www.e-t-a.de Bus Controller CPC10PN (ControlPlex®) 1922

Description

The bus controller CPC10xx-Tx is the central communication sub-assembly of the intelligent power distribution systems type ControlPlex®. The CPC10 allows communication with up to ninety- six electronic circuit protectors ESX50D-S1xx. It enables read-out of the electronic circuit protectors' status, their corresponding operation data such as the present load current and the load voltage and it enables control and parameterising of the devices. In addition the CPC10 ensures the connection between the circuit protectors and superordinate control level by means of the integral field bus interface. Its internal ELBus® interface allows realisa- tion of the connection to the power distribution boards and the plugged-in electronic circuit protectors type ESX50D-S. The number of ELBus® interfaces can be selected for two different versions. The bus controller CPC10xx-T1 can be used with one ELBus® interface, the bus controller CPC10xx-T4 can be used with four ELBus® interfaces. The selection of the corresponding bus controller depends on the required system expansion stage and offers the customer the choice between the connection of one to four power distribution boards and thus the possibility to communicate with up to 24 or even 96 electronic circuit protectors type ESX50D-S. The CPC10 enables the complete access to all requested parameters of the electronic circuit protector, its control and the visualisation of its status data. This is made available at the field bus interface for the superordinate control unit and also at the USB service interface for the operation on site. The combination of the bus controller CPC10 with the power dis- tribution board SVS201-PWR-xx and the plugged in electronic circuit protectors ESX50D-S1xx offers a fully parameterisable protection of the DC 24 V circuits and ensures the selective overcurrent protection of sensors and actuators, of decentralised peripheral sub-assemblies etc. and their supply cables. It is therefore ideally suited to the use in machine construction and process control, in the chemical, pharmaceutical and foodstuffs industry, in building automation, steel production and car manufacturing. ControlPlex® reduces wiring time, increases system availability and enhances diagnostic functions. Features and Benefits l Integral DC 24 V power distribution system for power distribution and overcurrent protection l Complete diagnosis and parameterising of the entire power distribution system l For electronic circuit protectors ESX50D-S100 / -S110 l Variable configuration of the connection with up to 96 electronic circuit protectors l Fully featured communication interfaces such as PROFIBUS-DP , PROFINET etc. l Service and maintenance interface via USB terminal l Integral memory HISTOMEMO for overload and short-circuit diagnosis of the load circuits l Profitability through considerably reduced wiring time l Reduction of planning, design and installation time l Ease of maintenance, diagnosis and system extension CPC10PN-T1 CPC10PN-T4 Technical data (Tamb = 25 °C, UB = DC 24 V) Suitable for the following types: Distribution rails Electronic circuit protector Electronic circuit protector SVS201-PWR-xx ESX50D-S100 (completely parameterisable by means of the CPC10) ESX50D-S110 (current rating adjustable by means of the rotary switch on the circuit protector, otherwise completely parameterisable via the CPC10) Application: Intelligent DC 24 V Power Distribution Systems Line entry load module (X41) Rated voltage DC 24 V (18 ... 32 V) Current rating typically 60 mA Terminals 4 x screw terminals, (+/+/0V/0V) cable cross section max. 2.5 mm2 flexible with wire end ferrule (with plastic sleeve) 0.25 – 1.5 mm2 flexible with wire end ferrule (without plastic sleeve) 0.25 – 2.5 mm2 stripping length 7 mm tightening torque 0.5 to 0.6 Nm ELBus® termination to connect the power distribution boards X51 COM-1: connection for the first power distribution boards SVS201-PWR-xx cable length max. 2m typically H07V-K 1.5 mm² female connector 1: Data line ELBus® ELB female connector 2: ELBus® DC +24V female connector 3: ELBus® GND only with CPC10PN-T4 X52 COM-2: connection for the second power distribution board SVS201-PWR-xx cable length max. 2m typically H07V-K 1.5 mm² female connector 1: Data line ELBus® ELB female connector 2: ELBus® DC +24V female connector 3: ELBus® GND only with CPC10PN-T4 X53 COM-3: connection for the third power distribution board SVS201-PWR-xx cable length max. 2m typically H07V-K 1.5 mm² female connector 1: Data line ELBus® ELB female connector 2: ELBus® DC +24V female connector 3: ELBus® GND only with CPC10PN-T4 X54 COM-4: connection for the fourth power distribution board SVS201-PWR-xx cable length max. 2m typically H07V-K 1.5 mm² female connector 1: Data line ELBus® ELB female connector 2: ELBus® DC +24V female connector 3: ELBus® GND

www.e-t-a.de Bus Controller CPC10PN (ControlPlex®) 1922 Conformity and approvals Markings l CE l PNO certification CE Declaration of Conformity with the presently valid EMC Directive Caution Caution: Electrostatically sensitive sub-assemblies can be destroyed by voltages far below the human perception threshold. These voltages already occur if you touch a component or electrical terminals of a sub-assembly without being electrostatically discharged. The damage of a sub-as- sembly caused by an overvoltage is often not immediately recog- nised, but will be noticed only after a longer operating time. Order numbering code Type CPC10 Bus controller for ControlPlex® Board for SVS201-PWR-xx with ESX50D-S100 / -S110 l Integral DC 24 V power distribution system l For max. 96 psc electronic circuit protectors type ESX50D-S xxx l Direct field bus connection l Service and maintenance interface via USB l with physical isolation of CPC10 and SVS201-PWR Version: Bus system PB PROFIBUS–DP (connection D-Sub, 9-pole, connector) PN Profinet IO (connection: 2 x RJ45 female connector) Version - number of power distribution boards to be connected T1 one power distribution board SVS201-PWR can be connected T4 up to four power distribution boards SVS201-PWR can be connected Versions

001 Marking

CPC10 PN - T1 - 001 ordering example Technical data (Tamb = 25 °C, UB = DC 24 V) Technical data (Tamb = 25 °C, UB = DC 24 V) USB service and maintenance interface (-X61) X61 connection to a PC for communication with the user software cable length max. 2.5 m Type: USB-2.0 Type B PROFINET interface (-X81, -X82) with integral switch X81 Connection to bus system PROFINET Type: RJ45 When wiring and connecting to the bus system PROFINET the installation and wiring regulations of the PROFIBUS User Organisation (PNO) have to be observed. X82 Connection to bus system PROFINET Type: RJ45 When wiring and connecting to the bus system PROFINET the installation and wiring regulations of the PROFIBUS User Organisation (PNO) have to be observed. Communication via PROFINET Max. input process data: 256 Byte Max. output process data: 256 Byte If all I/O data (total current, status, current, voltage) are fully used, max. 48 x ESX50D-S can be connected. If total current and status are used, max. 94 x ESX50D-S can be connected. Status indication of the CPC10PN-Tx LED "PWR" LED "CE" LED "CM" LED lighted with supply voltage applied Status indication shows status of bus controller CPC10 LED colours: red, green, yellow, orange The LED shows the status of the communication between the communication unit and electronic circuit protector. LED colours: red, green, yellow, orange LED "NS" LED "MS" Indication of network status of the communication of the internal communication module status to the PROFINET master LED colours: red, green, yellow, orange Status indication of the internal communication module LED colours: red, green, yellow, orange General data Mounting method rail mounting to EN 60715 - 35 x 7.5 Temperature range 0...50 °C (without condensation) Storage temperature -20…+70 °C Housing material plastic Protection class terminals IP20 EN60529 Dielectric strength DC 32 V (load circuit) Dimensions see dimensional drawing (tolerances to DIN ISO 286 part 1 IT13) Mass CPC10PN-T1 approx. 125 g CPC10PN-T4 approx. 185 g EMC • EN 61000-6-2 2005 Electromagnetic compatibility (EMC) part 6-2: Basic standards - noise immunity for industrial areas

  • EN 61000-6-4 2007+A1:2011 Electromagnetic compatibility (EMC) – part 6-4: Basic standards – noise immunity for industrial areas Vibration 3 g, test to IEC 60068-2-6 test Fc Operating mode Indication of operating mode LED CM LED CE LED PWR SVS_SYSTEMINIT yellow yellow green SVS_ERROR_CRITICAL yellow red green SVS_ERROR_UNCRITICAL yellow flashing red green SVS_PARAMETERIZATION (1) SVS_STANDALONE yellow OFF green SVS_NORMAL_MODE green OFF green All dimensions without tolerances are for reference only. E-T-A reserves the right change specifications at any time in the interest of improved design, performance and cost effective- ness, the right to make changes in these specifications without notice is reserved. Product markings may not be exactly as the ordering codes. Errors and omissions excepted.

www.e-t-a.de Bus Controller CPC10PN (ControlPlex®) 1922 Bus Controller CPC10PN (ControlPlex®) Notes for installation Terminal selection Dimensions CPC10PN-T1-xxx Mounting position Dimensions CPC10PN-4-xxx Application example for PROFINET usage l The CPC10 is only intended for use with safety extra-low voltage (=24 V DC). l Connection to a higher or not reliably disconnected voltage can cause hazardous conditions or damages. l Only the intended power distribution boards must be used. l The technical data of the used circuit protectors have to be observed. l The entire power distribution system must only be installed by qualified personnel. l Only after expert installation must the device be supplied with power. l After tripping of the circuit protector and before reset, the cause of the failure (short circuit or overload) must be remedied. l The national standards (e.g. for Germany DIN VDE 0100) have to be observed for installation and selection of feed and return cables. l 0 V potential load and control voltage connected. l For convenient adjustment and configuration by means of projecting software a master data file (GSDML file) will be made available for downloading from the E-T-A homepage. Please observe the separate user manual for CPC10PN-Tx. bus controller CPC10PN-T1 CPC 10PN -T1 COM-1 CPC10PN-T4 COM-2 COM-3 COM-4 X51 X52 X53 X54 X61 X82 X81 X51/COM-1 NS MS CM CE DC 24 V X41PWR X61 X82 X81 NS MS CM CE DC 24 V X41PWR bus controller CPC10PN-T4 + +0 V 0 V+ + 0 V 0 V CPC 10PN -T1 X61X 82 X81X 51/COM-1 NS MS CM CE DC 24 V X41PWR 114,522,6 DIN rail EN 60715-35x7,5 (not included) Provide space for connectors and cables + +0 V 0 V 114,5 114,545,2 DIN rail EN 60715-35x7,5 (not included) Provide space for connectors and cables COM-1 CPC10PN-T4 COM-2 COM-3 COM-4 X51 X52 X53 X54 X61X 82 X81 NS MS CM CE DC 24 V X41PWR + + 0 V 0 V CPC10PN-T1-xxx with SVS201-PWR-08-xxx fitted with ESX50D-S100