CL240D05 SENSATA | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 5

Technical content

Features

  • Ratings from 5A to 10A @ 24-280 VAC
  • Triac Output
  • LED Status Indicator
  • UL Approved, CE Compliant to EN60950-1
  • Improved SEMS screw and washer
  • Redesigned housing with anti-rotation barriers
  • AC or DC control
  • EMC Compliant to Level 3
  • Epoxy free design PRODUCT SELECTION Control Voltage 3-32 VDC CL240D05 10A CL240D10 90-250 VAC CL240A05 CL240A10 Note: Not all part number combinations are available. Contact Crydom Technical support for information on the availability of a specific part number. Serires Control Voltage Load Voltage 240: 24-280 VAC Rated Load Current CL 240 A 10 K R C H ORDERING OPTIONS Required for valid part number For options only and not required for valid part number A: 90-250 VAC D: 3-32 VDC 05: 5 Amps 10: 10 Amps Termination Blank: Screws & clamps K: Installed standoffs with screws for PC Board mounting (IP00 only) (1) Switching Type Blank: Zero Voltage Turn-On R: Instantaneous Turn-On Cover Blank: Not Included (IP00) C: Included (IP20) Thermal Pad Blank: Not Included H: Included CL | CL SERIES www.sensata.comCopyright © 2018 Sensata Technologies, Inc.

GENERAL SPECIFICATIONS (2) ParametersDescription Dielectric Strength, Input to Output (50/60Hz) Dielectric Strength, Input/Output to Ground (50/60Hz)

4000 Vrms

2500 Vrms

Minimum Insulation Resistance (@ 500 VDC) 109 Ohms Maximum Capacitance, Input/Output 8 pF Ambient Operating Temperature Range (7) -40 to 80 °C Ambient Storage Temperature Range -40 to 125 °C Weight (typical) 2.88 oz (81.53 g) Housing Material UL94 V-0 Baseplate Material Aluminum Input Terminal Screw Torque Range (in-lb/Nm) 13-15 /1.5-1.7 Load Terminal Screw Torque Range (in-lb/Nm) 18-20 / 2-2.2 Input/Load Terminal Screw Torque Range (in-lb/Nm) (1) w/”K” option 8-10 / 0.9-1.13 SSR Mounting Screw Torque Range (in-lb/Nm) 18-20 / 2-2.2 Humidity per IEC60068-2-78 93% non-condensing LED Input Status Indicator Green MTBF (Mean Time Between Failures) at 40°C ambient temperature (8) 11,641,553 hours (1,328 years) MTBF (Mean Time Between Failures) at 60°C ambient temperature (8) 7,210,376 hours (823 years) WIRING DIAGRAM Recommended Wire Sizes Terminals Wire Size (Solid / Stranded) Wire Pull-Out Strength (lbs)[N] Input Output 24 AWG (0.2 mm 2) / 0.2 [minimum] 2 x 12 AWG (3.3 mm 2) / 3.3 [maximum] 20 AWG (0.5 mm 2) / 0.518 [minimum] 2 x 10 AWG (5.3 mm 2) / 5.3 2 x 8 AWG (8.4 mm 2) / 8.4 [maximum] 10 [44.5] 90 [400] 30 [133] 110 [490] 90 [400] S OLI D S T AT E R ELA Y OUTPUT INPUT Load (9) V 4 (– / ) 3 (+ / ) 1 ( ) 2 ( ) AC Input/Output Terminal Screw Thread Size #6-32 UNC / #8-32 UNC Page 2 OUTPUT SPECIFICATIONS (2) Description 5 A Operating Voltage (47-63Hz) [Vrms] 24-280 Transient Overvoltage [Vpk] (3) 600 Maximum Off-State Leakage Current @ Rated Voltage [mArms] 7 Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] 500 Maximum Load Current [Arms] (4) 5 Minimum Load Current [mArms] 150 Maximum 1 Cycle Surge Current (50/60Hz)[Apk] 84/100 Maximum On-State Voltage Drop @ Rated Current [Vpk] 1.6 Thermal Resistance Junction to Case (Rjc) [°C/W] 2.3 Maximum 1/2 Cycle I² t for Fusing (50/60Hz)[A²sec] 35/42 Minimum Power Factor (with Maximum Load) 0.5 10 A 24-280 600 500 150 1.5 2.3 0.5 Minimum Heat Sink for Rated Current @ 40°C [°C/W] 3 1.5 INPUT SPECIFICATIONS (2) Description AC Control Control Voltage Range 90-250 VAC Maximum Reverse Voltage - Minimum Turn-On Voltage 90 VAC Must Turn-Off Voltage 10 VAC Minimum Input Current (for on-state) 6 mA Maximum Input Current 10 mA Nominal Input Impedance Current Limited Maximum Turn-On Time [msec] 20 Maximum Turn-Off Time [msec] 30 DC Control 3-32 VDC (5) -32 VDC

3 VDC

1 VDC

1/2 Cycle (6) 1/2 Cycle www.sensata.comCopyright © 2018 Sensata Technologies, Inc.

MECHANICAL SPECIFICATIONS(2) (1) Tolerances: ±0.02 in / 0.5 mm All dimensions are in: inches [millimeters] Screw Termination

1 OUTPUT 2

4 INPUT 3

1.1 [27.9] 0.49 [12.4] Mounting Hole/Slot 0.19 [4.9] DIA. 0.89 [22.6] 1.88 [47.6] 1.7 [43.2] 2.25 [57.3] 1.0 [25.4] 1.75 [44.5] 1.0 [25.4] 1.75 [44.5] Hex Standoff Termination (“K” Option) 1.1 [27.9] 0.49 [12.4] Mounting Hole/Slot 0.19 [4.9] DIA. 1.88 [47.6] 1.7 [43.2] 2.25 [57.3] 1.0 [25.4] 1.75 [44.5] 1.04 [26.4] (4 places) 0.93 [23.6] 1.0 [25.4] (2 places) (2 places) Mounting Hole/Slot 0.19 [4.9] DIA. 2.25 [57.3] 1.1 [27.9] 0.49 [12.4] 1.88 [47.6] 1.7 [43.2] 2.32 [58.8] 1.0 [25.4] 1.75 [44.5] 1.0 [25.4] 1.75 [44.5] 1.22 [30.9] Screw Termination, IP20 Page 3 EQUIVALENT CIRCUIT BLOCK DIAGRAMS +DC -DC AC Trigger Circuit Current Limiter AC INPUT OUTPUT CL Series DC Control AC AC AC Trigger Circuit Current Limiter AC INPUT OUTPUT AC/DC Converter CL Series AC Control 0 5 10 15 20 25 30 35 Standard Regulated “DC” Inputs Input Current (mA) DC Input Voltage AC Input Voltage Standar Regulated “AC” Inputs Input Current (mA) 0 50 100 150 200 250 www.sensata.comCopyright © 2018 Sensata Technologies, Inc.

THERMAL DERATE INFORMATION (i) SSR metal base plate acting as heat sink, it must be exposed to free ambient air. 100 120 0.01 0.1 1 10 Surge Current (Amp) AC Peak Surge Duration (sec) CL240x10 0.01 0.1 1 10 Surge Current (Amp) AC Peak Surge Duration (sec) CL240x05 Single Pulse (10) 20 30 40 50 60 70 80 CL240x05 Load Current (Amps) Ambient Temperature (ºC) 2°C/W 3°C/W No Heat Sink (i) 20 30 40 50 60 70 80 CL240x10 Load Current (Amps) Ambient Temperature (ºC) 1.5°C/W 2°C/W No Heat Sink (i) Page 4 Part number: KS101 Clear plastic cover compatible with all new S1 designs. Safety covers provide added protection from electric shock when installing or checking equipment. Protective Cover Hardware Kit Part number: HK4 Bag with 2 square brass accessories and 2 screw 8-32 x 5/8 for output. Used to mount TMR1 lug terminals. Protective Cover & Hardware Kits Recommended Accessories Cover Hardware Kit Heat Sink Part No. Thermal Resistance [ºC/W] Lug Terminal Thermal Pad KS101 HK1 HK4 HS501DR HS301 / HS301DR HS251 HS201 / HS201DR HS202 / HS202DR HS172 HS151 / HS151DR HS122 / HS122DR HS103 / HS103DR HS101 HS073 HS072 HS053 HS033 HS023 5.0 3.0 2.5 2.0 2.0 1.7 1.5 1.2 1.0 1.0 0.7 0.7 0.5 0.36 0.25 TRM1 TRM6 HSP-1 HSP-2 ACCESORIES www.sensata.comCopyright © 2018 Sensata Technologies, Inc.

AGENCY APPROVALS AND CERTIFICATIONS IEC 61000-4-2 Electrostatic Discharge Level 3 IEC 61000-4-4 Electrically Fast Transients Level 3 E46203 GENERAL NOTES (2) All parameters at 25°C unless otherwise specified. (3) Output will self trigger between 450-600Vpk, not suituable for capacitive loads. (4) Heat sinking required, see derating curves. (5) Increase minimum voltage by 1V for operations from -20 to -40°C. (6) Turn-on time for instantaneous turn-on versions is 0.1 msec. (7) AC models operating range is -20 to 80 °C. (8) All parameters at 50% power rating and 100% duty cycle (contact Crydom tech support for detailed report). (9) Load can be wired to either SSR output terminal 1 or 2. (10) For single surge pulse Tc=25° C; Tj=125°C. For AC Output SSRs, AC Rms value of surge current equals the peak value divided by √2 (1.414). For additional information or specific questions, contact Crydom Technical Support. Page 5 WARNINGS RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE

  • The product’s side panels may be hot, allow the product to cool before touching.
  • Follow proper mounting instructions including torque values.
  • Do not allow liquids or foreign objects to enter this product. Failure to follow these instructions can result in serious injury, or equipment damage. HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH
  • Disconnect all power before installing or working with this equipment.
  • V erify all connections and replace all covers before turning on power. Failure to follow these instructions will result in death or serious injury. CONTACT USSensata Technologies, Inc. (“Sensata”) data sheets are solely intended to assist designers (“Buyers”) who are developing systems that incorporate Sensata products (also referred to herein as “components”). Buyer understands and agrees that Buyer remains responsible for using its independent analysis, evaluation and judgment in designing Buyer’s systems and products. Sensata data sheets have been created using standard laboratory conditions and engineering practices. Sensata has not conducted any testing other than that specifically described in the published documentation for a particular data sheet. Sensata may make corrections, enhancements, improvements and other changes to its data sheets or components without notice. Buyers are authorized to use Sensata data sheets with the Sensata component(s) identified in each particular data sheet. HOWEVER, NO OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE TO ANY OTHER SENSATA INTELLECTUAL PROPERTY RIGHT, AND NO LICENSE TO ANY THIRD PARTY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT, IS GRANTED HEREIN. SENSATA DATA SHEETS ARE PROVIDED “AS IS”. SENSATA MAKES NO WARRANTIES OR REPRESENTATIONS WITH REGARD TO THE DATA SHEETS OR USE OF THE DATA SHEETS, EXPRESS, IMPLIED OR STATUTORY, INCLUDING ACCURACY OR COMPLETENESS. SENSATA DISCLAIMS ANY WARRANTY OF TITLE AND ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, QUIET ENJOYMENT, QUIET POSSESSION, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL PROPERTY RIGHTS WITH REGARD TO SENSATA DATA SHEETS OR USE THEREOF. All products are sold subject to Sensata’s terms and conditions of sale supplied at www.sensata.com SENSATA ASSUMES NO LIABILITY FOR APPLICATIONS ASSISTANCE OR THE DESIGN OF BUYERS’ PRODUCTS. BUYER ACKNOWLEDGES AND AGREES THAT IT IS SOLELY RESPONSIBLE FOR COMPLIANCE WITH ALL LEGAL, REGULATORY AND SAFETY-RELATED REQUIREMENTS CONCERNING ITS PRODUCTS, AND ANY USE OF SENSATA COMPONENTS IN ITS APPLICATIONS, NOTWITHSTANDING ANY APPLICATIONS-RELATED INFORMATION OR SUPPORT THAT MAY BE PROVIDED BY SENSATA. Mailing Address: Sensata Technologies, Inc., 529 Pleasant Street, Attleboro, MA 02703, USA. www.sensata.comCopyright © 2018 Sensata Technologies, Inc. Americas +1 (877) 502 5500 – Option 2 sales.crydom@sensata.com Europe, Middle East & Africa +44 (1202) 416170 ssr-info.eu@sensata.com Asia Pacific sales.isasia@list.sensata.com China +86 (21) 2306 1500 Japan +81 (45) 277 7117 Korea +82 (31) 601 2004 India +91 (80) 67920890 Rest of Asia +886 (2) 27602006 ext 2808 Rev. 04/11/18 ECN 20395 FDE-07-01 Rev. B