=] SCIENTIFIC WHEN MEASUREMENTS MATTER Overview The CR350 is a multi-purpose, extremely low power, compact measurement and control data logger. This entry- level data logger, with its rich instruction set, can measure most hydrological, meteorological, environmental, and industrial sensors. The CR350 concentrates data, makes it available over varied networks, and delivers it using your preferred protocol. The CR350 also performs automated on- site or remote decision-making for control and M2M communications. This data logger is ideal for small applications requiring long-term, remote monitoring and control. The following outlines the primary differences between the CR300, CR310, and CR350 dataloggers: ) The CR310 and CR350 offer removable connectors. ) The CR310 includes a 10/100 Ethernet connection. Benefits and Features ) Two dedicated SDI-12 terminals to expand SDI-12 sensor use ) Extremely low current requirements ) Two dedicated RS-232/RS-485 terminals to support smart sensors or modems ) Easy setup with PC software and USB-C connectivity ) Ability to measure analog and digital sensors with confidence ) Trusted Campbell Scientific quality, including integral surge and ESD protection W R(RES CR350 Measurement and Control Datalogger Compact Data Logger with RS-485 Ideal for small applications ) The CR350 has two independent RS-232/RS-485 ports and USB-C. The CR350 includes Wi-Fi, cellular, or the following radio options for different regions: ) CR350-RF407: US and Canada ) CR350-RF412: Australia and New Zealand ) CR350-RF422: Europe ) CR350-RF427: Brazil Note: Campbell Scientific does not recommend the CR350 for use as a PakBus router in networks with more than 50 devices. Large arrays or string variables may also reach memory limits. For such applications, a CR1000X Measurement and Control Datalogger is recommended. ) Integrated radio option to network wirelessly to another node or Internet gateway ) CR350-WIF! ideal for short-range, wireless IP communication ) Removable terminal block for easy wiring ) Ability to communicate anywhere using built-in cellular or satellite peripherals ) Integrated 12 V battery solar charge regulator to charge batteries ) Flexibility to connect with PakBus, Modbus, DNP3, GOES, and other standard communication protocols For comprehensive details, visit: www.campbellsci.eu/cr350

) Multiple general-purpose /O and programmability to analyze and control measurement acquisition Technical Description The CR350 is a low-powered data logger designed to measure sensors, analyze data, and store data and programs. A battery-backed clock assures accurate timekeeping. The on-board, BASIC-like programming language—common to all Campbell Scientific data loggers—supports data processing and analysis routines. Terminal Descriptions ) Two switched 12 V terminals (SW12V) for powering sensors or communication devices, 2100 mA ) Two sensor excitation or continuous 0.15 to 5V terminals (VX1, VX2) for sensor excitation or output control ) Four multipurpose analog input terminals (SE1-SE4) ) Analog functions (SE1-SE4) ) Analog inputs: 4 single-ended or 2 differential inputs with -100 to +2500 mV and +34 mV ranges 24 bit ADC ) 41t020 mA or0to 20 mA inputs (SE1, SE2 only) ) Digital /O functions (SE1-SE4) consist of 3.3 V logic levels for: ) High frequency counter (35 kHz) ) Pulse width modulation ) Interrupts and timer input ) Period average (200 kHz, amplitude dependent) Specifications Operating Temperature -40°to +70°C Range Non-condensing environment Maximum Scan Rate 10Hz Case Material High-impact-resistant polycarbonate, recycle code 7 Analog Inputs 4single-ended or 2 differential (individually configured) Pulse Counters 8(P_SW, P_LL,C1,C2,and SE1 to SE4) Voltage Excitation Terminals2 (VX1, VX2) Communications Ports RS-232 RS-485 USB Type C 20 Switched 12 Volt 2 terminals Digital I/0 7 terminals (C1, C2, P_SW, and SE1 to SE4) configurable for digital input and output. Includes status high/low, pulse width modulation, external interrupt, and communication functions. Exception: C2 and ) Event-driven communications and physical outputs for notifications ) Two Pulse Counting Terminals (P_SW, P_LL) )P SW ) Switch closure (150 Hz) ) High frequency counter (35 kHz) yP_LL ) Low level ac (20 kHz) ) High frequency counter (20 kHz) ) Two Control Terminals (C1, C2): C terminals are software configurable for digital functions ) Digital /O functions consist of 5V output and 3.3 Vinput logic levels for: )SDL12 ) High frequency counter (3 kHz) ) Switch closure (150 Hz) ) General status/control voltage source 5 V; 10 mA @ 3.5 ) Interrupts ) Serial asynchronous communication Tx/Rx pair P_SW don't do pulse-width modulation. Analog Input Limits -100 to +2500 mV/ Analog Voltage Accuracy +(0.04% of measurement + offset) at 0° to 40°C Accuracy specifications do not include sensor or measurement noise. +(0.1% of measurement + offset) at -40°to +70°C ADC 24-bit Power Requirements 16 to 32 Vdc for charger input (CHG) (Current limited to 1.1 A maximum for power converter orsolar panel input) Real-Time Clock Accuracy 3 min. per year Ethernet, PPP, RNDIS, ICMP/Ping, Auto-IP(APIPA), IPv4, IPv6, UDP, TCP, TLS (v1.2), DNS, DHCP, SLAAC, NTP, Telnet, HTTP(S), FTP(S), SMTP/TLS, POP3/TLS, MQTT(S) Internet Protocols For comprehensive details, visit: www.campbellsci.eu/cr350

Communication Protocols PakBus, PakBus Encryption, Modbus RTU/ASCII/TCP, DNP3, SDI112, and others

50 MB serial flash

Data Storage 50 MB serial flash Idle Current Drain, Average 0.5 mA (@ 12 Vdc) Active Current Drain, 8 mA (@ 12 Vdc with processor Average always on) <1.5mA (@ 12 Vdc for 1 Hz scan with 1 analog measurement) 163x84x56Ccm (64x33x2.2 in) Additional clearance required for cables and leads. Weight 28810 306 g (0.64 10 0.68 Ib) depending on communication option selected CR350-RF407 Option Radio Type CPU Drive/Programs Dimensions Frequency Hopping Spread Spectrum (FHSS) 510250 mW (user-selectable) Frequency 902 to 928 MHz (US, Canada) RF Data Rate 200 kbps -101 dBm RPSMA (External antenna required; see www.campbellsci.com/order/ 1f407 for Campbell Scientific antennas) Idle Current Drain, Average 12 mA (@ 12Vdd) <80mA (@12Vda) Output Power Receive Sensitivity Antenna Connector Active Current Drain, Average CR350-RF412 Option Radio Type Frequency Hopping Spread Spectrum (FHSS) Output Power 510250 mW (user-selectable) Frequency 915 to 928 MHz (Australia, New Zealand) RF Data Rate 200 kbps Receive Sensitivity -101 dBm Antenna Connector RPSMA (External antenna required; see www.campbellsci.com/order/ 1f412 for Campbell Scientific antennas) Idle Current Drain, Average 12 mA (@ 12Vdd) Active Current Drain, <80mA (@12Vda) Average CR350-RF422 Option Radio Type 868 MHz SRD 860 with Listen Before Talk (LBT) and Automatic Frequency Agility (AFA) Output Power 2t0 25 mW (user-selectable) Frequency 863 to 870 MHz (European Union) RF Data Rate 10kbps Receive Sensitivity -106 dBm Antenna Connector RPSMA (External antenna required; see www.campbellsci.com/order/ 1f422 for Campbell Scientific antennas) Idle Current Drain, Average 9.5 mA Active Current Drain, 20mA Average CR350-RF427 Option Radio Type Frequency Hopping Spread Spectrum (FHSS) Output Power 510250 mW (user-selectable) Frequency 902 to 907.5 MHz/915 to 928 MHz (Brazil) RF Data Rate 200 kbps Receive Sensitivity -101 dBm Antenna Connector RPSMA (External antenna required) Idle Current Drain, Average 12 mA (@ 12Vdc) Active Current Drain, <80mA (@12 Vdo) Average CR350-RF452 Option Radio Type Frequency Hopping Spread Spectrum (FHSS) Output Power 10mWto 1,000 mW (user- selectable) Frequency 902 to 928 MHz RF Data Rate Receive Sensitivity 115.20r 1536 kbps -103 dBm (@ 1536 kbps for

10 BER

-108 dBm (@ 115.2 kbps for

107 BER

Antenna Connector RPSMA (External antenna required) Idle Current Drain, Average <29 mA (maximum @ 12 Vdc) Active Current Drain, < 84mA (maximum @ 12 Vdc) Average CR350-WIFI Option Operational Modes Client or Access Point For comprehensive details, visit: www.campbellsci.eu/cr350

24 GHz, 20 MHz bandwidth

Reverse Polarity SMA (RPSMA) pn 16005 unity gain (0 dBd), 1/2 wave whip, omnidirectional with articulating knuckle joint for vertical or horizontal orientation 710 18dBm (5 to 63 mW) CR350-CELL205 Option -NOTE- The CR350-CELL 205 option is not compatible with a Verizon cellular network. Certifications IC (Industry Canada) Cell Technologies 3G Frequency Bands 4G Frequency Bands Antenna Connector Power Consumption - Idle Power Consumption - Active SIM Interface Radio Output Power Radio Sensitivity Range 10224A-201611EC21A 4G (LTECAT-1) 3G (UMTS/HSPA+) 850, 1700/2100 (AWS), and 1900 1900 SMA (External antenna required; see www.campbellsci.com/ order/cr350 for Campbell Scientific antennas.) 14 mA (average) 75 mA (average) 3FF (6 position/contacts) Supports SIMs that require 1.8 or 24 dBm on UMTS 23 dBmonLTE 33 dBm on GSM 27 dBm on EDGE -99.5t0 110.5dBm (10 M) CR350-CELL210 Option -NOTE- Cell Technologies 4G Frequency Bands Antenna Connector Power Consumption - Low Power Mode Power Consumption - Idle Power Consumption - Active SIM Interface The CR350-CELL210 option is only compatible with a Verizon cellular network. 4G (LTE CAT-1) 700, 850, 1700, 1900, 2100 SMA (External antenna required; see www.campbellsci.com/ order/cr350 for Campbell Scientific antennas.) 5mA 28 mA (average) 90 mA (average) 3FF (6 position/contacts) Supports SIMs that require 1.8 or Radio Output Power 23dBmon LTE Radio Sensitivity Range -99.5t0 110.5dBm (10 M) CR350-CELL215 Option -NOTE- The CR350-CELL215 option is Intended for use in EMEA countries. Cell Technologies 3G (UMTS/HSPA+) 4G (LTE CAT-1) 2G (GSM/GPRS/EDGE) 2G Frequency Bands 900 and 1800 MHz 3G Frequency Bands 850, 900, and 2100 MHz 4G Frequency Bands 800, 850, 900, 1800, 2100, and

2600 MHz

Antenna Connector SMA (External antenna required; see www.campbellsci.com/ order/cr350 for Campbell Scientific antennas.) Power Consumption -Idle 14 mA (average) Power Consumption - 75 mA (average) Active SIM Interface 3FF (6 position/contacts) Supports SIMs that require 1.8 or Radio Output Power 33 dBm on GSM 27 dBm on EDGE 23 dBmonLTE 24 dBm on UMTS Radio Sensitivity Range -99.5t0 110.5dBm (10 M) CR350-CELL220 Option -NOTE- The CR350-CELL220 option is Intended for use in Australia and New Zealand. Cell Technologies 3G (UMTS/HSPA+) 4G (LTE CAT-1) 3G Frequency Bands 850,900, 1900, and 2100 MHz (EC-21AU) 850and 2100 MHz (EC-21AUT) 4G Frequency Bands 700, 850, 1800, 2100, and 2600 MHz (EC-21AUT) 700, 900, 1700, 1800, 1900, 2100, and 2600 MHz (EC-21AU) Antenna Connector SMA (External antenna required; see www.campbellsci.com/ order/cr350 for Campbell Scientific antennas.) Power Consumption -Idle 14 mA (average) Power Consumption - 75 mA (average) Active SIM Interface 3FF (6 position/contacts) Supports SIMs that require 1.8 or For comprehensive details, visit: www.campbellsci.eu/cr350

Radio Output Power 23dBmonlLTE 24 dBm on UMTS Radio Sensitivity Range -99.5to 110.5dBm (10 M) CR350-CELL225 Option -NOTE- The CR350-CELL225 option is Intended for use in Japan. 4G (LTE CAT-1) 800 (lower), 800 (upper), 850+, 900, 1800, and 2100 MHz SMA (External antenna required; see www.campbellsci.com/ order/cr350 for Campbell Scientific antennas.) Cell Technologies 4G Frequency Bands Antenna Connector Power Consumption -Idle 14 mA (average) Power Consumption - 75 mA (average) Active SIM Interface 3FF (6 position/contacts) Supports SIMs that require 1.8 or Radio Output Power 23dBmon LTE Radio Sensitivity Range -99.5t0 110.5dBm (10 M) CR350-CELL230 Option Cell Technologies Frequency Bands Antenna Connector Power Consumption - Idle Power Consumption - Active SIM Interface LTE-Cat M, NB-loT LTE NB-loT B1/B2/B3/B4/B5/ B8/ B12/B13/B18/B19/ B20/ B25/B28/B66/B71/B85 LTE M B1/B2/B3/B4/B5/B8/ B12/B13/B18/B19/B20/B25/ B26/B27/B28/B66/B85 SMA (External antenna required; see www.campbellsci.com/ order/cr350 for Campbell Scientific antennas.) 23 mAaverage (26 mA if GPS is on) 50 mAaverage (53 mA if GPS is on) 3FF (6 position/contacts) Supports SIMs that require 1.8 or ol For comprehensive details, visit: www.campbellsci.eu/cr350 CAMPBELL 80 Hathern Road, Shepshed, LE12 9GX UK | +(0)1509 828888 | sales@campbellsci.couk | www.campbellsci.eu SCIENTIFIC AUSTRALIA | BRAZIL | CANADA | CHINA | COSTA RICA | FRANCE | GERMANY | INDIA | SOUTH AFRICA | SPAIN | THAILAND | UK | USA ©2024 Campbell Scientific, Ltd. | 02/29/2024