Subject to change without notice. www.cree.com/ledlamps Data Sheet: CLD-CT1143.000 Cree® P4 LED CP41B-RDS/ADS (40 degrees) CP41B-RFS/AFS (70 degrees) CP41B-RHS/AHS (100 degrees) Data Sheet This revolutionary package design allows the lighting designer to reduce the number of LEDs required and provide a more uniform and unique illuminated appearance than with other LED solutions. This is possible through the efficient optical package design and high-current capabilities. The low-profile package can be easily coupled with reflectors or lenses to efficiently distribute light and provide the desired lit appearance. This product family employs red and amber LED materials, which allows designers to match the color of many lighting applications like vehicle signal lamps, channel letters and gaming-equipment lighting.

FEATURES

  • Size (mm): 7.6 x 7.6
  • Color and Typical Dominant Wavelength (nm): » Red (628) » Amber (591)
  • Luminous Flux (mlm) » CP41B-RDS (4400 - 11000) » CP41B-RFS (4400 - 11000) » CP41B-RHS (4400 - 13200) » CP41B-ADS (4400 - 11000) » CP41B-AFS (5500 - 13200) » CP41B-AHS (5500 - 13200)
  • Lead-Free
  • RoHS Compliant

APPLICATIONS

  • Channel Letter
  • Amusement

2 CLD-CT1143.000 Cree, Inc.

4600 Silicon Drive

Durham, NC 27703 USA Tel: +1.919.313.5300 Fax: +1.919.313.5778 www.cree.com/ledlamps Copyright © 2009 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree and the Cree logo are registered trademarks of Cree, Inc. Absolute Maximum Ratings (TA = 25°C) Items Symbol Absolute Maximum Rating Unit Red/Amber Forward Current IF 70 Note1 mA Peak Forward Current Note2 IFP 200 mA Reverse Voltage VR 5 V Power Dissipation PD 220 mW Operation Temperature Topr -40 ~ +100 °C Storage Temperature Tstg -40 ~ +100 °C Lead Soldering Temperature Tsol Max. 260°C for 5 sec. max. (3 mm from the base of the epoxy bulb) Note: 1. A heat sink is recommended if the device is operated at ambient temperatures higher than 25°C. 2. Pulse width ≤0.1 msec, duty ≤1/10. Typical Electrical & Optical Characteristics (TA = 25°C) Characteristics Color Symbol Condition Unit Minimum Typical Maximum Forward Voltage Red/Amber VF IF = 70 mA V 2.5 3.0 Reverse Current Red/Amber IR VR = 5 V μA 100 Dominant Wavelength Red λD IF = 70 mA nm 620 628 637 Amber λD IF = 70 mA nm 584 591 599 Luminous Flux Red CP41B-RDS (40 degree) Φv IF = 70 mA mlm 4400 7000 CP41B-RFS (70 degree) Φv IF = 70 mA mlm 4400 7500 CP41B-RHS (100 degree) Φv IF = 70 mA mlm 5500 8000 Amber CP41B-ADS (40 degree) Φv IF = 70 mA mlm 4400 6500 CP41B-AFS (70 degree) Φv IF = 70 mA mlm 5500 7500 CP41B-AHS (100 degree) Φv IF = 70 mA mlm 5500 8000 50% Power Angle CP41B-RDS/ADS 2θ½ IF = 70 mA deg 40 CP41B-RFS/AFS 2θ½ IF = 70 mA deg 70 CP41B-RHS/AHS 2θ½ IF = 70 mA deg 100

3 CLD-CT1143.000 Cree, Inc. Durham, NC 27703 USA Tel: +1.919.313.5300 Fax: +1.919.313.5778 www.cree.com/ledlamps Copyright © 2009 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree and the Cree logo are registered trademarks of Cree, Inc. Flux Bin Limit (IF = 70 mA) Tolerance of measurement of luminous Flux is ±15% Color Bin Limit (IF = 70 mA) VF Bin Limit (IF = 70 mA) Tolerance of measurement of dominant wavelength is ±1 nm Red Bin Code Min. (V) Max. (V) 23 2.0 2.2 24 2.2 2.4 25 2.4 2.6 26 2.6 2.8 27 2.8 3.0 Amber Bin Code Min. (V) Max. (V) 23 2.0 2.2 24 2.2 2.4 25 2.4 2.6 26 2.6 2.8 27 2.8 3.0 Tolerance of measurement of VF is ± 0.05 V Amber Bin Code Min. (nm) Max. (nm) A2 584 587 A3 587 590 A4 590 593 A5 593 596 A6 596 599 Red Bin Code Min. (nm) Max. (nm) RE 620 637 Red Amber CP41B-RDS/RFS (40/70 degree) Bin Code Min. (mlm) Max. (mlm) L0 4400 5500 M0 5500 6600 N0 6600 8730 P0 8730 11000 CP41B-RHS (100 degree) Bin Code Min. (mlm) Max. (mlm) L0 4400 5500 M0 5500 6600 N0 6600 8730 P0 8730 11000 Q0 11000 13200 CP41B-ADS (40 degree) Bin Code Min. (mlm) Max. (mlm) L0 4400 5500 M0 5500 6600 N0 6600 8730 P0 8730 11000 CP41B-AFS/AHS (70/100 degree) Bin Code Min. (mlm) Max. (mlm) M0 5500 6600 N0 6600 8730 P0 8730 11000 Q0 11000 13200

4 CLD-CT1143.000 Cree, Inc. Durham, NC 27703 USA Tel: +1.919.313.5300 Fax: +1.919.313.5778 www.cree.com/ledlamps Copyright © 2009 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree and the Cree logo are registered trademarks of Cree, Inc. Order Code Table* Color Kit Number Viewing Angle Luminous Flux (mlm) Dominant Wavelength Min. Max. Color Bin Min. (nm) Color Bin Max. (nm) Red CP41B-RDS-CL0P0EE4 40 4400 11000 RE 620 RE 637 Red CP41B-RDS-CM0P0EE4 40 5500 11000 RE 620 RE 637 Color Kit Number Viewing Angle Luminous Flux (mlm) Dominant Wavelength Min. Max. Color Bin Min. (nm) Color Bin Max. (nm) Red CP41B-RFS-CL0P0EE4 70 4400 11000 RE 620 RE 637 Red CP41B-RFS-CM0P0EE4 70 5500 11000 RE 620 RE 637 Red CP41B-RFS-CN0P0EE4 70 6600 11000 RE 620 RE 637 Color Kit Number Viewing Angle Luminous Flux (mlm) Dominant Wavelength Min. Max. Color Bin Min. (nm) Color Bin Max. (nm) Red CP41B-RHS-CL0Q0EE4 100 4400 13200 RE 620 RE 637 Red CP41B-RHS-CM0Q0EE4 100 5500 13200 RE 620 RE 637 Red CP41B-RHS-CN0Q0EE4 100 6600 13200 RE 620 RE 637

5 CLD-CT1143.000 Cree, Inc. Durham, NC 27703 USA Tel: +1.919.313.5300 Fax: +1.919.313.5778 www.cree.com/ledlamps Copyright © 2009 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree and the Cree logo are registered trademarks of Cree, Inc. Order Code Table* Color Kit Number Viewing Angle Luminous Flux (mlm) Dominant Wavelength Min. Max. Color Bin Min. (nm) Color Bin Max. (nm) Amber CP41B-ADS-CL0P0264 40 4400 11000 A2 584 A6 599 Amber CP41B-ADS-CM0P0354 40 5500 11000 A3 587 A5 596 Amber CP41B-ADS-CM0P0454 40 5500 11000 A4 590 A5 596 Color Kit Number Viewing Angle Luminous Flux (mlm) Dominant Wavelength Min. Max. Color Bin Min. (nm) Color Bin Max. (nm) Amber CP41B-AFS-CM0Q0264 70 5500 13200 A2 584 A6 599 Amber CP41B-AFS-CN0Q0354 70 6600 13200 A3 587 A5 596 Amber CP41B-AFS-CN0Q0454 70 6600 13200 A4 590 A5 596 Color Kit Number Viewing Angle Luminous Flux (mlm) Dominant Wavelength Min. Max. Color Bin Min. (nm) Color Bin Max. (nm) Amber CP41B-AHS-CM0Q0264 100 5500 13200 A2 584 A6 599 Amber CP41B-AHS-CN0Q0354 100 6600 13200 A3 587 A5 596 Amber CP41B-AHS-CN0Q0454 100 6600 13200 A4 590 A5 596 Note: The above kit numbers represent order codes that include multiple intensity-bin and color-bin codes. Only one intensity-bin code and one color-bin code will be shipped on each reel. Single intensity-bin codes and single color-bin codes will not be orderable.

6 CLD-CT1143.000 Cree, Inc. Durham, NC 27703 USA Tel: +1.919.313.5300 Fax: +1.919.313.5778 www.cree.com/ledlamps Copyright © 2009 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree and the Cree logo are registered trademarks of Cree, Inc. Graphs FIG.2 RELATIVE LUMINOUS INTENSITY VS. IF(mA) FORWARD CURRENT IF(mA)VF(V) FORWARD VOLTAGE. FIG.1 FORWARD CURRENT VS. IF (mA) 0.0 0.25 1.0 0.5 0.75 1.25 6020 40 100800 100 4020 8060 1000 Ta( C) Red Amber FIG.5 Red & Amber MAXIMUM FORWARD DCCURRENT VS AMBIENT TEMPERATURE (Tjmax=120 C) VS. REVERSE VOLTAGE. FIG.3 Red & Amber REVERSE CURRENT FIG.6 FAR FIELD PATTERN -90 -60 -30 0 0.5 1.0 FIG.4 RELATIVE LUMINOUS INTENSITY VS. WAVELENGTH. 30 60 90 50% Power Angle : 40 20.0 40.0 80.0 60.0 100.0 0.0 Red Amber IV(%) Angle IV(%) -10-50 Vr(V) -30-40 -20 -40 Ir(uA) -50 -30 -20 -10 -60 (RELATIVE LUMINOUS INTENSITY) WL(nm) 80% 20% 40% 60% 100% 700300 500400 600 800 900 RedAmber CP41B-RDS/ADS

7 CLD-CT1143.000 Cree, Inc. Durham, NC 27703 USA Tel: +1.919.313.5300 Fax: +1.919.313.5778 www.cree.com/ledlamps Copyright © 2009 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree and the Cree logo are registered trademarks of Cree, Inc. FIG.7 FAR FIELD PATTERN -90 -60 -30 0 0.5 1.0 30 60 90 50% Power Angle : 70 IV(%) Angle FIG.8 FAR FIELD PATTERN -90 -60 -30 0 0.5 1.0 30 60 90 50% Power Angle : 100 IV(%) Angle CP41B-RHS/AHS CP41B-RFS FIG.9 FAR FIELD PATTERN -90 -60 -30 0 0.5 1.0 30 60 90 50% Power Angle : 100 IV(%) Angle CP41B-AFS Graphs

8 CLD-CT1143.000 Cree, Inc. Durham, NC 27703 USA Tel: +1.919.313.5300 Fax: +1.919.313.5778 www.cree.com/ledlamps Copyright © 2009 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree and the Cree logo are registered trademarks of Cree, Inc. Mechanical Dimensions All dimensions are in mm. Tolerance is ±0.25 mm unless otherwise noted. An epoxy meniscus may extend about 1.5 mm down the leads. Burr around bottom of epoxy may be 0.5 mm max. Notes RoHS Compliance The levels of environmentally sensitive, persistent biologically toxic (PBT), persistent organic pollutants (POP), or otherwise restricted materials in this product are below the maximum concentration values (also referred to as the threshold limits) permitted for such substances, or are used in an exempted application, in accordance with EU Direc- tive 2002/95/EC on the restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS), as amended through April 21, 2006. Vision Advisory Claim Users should be cautioned not to stare at the light of this LED product. The bright light can damage the eye. 2/4 Format #: COTCO-D-074 REV.3 Document No. SPE/LP377UHR1-70G-01-MT Rev. No. 00 AApppplliiccaattiioonnss:: DDiimmeennssiioonn DDrraawwiinngg - Advertising Signs - Indicators - Traffic - Automotive Lighting AAbbssoolluuttee MMaaxxiimmuumm RRaattiinnggss aatt TTaa == 2255°C Items Symbol Absolute maximum Rating Unit Forward Current*2 IF 70 mA Peak Forward Current*1 IFP 200 mA Reverse Voltage VR 5 V Power Dissipation PD 210 mW Operation Temperature Topr -40 ~ +100 °C Storage Temperature Tstg -40 ~ +100 °C Lead Soldering Temperature Tsol Max.260°C for 5 sec Max. (3mm from the base of the epoxy bulb) Electrostatic Discharge Classification (MIL-STD-883E) ESD Class II *1 pulse width <=0.1msec duty <=1/10 *2 Heat sink is recommended to be adequated if the device is operated at ambient temperatures higher than 25 deg C. For long term performance the drive currents between 10mA and 50mA are recommended. Please contact COTCO sales representative for more information on recommended drive conditions. TTyyppiiccaall EElleeccttrriiccaall && OOppttiiccaall CChhaarraacctteerriissttiiccss (( TTaa == 2255°C)) Items Symbol Condition Min. Typ. Max. Unit Forward Voltage VF IF = 70mA --- 2.5 3.0 V Reverse Current IR VR = 5V --- --- 100 µA Dominant Wavelength λD IF = 70mA 618 624 630 nm Luminous Flux ΦV IF = 70mA 4400 7500 --- mlm 50% Power Angle 2θ½ IF = 70mA --- 70 --- deg CP41B-RHS/AHS: CP41B-RDS/RFS/ADS/AFS:

9 CLD-CT1143.000 Cree, Inc. Durham, NC 27703 USA Tel: +1.919.313.5300 Fax: +1.919.313.5778 www.cree.com/ledlamps Copyright © 2009 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree and the Cree logo are registered trademarks of Cree, Inc. Kit Number System Cree LED lamps are tested and sorted into performance bins. A bin is specified by ranges of color, forward voltage, and brightness. Sorted LEDs are packaged for shipping in various convenient options. Please refer to the “Cree LED Lamp Packaging Standard” document for more information about shipping and packaging options. Cree LEDs are sold by order codes in combinations of bins called kits. Order codes are configured in the following manner:

10 CLD-CT1143.000 Cree, Inc. Durham, NC 27703 USA Tel: +1.919.313.5300 Fax: +1.919.313.5778 www.cree.com/ledlamps Copyright © 2009 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree and the Cree logo are registered trademarks of Cree, Inc. Package Features:

  • The LEDs are packed in cardboard boxes after packaging in normal or anti-electrostatic bags.
  • Cardboard boxes will be used to protect the LEDs from mechanical shock during transportation.
  • The boxes are not water-resistant, and they must be kept away from water and moisture.
  • The Tube Pack type of packaging.
  • Max 60 pcs per tube. Hu e XX AX XXX XXX XXX X COL OR LED LAMP J OWAXXXXX -XX -XXX LXXXXXXXX-XXX LOT TYPE xxx xxx V f XX Iv XRANK QT Y P CS R R