  • 5mm Mini SIP SSR
  • Ratings 24 VDC @ 3.5 A, 48 VDC @ 100mA and 240 VAC @ 2 A
  • DC Control, 5, 24 and 60 V
  • UL & cUL recognized @ 40°C, 100K-Cycle Endurance Test
  • CE & RoHS Compliant PRODUCT SELECTION Control Voltage 3.5 A 100mA 2 A 3-12 VDC CN024D05 CN048D05 CN240A05 15-30 VDC CN024D24 CN048D24 CN240A24 38-72 VDC CN024D60 CN048D60 CN240A60 AVAILABLE OPTIONS Required for valid part number For options only and not required for valid part number Series Control Voltage 05: 3-12 VDC 24: 15-30 VDC 60: 38-72 VDC Switching Mode Blank: Zero Voltage Turn-On R: Random Turn-On Operating Voltage 240A: 240 VAC, 2 A 024D: 24 VDC, 3.5 A 048D: 48 VDC, 0.1 A

24 RCN 240A

OUTPUT SPECIFICATIONS (1)

Description

Maximum Load Current @ 40°C (2) Minimum Load Current [mA] Maximum Blocking Voltage Maximum Surge Current [Apk] Maximum I²t for fusing 50/60Hz (1/2 cycle) [A² sec] Typical On-State Voltage Drop @ Rated Current (V) Maximum Off-State Leakage Current @ Rated Voltage [mA] Maximum PWM (Hz) (4) Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] (5) 0-48 VDC 100mA (3)

60 VDC

0.3 mA (10ms) N.A. 1.0 0.001 500 N/A CN048Dxx N.O. 2 A 24-280 VAC (47-63Hz)

600 VDC

115/120 (50/60 Hz, 1 cycle) 1.1 (peak) 4.0 N.A. 500 CN240Axx N.O. 3.5 A 0-24 VDC

30 VDC

9 (10ms) N.A. 0.4 0.001 500 N/A CN024Dxx N.O.Switch Configuration Do not forget to visit us at: www.crydom.com Copyright © 2017 Crydom Inc. Specifications subject to change without notice.

Do not forget to visit us at: www.crydom.com Copyright © 2017 Crydom Inc. Specifications subject to change without notice. INPUT SPECIFICATIONS FOR CN024 (1) (6) CN024D24 15-30 VDC

15 VDC

5 VDC

3.5K Ohm 7mA @ 24 VDC 350 CN024D05 3.0-12 VDC

3.0 VDC

1.0 VDC

500 Ohm

10mA @ 5 VDC 120 100 CN024D60 38-72 VDC

38 VDC

3mA @ 60 VDC 400 CN048D24

16 VDC

3.5K Ohm 5mA @ 24 VDC 130 CN048D05 3.0-12 VDC 1.25K Ohm 4mA @ 5 VDC 130 CN048D60 3mA @ 60 VDC 130 INPUT SPECIFICATIONS FOR CN048 (1) INPUT SPECIFICATIONS FOR CN240 (1) (1) All parameters at 25°C unless otherwise specified. (2) Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 (3) Turn-On time for random turn-on versions is 0.01 msec (DC control Models). (4) Operating frequency above 500Hz will damage the SSR (DC output only). (5) Off-state dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 (6) Turn-on time for random turn-on version is 0.1msec. (7) 3.75KV for CN048Dxx CN240A24 15-30 VDC 3.5K Ohm

5 VDC (6)

6mA @ 24 VDC 1/2 Cycle 1/2 Cycle CN240A05 3.0-12 VDC

240 Ohm

15mA @ 5 VDC 1/2 Cycle 1/2 Cycle CN240A60 4mA @ 60 VDC 1/2 Cycle 1/2 Cycle GENERAL SPECIFICATIONS (1) Dielectric Strength, Input/Output (50/60Hz) (7) Maximum Capacitance, Input/Output Ambient Operating Temperature Range Ambient Storage Temperature Range Weight (typical) Housing Material Overvoltage Category Parameters 2.5KV 1.5 pF -20 to 80°C -20 to 100°C 0.14 oz. (4.05g) UL 94 V0 lll Polution Degree 2 Degree of protection (Encapsulation) IP67

Do not forget to visit us at: www.crydom.com Copyright © 2017 Crydom Inc. Specifications subject to change without notice. THERMAL DERATE INFORMATION MECHANICAL SPECIFICATIONS Ambient Temperature (ºC) DERATE CURVES: CN024D - 3.5 A DERATE CURVES: CN048D - 100mA Load Current (Amps) DERATE CURVES: CN024 A - 2 AMP Ambient Temperature (ºC) Load Current (Amps) Tolerances: ±0.02 in / 0.5 mm All dimensions are in: inches [millimeters] 3.5 2.5 1.5 20 4030 50 70 8060 0.5 Load Current (Amps) Ambient Temperature (ºC) 1.5 20 4030 50 70 8060 0.5 0.02 [0.4] 0.99 [25.2] 1.10 [28.0] 0.84 [21.4] 0.20 [5.0] 0.08 [1.9] 0.59 [15.0] 0.15 [3.8] (2PLACES) 0.020 ±.005 [0.50 ±.13] 0.040 ±.005 [1.00 ±.13] 0.20 [5.0] 0.15 [3.8] 0.06 [1.4] 13(+) (2PLACES)

4411 A1+ A2-

0.1 0.08 0.06 0.04 20 30 6040 50 70 80 0.02

Do not forget to visit us at: www.crydom.com Copyright © 2017 Crydom Inc. Specifications subject to change without notice. AGENCY APPROVALS ACCESSORIES Designed in accordance with the requirements of IEC 62314 E116950 Agency Approvals Sockets are fully compatible with CN series SSRs 6.2 mm wide LED status indicator Socket clip fits all standard 35 mm DIN rail profiles UL & cUL recognized, CE & RoHS compliant RELAY/SOCKET COMPATIBILITY Socket InputSSR PN Voltage CNLB, CNLN, CNL2DRSCN05, DRSCN24 DRSCN Series DIN Rail Mountable Sockets ID Marker Strips (G, H) DR Socket PN CN024D05 CN048D05 CN024D24 CN048D24 CN240A05 CN240A24 DRSCN05 3-12 VDC Blank Strips Part no.: CNLB A package of 10 plastic strips comprising 10 individual unprinted markers which can be placed on sockets’ terminal block for easy identification during the use of multiple units. Numbered 1 to 10 Strips Part no.: CNLN A package of 10 plastic strips comprising 10 markers printed individually from 1 to 10 which can be placed on sockets’ terminal block for easy identification during the use of multiple units. Numbered 11 to 20 Strips Part no.: CNL2 A package of 10 plastic strips comprising 10 markers printed individually from 11 to 20 which can be placed on sockets’ terminal block for easy identification during the use of multiple units.15-30 VDC Rev. 060116 DRSCN24 (G) (H) Installing a CN Series solid state relay in a socket that does not have matching input/output specifications may result in non-operation or damage to either the relay, socket or both. Maximum output rating for DRSCN Series sockets is 250 V / 6 Amps regardless of chosen SSR.

Do not forget to visit us at: www.crydom.com Copyright © 2017 Crydom Inc. Specifications subject to change without notice. WARNING / AVERTISSEMENT / WARNUNG /ADVERTENCIA / AVVERTENZA / 警告 RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE

  • The product's side panels may be hot, allow the product to cool before touching.
  • Follow proper mounting instructions including torque values.
  • Do not allow liquids or foreign objects to enter this product. Failure to follow these instructions can result in serious injury, or equipment damage. RISQUE DE DOMMAGE MATERIEL ET DE SURCHAUFFE DU BOITIER
  • Les panneaux latéraux du produit peuvent être chauds. Laisser le produit refroidir avant de le toucher.
  • Respecter les consignes de montage, et notamment les couples de serrage.
  • Ne pas laisser pénétrer de liquide ni de corps étrangers à l'intérieur du produit. Le non-respect de cette directive peut entraîner, des lésions corporelles graves ou des dommages matériels. Die Nichtbeachtung dieser Anweisung kann Körperverletzung oder Materialschäden zur Folge haben. GEFAHR VON MATERIALSCHÄDEN UND GEHÄUSEERHITZUNG
  • Die Seitenwände können heiß sein. Lassen Sie das Produkt abkühlen, bevor Sie es berühren.
  • Beachten Sie die Montageanweisungen,
  • Führen Sie keine Flüssigkeiten oder Fremdkörper in das Produkt ein. Si no se respetan estas precauciones pueden producirse graves lesiones, daños materiales. RIESGO DE DAÑOS MATERIALES Y DE SOBRECALENTAMIENTO DE LA UNIDAD
  • Los paneles laterales del producto pueden estar calientes. Esperar que el producto se enfríe antes de tocarlo.
  • Respetar las instrucciones de montaje, y en particular los pares de apretado.
  • No dejar que penetren líquidos o cuerpos extraños en el producto. La mancata osservanza di questa precauzione può causare gravi rischi per l'incolumità personale o danni alle apparecchiature. RISCHIO DI DANNI MATERIALI E D'INVOLUCRO CALDO
  • I pannelli laterali dell'apparecchio possono scottare; lasciar quindi raffreddare il prodotto prima di toccarlo.
  • Seguire le istruzioni di montaggio corrette.
  • Non far entrare liquidi o oggetti estranei in questo apparecchio. 如不能正确执行这些操作说明, 极有可能造成严重人体伤害或者设备的损坏。 材料损坏和高温外壳的危险性
  • 产品的一侧面板可能很热,在其冷却前请 不要触碰。
  • 遵照正确的安装说明,包括扭矩值。
  • 请勿让液体及其他异物进入本产品。 DANGER / PELIGRO / DANGER /GEFAHR / PERICOLO / 危险 HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH.
  • Disconnect all power before installing or working with this equipment.
  • Verify all connections and replace all covers before turning on power. Failure to follow these instructions will result in death or serious injury. RIESGO DE DESCARGA ELECTRICA O EXPLOSION.
  • Desconectar todos los suministros de energia a este equipo antes de trabajar con este equipo.
  • Verificar todas las conexiones y colocar todas las tapas antes de energizer el equipo. El incumplimiento de estas instrucciones puede provocar la muerte o lesiones serias. RISQUE DE DESCHARGE ELECTRIQUE OU EXPLOSION
  • Eteindre toutes les sources d'énergie de cet appareil avant de travailler dessus de cet appareil
  • Vérifier tous connections, et remettre tous couverts en olace avant de mettre sous De non-suivi de ces instructions provoquera la mort ou des lésions sérieuses sérieuses. GEFAHR EINES ELEKTRISCHE N SCHLAGES ODER EINER EXPLOSION.
  • Stellen Sie jeglichen Strom ab, der dieses Gerät versorgt, bevor Sie an dem Gerät Arbeiten durchführen
  • Vor dem Drehen auf Energie alle Anschlüsse überprüfen und alle Abdeckungen ersetzen. Unterlassung dieser Anweisungen können zum Tode oder zu schweren Verletzungen führen. RISCHIO DI SCOSSA ELETTRICA O DELL’ESPLOSIONE.
  • Spenga tutta l'alimentazione che fornisce questa apparecchiatura prima di lavorare a questa apparecchiatura
  • Verificare tutti i collegamenti e sostituire tutte le coperture prima dell’accensione L'omissione di queste istruzioni provocherà la morte o lesioni serie 存在电击、 爆炸或电弧 闪烁危险
  • 在操作此设 备之前请先 关闭电源。 若不遵守这些说明, 可能会导致严重的 人身伤害甚至死亡。

Do not forget to visit us at: www.crydom.com Copyright © 2017 Crydom Inc. Specifications subject to change without notice. ANNEX - ENVIROMENTAL INFORMATION The environmental information disclosed in this annex including the EIP Pollution logo are in compliance with People’s Republic of China Electronic Industry Standard SJ/T11364 – 2006, Marking for Control of Pollution Caused by Electronic Information Products. Part Name Toxic or hazardous Substance and Elements Lead Mercury Cadmium Hexavalent Polybrominated Polybrominated (Pb) (Hg) (Cd) Chromium (Cr (VI)) biphenyls (PBB) diphenyl ethers (PBDE) Semiconductor die Solder 附件 - 环保信息 此附件所标示的包括电子信息产品污染图标的环保信息符合中华人民共和国电子行业标准 SJ/T11364 - 2006, 电子信息产品污染控制标识要求。 有毒有害物质或元素件部 名称 铅 汞 镉 六价铬 多溴联苯 多溴二苯醚 (Pb) (Hg) (Cd) (Cr (VI)) (PBB) (PBDE) 半导体芯片 焊接点