Features
- 5 mm Mini SIP SSR
- Ratings 24 VDC @ 3.5 A, 48 VDC @ 100mA, 100 VDC @ 6 A and
240 VAC @ 2 A
- DC Control, 5, 24 and 60 V
- UL & cUL recognized @ 40°C, 100K-Cycle Endurance Test
- CE & RoHS Compliant
Applications
- Automation Equipment
- Test Equipment
- Packaging equipment
- Valves & Solenoids
- Vending Equipment
- Medical Equipment PRODUCT SELECTION SPECIFICATIONS Control Voltage 3.5 A 100mA 6 A 2 A 3-12 VDC CN024D05 CN048D05 CN100D05 CN240A05 15-30 VDC CN024D24 CN048D24 CN100D24 CN240A24 38-72 VDC CN024D60 CN048D60 CN240A60 Sensata | Crydom CN Series AC & DC Output Plug-in Solid State Relays are thin 5 mm wide relays ideally suited for high density PCB applications. CN Series SSRs are designed to be pluggable into industry standard relay sockets or solderable into printed circuit boards, and they are available in ratings of 2 Amps at 24 to 280 VAC or 0.1 to 6 Amps at 0 to 100 VDC. They are UL recognized and CE compliant. Output(1)
www.sensata.com Page 2 Copyright © 2021 Sensata Technologies, Inc. Description CN024D05 CN024D24 CN024D60 Control Voltage Range 3-12 VDC 15-30 VDC 38-72 VDC Must Turn On Voltage 3 VDC 15 VDC 38 VDC Must Turn Off Voltage 1 VDC 5 VDC 5 VDC Nominal Input Impedance 500 Ohm 3.5K Ohm 20K Ohm Typical Input Current 10mA @ 5 VDC 7mA @ 24 VDC 3mA @ 60 VDC Typical Turn-On Time [μsec] 120 350 400 Typical Turn-Off Time [μsec] 100 80 70 Description CN048D05 CN048D24 CN048D60 Control Voltage Range 3-12 VDC 15-30 VDC 38-72 VDC Must Turn On Voltage 3 VDC 15 VDC 38 VDC Must Turn Off Voltage 1 VDC 5 VDC 5 VDC Nominal Input Impedance 1.25K Ohm 3K Ohm 20K Ohm Typical Input Current 12mA @ 5 VDC 8mA @ 24 VDC 3mA @ 60 VDC Typical Turn-On Time [μsec] 20 20 20 Typical Turn-Off Time [μsec] 130 130 130 Description CN100D05 CN100D24 Control Voltage Range 3-12 VDC 15-30 VDC Must Turn On Voltage 3 VDC 15 VDC Must Turn Off Voltage 1 VDC 5 VDC Nominal Input Impedance 420 Ohm 3K Ohm Typical Input Current 12mA @ 5 VDC 8mA @ 24 VDC Maximum Turn-On Time [μsec] 400 800 Maximum Turn-Off Time [μsec] 180 180 Description CN240A05 CN240A24 CN240A60 Control Voltage Range 3-12 VDC 15-30 VDC 38-72 VDC Must Turn On Voltage 3 VDC 15 VDC 38 VDC Must Turn Off Voltage 1 VDC 5 VDC 5 VDC Nominal Input Impedance 240 Ohm 3.5K Ohm 20K Ohm Typical Input Current 15mA @ 5 VDC 6mA @ 24 VDC 4mA @ 60 VDC Typical Turn-On Time [μsec] (4) 1/2 Cycle 1/2 Cycle 1/2 Cycle Typical Turn-Off Time [μsec] 1/2 Cycle 1/2 Cycle 1/2 Cycle Input Specifications for CN024 (1) Input Specifications for CN048 (1) Input Specifications for CN100 (1) Input Specifications for CN240 (1) Maximum PWM (Hz) (3) 500 500 40 N.A. Minimum Off-State dv/dt @ Maximum Rated Voltage [V/μsec] N/A N/A N/A 500
www.sensata.com Page 3 Copyright © 2021 Sensata Technologies, Inc. Description Parameters Dielectric Strength, Input/Output/Base (50/60Hz) (5) 2.5KV Maximum Capacitance, Input/Output 1.5 pF Ambient Operating Temperature Range -20 to 80°C Ambient Storage Temperature Range -20 to 100°C Weight (typical) 0.14 oz. (4.05g) Housing Material UL 94 V0 Overvoltage Category lll Pollution Degree 2 Degree of protection (Encapsulation) IP67 GENERAL SPECIFICATIONS (1) THERMAL DERATE INFORMATION Ambient Temperature (ºC) Load Current (Amps) 3.5 2.5 1.5 20 4030 50 70 8060 0.5 Load Current (Amps) Ambient Temperature (ºC) 1.5 20 4030 50 70 8060 0.5 Ambient Temperature (ºC) Load Current (Amps) 0.1 0.08 0.06 0.04 20 30 6040 50 70 80 0.02 CN024Dxx CN048Dxx CN240Axx CN100Dxx 20 30 40 50 60 70 80 Load Current (Amps) Ambient Temperature (ºC)
www.sensata.com Page 4 Copyright © 2021 Sensata Technologies, Inc. WIRING DIAGRAM
Copyright © 2021 Sensata Technologies, Inc.
4411 A1+ A2-
Relays on a standard 35 mm DIN rail. Please read all installation instructions before using the sockets and relays.
- Match CN Series SSR to appropriate DRSCN socket part number to create an assembly (See Relay/Socket Compatibility)
- Insert the CN SSR on the socket
- Mount the socket on the DIN rail
- Wire the socket to the control side. AWG #24-14 solid, AWG #24-14 stranded (0.2-2.1 mm2)
- Wire the socket to the load side. AWG #24-14 solid, AWG #24-14 stranded (0.2-2.1 mm2)
- Maximum torque: 5-7 lb-in (0.56-0.8 Nm)
- If multiple units are installed be sure to follow derating curves for assemblies
TABLE 1. Relay/Socket Compatibility
www.sensata.com Page 6 Copyright © 2021 Sensata Technologies, Inc.
- Installing a CN Series solid state relay in a socket that does not have matching input/output specifications may result in damage to either the relay, socket, or both, and/or in non-operation.
- Maximum output rating for DRSCN Series sockets is 250 V, 6 Amps regardless of chosen SSR.
- Proper polarity must be observed for DC input control voltage sockets being terminal A1+ positive with respect to terminal A2-.
- For AC loads, the AC line can be wired to either DRS socket terminal 11 or terminal 14. The AC load may also be wired on either the line or neutral side of the SSR. For DC loads, the proper polarity must be observed for the power supply, load and DRS socket with terminal 13 being positive with respect to terminal 14.
- DC inductive loads must be diode suppressed.
- All terminals feature screw M3 slotted drive. WIRING DIAGRAMS Mounting on a Printed Circuit Board When different kinds of packages are mounted on PC board, temperature rise at soldering lead is dependent on package size. Therefore, set the lower temperature soldering condition than the conditions of item “Soldering profile”, and confirm the temperature condition of actual usage before soldering. When soldering condition exceeds our recommendation, the SSR characteristics may be adversely affected. It may occur package crack or power electronics failures because of thermal expansion unconformity and resin strength reduction. Solder creepage, wettability, or soldering strength will be affected by the soldering condition or used soldering type. Soldering Profile The classification temperature (Tc) of this product is 245ºC (473ºF) and the maximum dwell time (Tp) is 30 seconds, the body temperature of this device may be (Tc - 5)ºC or greater. The classification temperature sets the Maximum Body Temperature allowed for this device during lead-free reflow processes, maximum 1 cycle for reflow is allowed. For any other processes, the guidelines of J-STD-020 must be observed. Manual soldering method Temperature: 350ºC (662ºF) to 400°C (752ºF), within 3s, electrical power 30 to 60W Tolerances: ±0.02 in / 0.5 mm All dimensions are in: inches [millimeters] DRSCN30 Load Load A B SupplyControl DRSCN05, DRSCN24 Load Load A B SupplyControl Recommended PCB hole layout:
www.sensata.com Page 7 Copyright © 2021 Sensata Technologies, Inc. ORDERING OPTIONS Example : CN240A24R CN 240A 24 R Series CN Operating Voltage 240A: 240 VAC, 2 A 024D: 24 VDC, 3.5 A 048D: 48 VDC, 0.1 A 100D: 100 VDC, 6 A Control Voltage 05: 3-12 VDC 24: 15-30 VDC 60: 38-72 VDC Switching Mode (AC Output only) Blank: Zero Voltage Turn-On R: Random Turn-On Required for valid part number For options only and not required for valid part number ACCESSORIES DRSCN Series DIN Rail Mountable Sockets DRSCN05, DRSCN24, DRSCN30
- Sockets are fully compatible with CN series SSRs
- 6.2 mm wide
- LED status indicator
- Socket clip fits all standard 35 mm
- DIN rail profiles
- UL & cUL recognized, CE & RoHS compliant RELAY/SOCKET COMPATIBILITY G, H SSR PN DR Socket PN Socket Input Voltage CN024D05 CN048D05 CN100D05 CN240A05 DRSCN05 3-12 VDC CN024D24 CN048D24 CN100D24 CN240A24 DRSCN24 15-30 VDC CN024D05 CN024D24 CN048D05 CN048D24 CN100D05 CN100D24 CN240A05 CN240A24 DRSCN30 4-30 VDC G Installing a CN Series solid state relay in a socket that does not have matching input/output specifications may result in non-operation or damage to either the relay, socket or both. H Maximum output rating for DRSCN Series sockets is 250 V / 6 Amps regardless of chosen SSR.
www.sensata.com Page 8 Copyright © 2021 Sensata Technologies, Inc. ID Marker Strips CNLB, CNLN, CNL2 Black Strips Part no.: CNLB Numbered 1 to 10 Strips Part no.: CNLN Numbered 11 to 20 Strips Part no.: CNL2 A package of 10 plastic strips comprising 10 individual unprinted markers which can be placed on sockets’ terminal block for easy identification during the use of multiple units. A package of 10 plastic strips comprising 10 markers printed individually from 1 to 10 which can be placed on sockets’ terminal block for easy identification during the use of multiple units. A package of 10 plastic strips comprising 10 markers printed individually from 11 to 20 which can be placed on sockets’ terminal block for easy identification during the use of multiple units. AGENCY APPROVALS & CERTIFICATIONS Designed in accordance with the requirements of IEC 62314 E116950 (Except CN100Dxx) GENERAL NOTES (1) All parameters at 25°C unless otherwise specified. (2) See derating curves (3) Operating above the specified frequency will damage the SSR (DC output only). (4) Turn-on time for random turn-on version is 0.1 ms. (5) 3.75KV for CN048Dxx
www.sensata.com CONTACT US Americas +1 (877) 502 5500 sales.crydom@sensata.com Europe, Middle East & Africa +44 (1202) 416170 ssr-info.eu@sensata.com Asia Pacific sales.isasia@list.sensata.com China +86 (21) 2306 1500 Japan +81 (45) 277 7117 Korea +82 (31) 601 2004 India +91 (80) 67920890 Rest of Asia +886 (2) 27602006 ext 2808 Copyright © 2021 Sensata Technologies, Inc. Sensata Technologies, Inc. (“Sensata”) data sheets are solely intended to assist designers (“Buyers”) who are developing systems that incorporate Sensata products (also referred to herein as “components”). Buyer understands and agrees that Buyer remains responsible for using its independent analysis, evaluation and judgment in designing Buyer’s systems and products. Sensata data sheets have been created using standard laboratory conditions and engineering practices. Sensata has not conducted any testing other than that specifically described in the published documentation for a particular data sheet. Sensata may make corrections, enhancements, improvements and other changes to its data sheets or components without notice. Buyers are authorized to use Sensata data sheets with the Sensata component(s) identified in each particular data sheet. HOWEVER, NO OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE TO ANY OTHER SENSATA INTELLECTUAL PROPERTY RIGHT, AND NO LICENSE TO ANY THIRD PARTY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT, IS GRANTED HEREIN. SENSATA DATA SHEETS ARE PROVIDED “AS IS”. SENSATA MAKES NO WARRANTIES OR REPRESENTATIONS WITH REGARD TO THE DATA SHEETS OR USE OF THE DATA SHEETS, EXPRESS, IMPLIED OR STATUTORY , INCLUDING ACCURACY OR COMPLETENESS. SENSATA DISCLAIMS ANY WARRANTY OF TITLE AND ANY IMPLIED WARRANTIES OF MERCHANTABILITY , FITNESS FOR A PARTICULAR PURPOSE, QUIET ENJOYMENT, QUIET POSSESSION, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL PROPERTY RIGHTS WITH REGARD TO SENSATA DATA SHEETS OR USE THEREOF. All products are sold subject to Sensata’s terms and conditions of sale supplied at www.sensata.com SENSATA ASSUMES NO LIABILITY FOR APPLICATIONS ASSISTANCE OR THE DESIGN OF BUYERS’ PRODUCTS. BUYER ACKNOWLEDGES AND AGREES THAT IT IS SOLELY RESPONSIBLE FOR COMPLIANCE WITH ALL LEGAL, REGULATORY AND SAFETY-RELATED REQUIREMENTS CONCERNING ITS PRODUCTS, AND ANY USE OF SENSATA COMPONENTS IN ITS APPLICATIONS, NOTWITHSTANDING ANY APPLICATIONS-RELATED INFORMATION OR SUPPORT THAT MAY BE PROVIDED BY SENSATA. Mailing Address: Sensata Technologies, Inc., 529 Pleasant Street, Attleboro, MA 02703, USA. Rev. 06/03/2021 ECN 21137 FDE-07-01 Rev. B WARNINGS RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE
- The product’s side panels may be hot, allow the product to cool before touching
- Follow proper mounting instructions including torque values
- Do not allow liquids or foreign objects to enter this product Failure to follow these instructions can result in serious injury, or equipment damage. HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH
- Disconnect all power before installing or working with this equipment
- Verify all connections and replace all covers before turning on power Failure to follow these instructions will result in death or serious injury.