plug in two pieces of equipment directly to the CSW and know that the GFCI outlet will quickly stop the flow of electricity should a ground fault occur. The outlet also comes with an LED indicator and test/reset capability.
- Automatic Transfer Switch Option – The CSW2012-X automatically switches between shore power and inverter/battery power. Options
- Remote Switch – Use the optional CSW-RS remote switch for even easier on/off access away from the inverter. The CSW-RS comes with a 20’ cable.
- Transfer Switch – Use the optional 15 amp CSW-TS15 transfer switch to automatically switch AC load connections between utility/generator power and the AC output of the CSW1012 inverter. Introduction The CSW Series Inverter is a pure sine wave inverter designed to be powerful, yet simple to operate. The CSW will provide you with reliable AC power for troublefree use. Model Numbers
- CSW412
- CSW1012
- CSW2012
- CSW2012-X Available For
- Emergency Medical Services
- Marine Systems
- Military Vehicles
- RV Systems
- Trucks
- Utility Vehicles Available Accessories
- Remote Switch [CSW-RS]
- Transfer Switch [CSW-TS15] Pure Sine Wave 12 400-
2000 VABattery Voltage Options Continuous Output Options
Copyright © 2019 Sensata Technologies, Inc. www.sensata.com SPECIFICATIONS CSW412 CSW1012 CSW2012 CSW2012-X INVERTER SPECIFICATIONS - OUTPUT Continuous power at nominal DC voltage 400 watts 1000 watts 2000 watts 2000 watts Peak surge power 800 watts 2000 watts 4000 watts 4000 watts 10 sec surge power 400 - 550 watts 1000 - 1500 watts 2000-3000 watts 2000-3000 watts 1 sec surge power 550-800 watts 1500 - 2000 watts 3000-4000 watts 3000-4000 watts 200 msec surge power > 800 watts > 2000 watts > 4000 watts > 4000 watts AC output voltage at 12.5 VDC 120 VAC ± 5% 120 VAC ± 5% 120 VAC ± 5% 120 VAC ± 5% AC ouput current 3.3 AAC 8.3 AAC 16.6 AAC 16.6 AAC AC output voltage range 104 - 127 VAC 104 - 127 VAC 104 - 127 VAC 104 - 127 VAC AC output frequency 60 Hz ± 0.5 Hz 60 Hz ± 0.5 Hz 60 Hz ± 0.5 Hz 60 Hz ± 0.5 Hz AC output waveform Pure sine wave Pure sine wave Pure sine wave Pure sine wave Total harmonic distortion [THD] < 3% < 3% < 3% < 3% Transfer Time NA NA NA < 30 ms USB 5 V, 750 mA 5 V, 750 mA 5V, 2.1 A 5V, 2.1 A INVERTER SPECIFICATIONS - INPUT Nominal DC input voltage 12.5 VDC 12.5 VDC 12.5 VDC 12.5 VDC Input current 38 DCA 94 DCA 187 DCA 193 DCA No load draw < 0.8 ADC < 1.2 ADC < 1.2 ADC < 1.5 ADC Optimum efficiency > 90% > 90% > 90% > 90% High voltage shutdown 15.5 VDC 15.5 VDC 15.5 VDC 15.5 VDC Low voltage alarm 11.0 VDC, audible 11.2 VDC, audible 11.2 VDC, audible 11.2 VDC, audible Low voltage shutdown 10.5 VDC 10.5 VDC, Recover at 11.8 VDC 10.5 VDC 10.5 VDC GENERAL FEATURES AND CAPABILITIES Transfer relay capability NA NA NA 30 AAC Display status indictator LED: Power, Fault Green, amber, red LED: Status LED: Status, Display Digital display None Input voltage/current, output power Input voltage, output power, warning, and error code Input voltage, output power, warning, and error code AC receptacles NEMA 5-15 [GFCI] NEMA 5-15 [GFCI] NEMA 5-20 [GFCI] NEMA 5-20 [GFCI] Listings Conforms to UL458, Certified to CSA C22.2 No. 107.1, meets FCC Class B Warranty One year One year One year One year
InverterInfo@sensata.com Power Conversion www.magnum-dimensions.com Page 3 Rev: 07/20/19 Part#64-0665 vC Copyright © 2019 Sensata Technologies, Inc. Sensata Technologies, Inc. (“Sensata”) data sheets are solely intended to assist designers (“Buyers”) who are developing systems that incorporate Sensata products (also referred to herein as “components”). Buyer understands and agrees that Buyer remains responsible for using its independent analysis, evaluation and judgment in designing Buyer’s systems and products. Sensata data sheets have been created using standard laboratory conditions and engineering practices. Sensata has not conducted any testing other than that specifically described in the published documentation for a particular data sheet. Sensata may make corrections, enhancements, improvements and other changes to its data sheets or components without notice. Buyers are authorized to use Sensata data sheets with the Sensata component(s) identified in each particular data sheet. HOWEVER, NO OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE TO ANY OTHER SENSATA INTELLECTUAL PROPERTY RIGHT, AND NO LICENSE TO ANY THIRD PARTY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT, IS GRANTED HEREIN. SENSATA DATA SHEETS ARE PROVIDED “AS IS”. SENSATA MAKES NO WARRANTIES OR REPRESENTATIONS WITH REGARD TO THE DATA SHEETS OR USE OF THE DATA SHEETS, EXPRESS, IMPLIED OR STATUTORY , INCLUDING ACCURACY OR COMPLETENESS. SENSATA DISCLAIMS ANY WARRANTY OF TITLE AND ANY IMPLIED WARRANTIES OF MERCHANTABILITY , FITNESS FOR A PARTICULAR PURPOSE, QUIET ENJOYMENT, QUIET POSSESSION, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL PROPERTY RIGHTS WITH REGARD TO SENSATA DATA SHEETS OR USE THEREOF. All products are sold subject to Sensata’s terms and conditions of sale supplied at www.sensata.com SENSATA ASSUMES NO LIABILITY FOR APPLICATIONS ASSISTANCE OR THE DESIGN OF BUYERS’ PRODUCTS. BUYER ACKNOWLEDGES AND AGREES THAT IT IS SOLELY RESPONSIBLE FOR COMPLIANCE WITH ALL LEGAL, REGULATORY AND SAFETY-RELATED REQUIREMENTS CONCERNING ITS PRODUCTS, AND ANY USE OF SENSATA COMPONENTS IN ITS APPLICATIONS, NOTWITHSTANDING ANY APPLICATIONS-RELATED INFORMATION OR SUPPORT THAT MAY BE PROVIDED BY SENSATA. Mailing Address: Sensata Technologies, Inc., 529 Pleasant Street, Attleboro, MA 02703, USA. www.sensata.com PHYSICAL SPECIFICATIONS Dimensions (L x W x H) 6.9” x 7.9” x 3.4” [17.5cm x 20.1cm x 8.6cm] [32.1cm x 17.8cm x 8.9cm] [41.4cm x 23.1cm x 10.9cm] 17” x 9” x 4.5” [43.2cm x 22.9cm x 11.4cm] Shipping dimensions (L x W x H) 7.9” x 6.9” x 3.5” [20.1cm x 17.5cm x 8.9cm] [39.2cm x 22.3cm x 14.3cm] 19” x 11.3” x 6.7” [48.3cm x 28.7cm x 17cm] 19” x 11.3” x 6.7” [48.3cm x 28.7cm x 17cm] Mounting Shelf [top or bottom up] or bulkhead Operating temperature -0°C to +40°C [32°F to 104°F] Nonoperating temperature -20°C to +60°C [-4°F to 140°F] Operating humidity 0 to 90% RH non condensing Max operating altitude 9843’ [3000 m] above sea level AGENCY APPROVALS & CERTIFICATIONS
- Conforms to UL458, Certified to CSA C22.2 No. 107.1, meets FCC Class B Testing for specifications at 25°C. Specifications subject to change without notice. GENERAL NOTES