3kVDC Isolated 1W Single & Dual Output DC-DC Converters KDC_CRV1.D01 Page 1 of 8 www.murata.com www.murata.com For full details go to https://www.murata.com/en- global/products/power/rohs SELECTION GUIDE Order Code Nominal Input Voltage Output Voltage Output Current Input Current at Rated Load Load Regulation (Typ) Load Regulation (Max) Ripple & Noise (Typ)1 Ripple & Noise (Max)1 Efficiency (Min) Efficiency (Typ) Isolation Capacitance MTTF2 V V mA % mVp-p % pF MIL. Tel. kHrs CRV1S0505SC 5 5 200 294 11 14 16 23 67 70 23 4241 CRV1D0512SC 5 ±12 ±42 256 5 7 6.7 8 76 79 26 1579 CRV1D1212SC 12 ±12 ±42 111 4 5 6 10 77 81 42 1287 CRV1S1215SC 12 15 67 108 4 5 8.5 17 79 83 42 1462 INPUT CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Voltage range Continuous operation, 5V input types 4.5 5 5.5 VContinuous operation, 12V input types 10.8 12 13.2 Reflected ripple current All input types 20 40 mA p-p OUTPUT CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Rated Power TA=-40°C to 85°C, See derating curve 1W Voltage Set Point Accuracy See tolerance envelope Line regulation High V IN to low VIN 1.1 1.2 %/% ISOLATION CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Isolation test voltage Flash tested for 1 minute 3000 VDC Resistance Viso= 1000VDC 10 GΩ GENERAL CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Switching frequency 5V input types 120 kHz12V input types 150 ABSOLUTE MAXIMUM RATINGS Lead temperature 1.5mm from case for 10 seconds 260°C Wave Solder Wave Solder profile not to exceed the profile recom- mended in IEC 61760-1 Section 6.1.3. Please refer to application notes for further information. Input volta ge VIN, 5V input 7V Input voltage VIN, 12V input 15V TEMPERATURE CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Specification All output types, (see safety approval sec- tion for limitations) -40 85 °CStorage -50 125 Case Temperature above ambient 5V output types 28 All other output types 25 Cooling Free air convection 1. See Ripple & Noise characterisa tion method. 2. Calculated using MIL-HDBK-217 FN2 and Telcordia SR-332 calculation model with nominal input voltage at full load. All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified. PRODUCT OVERVIEW The CRV1 series of industrial temperature range DC-DC converters are the standard buliding blocks for on-board distributed po wer systems. They are ideally suited for providing local supplies on control system boards with the added benefit of 3kVDC galvanic isolation to reduce switching noise. Available in SIP package with dual and single output pinout. All of the rated power may be drawn from a single output rail provided the total loaddoes not exceed 1 watt.tjjjjjjjjjjjjjjjjjjjjjjjjjjjjjjjjjjjjjj- jjjjjjjjjjjjjjjjjjjjjjjjjjjjjjjjjjjjjjjjjjjjjjjjjjjj

FEATURES

„UL 60950 recognised „Wide temperature performance at full

1 Watt load, –40°C to 85°C

„UL 94V-0 package material „Industry standard pinout „3kVDC isolation (1 minute) ‘Hi Pot Test’ „5V & 12V inputs „5V, 12V & 15V outputs „Fully encapsulated with toroidal magnetics „No external components required „No electrolytic or tantalum capacitors

3kVDC Isolated 1W Single & Dual Output DC-DC Converters KDC_CRV1.D01 Page 2 of 8 www.murata.com TECHNICAL NOTES ISOLATION VOLTAGE ‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test voltage, applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation. Murata Power Solutions CRV1 series of DC-DC converters are all 100% production tested at their stated isolation voltage. This is 3kVDC for 1 minute. A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal operation?” The CRV1 has been recognised by Underwriters Laboratory for functional insulation, both input and output should normally be maintained within SELV limits i.e. less than 42.4V peak, or 60VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system. The part could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier; but then the circuitry on both sides of the barrier must be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-accessible circuitry according to safety standard requirements. REPEATED HIGH-VOLTAGE ISOLATION TESTING It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials, construction and environment. The CRV1 series has toroidal isolation transformers, with no additional insulation between primary and secondary windings of enamelled wire. While parts can be expected to withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any material, including this enamel (typically polyurethane) is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited. We therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from specified test voltage. This consideration equally applies to agency recognised parts rated for better than functional isolation where the wire enamel insulation is always supplemented by a further insulation system of physical spacing or barriers. SAFETY APPROVAL The CRV1 series has been recognised by Underwriters Laboratory (UL) to UL 60950 for functional insulation. The CRV1 Series of converters are not internally fused so to meet the requirements of UL 60950 an anti-surge input line fuse should always be used with ratings as defined below. CRV1S05xxxxC: 0.5A CRV1S12xxxxC: 0.2A All fuses should be UL recognised and rated to at least the maximum allowable DC input voltage. File number E151252 applies. RoHS COMPLIANT INFORMATION This series is compatible with RoHS soldering systems with a peak wave solder temperature of 260°C for 10 seconds. Please refer to application notes for further information. The pin termination finish on the SIP package type is Tin Plate, Hot Dipped over Matte Tin with Nickel Preplate. Both types in this series is backward compatible with Sn/Pb soldering systems. For further information, please visit www.murata-ps.com/rohs PART NUMBER STRUCTURE CRV 1 S XX XX S C Series name Power rating Output type S - Single D - Dual RoHS compliant Package type S - SIP D - DIP M - Surface mount Z - ZIP Output voltageInput voltage

3kVDC Isolated 1W Single & Dual Output DC-DC Converters KDC_CRV1.D01 Page 3 of 8 www.murata.com APPLICATION NOTES Minimum load The minimum load to meet datasheet specification is 10% of the full rated load across the specified input voltage range. Lower than 10% minimum loading will result in an increase in output voltage, which may rise to typically double the specified output voltage if the output load falls to less than 5%. Capacitive loading and start up Typical start up times for this series, with a typical input voltage rise time of 2.2μs and output capacitance of 10μF, are shown in the table below. The product series will start into a capacitance of 47μF with an increased start time, however, the maximum recommended output capacitance is 10μF. Typical Start-Up Wave Form Start-up time μs CRV1S0505SC 1966 CRV1D0512SC 11180 CRV1D1212SC 8650 CRV1S1215SC 11171 CHARACTERISATION TEST METHODS Ripple & Noise Characterisation Method Ripple and noise measurements are performed with the following test configuration. C1 1μF X7R multilayer ceramic capacitor, voltage rating to be a minimum of 3 times the output voltage of the DC-DC converter C2 10μF tantalum capacitor, voltage rating to be a minimum of 1.5 times the output voltage of the DC-DC converter with an ESR of less than 100mΩ at 100 kHz C3 100nF multilayer ceramic capacitor, general purpose R1 450Ω resistor, carbon film, ±1% tolerance R2 50Ω BNC termination T1 3T of the coax cable through a ferrite toroid RLOAD Resistive load to the maximum power rating of the DC-DC converter. Connections should be made via twisted wires Measured values are multiplied by 10 to obtain the specified values. Differential Mode Noise Test Schematic OSCILLOSCOPE Y INPUT SUPPLY C1 C2 C3 R1 T1 R2 Input Output DC/DC Converter R LOAD + + - -

3kVDC Isolated 1W Single & Dual Output DC-DC Converters KDC_CRV1.D01 Page 4 of 8 www.murata.com APPLICATION NOTES (Continued) Output Ripple Reduction By using the values of inductance and capacitance stated, the output ripple at the rated load is lowered to 5mV p-p max. Component selection Capacitor: It is required that the ESR (Equivalent Series Resistance) should be as low as possible, ceramic types are recommended. The voltage rating should be at least twice (except for 15V output), the rated output voltage of the DC-DC converter. Inductor: The rated current of the inductor should not be less than that of the output of the DC-DC converter. At the rated current, the DC resistance of the inductor should be such that the voltage drop across the inductor is <2% of the rated voltage of the DC-DC converter. The SRF (Self Resonant Frequency) should be >20MHz. DC DC L C LoadPower Source Inductor Capacitor L, μH SMD Through Hole C, μF CRV1S0505SC 22 82223C 11R223C 1 CRV1D0512SC 150 82154C 11R154C 0.33 CRV1D1212SC 150 82154C 11R154C 0.33 CRV1S1215SC 220 82224C 11R224C 0.22 TEMPERATURE DERATING GRAPH 150100500-40 0.5 1.0 1.5 Safe Operating Area 85°C Ambient Temperature (°C) Output Power (W) 120°C

3kVDC Isolated 1W Single & Dual Output DC-DC Converters KDC_CRV1.D01 Page 5 of 8 www.murata.com EFFICIENCY VS LOAD 5V Inputs 12V Inputs 0 1 02 03 04 05 06 07 08 09 0 1 0 0 Efficiency (%) Load (%) CRV1D1212SC CRV1S1215SC 0 1 02 03 04 05 06 07 08 09 0 1 0 0 Efficiency (%) Load (%) CRV1D0512SC CRV1S0505SC TOLERANCE ENVELOPES The voltage tolerance envelope shows typical load regulation characteristics for this product series. The tolerance envelope is the maximum output voltage variation due to changes in output loading. CRV1S0505SC CRV1S1215SC CRV1D0512SC CRV1D1212SC 10% Output Load Current (%) Output Load Current (%) Output Load Current (%) Output Load Current (%) Output Voltage Output Voltage Output Voltage Output Voltage -5% -2% -3% -3% -1% -1% 100 100 100 100

3kVDC Isolated 1W Single & Dual Output DC-DC Converters KDC_CRV1.D01 Page 6 of 8 www.murata.com EMC FILTERING AND SPECTRA FILTERING The following table shows the additional input capacitor and input inductor typically required to meet EN 55022 Curve B Quasi-Peak EMC limit, as shown in the following plots. The following plots show positive and negative quasi peak and CISPR22 Average Limit B (pink line) and Quasi Peak Limit B (green line) adherence limits. The recom- mended input capacitor to use for this circuit is 50V 16V X7R ceramic capacitor. Inductor Capacitor Part Number L, μH SMD Through Hole C, μF CRV1D0512SC 10uH 13R103C 1uF CRV1S0505SC 10uH 13R103C 1uF CRV1D1212SC 10uH 13R103C 1uF CRV1S1215SC 4.7uH 13R472C 1uF CRV1D0512SC CRV1D1212SC CRV1S0505SC CRV1S1215SC 1.00E+05 1.00E+06 1.00E+07 1.00E+08 dBuV Frequency (Hz) 1.00E+05 1.00E+06 1.00E+07 1.00E+08 dBuV Frequency (Hz) 1.00E+05 1.00E+06 1.00E+07 1.00E+08 dBuV Frequency (Hz) 1.00E+05 1.00E+06 1.00E+07 1.00E+08 dBuV Frequency (Hz) DC DC C L

3kVDC Isolated 1W Single & Dual Output DC-DC Converters KDC_CRV1.D01 Page 7 of 8 www.murata.com PACKAGE SPECIFICATIONS MECHANICAL DIMENSIONS RECOMMENDED FOOTPRINT DETAILS TUBE OUTLINE DIMENSIONS PIN CONNECTIONS Single output variants Dual output variants Pin Function Pin Function 1V IN 1V IN

2 GND 2 GND

7 +Vout 6* OV 7 +Vout 5.0 [0.197] 12.43 [0.489] 18.0 [0.709] 9.3 [0.366] Unless otherwise specified all dimensions in mm [inches] ±0.55mm. Tube length : 20.47 (520mm ±2mm). Tube Quantity : 35 (1.13 [0.044]) (1.93 [0.076]) 5.08 [0.200] 15.24 [0.600] 12 5 7 2.54 [0.100] S 2.54 [0.100] 0.4 [0.016] MIN CRV1DxxxxSC XYYWW x5 HOLES Ø1.15 1.00 [Ø 0.045 0.039 ] 2.54 [0.100] 2.54 [0.100] * Pin not fitted on single output variants. All dimensions in mm (inches) Controlling dimension is mm. For SIP products, from date code D2224 onwards, products have an embossed logo on the top of the case. Prior to this date, SIP products have a flat surface finish. Weight: 2.1g *Hole not required for single output variants.

3kVDC Isolated 1W Single & Dual Output DC-DC Converters KDC_CRV1.D01 Page 8 of 8 www.murata.com Murata Power Solutions (Milton Keynes) Ltd. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. © 2022 Murata Power Solutions (Milton Keynes) Ltd. This product is subject to the following operating requirements and the Life and Safety Critical Application Sales Policy: Refer to: https://www.murata.com/en-eu/products/power/requirements DISCLAIMER Unless otherwise stated in the datasheet, all products are designed for standard commercial and industrial applications and NOT for safety-critical and/or life-critical applications. Particularly for safety-critical and/or life-critical applications, i.e. applications that may directly endanger or cause the loss of life, inflict bodily harm and/or loss or severe damage to equipment/property, and severely harm the environment, a prior explicit written approval from Murata is strictly required. Any use of Murata standard prod- ucts for any safety-critical, life-critical or any related applications without any prior explicit written approval from Murata shall be deemed unauthorised use. These applications include but are not limited to:

  • Aircraft equipment
  • Aerospace equipment
  • Undersea equipment
  • Power plant control equipment
  • Medical equipment
  • Transportation equipment ( automobiles, trains, ships, etc.)
  • Traffic signal equipment
  • Disaster prevention / crime prevention equipment
  • Data Processing equipment Murata makes no express or implied warranty, representation, or guarantee of suitability, fitness for any particular use/purpose and/or compatibility with any applica- tion or device of the buyer, nor does Murata assume any liability whatsoever arising out of unauthorised use of any Murata product for the application of the buyer. The suitability, fitness for any particular use/purpose and/or compatibility of Murata product with any application or device of the buyer remain to be the responsibility and liability of the buyer. Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards that anticipate dangerous consequences of failures, moni- tor failures and their consequences, lessen the likelihood of failures that might cause harm, and take appropriate remedial actions. Buyer will fully indemnify and hold Murata, its affiliated companies, and its representatives harmless against any damages arising out of unauthorised use of any Murata products in any safety-critical and/ or life-critical applications. Remark: Murata in this section refers to Murata Manufacturing Company and its affiliated companies worldwide including, but not limited to, Murata Power Solutions.