CPC12PN-T1-001 E-T-A | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 11

Technical content

INTELLIGENT POWER DISTRIBUTION SYSTEM CPC12PN CPC12PN-T1-001 The intelligent CPC12 ControlPlex® system is the perfect solution for the machine building industry. The system combines the well- proven quality of a DC 24 V overcurrent protection with a PRO- FINET communication function. It features permanent measuring data recording, analysing and processing. This provides the requi- red transparency to detect changes in the production process at an early stage and initiate corrective actions in time. The integral web server of the CPC12 bus controller allows direct access to the data of the DC 24 V power distribution. All measuring data and status information can be accessed even without using the /f_ield bus interface. /uni00A0 CPC12PN-T1-001 INTELLIGENT POWER DISTRIBUTION SYSTEM CPC12PN TYPICAL FEATURES YOUR BENEFITS

  • Control, diagnosis and monitoring via PROFINET
  • Devices including supply module, overcurrent protection, power distribution module and bus controller
  • No accessories required for connecting the components
  • Fully-fledged PROFINET communication interface
  • Can be updated via fully-fledged Ethernet communication interface (web server)
  • Adjustable configuration of up to 32 channels with 16 devices
  • Increased m achine uptim e through clear failure detection and sta- ble voltage supply
  • S aves costs as no further accessories are required
  • S aves 50 % tim e through innovative and flexible m ounting and connection technology
  • Reduces dow ntim es through quick trouble-shooting TYP. APPLICATIONS APPROVALS / CERTIFICATIONS Automation, machine building industry, process industry WEB LINKS COMPLIANCE Further information, W eb server instruction m anual, Mounting and operation (videos), Operating instructions, International approvals, Technical basics, REACH , RoHS , Contact global.e-t-a.com 1326

INTELLIGENT POWER DISTRIBUTION SYSTEM CPC12PN GENERAL INFORMATION SAFETY AND INSTALLATION INSTRUCTIONS Installation must be done by a qualified electrician.

  • The CPC12 bus controller is only intended for use with safety extra-low voltage (=24 V DC).
  • Connection to higher or not selectively protected voltages can cause harmful conditions or damage.
  • Only the intended circuit protectors must be used.
  • The device must only be supplied with power after proper installation.
  • When a circuit protector has tripped and before the reset, the cause of the failure (short circuit or overload) must be reme- died.
  • The national standards (e.g. in Germany DIN VDE 0100) for installation and selection of the feed and return cables must be observed. For convenient adjustment and configuration by means of projecting software a generic station description /f_ile (GSDML /f_ile) is m ade available for dow nloading on the E-T-A hom epage.
  • The CPC12 bus controller is not suitable to control safety-relevant or functional safety applications.
  • Please observe separate CPC12 instruction manual. Electrostatically sensitive sub-assemblies can be destroyed by voltages far below the human perception threshold. These voltages already occur if you touch a component or electrical terminals of a component without being electrostatically di- scharged. The damage of a sub-assembly caused by an overvoltage is often not immediately recognised, but will be noti- ced only after a longer operating time. Note: When wiring and connecting to the PROFINET bus system the installation and wiring regulations of the PROFIBUS User Or- ganisation (PNO) must be observed. Mounting instruction: Mounting or actuation of the REX connector arm must only be effected at dead-voltage. For start-up the REX connector arm must be closed. A maximum of 40 modules can be connected in series. Note: Data sheets for the electronic circuit protectors in the REX portfolio must be taken into account. Specifically the no- tes on DIN rail mounting/dismounting, installation position, installation space, sealing and application examples must be observed. FURTHER INFORMATION CONTROLPLEX ® SYSTEM CPC12 https://global.e-t-a.com/c18179/ TECHNICAL DATA (T u = +25 °C, Ub = DC 24 V) ELECTRICAL DATA Rated voltage Un DC 24 V Operating voltage Ub 18...30 V Quiescent current I0 Typ. 75 m A Reverse polarity protection Yes Insulation co-ordination (EN IEC 60664)0.5 kV Overvoltage category: II Pollution degree: 2 Reinforced insulation in the actuating area OVERVIEW OF COMMANDS IN THE COM MODE Writing/reading the device configuration (parameters)
  • Current limit value 50 ... 100 %
  • Rated current, writing of the rated current only possible with the REX12D-TE and REX22D-TE devices. Reading static device information • CPC12 device type & circuit protectors
  • CPC12 serial number & circuit protectors
  • CPC12 hardware version & circuit protectors
  • CPC12 software version & circuit protectors Reading dynamic device information / measuring values
  • CPC12 device status
  • Internal cycle time
  • Error memory
  • Trip counter
  • Reason of last tripping
  • Device status / event of the circuit breakers
  • Load voltage ACTUAL / MIN / MAX / MEDIUM VALUE global.e-t-a.com 1326

INTELLIGENT POWER DISTRIBUTION SYSTEM CPC12PN

  • Load current: ACTUAL / MIN / MAX / MEDIUM VALUE
  • Supply voltage
  • Total current Control commands • S w itch on/off or reset load output
  • Reset trip counter
  • Set parameters to factory settings MECHANICAL DATA Mounting dimensions (WxHxD) 23 x 80 x 98.5 mm (tolerances according to DIN ISO 286 part 1 IT13) Mass Approx. 70 g Mounting data DIN rail according to EN 60715-35x7.5 MOUNTING VALUES XD1 terminal Cable cross section [mm²]Cable cross section [AWG] Stripping length [mm] rigid 0.2…1.5 24…16 8 flexible 0.2…1.5 24…16 8 flexible w ith w ire end ferrule w ith plastic sleeve 0.2…0.75 24…19 8 flexible w ith w ire end ferrule w ithout plas- tic sleeve 0.2…1.5 24…16 8 Interfaces PROFINET interface (XF1, XF2) RJ45) connection to PROFINET bus system ETHERNET interface (X1) RJ45; communication interface to the web server IP-reset momentary switch Resetting the IP address (X1 interface) by pushing the button for min. 3 s AMBIENT CONDITIONS Ambient temperature -30...+60 °C (without condensation, cf. EN 60204-1) Storage temperature -40...+70 °C Mounting temperature +5...+60 °C Damp heat Test according to IEC 60068-2-78, test cab. climate class 3K3 to EN60721 96 h at 95 % rel. hum idity/40 °C Vibration Test according to IEC 60068-2-6 test Fc 5 g IP code standard IEC 60529 Actuating area IP code (standard) IP30 Terminal area IP code (standard) IP20 EMC requirements - emitted interfe- rence (EMC directive) EN 61000-6-3 EMC requirements - resistance to dis- turbances (EMC directive) EN 61000-6-2 Operating altitude 2,000 m a. sea level (SL) 3,000 m a. SL up to +55 °C 4,000 m a. SL up to +50 °C Maximum ambient pressure during ope- ration 4 bar above atmospheric pressure FURTHER INFORMATION CPC12EN/MB/PN - VISUAL INDICATION OF THE RJ45 INTERFACES X1, XF1 AND XF2 Link (Ethernet cable monitoring) Operating mode LED LNK Link available G reen No link available OFF Activity (Ethernet communication activity) Operating mode LED ACT Activity available Orange flashing global.e-t-a.com 1326

INTELLIGENT POWER DISTRIBUTION SYSTEM CPC12PN No activity available OFF CPC12PN - VISUAL INDICATION OF THE OPERATING CONDITIONS Operating mode LED US1 LED US2 LED BF LED SF Bus fault G reen G reen Red OFF System fault G reen G reen OFF Red Firmware update OFF OFF OFF OFF PROFINET connection active G reen G reen OFF OFF n.a. not applicable ORDERING NUMBER CODE C P C P N T

1 TYPE NUMBER

CPC12 Bus controller for REX12D and REX22D with PT connection technology

2 VERSION: FIELDBUS SYSTEM

EC EtherCAT (connection: 2x RJ45 socket) EN EtherNet/IP (connection: 2x RJ45 socket) MB Modbus TCP (connection: 2x RJ45 socket) PN PROFINET (terminal: 2x RJ45 socket)

3 MOUNTING

4 ELBUS CONNECTION

1 Communication with the REX12D and REX22D circuit protectors

5 PRODUCT VERSIONS

001 Marking version

6 ATEX APPROVAL

[No entry if no ATEX approval] E ATEX/IECEx approval Further ordering examples: - CPC12 PN - T 1 - 001 - E (with ATEX approval) APPROVALS APPROVALS Approval authority Test standard File Certificate No. Rated voltage [V] UL UL 2367 UL 1310 NEC Class2 E306740 DC 24 UL UL 508 listed CSA C22.2 No. 14, CSA C22.2 No. 107.1 E492388 DC 24 UL UL 121201 (C lass I, Division 2, G roups A, B, C, D) CSA C22.2 No. 213 E543007 DC 24 global.e-t-a.com 1326

INTELLIGENT POWER DISTRIBUTION SYSTEM CPC12PN Bureau Veritas ATEX 2014/34/EU EN 60079-0 EN 60079-7 EN 60079-15 EPS 23 ATEX 1 262 U DC 24 IECEx IEC 60079-0 IEC 60079-7 IEC 60079-15 IECEx EPS 23.0072U DC 24 UKEX EN IEC 60079-0 EN IEC 60079-7 EN IEC 60079-15 EPS 23 UKEX 1 263 U DC 24 Find further information about approvals here: https://www.e-t-a.de/approvals_en APPROVALS Operating temperature code T4 - This equipm ent is suitable for use in C lass I, Division 2, G roups A, B, C and D or non-hazardous locations only. T5 W ARNING - EXP LO S IO N HAZARD: - Do not connect or disconnect equipm ent unless pow er has been rem oved or the area is know n to be non-hazardous. This device is OPEN type equipment that must be used within a suitable end-use system enclosure, the interior of which is only accessible using a tool. The suitability of the enclosure must be checked by the local authority at the time of installation. W iring to or from this device, w hich enters or leaves the system enclosure, m ust utilize w iring m ethods suitable for Class I, Division 2 Hazardous Locations, as appropriate for the installation. DIMENSIONS DIMENSIONAL DRAWING CPC12XX-TX-XXX global.e-t-a.com 1326

INTELLIGENT POWER DISTRIBUTION SYSTEM CPC12PN INSTALLATION INSTRUCTIONS PREFERRED MOUNTING POSITION IN THE REX SYSTEM HORIZONTAL SCHEMATIC DIAGRAMS CPC12PN PIN ASSIGNMENT global.e-t-a.com 1326

INTELLIGENT POWER DISTRIBUTION SYSTEM CPC12PN APPLICATION EXAMPLES MOUNTING / DISMOUNTING ON DIN RAIL IN THE REX SYSTEM MOUNTING / EXPANSION ON DIN RAIL IN THE REX SYSTEM global.e-t-a.com 1326

INTELLIGENT POWER DISTRIBUTION SYSTEM CPC12PN EXCHANGE IN / DISMOUNTING FROM THE REX SYSTEM NETWORK SEALING OF THE REX SYSTEM global.e-t-a.com 1326

INTELLIGENT POWER DISTRIBUTION SYSTEM CPC12PN DISTANCES BETWEEN CABLE DUCT AND LEVER IN THE REX SYSTEM APPLICATION EXAMPLE global.e-t-a.com 1326

INTELLIGENT POWER DISTRIBUTION SYSTEM CPC12PN CPC12EN, CPC12MB, CPC12PN APPLICATION EXAMPLES DISTANCES BETWEEN CABLE DUCT AND LEVER IN THE REX SYSTEM global.e-t-a.com 1326

INTELLIGENT POWER DISTRIBUTION SYSTEM CPC12PN ACCESSORIES REQUIRED ACCESSORIES 0EM120007183 The EM 1 2-T supply m odule receives the DC 24 V supply voltage, e.g. fFrom a switched mode power supply, and distributes it to the mounted circuit pro- tectors via the integral connector arm of the REX1 2-T. The potential-free S i auxiliary contact in the EM12-T indicates errors and faults detected by the circuit protectors, e.g. to a superordinate control unit (CPU). /uni00A0 EM 1 2-T0 0 -0 0 0 -DC 24V-40 A supply m odule (w ithout signalling) OPTIONAL ACCESSORIES EM12-T (LINE) The EM 1 2-T supply m odule receives the DC 24 V supply voltage, e.g. fFrom a switched mode power supply, and distributes it to the mounted circuit pro- tectors via the integral connector arm of the REX1 2-T. EM12-T (GND) The EM12-T supply module receives the DC 0 V (GND) of the supply voltage, e.g. from a sw itched m ode pow er supply, and distributes it to the m ounted potential distribution m odules via the integral connector arm of the P M 1 2-T. OPTIONAL ACCESSORIES FROM REX12D-T W ith the com pact and flexible REX system , E-T-A offers a sophisticated DC

24 V solution for protection and power distribution in mechanical and plant

engineering - consisting of power supply, overcurrent protection, distributi- on and bus controller. The REX12D-T circuit protector provides selective pro- tection, reacts faster than the switch mode power supply to short circuits or overloads and reliably sw itches on capacitive loads up to 20 ,0 0 0 µF. Available w ith fixed and adjustable current ratings from 1 A to 1 0 A, it fulfils not only UL508listed and NEC Class 2 but also exclusively EN 60204-1 for line pro- tection. All REX12D-T modules support BASE and COM mode - with simple message signalling or extensive communication and diagnostics just as re- quired. The operating mode is automatically recognised. REX22D-T E-T-A’s com pact and flexible REX system represents a com prehensive DC 24 V protection- and power distribution solution for the machine building indus- try. It is a perfectly harmonised system including power supply, overcurrent protection, power distribution and bus controller. The REX22D-T selectively protects all DC 24 V load circuits up to 20 A and li- nearly limits the output current when switching on or before tripping. The li- mitation limits the rated current in the event of a short circuit. This allows ef- fective and calculable protection of switch mode power supplies, even with small power reserves. All information and data given on our products are accurate and reliable to the best of our knowledge, but E-T-A does not accept any responsibility for the use in applications which are not in accordance with the present specification. E-T-A reserves the right to change specifications at any time in the interest of technical improvement. Dimensions are subject to change without notice. Please enquire for the latest dimensional drawing with tolerances if required. All dimensions, data, pictures and descriptions are for information only and are not binding. Amendments, errors and omissions excepted. Ordering part numbers may differ from the device marking. global.e-t-a.com 1326