CRE-10201 OKAYA | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 1

Technical content

Features

Applications

  • Broad use in industrial applications.
  • External mounting tab.
  • 1/2 watt non-inductive, high pulse resistor.
  • Three phase delta connection (3 CRE). Three phase three line (6 CRE).
  • Automatic machines and industrial machinery. Operating Temperature: -40~+85°C UL VDE :UL1283 :IEC/EN 60384-14: 2005 E78644 128527 Safety Standard File No. Rated Voltage 250VAC 4.5 300min. 5.5 W±1 H±1 T±1 10±2 3±0.5 (AWG18) UL-1015 φ 4.3 5.510±2 300min. T±1 11 F±3 F±3 φ 4.3 W±1 3±0.5 (AWG18) UL-1015 4.5 H±1 300min. H±1 T±1 F±1 φ 4.3 W±1 (AWG18) UL-1015 Unit: mm CRE Series 6CRE3CRECRE CRE 3CRE 6CRE 3CRE (3 Phase) 6CRE (3 Phase) Soldering Soldering Soldering * 3CRE-30680 is not UL approved.
  • Model numbering system Series name Supported number Resistance 201 151 680 500 200Ω 150Ω 68Ω 50Ω Capacitance 0.1μF 0.2μF 0.3μF 0.5μF None

1 Phase

3 Phase

3 Line

0.1 0.2 0.3 0.5 0.3/1 phase 0.5 /1 phase 200(1/2W) 150(1/2W) 68(1/2W) 50(1/2W) 68 (1/2W) /1 phase 50(1/2W) /1 phase Capacitance μF±20% Resistance Ω±30% Dimensions W H T F 48 - 35 26 Peak to peak Pulse width Repetitive frequency Pulse width (sec) x Frequency(Hz) Peak Pulse Voltage Pulse condition (max.) 700V 50msec. 70msec. 360Hz. 0.45 0.15 0.1 0.07 0.1 Test Voltage Insulation Resistance Line to Line 10,000MΩ min. Line to Case 100,000MΩmin. (at 500VDC) Line to Line 625VAC 50/60Hz 60sec Line to Case 2,000VAC 50/60Hz 60sec 800V max. 0.07 The combination of Resistance and Capacitance is shown in following chart. CRE, 3CRE, 6CRE SERIES SPARK QUENCHER