Features

Universal AC input / Full range • Protections: Short circuit / Overload / Over voltage / Over • temperature Built-in active PFC function, PF>0.9 for 75% of load or higher• IP67 / IP65 design for indoor or outdoor installations (exclude C type)• OCP point adjustable through output cable or internal potential meter • (CLG-150 / 240) UL1310 class2 power unit (CLG-60&100)• Cooling by free air convection• Suitable for LED lighting and moving sign applications• Optional model for CLG-150 / 240:• A-Type: IP65 rated. Output and constant current level can be adjusted through internal potential meter B-Type: IP67 rated and constant current level adjustable through output cable (optional) C-Type: Terminal block for I/O connection (optional) Blank-Type: IP67 rated, cable for I/O connection (optional) 3 years warranty• CLG-60 (IP67) General Specification (Please refer to www.meanwell.com for detail spec.) CLG-100 (IP67) CLG-150 A (IP65) CLG-240 A (IP65) Model No. CLG-60 CLG-100 CLG-150 CLG-240 AC input voltage range 90~264VAC; 127~370VDC 90~280VAC; 127~396VDC AC inrush current (max.) Cold start, 40A at 230VAC Cold start, 65A at 230VAC DC adjustment range Fixed. Can be modified between ±10% (CLG-60) or 0~-15% (CLG-100) rated output voltage A and C type can be adjusted by internal potential meter Current adjustment range Fixed. Can be modified between 75%~103% rated output current Can be adjusted by internal potential meter (A and C type) or through output cable (B type) Overload protection 95%~130% constant current, auto-recovery 95%~102% constant current, auto-recovery 95%~108% constant current limiting, auto-recovery Over voltage protection 110%~140% 107%~135% 110%~140% rated output voltage Setup, rise, and hold up time 1500ms, 150ms, no hold up time 1200ms, 80ms, 60ms at full load and 230VAC 3000ms, 80ms, 20ms at full load and 230VAC Withstand voltage I/P-O/P: 4.25kVDC I/P-O/P: 3.75kVAC, I/P-FG: 1.88kVAC, O/P-FG: 0.5kVAC Working temperature -30~+70 OC (refer to output derating curve) Safety standards UL1310 Class 2, EN61347-1, EN61347-2-13, CAN/ CSA-C22.2 No.223-M91 (except for 48V) approved, TUV EN60950-1 & UL879 (SAM list) also for CLG-100 UL60950-1, UL1012, TUV EN60950-1, EN61347-1, EN61347-2-13 approved (CLG-240 pending) EMC standards EN55015, EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, ENV50204, EN61547 Connection Input UL rated, 18AWGx3C (30cm) UL rated, 18AWGx3C (30cm); Terminal block for C type option Output UL rated, 18AWGx2C (30cm) A & Blank type: 14AWGx2C (30cm) B type: 14AWGx2C (30cm)+18AWGx2C (30cm) C type: Terminal block Dimension (L*W*H)(mm) 172x 61.5x 39 222x 68x 39 222x 68x 39 244x 68x 39 Case No. 957A 954A 954A ----- Packing 16pcs / 14.8kg 12pcs / 13kg 12pcs / 13kg ----- 60~240W Single Output with PFC NEWNEW Stock No. Model No. Output Tol. R&N Effi. 11461 CLG-60-12 12V, 0~5.0A ±10% 2.0V 83.0% 11462 CLG-60-15 15V, 0~4.0A ±10% 2.4V 84.5% 11463 CLG-60-20 20V, 0~3.0A ±10% 1.8V 86.5% 11464 CLG-60-24 24V, 0~2.5A ±10% 2.7V 86.5% 11465 CLG-60-27 27V, 0~2.3A ±10% 2.7V 87.0% 11466 CLG-60-36 36V, 0~1.7A ±10% 3.6V 87.0% 11467 CLG-60-48 48V, 0~1.3A ±10% 4.6V 88.0% 60W (Class 2) CLG-60 INPUT OUTPUT A B C CLG-150 / 240 Blank NEWNEW NEWNEW