CMH08A TOSHIBA | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 5
Technical content
TOSHIBA High Efficiency Rectifier Silicon Epitaxial Type CMH08A Switching Mode Power Supply Applications
- Repetitive peak reverse voltage: VRRM = 400 V
- Average forward current: IF (AV) = 2.0 A
- Low forward voltage: VFM=1.8 V(Max.)
- Very Fast Reverse-Recovery Time: trr =35ns(Max.)
- Suitable for compact assembly due to small surface-mount package “M −FLATTM” (Toshiba package name) Absolute Maximum Ratings (Ta = 25°C) Characteristics Symbol Rating Unit Repetitive peak reverse voltage V RRM 400 V Average forward current IF (AV) 2.0 (Note 1) A Peak one cycle surge forward current (non-repetitive) IFSM 20 (50 Hz) A Junction temperature Tj −40~150 °C Storage temperature range Tstg −40~150 °C Note 1: T ℓ=99°C Device mounted on a seramic board board size: 50 mm × 50 mm soldering land: 2 mm × 2 mm board thickness:0.64t Note 2: Using continuously under heavy loads (e.g. the application of high temperature/current/voltage and the significant change in temperature, etc.) may cause this product to decrease in the reliability significantly even if the operating conditions (i.e. operating temperature/current/voltage, etc.) are within the absolute maximum ratings. Please design the appropriate reliability upon reviewing the Toshiba Semiconductor Reliability Handbook (“Handling Precautions”/Derating Concept and Methods) and individual reliability data (i.e. reliability test report and estimated failure rate, etc). Electrical Characteristics (Ta = 25°C) Characteristics Symbol Test Condition Min Typ. Max Unit VFM (1) I FM = 0.1 A (pulse test) ⎯ 0.88 ⎯ VFM (2) I FM = 1.0 A (pulse test) ⎯ 1.3 ⎯ Peak forward voltage VFM (3) I FM = 2.0 A (pulse test) ⎯ 1.6 1.8 V Peak repetitive reverse current I RRM V RRM = 400 V (pulse test) ⎯ ⎯ 10 μA Reverse recovery time trr I F = 1 A, di/dt = −30 A/μs ⎯ ⎯ 35 ns Forward recovery time tfr I F = 1.0 A ⎯ ⎯ 100 ns Device mounted on a ceramic board (board size: 50 mm × 50 mm) (soldering land: 2 mm × 2 mm) (board thickness: 0.64 t) ⎯ ⎯ 60 Device mounted on a glass-epoxy board (board size: 50 mm × 50 mm) (soldering land: 6 mm × 6 mm) (board thickness: 1.6 t) ⎯ ⎯ 135Thermal resistance (junction to ambient) R th (j-a) Device mounted on a glass-epoxy board (board size: 50 mm × 50 mm) (soldering land: 2.1 mm × 1.4 mm) (board thickness: 1.6 t) ⎯ ⎯ 210 °C/WThermal resistance (junction to lead) Rth (j-ℓ) ⎯ ⎯ ⎯ 16 °C/W Unit: mm JEDEC ― JEITA ― TOSHIBA 3-4E1A Weight: 0.023 g (typ.)
Type code Product No. H8 CMH08A Standard Soldering Pad Handling Precaution The absolute maximum ratings mean the absolute maximum ratings, which are rated values and must not be exceeded during operation, even for an instant. The followings are the general derating method that we recommend when you design a circuit with a device. VRRM: We recommend that the worst case voltage, including surge voltage, be no greater than 80% of the absolute maximum rating of VRRM for a DC circuit and be no greater than 50% of that of VRRM for an AC circuit. VRRM has a temperature coefficient (0.1%/℃). Please consider this temperature coefficient when you design a device at low temperature. IF(AV): We recommend that the worst case current be no greater than 80% of the absolute maximum rating of IF(AV). Please do the sufficient heat design. If you can’t design a circuit with excellent heat radiation, please set a margin by using an allowable Tamax-IF (AV) curve. This rating specifies the non-repetitive peak current in one cycle of a 50-Hz sine wave, condition angle 180°. Therefore, this is only applied for an abnormal operation, which seldom occurs during device’s lifespan. We recommend that a device be used Tj of below 120℃ under the worst load and heat radiation conditions. Thermal resistance between junction and ambient fluctuates depending on device’s mounting condition. When using a device, please design a circuit board and a soldering land size to match the appropriate thermal resistance value. Please refer to Rectifier databook for further information. 3.0 1.4 2.1 Unit: mm 1.4
Average forward current I F (AV) (A) Tℓ max – IF (AV) Maximum allowable lead temperature Tℓ max (°C) Average forward current I F (AV) (A) PF (AV) – IF (AV) Average forward power dissipation PF (AV) (W) 0.4 0.8 1.2 160 100 120 140 Instantaneous forward voltage v F (V) iF – vF Instantaneous forward current i F (A) 0.5 0.01 100 1.0 1.5 2.0 150°C Tj = 25°C 75°C 3.5 0.1 2.0 1.6 2.0 2.8 Pulse test Average forward current I F (AV) (A) Ta max – IF (AV) Average allowable ambient temperature Ta max (°C) 160 100 120 140 1000 100 0.001 1000 0.01 0.1 100 10 1 300 500 0.003 0.03 0.3 3 30 300 Transient thermal impedance rth (j-a) (°C/W) Time t (s) rth (j-a) – t 2.5 2.4 2.4 3.0 360° 180° Rectangular Waveform 360° 180° Rectangular Waveform 360° 180° Rectangular Waveform Device mounted on a glass-epoxy board: board size: 50 mm × 50 mm Soldering land: 6.0 mm × 6.0 mm board thickness: 1.6 t Device mounted on a glass-epoxy board: board size: 50 mm × 50 mm Soldering land: 2.1 mm × 1.4 mm board thickness: 1.6 t Device mounted on a glass-epoxy board: board size: 50 mm × 50 mm Soldering land: 6.0 mm × 6.0 mm board thickness: 1.6 t Device mounted on a ceramic board: board size: 50 mm × 50 mm Soldering land: 2.0 mm × 2.0 mm board thickness: 0.64 t
Ta = 25°C f = 50 Hz Number of cycles Surge forward current (non-repetitive) Peak surge forward current I FSM (A) Junction capacitance C j (pF) Reverse voltage V R ( V ) Cj – VR (Typ.) 10 100 100 Ta = 25°C f = 1 MHz
RESTRICTIONS ON PRODUCT USE 20070701-EN
- The information contained herein is subject to change without notice.
- TOSHIBA is continually working to improve the quality and reliability of its products. Nevertheless, semiconductor devices in general can malfunction or fail due to their inherent electrical sensitivity an d vulnerability to physical stress. It is the responsibility of the buyer, when utilizing TOSHIBA produc ts, to comply with the standards of safety in making a safe design for the entire system, and to avoid situations in which a malfunction or failure of such TOSHIBA products could cause loss of human life, bodily injury or damage to property. In developing your designs, please ensure that TOSHIBA products are used within specified operating ranges as set forth in the most recent TOSHIB A products specifications. Also, please keep in mind the precautions and conditions set forth in the “Handling Guide for Semiconduct or Devices,” or “TOSHIBA Semiconductor Reliability Handbook” etc.
- The TOSHIBA products listed in this document are in tended for usage in general electronics applications (computer, personal equipment, office equipment, measuring equipment, industrial robotics, domestic appliances, etc.).These TOSHIBA products are neither intended nor warranted for usage in equipment that requires extraordinarily high quality and/or reliability or a malfuncti on or failure of which may cause loss of human life or bodily injury (“Unintended Usage”). Unintended Usage incl ude atomic energy control instruments, airplane or spaceship instruments, transportation instruments, traffic signal instruments, combustion control instruments, medical instruments, all types of safety devices, et c.. Unintended Usage of TOSHIBA products listed in his document shall be made at the customer’s own risk.
- The products described in this document shall not be used or embedded to any downstream products of which manufacture, use and/or sale are prohibited under any applicable laws and regulations.
- The information contained herein is presented only as a guide for the applications of our products. No responsibility is assumed by TOSHIBA for any infringement s of patents or other rights of the third parties which may result from its use. No license is granted by implic ation or otherwise under any patents or other rights of TOSHIBA or the third parties.
- Please contact your sales representative for product- by-product details in this document regarding RoHS compatibility. Please use these products in this document in compliance with all applicable laws and regulations that regulate the inclusion or use of controlled substances. Toshiba assumes no liability for damage or losses occurring as a result of noncompliance with applicable laws and regulations.