100016580 TURCK | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 2
Technical content
Features
■Sensor for condition monitoring ■Accurate temperature and humidity measurement ■Sensor-2-cloud compatible ■DC 4-wire, 18…30 VDC ■M12 × 1 male connector ■Configuration and communication via IO- Link v1.1 ■Smart sensor profile 4 ■Continuous process values for temperature and humidity ■Temperature monitoring with adjustable switching thresholds or windows ■Humidity monitoring with adjustable switching thresholds or windows ■Operating hours and switching threshold counter ■Dew point calculation and output as well as temperature and humidity histogram via IO- Link Wiring diagram Functional principle Condition monitoring sensors are specially designed for use in system parts in which
TURCK Inc. | 3000 Campus Drive Minneapolis, MN 55441-2656 | Phone: 763-553-7300 | Application Support: 1-800-544-7769 | Fax 763-553-0708 | www.turck.com 2|2 CMTH-M12-IOL6X2-H1141 | 01/16/2024 23-00 | technical changes reserved Technical data max. load current Io 50 mA Response time RH % (t63) 6 Setting option IO-Link IO-Link IO-Link specification V 1.1 IO-Link port type Class A Communication mode COM 3 (230.4 kBaud) Process data width 64 bit Measured value information 24 bit Switchpoint information 4 bit Frame type 2.2 Minimum cycle time 10 ms Function pin 4 IO-Link Function Pin 2 SIO Maximum cable length 20 m Profile support Smart Sensor Profile Mechanical data Design Cylindrical/threaded, M12 Dimensions Ø 12 x 57 mm Housing material Metal, CuZn, Chrome-plated Electrical connection Connector, M12 × 1 Ambient temperature -40…+100 °C Storage temperature -40…+100 °C Process Pressure 10 bar Protection class IP67 Power-on indication LED, Green Tests/approvals MTTF 610 years Vibration resistance IEC 60060-2-6: (10…150 Hz) 20 g Shock test IEC 60068-2-27: 50 g (6 ms) EMV EN 61326-1 Approvals CE, UL the environmental parameters can have a significant influence on machine availability or process quality. By monitoring the application temperature or the humidity within the application, process deviations can be detected at an early stage and countermeasures initiated. For this purpose, the continuous detection value is transferred to the controller via IO-Link process data and customer-specific limit value exceedance/ shortfall is additionally transported. The robust sensor design can be used indoors as well as outdoors for more challenging applications.