CS241DM CAMPBELL | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 3
Technical content
/ PRODUCT Il CAMPBELL ( SCIENTIFIC WHEN MEASUREMENTS MATTER o eet= (o= C5241DM Pt-1000 Class A, Precision Back-of-Module Temperature Sensor i Overview The C5241DM is a surface-mountable, back-of-module temperature sensor with features designed for bifacial photovoltaic (PV) module performance assessment and soiling. The probe head has been redesigned for easier installation. The measurement performance has been improved with a smaller footprint that is optimized to reduce back-of-module shading and eliminate surface cooling. Other improvements include greater sensor-to-module bonding/adhesion and a Benefits and Features ) Digital Modbus output ) Redesigned for optimal performance on bifacial PV module ) Easy installation with maximum sensor-to-module bonding strength and smaller profile ) NiST-traceable, serialized calibration certificate supplied with every sensor ) Meets or exceeds [EC 61724 Class A performance specifications ) Precision Pt-1000 Class A sensing element ) Compliant with IEC 60751, DIN EN 60751 (according to IEC 751) Detailed Description The C5241DM provides PV stakeholders with the most accurate with Digital Modbus RS-485 Output Digital Modbus \\ Smart Sensor / With rugged, surface-mountable / PRT thinner Teflon cable with a higher temperature rating. To meet the requirements of performance validation, every CS241DM is supplied with a NIST-traceable, serialized calibration certificate. This best-in-class smart sensor is a digital Modbus version of the C5241 Pt-1000 Class A, Back-of-Module Temperature Sensor. ) IP68 rating, making the sensor suitable for use on floating PV arrays ) Slim design to minimize sensor impact on bifaciality (<2% of full-size cell area) ) Thermal conductance greater than 600 W/(m?*K) ) Maximum sensor-to-module bonding ) High temperature rating to 150°C ) Internal four-wire measurement with 24-bit A/D and precision resistor to maximize measurement accuracy ) Quick sensor head connection for easier installation and replacement back-of-module temperature, even at long cable lengths, for For comprehensive details, visit: www.campbellscicom/cs241dm ‘
use in power assessment and soiling of solar PV modules. Back- of-module temperature is critical for the evaluation of effective irradiance, soiling, and power conversion, making the sensor that can collect this data a vital part of any PV performance monitoring system. The C5241DM consists of a Pt-1000 Class A platinum resistance thermometer (PRT) encased in a specially designed, slim- profile, low-mass aluminum disk. The slim design minimizes sensor impact on bifaciality with less than two percent area coverage on a full-sized cell. The disk shields the PRT from rapid temperature fluctuations while protecting the fragile PRT element during installation. It minimizes heat transfer, which eliminates surface cooling and results in the highest efficiency in measuring true temperature of the solar module. The disk adhesive has excellent thermal properties including a thermal conductance greater than 600 W/(m?*K), and it is extremely strong. This eliminates the need for high-temperature epoxy or tape for maximum sensor-to-module bonding, making the installation much easier. Specifications Measurement Uncertainty +0.3°C Surge Protection 1200 Visolation Supply Voltage 51030 Vdc Power Draw 15mA Operating Temperature ~ -40°to +150°C Range Shipping Dimensions 5x11.13x6.05 cm (6.75 x 4.38 x2.38in) Shipping Weight 907g(021b) Sensor Sensor Precision 1000 ohm Class A platinum sensing element (Pt-1000) Class A PRT Accuracy +(0.15 4+ 0.002T)°C Temperature Coefficient TCR = 3850 ppm/K Long-Term Stability Maximum R, drift 0.04% (after 1000 hat 400°C) Disk Material Anodized aluminum Disk Diameter 254cm (1.0in) Height 0419.cm (0.1651in.) Weight ~27 g (0.06 Ib) with connector and 1'm (3 ft) cable The C5241DM cable has been upgraded to a thin polytetrafluoroethylene (PTFE) Teflon-jacketed cable. This has two distinct advantages: 1. The thin diameter is small enough to fit between the cells of a bifacial module, eliminating any module shading due to cabling. 2. The Teflon jacket allows for a higher maximum temperature rating of 150°C. The cable includes a quick sensor head connection that is 0.91 m (3 ft) from the sensor head to allow for easier installation and sensor head replacement. Combining the highest-quality components and thoughtful, coherent C5241DM sensor design results in the highest back- of-module temperature-sensor performance. The CS241DM sensor meets or exceeds the thermal properties, accuracy, and uncertainty specifications defined by IEC 61724 for Class A performance and is compliant with IEC 60751, DINEN 60751 (according to IEC 751). Every CS241DM includes a NIST-traceable, serialized calibration; alcohol swab; and zip ties that clip to the edge of a module frame. IP Rating IP68 rating (self certified): 1 m submersion for 90 min Compliant with [EC 60751, DIN EN 60751, Industrial Design (IEC Class 4) (according to IEC 751) Industry Approvals Communications Protocol Modbus RTU protocol (over RS-485) Format 8 data bits, 1 stop bit, even parity as default (user-configurable) Baud Rate 19,200 bps as default (user- configurable) Modbus ID Last two digits of serial number as default (user-configurable) Cable (Sensor Head to DM Board) Jacket Material White semi-gloss PFA insulated (Teflon) -75°10 +250°C 6 mm (0.25 in.) at least 6 mm (0.25 in.) away from sensor disk 0216 cm (00851in.) 09144 m (31 Jacket Rating Minimum Bend Radius Cable Diameter Cable Length a For comprehensive details, visit: www.campbellscicom/cs241dm
Cable (DM Board to PT) Maximum Temperature Rating Minimum Temperature Rating Conductor Material Cable Type Jacket Material Insulation Material Dielectric Strength Approvals SCIENTIFIC 75°Cand 80°C (jacket 105°C; oil 75°0) -40°C 22 AWG 19/0.0058 stranded tinned copper 4 twisted pairs twisted together and wrapped with clear polyester tape to form a cable core Thermoplastic elastomer, 1.07 mm (0.042 in.) nominal wall thickness (pressure) High-density polyethylene 0.254 mm (007 in) nominal wall thickness
2000 VRMS
UL AWM 2463 (80C 600V) Overall Cable Diameter Compliance EMC Compliance RoHS2 POE Compliant CATse NEC (UL) TYPE PLTC NEC (UL) TYPE CMX OUTDOOR - M CECC(UL) TYPE CMX OUTDOOR PENNSYLVANIA D.EP. - MSHA 7.37 mm nominal +0.13 mm (0.29 in.nominal +0.005 in)) Conforms with Electromagnetic Compatibility Directive (EMQ). Conforms with the Restriction of Hazardous Substances Directive (RoHS2). POE compliant (802.3af) to 100 meters when installed per recommendations in TIATSB-184. Cable will meet CATSe channel requirements to 100 meter length. a For comprehensive details, visit: www.campbellscicom/cs241dm CAMPBELL Campbell Scientific, Inc. | 815W1800N | Logan, UT84321-1784 | (435)227-9120 | www.campbellscicom AUSTRALIA | BRAZIL | CANADA | CHINA | COSTA RICA | FRANCE | GERMANY | INDIA | SOUTH AFRICA | SPAIN | THAILAND | UK | USA ©2022 Campbell Sclentific,Inc. | 05/04/2022