Banner’s LED Strip Lights have sturdy aluminum housings, shatterproof windows, and impressive environmental ratings, making them an ideal general-purpose LED light for machine, enclosure, or other industrial lighting applications.

  • Low-profile, space-saving design
  • Rugged, water-resistant IP69K option
  • Available in eight lengths from 145 mm to 1130 mm
  • Lensed models or choice of clear or diffuse window
  • Daisy chain power to multiple lights
  • Optional snap clips for easy installation and repositioning
  • Capability to dim lights using the wiring pinout (Hi/Lo/Off)
  • Models with Hi/Lo/Off switch available
  • Automatic temperature protection built into the unit. Above °C, the light dims to manage heat and protect product lifetime
  • Motion sensing models available Note: When cascading lights, a model with an Hi/Lo/Off switch can be used to control the lights cascaded off the switched model. Stand-Alone Light—cable Stand-Alone Light or End Light in a Cascade—QD First Light in a Cascade—cable First or Middle of a Cascade—QD WLS28-2 Work Light Strips are available as either stand-alone models, or as cascade models that can be "daisy-chained" together for a continuous length of lighting, with a minimum of wiring. Stand-alone models have cable or male QD fitting at one end for power connection, no connections at opposite end. A stand-alone model may be used as the last in the cascade series. Cascade models have cable or male QD fitting at one end for power connection, female QD fitting at opposite end for connection to other lights in the cascade. Cascade models with cable end can only be used as the first light in the cascade series. A double-ended accessory cordset must be used between each pair of lights in a cascade. Important: Lea el siguiente instructivo antes de operar el luminario. Por favor descargue desde www.bannerengineering.com toda la documentación técnica de los WLS28-2 LED Strip Light, disponibles en múltiples idiomas, para detalles del uso adecuado, aplicaciones, advertencias, y las instrucciones de instalación de estos dispositivos. Important: Lisez les instructions suivantes avant d'utiliser le luminaire. Veuillez télécharger la documentation technique complète des WLS28-2 LED Strip Light sur notre site www.bannerengineering.com pour les détails sur leur utilisation correcte, les applications, les notes de sécurité et les instructions de montage. Models WLS28-2 ConnectorConstructionWindow Lighted Length (mm)LED ColorCascadableFamily C = Cascadable X = Non-cascadable W = Cool white WW = Warm white R = Red G = Green B = Blue Y = Yellow 145 285 430 570 710 850 990 1130 Blank = Clear plastic D = Diffused plastic L25 = 25 deg lensed window X = Not sealed S = Sealed † * Requires a mating cordset † Sealed models not available with Hi/Lo/Off or motion switch Blank = None M = Motion Switch PB = High/Lo/Off Switch Blank = 2 m integral cable Q = Integral 4-pin M12 QD* C W 145 D X Q Control WLS28-2 LED Strip Light Original Document 175008 Rev. J

27 August 2019

Table 1: IP50 Models Non-Switch Models HIGH/OFF/LOW Switch Models Motion Switch Models Lighted Length Power Connector Stand-Alone Cascade Stand-Alone Cascade Stand-Alone Cascade WLS28-2XW145X WLS28-2CW145X WLS28-2XW145XPB WLS28-2CW145XPB WLS28-2XW145XM WLS28-2CW145XM 145 mm 2 m (6.5 ft) cable WLS28-2XW285X WLS28-2CW285X WLS28-2XW285XPB WLS28-2CW285XPB WLS28-2XW285XM WLS28-2CW285XM 285 mm WLS28-2XW430X WLS28-2CW430X WLS28-2XW430XPB WLS28-2CW430XPB WLS28-2XW430XM WLS28-2CW430XM 430 mm WLS28-2XW570X WLS28-2CW570X WLS28-2XW570XPB WLS28-2CW570XPB WLS28-2XW570XM WLS28-2CW570XM 570 mm WLS28-2XW710X WLS28-2CW710X WLS28-2XW710XPB WLS28-2CW710XPB WLS28-2XW710XM WLS28-2CW710XM 710 mm WLS28-2XW850X WLS28-2CW850X WLS28-2XW850XPB WLS28-2CW850XPB WLS28-2XW850XM WLS28-2CW850XM 850 mm WLS28-2XW990X WLS28-2CW990X WLS28-2XW990XPB WLS28-2CW990XPB WLS28-2XW990XM WLS28-2CW990XM 990 mm WLS28-2XW1130X WLS28-2CW1130X WLS28-2XW1130XPB WLS28-2CW1130XPB WLS28-2XW1130XM WLS28-2CW1130XM 1130 mm Integral 2 m (6.5 ft) unterminated cable models are listed. To order the 4-pin M12/Euro-style integral quick disconnect model, add the suffix "Q" to the model number. For example, WLS28-2XW285XQ. Table 2: IP67/IP69K Models Model Lighted Length Connector Stand-Alone Cascade WLS28-2XW145S WLS28-2CW145S 145 mm 2 m (6.5 ft) cable WLS28-2XW285S WLS28-2CW285S 285 mm WLS28-2XW430S WLS28-2CW430S 430 mm WLS28-2XW570S WLS28-2CW570S 570 mm WLS28-2XW710S WLS28-2CW710S 710 mm WLS28-2XW850S WLS28-2CW850S 850 mm WLS28-2XW990S WLS28-2CW990S 990 mm WLS28-2XW1130S WLS28-2CW1130S 1130 mm Integral 2 m (6.5 ft) unterminated cable models are listed. To order the 4-pin M12/Euro-style integral quick disconnect model, add the suffix "Q" to the model number. For example, WLS28-2XW285SQ. Wiring Diagram Male Female Pin Wire Color Connection

1 Brown 12 V dc to 30 V dc

3 Blue dc common

4 Black

Models without motion detection: Connect to 12 V dc to 30 V dc for 50% maximum intensity. For maximum intensity, leave the black wire floating or connected to common. Models with motion detection: Connect to 12 V dc to 30 V dc to bypass the motion detector switch

2 White Not used

Specifications Supply Voltage and Current

12 V dc to 30 V dc

Use only with suitable Class 2 power supply (UL) or a SELV power supply (CE). Supply Protection Circuitry Protected against reverse polarity and transient voltages Light Characteristics Cool white Color Temperature (CCT): 6500K (+500K, -400K) Lumen output: 800 (± 5%) per foot, typical at 25 °C (77 °F) Luminous efficacy: 110 lumens/Watt typical at 24 V dc at 25 °C (77 °F) CRI: 85, typical Warm white: 3000K (+200K, -100K) Green: 525 nm Red: 618 nm Yellow: 590 nm Blue: 460 nm Connections Integral 4-pin M12/Euro-style quick disconnect (4-pin connecting cordset required); or 2 m (6.5 ft) integral PVC cable Environmental Rating IEC IP50 (non-sealed models) or IEC IP65, IEC IP67, IP69K per DIN 40050-9 (sealed models) Vibration and Mechanical Shock Vibration 10-55 Hz 1.0 mm p-p amplitude per IEC 60068-2-6 Shock 15G 11 ms duration, half sine wave per IEC 60068-2-27 Operating Temperature Models without motion detection:–40 °C to +70 °C (–40 °F to +158 °F) Models with motion detection: –20 °C to +60 °C (–4 °F to +140 °F) Light output begins to decrease above 50 °C (122 °F) and will be approximately 65% of max intensity at 60 °C (140 °F) and 30% of max intensity at 70 °C (158 °F) Storage Temperature WLS28-2 LED Strip Light 2 www.bannerengineering.com - Tel: + 1 888 373 6767 P/N 175008 Rev. J

Lumen Maintenance = L70 When operating within specifications, output will decrease less than 30% after 75,000 hours. Push Button II = 100% light intensity I = 50% light intensity 0 = Off Models with Motion Detection Light turns off after approximately 60 seconds without detecting motion Range: 12 meters; ± 45° field of view Standby current: 170 µA Construction Clear anodized aluminum housing; painted zinc end caps; polycarbonate window on clear and diffuse plastic models; acrylic window on L25 models; zinc plated steel brackets Mounting (2) swivel brackets SMBWLS28RA included and (4) screws Certifications D Sealed models only Application Note When connecting cascadable lights in series at 100% intensity, it is important not to exceed maximum current limitations: Maximum length of light at 12 V dc: 1.4 m (4.6 ft) Maximum length of light at 24 V dc: 3.0 m (9.8 ft) Maximum length of light at 30 V dc: 3.1 m (10.2 ft) At 50% intensity, double the lengths. Note: Do not spray cable with high-pressure sprayer, or cable damage will result. Table 3: Typical Current Light Length Typical Current Max. Current Lumens 1 (Typical @25 °C)

12 V dc 24 V dc 30 V dc A Cool White Warm White Green Red Yellow Blue

145 mm 0.33 A 0.15 A 0.12 A 0.4 400 400 180 55 50 40 285 mm 0.66 A 0.30 A 0.24 A 0.8 800 800 360 110 100 80 430 mm 1.01 A 0.46 A 0.36 A 1.2 1200 1200 540 165 150 120 570 mm 1.36 A 0.61 A 0.48 A 1.6 1600 1600 720 220 200 160 710 mm 1.75 A 0.77 A 0.60 A 2.0 2000 2000 900 275 250 200 850 mm 2.13 A 0.92 A 0.73 A 2.4 2400 2400 1080 330 300 240 990 mm 2.59 A 1.08 A 0.85 A 2.8 2800 2800 1260 385 350 280 1130 mm 3.04 A 1.24 A 0.97 A 3.2 3200 3200 1440 440 400 320 Dimensions 36.9 [1.45] 21.0 [.83] 13.5 [.53] 20.8 [.82] Motion Detector Models ON/OFF Switch Models L25 Models 20.8 [.82] [.55] 32.2 [1.27] [1.10] [.83] 13.5 [.53] 28 [1.10] 7.5 [.30] 4 X M3 X .50 ISOø 14.7 [.58] [.31] 9.5 [.37] 19 [.75] 30 [1.18] ø 5 [.20] 31.5 [1.24] 10.5 [.41] [1.18] Dimensions are shown with the included SMBWLS28RA bracket. Non-Switch Models IP50 Models IP67/IP69K Models L1 L2 L3 L4 1 Lumen values lowered by 25% on diffused window and 25 degree lensed models. WLS28-2 LED Strip Light P/N 175008 Rev. J www.bannerengineering.com - Tel: + 1 888 373 6767 3

4-Pin Threaded M12/Euro-Style Cordsets—Single Ended Model Length Style Dimensions Pinout (Female) MQDC-406RA 1.83 m (6 ft) Right-Angle 32 Typ. [1.26"] 30 Typ. [1.18"] ø 14.5 [0.57"] M12 x 1 MQDC-415RA 4.57 m (15 ft) MQDC-430RA 9.14 m (30 ft) MQDC-450RA 15.2 m (50 ft) 4-Pin Threaded M12/Euro-Style Cordsets—Double Ended Model Length Style Dimensions Pinout MQDEC-401SS 0.31 m (1 ft) Male Straight/Female Straight 40 Typ. [1.58"] ø 14.5 [0.57"] M12 x 1 44 Typ. [1.73"] ø 14.5 [0.57"] M12 x 1 Female Male 1 = Brown 2 = White 3 = Blue 4 = Black MQDEC-403SS 0.91 m (3 ft) MQDEC-406SS 1.83 m (6 ft) MQDEC-412SS 3.66 m (12 ft) MQDEC-420SS 6.10 m (20 ft) MQDEC-430SS 9.14 m (30 ft) MQDEC-450SS 15.2 m (50 ft) 4-Pin Threaded M12/Euro-Style Splitter Cordsets—Flat Junction Model Branches (Female) Trunk (Male) Pinout CSB-M1240M1240 No branch No trunk Female Male 1 = Brown 2 = White 3 = Blue 4 = Black CSB-M1240M1241 2 x 0.30 m (1 ft) No trunk CSB-M1241M1241 0.30 m (1 ft) CSB-M1248M1241 2.50 m (8 ft) CSB-M12415M1241 4.57 m (15 ft) CSB-M12425M1241 7.60 m (25 ft) CSB-UNT425M1241 7.60 m (25 ft) Unterminated 44 Typ. [1.73"] 43.0 [1.69"] Ø14.5 [0.57"] M12 x 1 Ø14.5 [0.57"] 40 Typ. [1.58"] 18.0 [0.71"] Ø4.5 [0.18"] 35 [1.38"] M12 x 1 WLS28-2 LED Strip Light 10 www.bannerengineering.com - Tel: + 1 888 373 6767 P/N 175008 Rev. J

The bracket kit is available as a replacement for the one that comes with the Work Light Strip. The kit contains two end brackets and four screws. SMBWLS28SM This kit allows the light to be mounted at a right angle to the mounting surface. The kit contains two end brackets and four screws. SMBWLS28SP

  • Stainless steel snap bracket kit
  • Includes two brackets SMH1316 This kit allows the light to be mounted to a 13/16-inch Unistrut channel. The kit includes:
  • #10-32 spring nuts (qty 2)
  • #10-32 socket head cap screws (qty 2)
  • #10 lock washers (qty 2) SMBWLSMAG Magnetic mounting bracket for easy attachment to steel surfaces SMBWLSMAGR Protective cover also available to prevent scratches to painted surfaces Banner Engineering Corp. Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product. THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE. This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at any time. Specifications and product information in English supersede that which is provided in any other language. For the most recent version of any documentation, refer to: www.bannerengineering.com. For patent information, see www.bannerengineering.com/patents. FCC Part 15 and CAN ICES-3 (B)/NMB-3(B) This device complies with part 15 of the FCC Rules and CAN ICES-3 (B)/NMB-3(B). Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules and CAN ICES-3 (B)/NMB-3(B). These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the manufacturer. WLS28-2 LED Strip Light © Banner Engineering Corp. All rights reserved