CPD250 POWER-ONE | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 4

Technical content

The DC input CPD250-4530 is the first in a series of hot- swap, CompactPCI® power supplies that are fully compliant to the PICMG® 2.11 Power Interface Specification using a standard Positronic 47-pin connector. Extra-high current density using innovative Power-One EDGE technology allows this unit to deliver up to 40 amperes on both the +5 and +3.3 volt outputs at 50ºC. Remote sense and active current share on the +5, +3.3 and +12 volt outputs along with ORing FETs allow these units to be used in redundant, hot-swap applications. The CPD250-4530 is feature rich, meets international safety standards, and displays the CE Mark for the Low Voltage Directive (LVD).

FEATURES

  • Wide Input Range (36-75 VDC)  Delivers 40A for the +5V and +3.3V Outputs (No Restrictions)  Single-wire Current Share on Outputs V1, V2, and V3  Remote Sense on Outputs V1, V2, and V3  Overtemperature, Overvoltage, and Overcurrent Protection  Input Good and Power Fail LED Indicators  Power Fail and Temperature Warning Signals  Inhibit and Enable Inputs  Fully Compliant to PICMG ® 2.11 CompactPCI® Specification  Extra-High Current Density in Industry-Standard 3U x 8HP x 160mm Package DC INPUT MODEL SELECTION CHART MODEL OUTPUT ADJUSTMENT OUTPUT LINE LOAD RIPPLE & NOISE VOLTAGE RANGE CURRENT REGULATION REGULATION %pk-pk (NOTE 1) CPD250-4530 +3.3V N/A 40A 0.5% 1% 2% NOTES: 1) Maximum peak-to-peak expressed as a percentage of output voltage, 20 MHz bandwidth. INPUT SPECIFICATIONS PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Input Voltage - DC Continuous input range. 36 75 VDC Hold-up Time From 48 VDC Input. 4 mS Input Current At full rated load; 36 VDC, 48 VDC. 7.6, 5.4 A Input Protection Non-user serviceable, internally-located input line fuse. Inrush Surge Current Internally limited by thermistor and electronic switch. 12 A Operating Frequency Switching frequency of main output transformer. 125 145 kHz Input Transient Protection Varistor. CompactPCI and PICMG are registered trademarks of the PCI Industrial Computer Manufacturers Group. REV. 10/25/01 Advanced Product Release

PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Efficiency Full rated load, 48 VDC Input. 80 % Minimum Load; V1, V2, V3 Minimum load required to maintain regulation with no load on V4. None A Minimum Load, V3 Minimum load on V3 required to maintain regulation on V4. 50% OF V4 Load A Ripple and Noise Full load, 20 MHz bandwidth. See Model Selection Chart Output Power 250 LFM forced-air cooling. 200 W Output Power 400 LFM forced-air cooling. 250 W Overshoot /Undershoot Output voltage overshoot/undershoot at turn-on. 0 % Regulation Varies by output. Total regulation includes: line changes over the specified See Model Selection Chartinput range, changes in load starting at 50% load and changing to 100% load. Turn-on Delay Time required for initial output voltage stabilization. 150 ms Initial Setting Accuracy ±1% INTERFACE SIGNALS AND INTERNAL PROTECTION PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Overvoltage Protection Latch style overvoltage protection. 120 130 %Vnom Overload Protection Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condi tion. Overtemperature Protection System shutdown due to excessive internal temperature, automatic reset. Power Fail (FAL#) TTL compatible signal, open collector active low signal. Indicates any output below 90% and/or a low input <36VDC. Current Share Accuracy of shared current with up to 6 parallel units. Single wire current share on V1, V2, and V3. 10 % Remote Sense Available on V1, V2, and V3. Total voltage compensation for cable losses with 150 mV respect to the main output. Inhibit (INH#) TTL-compatible signal inhibited with GND or TTL "0". Enable (EN#) Contact closure to external ground to start unit. On shortest pin (last make, first break). Overtemperature Warning (DEG#) Provides warning when power supply temperature exceeds rating. TTL-compatible open. Front Panel LED Status Indicators Input OK (Green), Output Failure (Red). SAFETY, REGULATORY, AND EMI SPECIFICATIONS PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Agency Approvals UL1950. cUL1950. Approved EN60950 (TÜV). Dielectric Withstand Voltage Input to Output per EN60950. 4243 VDC Electromagnetic Interference EN55022 / CISPR 22 - Conducted. A Radiated. A Class ESD Susceptibility Per EN61000-4-2, level 4. 8 kV Radiated Susceptibility Per EN61000-4-3, level 3. 10 V/M EFT/Burst Per EN61000-4-4, level 3. ±2 kV Input Surge Per EN61000-4-5, level 3. Line to Line 1 kV Line to Ground 2 Conducted Disturbance Per EN61000-4-6, level 2. 3V Insulation Resistance Input to Output. 10 M /H9024 ENVIRONMENTAL SPECIFICATIONS PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Altitude Operating. 10k ASL Ft. Non-Operating. 40k ASL Ft. Operating Temperature With 400 LFM forced-air cooling At 100% load: 0 50 °C Derate linearly above 50°C by 2.5% per °C. At 50% load: 70 °C Storage Temperature -40 85 °C Relative Humidity Non-Condensing. 5 95 %RH Shock Peak acceleration. 20 G PK Vibration Random vibration, 10 Hz to 2 kHz, 3 axis. 6 G RMS CPD SERIES - 250 WATT

6.671" (169.4mm) 1.6" (40.6mm) 3.74" (95.0mm) 3.937" (100.0mm) 5.067" (128.7mm) 0.507" (12.88mm) 0.26" (6.61mm) Tolerances ± 0.012" (0.3mm) unless otherwise indicated. 3U x 8HP WEIGHT: 1.75 lb (0.8 kg) CPD SERIES - 250 WATT

PIN PIN-LENGTH SIGNAL DESCRIPTION PIN PIN-LENGTH SIGNAL DESCRIPTIONTYPE (NOTE 1) NAME TYPE (NOTE 1) NAME 1-4 M V1 V1 OUTPUT 32 M NC NOT CONNECTED 5-12 M RTN V1 and V2 RETURN 33 M V2 SENSE V2 REMOTE SENSE 13-18 M V2 V2 OUTPUT 34 M S RTN SENSE RETURN

19 M RTN V3 RETURN 35 M V1SHARE V1 CURRENT SHARE

20 M V3 V3 OUTPUT 36 M V3SENSE V3 REMOTE SENSE

21 M V4 V4 OUTPUT 37 M NC NOT CONNECTED

22 M RTN SIGNAL RETURN 38 M DEG# DEGRADE SIGNAL

23 M RESERVED RESERVED 39 M INH# INHIBIT

24 M RTN V4 RETURN 40 M NC NOT CONNECTED

25 M NC NOT CONNECTED 41 M V2SHARE V2 CURRENT SHARE

26 M RESERVED RESERVED 42 M FAL# FAIL SIGNAL

27 S EN# ENABLE 43 M NC NOT CONNECTED

28 M NC NOT CONNECTED 44 M V3SHARE V3 CURRENT SHARE

29 M NC NOT CONNECTED 45 L CGND CHASSIS GROUND

30 M V1SENSE V1 REMOTE SENSE 46 M +DCIN + DC INPUT

31 M NC NOT CONNECTED 47 M -DCIN - DC INPUT

NOTE 1) L = Long-Length Pins, M = Medium-Length Pins, S= Short-Length Pins CPD SERIES - 250 WATT NUCLEAR AND MEDICAL APPLICATIONS Power-One products are not authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the President of Po wer-One, Inc. TECHNICAL REVISIONS The appearance of products, including safety agency certifications pictured on labels, may change dependin g on the date manufactured. Specifications are subject to change without notice.