8086608 FESTO | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 3
Technical content
Part number: 8086608 Data sheet Feature Value Dimensions W x L x H 45 mm x 170 mm x 35 mm KC characters KC EMC Fieldbus interface, connection technology M12x1, B-coded as per EN 61076-2-101 Max. power supply 2 x 4 A (external fuse required) Note on degree of protection Unused connections sealed Communication interface, connection technology M8x1, D-coded as per EN 61076-2-114 Fieldbus interface, connection type Plug Permissible voltage fluctuations for electronics/sensors ± 25 % Fieldbus interface, type PROFIBUS Power supply, connection technology M8x1, A-coded as per EN 61076-2-104 Power supply, function Incoming electronics/sensors and load Fieldbus interface, function Incoming bus connection Voltage forwarding, connection technology M8x1, A-coded as per EN 61076-2-104 Intrinsic current consumption at nominal operating voltage load Typically 5 mA Diagnostics via bus Load switch-off Load overvoltage Load undervoltage Electronics/sensors overvoltage Electronics/sensors undervoltage APDD invalid Communication with AP module interrupted Relative air humidity 5 - 95 % Non-condensing Fieldbus interface, galvanic isolation yes Communication interface, connection type 2x socket Intrinsic current consumption at nominal operating voltage for electronics/sensors Typically 80 mA Power supply, type of connection Plug Voltage forwarding, connection type Socket Communication interface, function System communication XF20 OUT / XF21 OUT Fieldbus interface, protocol PROFIBUS DP-V1 Configuration support GSD file Max. cable length 50 m system communication Communication interface, protocol AP-COM 6/8/21 - Subject to change - Festo AG & Co. KG 1/3
Fieldbus interface, transmission rate 9.6 kbit/s 19.2 kbit/s 93.75 kbit/s 187.5 kbit/s 500 kbit/s
1.5 Mbit/s
3 Mbit/s
6 Mbit/s
12 Mbit/s
Diagnostics via LED Buffer error LED (BF) Diagnostics per module Power supply for electronics/sensors Load power supply System diagnostics Maintenance required Permissible voltage fluctuations load ± 25 % Communication interface, shielding yes Voltage forwarding, function Outgoing electronics/sensors and load Fieldbus interface, number of poles/wires 5 Max. address capacity outputs 244 byte Voltage forwarding, number of pins/wires 4 Nominal operating voltage DC for electronics/sensors 24 V Power supply, number of pins/wires 4 Max. address capacity inputs 244 byte Communication interface, number of pins/wires 4 Nominal operating voltage DC load 24 V Power failure buffering 10 ms Max. number of modules 56 Note regarding operating voltage SELV/PELV fixed power supplies required Note voltage drop Fieldbus interface 2, connection technology M12x1, B-coded as per EN 61076-2-101 Fieldbus interface 2, function Bus connection, forwarding Fieldbus interface 2, galvanic isolation yes Fieldbus interface 2, type PROFIBUS Fieldbus interface 2, protocol PROFIBUS DP-V1 Fieldbus interface 2, connection type Socket Note on fieldbus interface Terminating resistor on socket possible Fieldbus interface 2, transmission rate 1.5 mbps 12 mbps 187.5 kbps 19.2 kbps 3 mbps 500 kbps 6 mbps 9.6 kbps 93.75 kbps Fieldbus interface 2, number of poles/wires 5 Type code CPX-AP-I Reverse polarity protection yes CE marking (see declaration of conformity) As per EU EMC directive Corrosion resistance class (CRC) 1 - Low corrosion stress Storage temperature -40 °C ... 70 °C Degree of protection IP65 IP67 Ambient temperature -20 °C ... 50 °C Certification RCM compliance mark Product weight 186 g Type of mounting With through-hole Note on materials RoHS-compliant 6/8/21 - Subject to change - Festo AG & Co. KG 2/3
Die-cast zinc, nickel-plated 6/8/21 - Subject to change - Festo AG & Co. KG 3/3