DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 15

Technical content

Features

  • Compact size 50.8 mm x 101.6 mm x 36.1 mm (2 in x 4 in x 1.4 in) with density of 18W/in3
  • Universal AC Input Range (90 – 264VAC)
  • Output voltage of 12V (adjustable ±5%)
  • Maximum output current of 16.7A@ 12Vout (200W)
  • Standby output of 5V or 3.3V @ 0.25A
  • High efficiency with 80 PLUS® Gold Certification
  • Full load capability at 50ºC and 1m/s (200LFM) airflow with derating at higher temperatures or lower airflows
  • Remote ON/OFF
  • Output overcurrent protection (non-latching)
  • Overtemperature protection
  • Output overvoltage protection
  • Up to 12ms of holdup time
  • Parallellable with current sharing
  • Active power factor corrected input
  • Conducted EMI - meets CISPR22 (EN55022) and FCC Class A requirements
  • Compliant to RoHS EU Directive 2002/95/EC
  • UL and cUL approved to UL/CSA60950-1, TUV (EN60950-1), CE Mark (for LVD) and CB Report available
  • ISO** 9001 and ISO 14001 certified manufacturing facilities

Applications

  • Telecommunications equipment
  • Embedded Computing
  • Storage Systems
  • Industrial equipment

Description

In a small 2 x 4 inch footprint, the 12Vdc single-output CLP0212 open frame power supply delivers 80 PLUS Gold energy efficiency. With its small size, t he CLP series is specifically designed to handle power challenges associated with tight space and low airflow. Offering a leading 18W/in3 power density in a 1U high, fan- less form factor, the CLP series addresses a broad range of applications in new products from communications, computing and data storage original equipment manufacturers (OEMs). It delivers greater than 90 percent typical power efficiency and full load output at +50˚C (122˚F) with higher temperature operation possible at derated output. The CLP series utilizes a unique design approach at this power level, leveraging zero voltage switching techniques in conjunction with quasi-resonant power factor correction (PFC) circuits. Protection features include overcurrent (OCP), overvoltage (OVP), and overtemperature (OTP). * UL is a registered trademark of Underwriters Laboratories, Inc. † CSA is a registered trademark of Canadian Standards Association. ‡ VDE is a trademark of Verband Deutscher Elektrotechniker e.V. ** ISO is a registered trademark of the International Organization of Standards

CLP0212 Open Frame Power Supply 90 - 264Vac input; 12Vdc output; 200W Output Power October 11, 2013 ©2012 General Electric Corporation. All rights reserved. Page 2 Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability. Parameter Device Min Max Unit Input Voltage - Continuous All 90 264 Vac Operating Ambient Temperature All -25 70 °C (see Thermal Considerations section) CLP0212FPEX5Z01A -40‡ 70 °C CLP0212FPEXZ02A CLP0212FPEX5Z03A -40‡ 85* °C (in sealed enclosure applications with thermally conductive pad to enclosure, PO,max = 65W) CLP0212FPEX5Z02A -40 55† °C (in sealed enclosure applications with thermally conductive pad to enclosure, PO,max = 110W) CLP0212FPEX5Z03A -40 55† °C Storage Temperature All -40 85 °C Humidity (non-condensing) All 5 95 % Altitude All 4000 m ‡ Startup at -40ºC is limited to 80% of maximum load (160W) for all versions, except the CLP0212FPEXZ02A which can start up at full load. * Unit is capable of operation up to 85ºC ambient for brief periods of time provided humidity is kept below 40%. Sustained operation at 85ºC when input voltage is above 230VAC and output power loading is at or near the maximum rated value can degrade reliability of the product. † Ambient temperature outside the sealed enclosure containing the power supply. Electrical Specifications Parameter Device Min Typ Max Unit Operating Input Voltage All 90 115/230 264 Vac Input Source Frequency All 47 50/60 63 Hz Input Current (VIN = 90Vac) All versions except CLP0212FPEXZ02A 4 ARMS CLP0212FPEXZ02A 1.6 ARMS Input Power Factor All 0.95 Inrush Transient Current (VIN = 264Vac, Tamb = 25ºC) All 100 A Peak Leakage Current to earth ground (VIN = 264Vac) All 2 mA Output Voltage Setpoint All 12 Vdc Output Voltage Tolerance (due to set point, temperature variations, load and line regulation) All -2 2 % Output Voltage Adjustment Range All 11.4 12.6 Vdc Output Remote Sense Range All 250 mVdc Output Load Regulation All 1.5 %Vout Output Line Regulation All 0.5 %Vout Output Ripple and Noise – measured with 0.1µF ceramic capacitor in parallel with 10µF tantalum capacitor, at 25°C1 Peak-to-peak (20MHz Bandwidth) All 180 mV p-p Dynamic Load Response – 50% to 75% load transient, 0.1A/µs slew rate Output voltage deviation Settling Time All All 500 µs Output Current All versions except CLP0212FPEXZ02A 0 16.7 Adc Output Current CLP0212FPEXZ02A 0 8.34 Adc Output Current Limit Inception All 115 % IO,max 1 Output ripple is 300mV p-p maximum at -40°C. To reduce further, additional external capacitance needed.

CLP0212 Open Frame Power Supply 90 - 264Vac input; 12Vdc output; 200W Output Power October 11, 2013 ©2012 General Electric Corporation. All rights reserved. Page 3 Electrical Specifications (cont.) Parameter Device Min Typ Max Unit Maximum Output Capacitance All 5000 µF Standby Output Voltage CLP0212FPXX5Z01A CLP0212FPEX5Z01A 5 Vdc CLP0212FPXX3Z01A 3.3 Vdc Standby Output Current All 0.25 Adc Efficiency: VIN = 230Vac, 20% load All except ..Z02A 86.8 % 50% load All except ..Z02A 91.1 % 100% load All except ..Z02A 89.5 % VIN = 115Vac, 20% load All except ..Z02A 89.2 % 50% load All except ..Z02A 90.3 % 100% load All except ..Z02A 87.1 % Holdup Time – VIN = 115Vac, 100% load2 65W load for CLP0212FPEXZ02A All except ..Z02A CLP0212FPEXZ02A 10 45 ms VIN = 230Vac, 100% load 65W load for CLP0212FPEXZ02A All except ..Z02A CLP0212FPEXZ02A 10 45 ms Isolation Specifications Parameter Device Min Max Unit Isolation Voltage – Input to output All 3000 Vac Input to safety ground All 1500 Vac Outputs to safety ground All 50 Vac General Specifications Parameter Device Symbol Typ. Unit Calculated Reliability based on Telcordia SR-332 Issue 2: Method 1 Case 3 (VIN=230Vac, Io = 16.7A, TA = 40ºC, airflow 200LFM, 90% confidence) All FIT MTBF 1,011.9 988,276 109/Hours Hours Weight All 185 6.5 g oz. Feature Specifications Parameter Device Min Typ Max Unit On/Off Signal Interface – signal referenced to GND Logic Low (Power Supply ON) Input Low Current All 7 mA Input Low Voltage All 1 V Logic High (Power Supply OFF) Input High Current All 600 µA Input Voltage All 5.5 V Delay from ON/OFF being enabled to start of output voltage rise All 50 ms Output Voltage Rise Time (from 10 to 90% of final value) All 5 ms Delay from Input being applied to standby output being in regulation All 12 ms Delay from Input being applied to all outputs being in regulation All 30 ms Output Holdup time (from loss of AC to output being out of regulation) All 10 ms Output Overvoltage Protection (for main output currents above 0.1A) All 13.8 18 Vdc

2 Holdup time is reduced at cold temperatures

CLP0212 Open Frame Power Supply 90 - 264Vac input; 12Vdc output; 200W Output Power October 11, 2013 ©2012 General Electric Corporation. All rights reserved. Page 4 Feature Specifications (cont.) Parameter Device Min Typ Max Unit Input Undervoltage lockout3 Turn-on Threshold (100% load) All 86 Vac Turn-off Threshold (100% load) All 82 Vac DC OK – open collector, High when output available Sink Current All 4 mA Maximum Collector Voltage All 12 V Environmental Specifications Parameter Device Specification Conducted Emissions All CISPR22 (EN55022) Class A with 3dB margin Input Harmonics All EN61000-3-2 ESD All IEC 61000-4-2, Level 3 Radiated Immunity All IEC 61000-4-3, Level 2* Electrical Fast Transient Common Mode All IEC 61000-4-4, Level 3 Surge Immunity All IEC 61000-4-5, Level 3 Conducted RF Immunity All IEC 61000-4-6, Level 3 Voltage Dips All EN61000 4.11, Level 3, Class B, C Shock and Vibration Operating Shock All Three shocks, 15G peak, 11ms sine wave, two axes Non-Operating Shock All Three shocks, 50G peak, 11ms sine wave, two axes Operating and Non-Operating Vibration All 5 – 9Hz, 0.5” double amplitude, 2G Peak, 0.5 oct./min., 2 cycles 9-500Hz, 4G pk-pk, 0.5 oct/min., 2 cycles * Radiated immunity is met when the power supply is tested in a suitable enclosure. 3 The undervoltage lockout thresholds vary with output load current level – decreasing as the load goes down

CLP0212 Open Frame Power Supply 90 - 264Vac input; 12Vdc output; 200W Output Power October 11, 2013 ©2012 General Electric Corporation. All rights reserved. Page 7 Safety Considerations The CLP0212 power supply is intended for inclusion in other equipment and the installer must ensure that it is in compliance with all the requirements of the end application. This product is only for inclusion by professional installers within other equipment and must not be operated as a stand-alone product. The power supply meets Class 1, IEC60950, EN60950, with the following deviations: Nemko. UL 60950 (Recognized Component) C-UL (Canadian Approval by UL). Feature Descriptions Standby Power Supply A standby output in the CLP0212 power supply of either 3.3 or 5V, comes on when AC input in the operating range is applied. In the Z02A and Z03A versions of the power supply, the standby output is not accessible. Remote On/Off All versions of the CLP0212 power supply except the Z02A and Z03A versions feature a TTL-compatible On/Off control input. The power supply turns ON when the On/Off input goes low, and turns OFF when the input goes high. Note that if the On/Off pin is left unconnected, the power supply main output remains off. Figure 9 shows the circuit configuration for using the On/Off pin. Either a suitable semiconductor device such as a BJT or FET or a mechanical switch can be used to turn the power supply On and Off. The switch must be capable of handling the On/Off pin current which may be up to 6mA when closed. The switch On voltage drop must also be sufficiently small so that the photo diode inside the power supply is turned ON when the external switch is ON. Note that the standby output voltage could be either 3.3V or 5V depending on the CLP0212 power supply variant selected. If no On/Off control is desired, the On/Off pin can be externally connected to the COM pin and the power supply will automatically turn ON when AC input is within range. Fig. 9. Schematic showing ON/OFF circuitry. Output Voltage Adjustment Fig. 10. Diagram showing location of the potentiometer used to adjust the power supply output voltage. The output voltage can be adjusted between 11.4V and 12.6V using a potentiometer on the power supply. See Fig. 10 for a diagram showing location of the potentiometer. Remote Sense The power supply has both positive and negative remote sense connections that can be connected to the positive and negative rails of the main output near the load. Care should be taken in routing the sense lines to ensure that noise is not picked up or that additional filtering elements that affect the stability of the power supply are not used. The power supply will operate without the remote sense connections being made, however if remote sense near the load is not used it is recommended that the remote sense lines be connected directly to the main output terminals. Overcurrent Protection To provide protection in a fault condition (output overload), the power supply is equipped with internal current-limiting circuitry and can endure current limiting continuously. At the point of current-limit inception, the unit enters hiccup mode. The power supply operates normally once the output current is brought back into its specified range. Overvoltage Protection Overvoltage protection is a feature of the CLP0212 power supply that protects both the load and the power supply from an output overvoltage condition. When an overvoltage occurs, the power supply shuts down and goes into hiccup mode until the overvoltage condition is removed. It is not necessary to recycle the input to restart the power supply when this protection is activated. Overtemperature Protection The CLP0212 also features overtemperature protection in order to provide additional protection in a fault condition. The power supply is equipped with a thermal shutdown circuit which detects excessive internal temperatures and shuts the unit down. Once the power supply goes into overtemperature shutdown, it will cool before attempting to restart. The overtemperature protection circuit will typically activate when the unit is operated at 200W output with an ambient temperature of 60ºC and 1m/s (200LFM) airflow. 3.65K SWITCH 1 2 STANDBY OUTPUT COM ON/OFF CLP POWER SUPPLY Potentiometer

available and within regulation. output voltage is above 10V. within ±5% of the full load value. needs to be connected in series with each output. to ensure reliable operation. here is based on measurements taken in a wind tunnel. derating information in other airflow directions. Fig. 11. Preferred airflow direction for cooling. operation as shown in Table 1. Table 1. Output Power Capability when the CLP0212 is

CLP0212 Open Frame Power Supply 90 - 264Vac input; 12Vdc output; 200W Output Power October 11, 2013 ©2012 General Electric Corporation. All rights reserved. Page 9 EMI performance All CLP0212 power supplies are specified to meet conducted Class A EMI requirements per CISPR 22 (EN55022) with at least 3dB of margin. Results of tests conducted without any external filtering are shown below. These indicate 10dB or better of margin over the Class A limits. CLP0212FPXX5Z01A (120VAC in, 12V @ 180W out, Negative of Output Grounded) CLP0212FPXX5Z01A (208VAC in, 12V @ 180W out, Negative of Output Grounded)

CLP0212 Open Frame Power Supply 90 - 264Vac input; 12Vdc output; 200W Output Power October 11, 2013 ©2012 General Electric Corporation. All rights reserved. Page 10 CLP0212FPEX5Z03A (120VAC in, 12V @ 180W out, Negative of Output Grounded) CLP0212FPEX5Z03A (208VAC in, 12V @ 180W out, Negative of Output Grounded)

CLP0212 Open Frame Power Supply 90 - 264Vac input; 12Vdc output; 200W Output Power October 11, 2013 ©2012 General Electric Corporation. All rights reserved. Page 11 Mechanical Outline (all except CLP0212…Z02A & CLP0212…Z03A versions) Dimensions are in millimeters. Tolerances: x.x mm ± 0.5mm [unless otherwise indicated] x.xx mm ± 0.25mm TOP VIEW SIDE VIEW 3D-VIEW

CLP0212 Open Frame Power Supply 90 - 264Vac input; 12Vdc output; 200W Output Power October 11, 2013 ©2012 General Electric Corporation. All rights reserved. Page 12 Mechanical Outline - CLP0212FPEXZ02A Dimensions are in millimeters. Tolerances: x.x mm ± 0.5mm [unless otherwise indicated] x.xx mm ± 0.25mm TOP VIEW SIDE VIEW 3D-VIEW

CLP0212 Open Frame Power Supply 90 - 264Vac input; 12Vdc output; 200W Output Power October 11, 2013 ©2012 General Electric Corporation. All rights reserved. Page 13 Mechanical Outline - CLP0212FPEX5Z03A Dimensions are in millimeters. Tolerances: x.x mm ± 0.5mm [unless otherwise indicated] x.xx mm ± 0.25mm TOP VIEW SIDE VIEW 3D-VIEW

CLP0212 Open Frame Power Supply 90 - 264Vac input; 12Vdc output; 200W Output Power October 11, 2013 ©2012 General Electric Corporation. All rights reserved. Page 14 Connector Information Pinout Information Note: Signal Connector HD3 is not present in the Z02A and Z03A versions. Connector Connector on Power Supply Mating Connector AC Input Connector (HDR1) 5-1376382-1 from Tyco or equivalent 1376388-1 from Tyco or equivalent DC Output Connector (HDR2) 39-28-1043 from Molex or equivalent 39-01-2040 from Molex or equivalent Signal Connector (HDR3) 53047-0810 from Molex or equivalent 51021-0800 from Molex or equivalent AC Input Connector (HDR1) DC Input Connector (HDR2) Signal Connector (HDR3) Pin 1 Line Pin 1 VO Pin 1 Current Share Pin 2 Neutral Pin 2 VO Pin 2 +S (Remote Sense +) Pin 3 RTN Pin 3 -S (Remote Sense -) Pin 4 RTN Pin 4 Remote On/Off Pin 5 DC-OK (Output OK) Pin 6 COM (Output Return) Pin 7 COM (Output Return) Pin 8 Standby Output

CLP0212 Open Frame Power Supply 90 - 264Vac input; 12Vdc output; 200W Output Power Contact Us For more information, call us at USA/Canada: +1 888 546 3243, or +1 972 244 9288 Asia-Pacific: +86.021.54279977*808 Europe, Middle-East and Africa: +49.89.878067-280 India: +91.80.28411633 www.gecriticalpower.com October 11, 2013 ©2012 General Electric Corporation. All rights reserved. Version 1.26

Ordering Information

Please contact your Lineage Power Sales Representative for pricing, availability and optional features. Table 2. Device Codes