CS231-L CAMPBELL | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 2

Technical content

5] SCIENTIFIC \\_/ WHEN MEASUREMENTS MATTER D Overview The C5231 offers the same precise temperature profiling as our 5230 SDI-12 Temperature Profiler, but with a slimmer design for easier use in borehole and road applications. The (CS231 requires a smaller installation hole when compared to the C5230. For road applications, this means easier drilling, as well as less time and material to backfill. The C5231 SDI-12 Temperature Profiler uses SDI-12 digital technology for simple integration. SDI-12 does away with analog measurement inaccuracies and susceptibility to electrical noise. The C5231 consists of a rigid probe assembly and up to four optional external temperature probes. The rigid probe assembly maintains the precise position of the Benefits and Features ) Lifetime min/max temperature recording ) User-resettable min/max temperature recording Technical Description When power is supplied to the CS231 probe, the internal electronics continuously measure the temperature at an approximate rate of one measurement per second. Every output measurement obtained from the sensor is a running average of 10 consecutive one-second readings. The accuracy specification is based on an average of 10 consecutive readings. For this reason, after the initial power PRODU( WEE(EEE €s231-L SDI-12 Temperature Profiler Customizable Rugged, digital temperature measurements temperature points within the profile, while protecting the temperature sensors in all mediums for the long term. The CS231 is suited for a wide variety of applications and environments. The completely sealed probe assembly and external probes permit the CS231 to be used in roadbeds, soils, and water (snow and ice). Applications where the C5231 is used include spring load adjustment, frost and permafrost monitoring, soil, and water or snowpack temperature profiling. ) Automatic one-second temperature update up, itis recommended to delay 10 seconds to obtain the best accuracy. Because the sensor is obtaining a measurement every one second, it is recommended to use the Continuous measurement command to obtain the temperature readings. Using th: commands will reduce the time taken to obtain a reading with the SDI-12 protocol. g For comprehensive details, visit: www.campbellsci.eu/cs231-|

-55°10 +85°C +0.2°C (at 40° to +85°C) +04°C (at 40°to +85°C) 00078°C SDI-12 9to28Vdc 10s 4 maximum Cable Insulation Minimum Spacing Maximum Length Probe Diameter Maximum Cable Length Standard External Probe Length Polypropylene Pro-Fax 8623, 105°C 5cm(1.97in) 30m(118in) 2.13cm (0.84in) 152 m (500 ft) 45cm(18in) Current Consumption Quiescent Current Drain Active Current Drain 1.0 mA (maximum per sensor) 20 mA + (number of sensors * 10mA) ol For comprehensive details, visit: www.campbellsci.eu/cs231-1 CAMPBELL 80Hathern Road, Shepshed, LE129GX UK | +(0)1509 828888 | sale@campbellsci.co.uk | www.campbellsci.eu SCIENTIFIC AUSTRALIA | BRAZIL | CANADA | CHINA | COSTA RICA | FRANCE | GERMANY | INDIA | SOUTH AFRICA | SPAIN | THAILAND | UK | USA ©2022 Campbell Scientific, Ltd. | 07/19/2022