CAPACITIVE PROXIMITY SENSORS
A B C D E F H I J K L M N O P Q R S T CQ35-25NNP-KC1 | CQ CAPACITIVE PROXIMITY SENSORS Illustration may differ
Ordering information
Type Part no. CQ35-25NNP-KC1 6021464 Other models and accessories www.sick.com/CQ Detailed technical data
Features
Dimensions (W x H x D) 35 mm x 69.5 mm x 15 mm Sensing range Sn 4 mm ... 25 mm Safe sensing range Sa 18 mm Installation type Non-flush Switching frequency 50 Hz Connection type Male connector M12, 4-pin Switching output NPN Output function Complementary Electrical wiring DC 4-wire Adjustment Potentiometer, 270° (Sensitivity) Enclosure rating IP67 1) 1) According to EN 60529. Mechanics/electronics Supply voltage 10 V DC ... 36 V DC Ripple ≤ 10 % 1) Voltage drop ≤ 2.5 V DC 2) Current consumption ≤ 10 mA 3) Time delay before availability ≤ 100 ms Hysteresis 4 % ... 20 % Reproducibility ≤ 5 % 4) 5) 1) Of Ub. 2) At Ia max. 3) Without load. 4) Of Sr. 5) Ub and Ta constant. 6) In EMC critical applications, conducted interference levels may lie within the frequency range of the oscillator. This can cause changes to the output signal. (See op- erating instructions.).
2 PROXIMITY SENSORS | SICK Online data sheet | 2017-12-15 16:27:40
Subject to change without notice
CQ35-25NNP-KC1 | CQ CAPACITIVE PROXIMITY SENSORS Temperature drift (of Sr) ± 10 % EMC According to EN 60947-5-2 6) Continuous current Ia ≤ 200 mA Short-circuit protection ✔ Reverse polarity protection ✔ Power-up pulse protection ✔ Shock and vibration resistance 30 g, 11 ms / 10 ... 55 Hz, 1 mm Ambient operating temperature –25 °C ... +75 °C Housing material Plastic, PC Sensing face material Plastic UL File No. NRKH.E191603 1) Of Ub. 2) At Ia max. 3) Without load. 4) Of Sr. 5) Ub and Ta constant. 6) In EMC critical applications, conducted interference levels may lie within the frequency range of the oscillator. This can cause changes to the output signal. (See op- erating instructions.). Reduction factors Note The values are reference values which may vary Metal 1 Water 1 PVC Approx. 0.4 Oil Approx. 0.25 Glass 0.6 Ceramics 0.5 Alcohol 0.7 Installation note Remark Associated graphic see "Installation" A 35 mm B 35 mm Classifications ECl@ss 5.0 27270102 ECl@ss 5.1.4 27270102 ECl@ss 6.0 27270102 ECl@ss 6.2 27270102 ECl@ss 7.0 27270102 ECl@ss 8.0 27270102 ECl@ss 8.1 27270102 ECl@ss 9.0 27270102 ETIM 5.0 EC002715 2017-12-15 16:27:40 | Online data sheet Subject to change without notice PROXIMITY SENSORS | SICK 3
A B C D E F H I J K L M N O P Q R S T CQ35-25NNP-KC1 | CQ CAPACITIVE PROXIMITY SENSORS ETIM 6.0 EC002715 UNSPSC 16.0901 39122230 Installation note A B Connection diagram Cd-006 BN BK WH + (L+) NO NC BU - (M)3
4 PROXIMITY SENSORS | SICK Online data sheet | 2017-12-15 16:27:40
Subject to change without notice
CQ35-25NNP-KC1 | CQ CAPACITIVE PROXIMITY SENSORS Dimensional drawing (Dimensions in mm (inch)) CQ35, connector 35 (1.38) (0.08) 24.5 (0.96) M12 x 1 M12 x 1 (0.47) 8 x 4.5 (0.18) 55 (2.17) 2.5 (0.10) 69.5 (2.74) (0.59) ① Indication LED ② Potentiometer ③ Connection Recommended accessories Other models and accessories www.sick.com/CQ Brief description Type Part no. Plug connectors and cables Head A: female connector, M12, 4-pin, straight Head B: open cable ends Cable: PVC, unshielded, 2 m DOL-1204-G02M 6009382 Head A: female connector, M12, 4-pin, straight Head B: open cable ends Cable: PUR, halogen-free, unshielded, 2 m DOL-1204-G02MC 6025900 Head A: female connector, M12, 4-pin, straight Head B: open cable ends Cable: PVC, unshielded, 5 m DOL-1204-G05M 6009866 Head A: female connector, M12, 4-pin, straight Head B: open cable ends Cable: PUR, halogen-free, unshielded, 5 m DOL-1204-G05MC 6025901 Head A: female connector, M12, 4-pin, angled Head B: open cable ends Cable: PVC, unshielded, 2 m DOL-1204-W02M 6009383 Head A: female connector, M12, 4-pin, angled Head B: open cable ends Cable: PUR, halogen-free, unshielded, 2 m DOL-1204-W02MC 6025903 Head A: female connector, M12, 4-pin, angled Head B: open cable ends Cable: PVC, unshielded, 5 m DOL-1204-W05M 6009867 Head A: female connector, M12, 4-pin, angled Head B: open cable ends Cable: PUR, halogen-free, unshielded, 5 m DOL-1204-W05MC 6025904 2017-12-15 16:27:40 | Online data sheet Subject to change without notice PROXIMITY SENSORS | SICK 5
A B C D E F H I J K L M N O P Q R S T CQ35-25NNP-KC1 | CQ CAPACITIVE PROXIMITY SENSORS Brief description Type Part no. Head A: female connector, M12, 4-pin, straight Head B: - Cable: unshielded DOS-1204-G 6007302 Head A: female connector, M12, 4-pin, angled Head B: - Cable: unshielded DOS-1204-W 6007303
6 PROXIMITY SENSORS | SICK Online data sheet | 2017-12-15 16:27:40
Subject to change without notice
SICK AG | Waldkirch | Germany | www.sick.com SICK At A GlAnCe SICK is one of the leading manufacturers of intelligent sensors and sensor solutions for industrial applica- tions. A unique range of products and services creates the perfect basis for controlling processes securely and efficiently, protecting individuals from accidents and preventing damage to the environment. We have extensive experience in a wide range of industries and understand their processes and require- ments. With intelligent sensors, we can deliver exactly what our customers need. In application centers in Europe, Asia and North America, system solutions are tested and optimized in accordance with customer specifications. All this makes us a reliable supplier and development partner. Comprehensive services complete our offering: SICK lifetime Services provide support throughout the ma- chine life cycle and ensure safety and productivity. For us, that is “Sensor Intelligence.” WOrldWIde preSenCe: Contacts and other locations – www.sick.com