CPC10IO-S1-001 E-T-A | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 2

Technical content

Features

l Integral DC24 V power distribution system for power distribution and overcurrent protection l Complete diagnosis and parameterising of the entire power distribution system l For electronic circuit protectors ESX50D-S100 / -S110 l Variable configuration of the connection with up to 16 electronic circuit protectors l Fully-fledged communication interface IO link via a port of the IO link master l Service and maintenance interface via IO link connection l Profitability through considerably reduced wiring time l Reduction of planning, design and installation time l Ease of maintenance, diagnosis and system extension CPC10IO Technical data (Tamb = 25 °C, UB = DC 24 V) Suitable for the following types: Power distribution boards Electronic circuit protector Electronic circuit protector SVS201-PWR-xx ESX50D-S100 (completely parameterisable by means of the CPC10IO) ESX50D-S110 (current rating adjustable by means of the rotary switch on the circuit protec- tor, otherwise completely parameteris- able via the CPC10IO) Application Intelligent DC 24 V Power Distribution System Supply feed (1/11) Voltage ratings DC 24 V (18 ... 32 V) Current ratings typically 15 mA Terminals IO link connection Mounting method plug-in mounting on SVS201-PWR-xx IO link connection with the IO link master (X81) X81 COM connection with the IO link master via inlet plug the electrical specification has to meet the requirements of the “IO Link Community” connector 1: IO link L+ DC +24 V connector 2: IO link C/Q connector 3: IO link L- power supply must also be possible via X81 COM Terminals connectors, 3-pin (plugged on) cable cross section flexible with wire end ferrule (without plastic sleeve) 0.25 – 0.5 mm² stripping length 6 mm Status indication of the CPC10PN-Tx LED "PWR" LED lighted with supply voltage applied. LED indication unicolour green LED “CE/CM“ display shows the status of the communication unit LED status indication options: red, green, yellow, orange Control input is via the processor of the CPC10IO. Operating mode Indication of operating mode LED CE/CM LED PWR SVS_SYSTEMINIT yellow green SVS_ERROR_CRITICAL red green SVS_ERROR_UNCRITICAL flashing red green SVS_PARAMETERIZATION green SVS_STANDALONE blinking green green SVS_NORMAL_MODE green green Order numbering code Type CPC10 Bus terminal controller for ControlPlex® Board for SVS201-PWR-xx with ESX50D-S100 / -S110 l integral DC 24 V power distribution system l for max. 16 psc electronic circuit protectors type ESX50D-S xxx l communication-capable Version: Bus system IO IO link terminal: 3-pin connection sleeve Version - number of power distribution boards to be connected S1 pluggable, 1 port Product versions 001 marking version CPC10 IO - S1 - 001 ordering example

www.e-t-a.de IO link Controller CPC10IO (ControlPlex®) 1651 Notes Terminal arrangement CPC10IO-S1-xxx Dimensions CPC10PN-T1-xxx Application example of IO link application Conformity and approvals Markings l The CPC10IO-S1 -001 is only intended for use with safety extra- low voltage (=24 V DC). l Connection to a higher or not reliably disconnected voltage can cause hazardous conditions or damages l Only the intended power distribution boards must be used. l The technical data of the used circuit protectors have to be observed l The entire power distribution system must only be installed by qualified personnel l Only after expert installation must the device be supplied with power l After tripping of the circuit protector and before reset, the cause of the failure (short circuit or overload) must be remedied l The national standards (e.g. for Germany DIN VDE 0100) have to be observed for installation and selection of feed and return cables. l 0 V ptential load and control voltage connected l For convenient adjustment and configuration by means of projecting software a master data file (GSDML file) will be made available for downloading on the E-T-A homepage Please observe the separate user manual for CPC10IO-S1-001. l CE l PNO certification (IO-Link Manufacturer Declaration) CE Declaration of Conformity with the presently valid EMC Directive CAUTION Caution: Electrostatically sensitive sub-assemblies can be destroyed by voltages far below the human perception threshold. These voltages already occur if you touch a component or electrical terminals of a sub- assembly without being electrostatically discharged. The damage of a sub- assembly caused by an overvoltage is often not immediately recognised, but will be noticed only after a longer operating time. Technical data (Tamb = 25 °C, UB = DC 24 V) General data Mounting method plug-in mounting on SVS201-PWR-xx Temperature range 0...+50 °C (without condensation) Storage temperature -20 ... +70 °C Housing material moulded Degree of protection terminals IP20 EN60529 Dielectric strength DC 32 V (load circuit) Dimensions see dimensional drawing (tolerances to DIN ISO 286 part 1 IT13) Mass CPC10IO-S1-001 approx. 40g EMC l EN 61000-6-2: 2005 Electromagnetic compatibility (EMC) part 6-2: Basic standards – noise immunity for industrial areas l EN 61000-6-4: 2007+A1:2011 Electromagnetic compatibility (EMC) - part 6-4: Basic standards – noise immunity for industrial areas Vibration resistance 3 g, test to IEC 60068-2-6 test Fc

1 LINE+

-S1-001 C/Q

11 GND

3 COM

Anschluss 1 (L+) Anschluss 2 (C/Q) Anschluss 3 (L-) LED PWR EM -S1-001 C/Q Aufstecksperre LED grünLED Flachstecker EN 60934-6,3-0,8 Stecker Platz für Kabel vorsehen 7010,3 ca. 7 6x6,8 =40,8 6,8 12,3 CPC10IO-S1-001 with SVS201-PWR- 08-xxx fitted with 5x ESX50D-S100 and 2x ESX50D-S110