CS100 CAMPBELL | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 2

Technical content

5] SCIENTIFIC WHEN MEASUREMENTS MATTER Overview The CS100 measures barometric pressure for the range of 600 to 1100 mb. This range equates to from below sea level (asinamine) up to 12,000 feet above sea level. Designed for Benefits and Features ) Optimized to mount in Campbell Scientific enclosures ) Low power consumption ) Three-year warranty Technical Description The CS100 is a Campbell Scientific version of Setra's model 278 barometer. It uses Setra's Setraceram capacitive sensor and IC analog circuit to measure barometric pressure. Specifications Measurement Description Barometric pressure Signal Type/Output Analog voltage -NOTE- 1hPa=1mbBar Pressure Range 600 to 1100 hPa Long-Term Stability +0.1 hPa per year Response Time <100 ms W R(REE cs100 Barometric Pressure Sensor Standard Barometer Resides inside weather proof enclosure use in environmental applications, the CS100 is compatible with all Campbell Scientific dataloggers. ) 500to 1100 hPa (mBar) and 800 to 1100 hPa (mBar) versions also available by special order—contact Campbell Scientific ) Integral switching circuit limits power consumption to measurement cycle The CS100 is encased in a stainless steel and polyester case fitted with an 1/8 in. barbed fitting for pressure connection. It includes an internal switching circuit that allows the datalogger to power the barometer only during measurement, which reduces power consumption. Resolution +001hPa Excitation 9.5 10 28 Vdc Elevation ~609.6 m (2,000 ft) below sea level (as in a mine) to 3657.6 m (12,000 ft) above sea level Accuracy +1.5 hPa (@ -20° to +50°C) For comprehensive details, visit: www.campbellsci.eu/cs100 ‘

Accuracy refers to the root External Trigger Voltage 3 to 28 Vdc (operating mode) sum squared (RSS) of end 0 Vdc (sleep mode) point non-linearity, hysteresis, repeatability, and calibration Current Consumption <3 mA (active) <1 pA (sleep mode) uncertainty. +0.5 hPa (@ +20°C) Temperature Range -40°to +60°C #10hPa (@070 40°C) Cable Diameter 0.8cm (0.31in) inearity =04 hPa Cable Length 08m(25ft) Hysteresis 0050 Dimensions 91X6.1X25Cm (36X24x10 Repeatability +0.03 hPa in) Signal Output 0to25Vdc Weight 1359 (4802) Warm-up Time <1s For comprehensive details, visit: www.campbellsci.eu/cs100 CAMPBELL 80 Hathern Road, Shepshed, LE12 9GX UK | +(0)1509 828888 | sale@campbellsci.couk | www.campbellsci.eu SCIENTIFIC AUSTRALIA | BRAZIL | CANADA | CHINA | COSTA RICA | FRANCE | GERMANY | INDIA | SOUTH AFRICA | SPAIN | THAILAND | UK | USA ©2020 Campbell Scientific, Ltd. | 07/01/2020