CR300 CAMPBELL | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 4
Technical content
=] SCIENTIFIC WHEN MEASUREMENTS MATTER Overview The CR300 is a multi-purpose, compact measurement and control data logger. This small, low-cost, high-value data logger offers fast communications, low power requirements, built-in USB, and excellent analog input accuracy and resolution. The CR300 can measure most hydrological, meteorological, environmental, and industrial sensors. It concentrates data, makes it available over varied networks, and delivers it using your preferred protocol. It also performs automated on-site or remote decision making for control and M2M communications. The CR300 is ideal for small applications requiring long-term, remote monitoring and control. Benefits and Features ) Connects directly to a computer's USB port ) Differentiates even slight changes in data values with higher resolutions measurements (24 bit Adc) ) Provides simple serial sensor integration and measurement with SDI-12 and/or RS-232 Technical Description The CR300 is a low-powered data logger designed to measure sensors, analyze data, and store data and programs. A battery-backed clock assures accurate timekeeping. The on-board, BASIC-like programming language—common to CR30 Datalogger Compact Data Logger Ideal for small applications The CR300 includes Wi-Fi, cellular, or the following radio options for different regions: ) CR300-RF407: US and Canada ) CR300-RF412: Australia and New Zealand ) CR300-RF422: Europe ) CR300-RF427: Brazil Note: Campbell Scientific does not recommend the CR300 for use as a PakBus router in networks with more than 50 devices. Large arrays or string variables may also reach memory limits. For such applications, a CR1000X Measurement and Control Datalogger is recommended. ) Supports full PakBus networking ) Includes embedded web page for direct connection via web browser all Campbell Scientific data loggers—supports data processing and analysis routines. The CR300 wiring panel includes a switchable 12V terminal, and analog grounds dispersed among six analog terminals. For comprehensive details, visit: www.campbellsci.eu/cr300
-NOTE- Operating Temperature Range Maximum Scan Rate Case Material Analog Inputs Pulse Counters Voltage Excitation Terminals2 (VX Communications Ports Switched Digital I/0
12 Volt
Idle Current Drain, Average Additional specifications are listed in the CR300-Series Specifications Sheet. Non-condensing environment -40°to +70°C (standard) 10Hz Powder-coated aluminum 6 single-ended or 3 differential (individually configured) 8(P_SW, P_LL,C1, C2,and SE1 to SE4) 1,VX2) RS-232 USB Micro B 1 terminal 7 terminals (C1, C2, P_SW, and SE1 to SE4) configurable for digital input and output. Includes status high/low, pulse width modulation, external interrupt, and communication functions. Exception: The SE4 terminal doesn't do external interrupt. -100 to +2500 mV Accuracy specifications do not include sensor or measurement noise. +(0.04% of measurement + offset) at 0° to 40°C +(0.1% of measurement + offset) at -40°to +70°C 24-bit 16 to 32 Vdc for charger input (CHG) (Current limited to 0.9 A maximum for power converter orsolar panel input) 10to 18 Vdc for external batteries (BAT) +1 min. per month Ethernet, PPP, RNDIS, ICMP/Ping, Auto-IP(APIPA), IPv4, IPv6, UDP, TCP, TLS (v1.2), DNS, DHCP, SLAAC, NTP, Telnet, HTTP(S), FTP(S), SMTP/TLS, POP3/TLS PakBus, Modbus, DNP3, SDI-12, TCP, UDP, and others
80 MB serial flash
30 MB serial flash
15mA (@ 12 Vdo) Active Current Drain, Average Dimensions Weight CR300-RF407 Option Radio Type Output Power Frequency RF Data Rate Receive Sensitivity Antenna Connector Idle Current Drain, Average Active Current Drain, Average CR300-RF412 Option Radio Type Output Power Frequency RF Data Rate Receive Sensitivity Antenna Connector Idle Current Drain, Average Active Current Drain, Average CR300-RF422 Option Radio Type Output Power Frequency 23 mA (@ 12 Vdc with processor always on) 5mA (@ 12 Vdc for 1 Hz scan with 1 analog measurement) 18in) Additional clearance required for cables and leads. 24210 250 g (0.53 t0 0.55 Ib) depending on communication option selected Frequency Hopping Spread Spectrum (FHSS) 510250 mW (user-selectable) 902 to 928 MHz (US, Canada) 200 kbps -101 dBm RPSMA (External antenna required; see www.campbellsci.com/order/ 1f407 for Campbell Scientific antennas) 12mA(@12Vdao) <80mA (@12 Vdo) Frequency Hopping Spread Spectrum (FHSS) 510250 mW (user-selectable) 915 t0 928 MHz (Australia, New Zealand) 200 kbps -101 dBm RPSMA (External antenna required; see www.campbellsci.com/order/ 1f412 for Campbell Scientific antennas) 12mA(@12Vdao) <80mA (@12 Vdo)
868 MHz SRD 860 with Listen
Before Talk (LBT) and Automatic Frequency Agility (AFA) 2t0 25 mW (user-selectable) 863 to 870 MHz (European Union) For comprehensive details, visit: www.campbellsci.eu/cr300
-106 dBm RPSMA (External antenna required; see www.campbellsci.com/order/ 1f422 for Campbell Scientific antennas) Antenna Connector Idle Current Drain, Average 9.5 mA Active Current Drain, 20mA Average CR300-RF427 Option Radio Type Frequency Hopping Spread Spectrum (FHSS) Output Power 510250 mW (user-selectable) Frequency 902 to 907.5 MHz/915 to 928 MHz (Brazil) RF Data Rate 200 kbps Receive Sensitivity -101 dBm Antenna Connector RPSMA (External antenna required.) 12mA(@12Vdao) <80mA (@12Vda) Idle Current Drain, Average Active Current Drain, Average CR300-WIFI Option Operational Modes Client or Access Point
24 GHz, 20 MHz bandwidth
Reverse Polarity SMA (RPSMA) pn 16005 unity gain (0 dBd), 1/2 wave whip, omnidirectional with articulating knuckle joint for vertical or horizontal orientation 710 18dBm (5 to 63 mW) Operating Frequency Antenna Connector Antenna Transmit Power CR300-CELL205 Option -NOTE- The CR300-CELL205 option is not compatible with a Verizon cellular network. Certifications IC (Industry Canada) 10224A-201611EC21A Cell Technologies 3G (UMTS/HSPA+) 4G (LTECAT-1) 850, 1700/2100 (AWS), and 1900 1900 SMA (External antenna required; see www.campbellsci.com/ order/cr300 for Campbell Scientific antennas.) 3G Frequency Bands 4G Frequency Bands Antenna Connector SIM Interface Radio Output Power Radio Sensitivity Range 3FF (6 position/contacts) Supports SIMs that require 1.8 or 3V. 23 dBmonLTE 24 dBm on UMTS 27 dBm on EDGE 33 dBm on GSM -99.5t0 110.5dBm (10 M) CR300-CELL210 Option -NOTE- Cell Technologies 4G Frequency Bands Antenna Connector Power Consumption - Low Power Mode Power Consumption - Idle Power Consumption - Active SIM Interface Radio Output Power The CR300-CELL210 option is only compatible with a Verizon cellular network. 4G (LTE CAT-1) 700, 850, 1700, 1900, 2100 SMA (External antenna required; see www.campbellsci.com/ order/cr300 for Campbell Scientific antennas.) 5mA 35mA 70mA 3FF (6 position/contacts) Supports SIMs that require 1.8 or 3V. 23dBm on LTE Radio Sensitivity Range -99.5t0 110.5dBm (10 M) CR300-CELL215 Option -NOTE- The CR300-CELL215 option is Intended for use in EMEA countries. Cell Technologies 2G (GSM/GPRS/EDGE) 3G (UMTS/HSPA+) 4G (LTE CAT-1) 2G Frequency Bands 900 and 1800 MHz 3G Frequency Bands 4G Frequency Bands Antenna Connector SIM Interface Radio Output Power Radio Sensitivity Range 850,900, and 2100 MHz 800, 850, 900, 1800, 2100, and
2600 MHz
SMA (External antenna required; see www.campbellsci.com/ order/cr300 for Campbell Scientific antennas.) 3FF (6 position/contacts) Supports SIMs that require 1.8 or 3V. 23 dBmonLTE 24 dBm on UMTS 27 dBm on EDGE 33 dBm on GSM -99.5t0 110.5dBm (10 M) For comprehensive details, visit: www.campbellsci.eu/cr300
-NOTE- Cell Technologies 3G Frequency Bands 4G Frequency Bands Antenna Connector SIM Interface The CR300-CELL220 option is Intended for use in Australia and New Zealand. 4G (LTECAT-1) 3G (UMTS/HSPA+) 850,900, 1900, and 2100 MHz (EC-21AU) 850and 2100 MHz (EC-21AUT) 700, 900, 1700, 1800, 1900, 2100, and 2600 MHz (EC-21AU) 700, 850, 1800, 2100, and 2600 MHz (EC-21AUT) SMA (External antenna required; see www.campbellsci.com/ order/cr300 for Campbell Scientific antennas.) 3FF (6 position/contacts) Supports SIMs that require 1.8 or 3V. Radio Output Power 24 dBm on UMTS 23 dBmonLTE Radio Sensitivity Range -99.5t0 110.5dBm (10 M) CR300-CELL225 Option -NOTE- The CR300-CELL225 option is Intended for use in Japan. Cell Technologies 4G Frequency Bands Antenna Connector SIM Interface Radio Output Power Radio Sensitivity Range 4G (LTE CAT-1) 800 (lower), 800 (upper), 850+, 900, 1800, and 2100 MHz SMA (External antenna required; see www.campbellsci.com/ order/cr300 for Campbell Scientific antennas.) 3FF (6 position/contacts) Supports SIMs that require 1.8 or 3V. 23dBm on LTE -99.5t0 110.5dBm (10 M) B For comprehensive details, visit: www.campbellsci.eu/cr300 CAMPBELL 80Hathern Road, Shepshed, LE129GX UK | +(0)1509 828888 | sale@campbellsci.co.uk | www.campbellsci.eu SCIENTIFIC AUSTRALIA | BRAZIL | CANADA | CHINA | COSTA RICA | FRANCE | GERMANY | INDIA | SOUTH AFRICA | SPAIN | THAILAND | UK | USA ©2023 Campbell Scientific, Ltd. | 04/18/2023