=) SCIENTIFIC ~ WHEN MEASUREMENTS MATTER Overview The CR310 is a multi-purpose, compact, low-cost measurement and control data logger that includes an integrated 10/100 Ethernet port and removable terminal connectors. This entry-level data logger, with its rich instruction set, can measure most hydrological, meteorological, environmental, and industrial sensors. It will concentrate data, making it available over varied networks and deliver it using your preferred protocol. The CR310 also performs automated on-site or remote decision making for control and M2M communications. The CR310 is ideal for small applications requiring long-term, remote monitoring and control. The primary differences between the CR300 and CR310 are that the CR310 offers removable connectors and a 10/100 Ethernet connection. Benefits and Features ) Set up easily with PC software and USB connectivity ) Measure with confidence analogue and digital sensors ) Internet ready—email, FTP, HTTP/web, TCP-with required add-ons ) Trust in the Campbell Scientific quality, including integral surge and ESD protection ) Save money and space using the integrated Ethernet port ) Network wirelessly to another node or Internet gateway with integrated radio option ) CR310-WIF! ideal for short-range, wireless IP communication NEUENS CR310 Datalogger with Ethernet Compact Data Logger with Ethernet Ideal for small applications The CR310 has multiple radio options that are suitable for different regions: ) CR310-RF407: US and Canada ) CR310-RF412: Australia and New Zealand ) CR310-RF422: Europe ) CR310-RF427: Brazil Note: Campbell Scientific does not recommend the CR310 for use as a PakBus router in networks with more than 50 devices. Large arrays or string variables may also reach memory limits. For such applications, a CR1000X Measurement and Control Datalogger is recommended. ) Wiring made easy through removable terminal block ) Communicate from anywhere when using cellular or satellite peripheral ) Charge batteries using the integrated 12 V battery solar charge regulator ) Measure smart sensors using RS-232 or SDI-12 ) Connect with PakBus, Modbus, DNP3, GOES, and other standard communication protocols ) Analyze and control with programmability and multiple general purpose /0O ) Notify with event-driven communications and physical outputs For comprehensive details, visit: www.campbellsci.eu/cr310

) One switched 12V terminal (SW12V) for powering sensors or communication devices, 1100 mA @ 20°C ) Two sensor excitation or continuous 0.15 to 5V terminals (VX1, VX2) for sensor excitation or output control ) Six multipurpose analogue input terminals (SE1 - SE6) ) Analogue functions (SE1 - SE6) ) Analogue inputs: 6 single-ended or 3 differential inputs with -100 to +2500 mV and +34 mV ranges 24 bit ADC ) 41020 mA or 0 to 20 mA inputs (SE1, SE2 only) ) Digital /O functions (SET - SE4) consist of 3.3 V logic levels for: ) High frequency counter (35 kHz) ) Pulse width modulation ) Interrupts and timer input ) Period average (200 kHz, amplitude dependent) Specifications -NOTE- Additional specifications are listed in the CR300-Series Specifications Sheet. Operating Temperature Range Non-condensing environment -40°to +70°C (standard) Maximum Scan Rate 10Hz Case Material Powder-coated aluminum Analog Inputs 6 single-ended or 3 differential (individually configured) Pulse Counters 8(P_SW, P_LL,C1,C2,and SE1 to SE4) Voltage Excitation Terminals2 (VX1, VX2) Communications Ports RS-232 10/100 Ethernet RJ45 USB Micro B Switched 12 Volt 1 terminal Digital I/0 7 terminals (C1, C2, P_SW, and SE1 to SE4) configurable for digital input and output. Includes status high/low, pulse width modulation, external interrupt, and communication functions. Exception: The SE4 terminal doesn't do external interrupt. Input Limits -100 to +2500 mV/ ) Two Pulse Counting Terminals (P_SW, P_LL) )P_SW ) Switch closure (150 Hz) ) High frequency counter (35 kHz) yP_LL ) Low level ac (20 kHz) ) High frequency counter (20 kHz) ) Two Control Terminals (C1, C2): C terminals are software configurable for digital functions ) Digital /O functions consist of 5V output and 3.3 Vinput logic levels for: )SD-12 ) High frequency counter (3 kHz) ) Switch closure (150 Hz) ) General status/control ) Voltage source 5V: 10mA@ 3.5V ) Interrupts ) Serial asynchronous communication Tx/Rx pair +(0.04% of measurement + offset) at 0° to 40°C +(0.1% of measurement + offset) at -40°to +70°C Accuracy specifications do not include sensor or measurement noise. ADC 24-bit 16 to 32 Vdc for charger input (CHG) (Current limited to 0.9 A maximum for power converter orsolar panel input) Analog Voltage Accuracy Power Requirements Power Requirements 10to 18 Vdc for external batteries (BAT) +1 min. per month Ethernet, PPP, RNDIS, ICMP/Ping, Auto-IP(APIPA), IPv4, IPv6, UDP, TCP, TLS (v1.2), DNS, DHCP, SLAAC, NTP, Telnet, HTTP(S), FTP(S), SMTP/TLS, POP3/TLS Communications Protocols PakBus, Modbus, DNP3, SDI-12, TCP, UDP, and others

80 MB serial flash

30 MB serial flash

10mA (@ 12 Vdc with Ethernet linkidle) Real-Time Clock Accuracy Internet Protocols CPU Drive/Programs Data Storage Idle Current Drain, Average For comprehensive details, visit: www.campbellsci.eu/cr310

Active Current Drain, 56 mA (@ 12 Vdc with Ethernet Average link active, processor always on) 22in) Weight 28810 306 g (0.64 10 0.68 Ib) depending on communication option selected CR310-RF407 Option Radio Type Frequency Hopping Spread Spectrum (FHSS) Output Power 510250 mW (user-selectable) Frequency 902 to 928 MHz (US, Canada) RF Data Rate 200 kbps Receive Sensitivity -101 dBm Antenna Connector RPSMA (external antenna required; see www.campbellsci.com/order/ 1f407 for Campbell Scientific antennas) Idle Current Drain, Average 12 mA (@ 12Vdd) Active Current Drain, <80mA (@12Vda) Average CR310-RF412 Option Radio Type Frequency Hopping Spread Spectrum (FHSS) Output Power 510250 mW (user-selectable) Frequency 915 to 928 MHz (Australia, New Zealand) RF Data Rate 200 kbps Receive Sensitivity -101 dBm Antenna Connector RPSMA (external antenna required; see www.campbellsci.com/order/ 1f412 for Campbell Scientific antennas) Idle Current Drain, Average 12 mA (@ 12Vdd) Active Current Drain, <80mA (@12Vda) Average CR310-RF422 Option Radio Type 868 MHz SRD 860 with Listen Before Talk (LBT) and Automatic Frequency Agility (AFA) Output Power 21025 mW (user-selectable) Frequency 863 to 870 MHz (European Union) RF Data Rate 10kbps Receive Sensitivity -106 dBm Antenna Connector (External antenna required; see www.campbellsci.com/order/ 1f422 for Campbell Scientific antennas) Idle Current Drain, Average 9.5 mA Active Current Drain, 20mA Average CR310-RF427 Option Radio Type Frequency Hopping Spread Spectrum (FHSS) Output Power 510250 mW (user-selectable) Frequency 902 to 907.5 MHz/915 to 928 MHz (Brazil) RF Data Rate 200 kbps Receive Sensitivity -101 dBm Antenna Connector RPSMA (External antenna required.) Idle Current Drain, Average 12 mA (@ 12Vdc) Active Current Drain, <80mA (@12 Vdo) Average CR310-WIFI Option Operational Modes Client or Access Point

24 GHz, 20 MHz bandwidth

Antenna Connector Reverse Polarity SMA (RPSMA) Antenna pn 16005 unity gain (0 dBd), 1/2 wave whip, omnidirectional with articulating knuckle joint for vertical or horizontal orientation 7t018dBm (5 to 63 mW) Operating Frequency Transmit Power CR310-CELL205 Option -NOTE- The CR310-CELL205 option is not compatible with a Verizon cellular network. Cell Technologies 4G (LTE CAT-1) 3G (UMTS/HSPA+) 850, 1700/2100 (AWS), and 1900 700, 850, 1700/2100 (AWS-1), 1900 SMA (External antenna required; see www.campbellsci.com/ order/cr310 for Campbell Scientific antennas.) 3G Frequency Bands 4G Frequency Bands Antenna Connector SIM Interface 3FF (6 position/contacts) Supports SIMs that require 1.8 or 3V. CR310-CELL210 Option -NOTE- The CR310-CELL210 option is only compatible with a Verizon cellular network. CR310-CELL205 Option No Cell Technologies 4G (LTE CAT-1) For comprehensive details, visit: www.campbellscieu/cr310

4G Frequency Bands 700, 850, 1700, 1900, 2100 Antenna Connector SMA (External antenna required; see www.campbellsci.com/ order/cr310 for Campbell Scientific antennas.) SIM Interface 3FF (6 position/contacts) Supports SIMs that require 1.8 or 3V. CR310-CELL215 Option -NOTE- The CR310-CELL215 option is Intended for use in EMEA countries. Cell Technologies 3G (UMTS/HSPA+) 2G (GSM/GPRS/EDGE) 4G (LTECAT-1) 2G Frequency Bands 900 and 1800 MHz 3G Frequency Bands 850, 900, and 2100 MHz 4G Frequency Bands 800, 850, 900, 1800, 2100, and

2600 MHz

Antenna Connector SMA (External antenna required; see www.campbellsci.com/ order/cr310 for Campbell Scientific antennas.) SIM Interface 3FF (6 position/contacts) Supports SIMs that require 1.8 or 3V. CR310-CELL220 Option -NOTE- The CR310-CELL220 option is Intended for use in Australia and New Zealand. Cell Technologies 3G Frequency Bands 4G Frequency Bands Antenna Connector 4G (LTE CAT-1) 3G (UMTS/HSPA+) 850,900, 1900, and 2100 MHz (EC-21AU) 850and 2100 MHz (EC-21AUT) 700, 850, 1800, 2100, and 2600 MHz (EC-21AUT) 700, 900, 1700, 1800, 1900, 2100, and 2600 MHz (EC-21AU) SMA (External antenna required; see www.campbellsci.com/ order/cr310 for Campbell Scientific antennas.) SIM Interface 3FF (6 position/contacts) Supports SIMs that require 1.8 or 3V. CR310-CELL225 Option -NOTE- The CR310-CELL225 option is Intended for use in Japan. Cell Technologies 4G Frequency Bands Antenna Connector SIM Interface 4G (LTE CAT-1) 800 (lower), 800 (upper), 850+, 900, 1800, and 2100 MHz SMA (External antenna required; see www.campbellsci.com/ order/cr310 for Campbell Scientific antennas.) 3FF (6 position/contacts) Supports SIMs that require 1.8 or 3V. B For comprehensive details, visit: www.campbellscieu/cr310 CAMPBELL 80 Hathern Road, Shepshed, LE12 9GX UK | +(0)1509 828888 | sales@campbellsci.couk | www.campbellsci.eu SCIENTIFIC AUSTRALIA | BRAZIL | CANADA | CHINA | COSTA RICA | FRANCE | GERMANY | INDIA | SOUTH AFRICA | SPAIN | THAILAND | UK | USA ©2024 Campbell Scientific, Ltd. | 09/23/2024