CPS-H640 ADLINK | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 2
Technical content
Features
- PICMG
2.11 CompactPCI
- 6U CompactPCI 8HP form factor
- PICMG® 2.11 47-pin CompactPCI in-rack power module interface
- 400 W DC output
- Active PFC (Power Factor Correction) meets IEC1000-3-2 Harmonic Correction
- Internal OR-ing Diodes for N+1 redundancy
- Hot swappable
- Active current sharing
- EN 55022 & FCC Class A
- Supports remote ON/OFF
- Supports power failure signal & degradation signal Specifications Model Name: cPS-H640/AC PICMG® Standards PICMG® 2.11 CompactPCI 47-pin Power Interface compliant Form Factor: 6U cPCI (233.33 x 160 mm), 2-slot (8HP) wide Input Voltage: 100-240 10% V AC Input Frequency: 50-60 5% Hz Input Current: 5.1 A @115 V AC / 2.5 A @ 230 V AC Inrush Current : < 30 A @230 V AC Model Name: cPS-H640/48 PICMG® Standards PICMG® 2.11 CompactPCI 47-pin Power Interface compliant Form Factor: 6U cPCI (233.33 x 160 mm), 2-slot (8HP) wide Input Voltage: 36-72 V DC Input Frequency: DC Input Current: 12A @ 48 V DC Inrush Current : N/A Power Factor Correction (PFC, only for AC) Typical 0.97-0.99 Meets Harmonic Correction IEC1000-3-2 Output Voltage/Current 5 V: Typ. 40.0 A, Max. 50.0 A +12 V: Typ. 10.0 A, Max. 15.0 A -12 V: Typ. 2.0 A, Max 5.0 A ** Max. load is the continuous operating load of each rail individually. The Max. load of each rail cannot be drawn from all outputs simultaneously. Output Voltage Minimum Load
1.0 A @ +5 V
Output Wattage: Typical 400 W continuous Output Wattage: Typical 0.1% Load Regulation: Typical 1-3% Ripple 50 mV @ +5 V and 3.3 V outputs, 120 mV @ +12V and -12V outputs Hold-up Time : 10 ms after power fail signal Efficiency: Typical 79-83% Output voltage sense and current sharing: Available at 5 V , 3.3 V and +12 V outputs N+1 Redundancy: Installed with internal OR-ing diodes at all outputs for N+1 redundancy operation Remote ON/OFF: Available at [INH#] & [EN#] Power Failure Signal Available at [FAL#] pin Power Degradation Signal Available at [DEG#] pin Protections Over Temperature Protection (OTP): 70˚C Over Current Protection (OCP): Installed at each rail Over Load Protection (OLP): Typical 120% max. load, fully protected against output overload or short circuit. Over Voltage Protection (OVP): Built-in at all outputs Status LED < Green LED > [POWER] means valid input voltage < Amber LED > [FAUL T] means a critical fault Earth Leakage < 0.9mA @ 230 V AC >
www.adlinktech.com All products and company name listed are trademarks or trade names of their respective companies. Updated Mar. 10, 2017. ©2017 ADLINK Technology, Inc. All Rights Reserved. All specifications are subject to change without further notice.
Ordering Information
- cPS-H640/AC PICMG 2.11 47-Pin Hot-Swap Redundant 6U CompactPCI 8HP
400 W Power Module with Universal AC Input
- cPS-H640/48 PICMG 2.11 47-Pin Hot-Swap Redundant 6U CompactPCI 8HP
400 W Power Module with 36-72 V DC Input
Operating Temp. 0˚C to 70˚C (0˚C to +40˚C at full load with specified air flow. De-rates linearly to 50% at +70˚C.) Storage Temp. -20˚C to +85˚C Humidity 20% to 90% non-condensing Shock
15 G peak-to-peak, 11 ms duration, non-operation
Operation: 1.88 Grms, 5-500 Hz, each axis Cooling Requirement: Minimum 20 CFM airflow is required for typical full rating power Compliance IEC950, EN 55022, FCC Class A, IEC60950 Class I