Technical content
© Coilcraft, Inc. 2009 Specifications subject to change without notice. Please check our website for latest information. 50/60 Hz Current Sensing Transformer Document 150 Document 150 Revised 12/29/09 This Coilcraft current sense transformer is intended for use in measuring 50/60 Hz line currents from 0.5 to 20 Amperes rms. Typical application shown below yields an output of 0.1 Volt per Ampere. The sensitivity may be changed by adjusting the value of the terminating resistance (R T). These parts also can be used to mea- sure 400 Hz line currents. To request free evaluation samples, contact Coilcraft or visit www.coilcraft.com. RT VoutCS2106 Iin Weight: 19 g Terminations: Tin-silver over copper Packaging: 30 per tray Typical Circuit Frequency Sensed R T for Part Turns (N) Inductance 1 DCR max (Ohms) range2 current 1.0 V out number pri : sec min (mH) 1,2 – 3,4 8 – 5 (Hz) range Iin from 10 A Iin3 CS2106L 1 : 500 75 0.007 26 50 – 400 0.5 A – 20 A 68 Ohms 1. Inductance is for the secondary, tested at 1 kHz, 0.1 Vrms. 2. Square wave response deteriorates above and below this frequency. 3. Varying terminating resistance increases or decreases output Voltage/Ampere in approximate proportion to the ratio RT / 68. 4. Operating temperature range –40°C to +85°C. 5. Electrical specifications at 25°C. 0.5 1.0 1.5 2.0 Vout (Volts rms) 0 5 10 15 20 Current (Amperes rms) Typical Response (with RT = 68 Ohms)