CFM-40V CUID | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 11

Technical content

SERIES: CFM-40V | DESCRIPTION: DC AXIAL FAN cuidevices.com

FEATURES

  • omniCOOLTM bearing system
  • 40 x 40 mm frame
  • multiple speed options for different cooling needs
  • tachometer signal and rotation detect options available
  • auto restart protection standard on all models MODEL input voltage input current1 input power1 rated speed1 air flow2 static pres- sure3 noise4 rated (Vdc) range (Vdc) max (mA) max (W) typ (RPM±15%) (CFM) (inch H2O) max (dBA) Notes: 1. At rated voltage, 25°C, 0 inch H20 static pressure, after 10 minutes 2. As per AMCA 210 or DIN 24163, at rated voltage, stabilized RPM, 0 inch H20 static pressure 3. As per AMCA 210 or DIN 24163, at rated voltage, stabilized RPM, 0 CFM airflow. 4. Measured in a semi-anechoic chamber with background noise < 15 dBA at 1 m from the fan intake. 5. All specifications are measured at 25°C, 65% relative humidity unless otherwise specified. PART NUMBER KEY CFM-4010V-058-206 - XX - CXX Reserved for Custom Configurations Base Number Fan Signals “blank” = no signals 11 = rotation detector signal 20 = tachometer signal Additional Resources: Product Page | 3D Model

CUI DEVICES | SERIES: CFM-40V | DESCRIPTION: DC AXIAL FAN date 08/12/2022 | page 2 of 11 cuidevices.com INPUT parameter conditions/description min typ max units operating input voltage1

5 Vdc input models

12 Vdc input models

24 Vdc input models

3.5 4.5 13.8 2 7. 6 Vdc Vdc Vdc starting voltage2 3.5 4.5 Vdc Vdc Vdc Note: 1. See Model section on page 1 for specific input voltage ranges. 2. Starting voltage for model CFM-4010V-158-206 is 6 Vdc. PERFORMANCE3 parameter conditions/description min typ max units rated speed at rated voltage, 25°C, after 10 minutes 4500 8500 RPM air flow at 0 inch H2O, see performance curves 5.4 10.8 CFM static pressure at 0 CFM, see performance curves 0.09 0.29 inch H2O noise at 1 m 12.3 31.4 dBA Note: 3. See Model section on page 1 for specific values. PROTECTIONS / FEATURES4 parameter conditions/description min typ max units auto restart on all models rotation detector signal available on “11” models tachometer signal available on “20” models Notes: 4. See Application Notes for details. SAFETY & COMPLIANCE parameter conditions/description min typ max units insulation resistance of frame at 500 Vdc between internal stator and positive lead wire 10 MΩ dielectric strength apply 500 Vac for 1 minute between housing and positive lead wire safety approvals UL/cUL 507 , TUV (EN 60950-1) EMI/EMC EN 61000-6-1:2007 , EN 61000-6-3:2007+A1 life expectancy at 40°C, 65% RH 70,000 hours RoHS yes ENVIRONMENTAL parameter conditions/description min typ max units operating temperature -10 70 °C storage temperature -40 70 °C Additional Resources: Product Page | 3D Model

CUI DEVICES | SERIES: CFM-40V | DESCRIPTION: DC AXIAL FAN date 08/12/2022 | page 3 of 11 cuidevices.com PERFORMANCE CURVES 0.02 0.04 0.06 0.08 0.1 0.12 02468 Air Flow (CFM) Static Pressure (inch H2 O) 0.5 1.5 2.5 Air Flow (CMM) 0 0.055 0.11 0.165 0.22 Static Pressure (mm H2 O) 0.04 0.08 0.12 0.16 0.2 024 68 00 .055 0.11 0.1650 .22 Air Flow (CFM) Static Pressure (inch H2 O) Air Flow (CMM) Static Pressure (mm H2 O) CFM-4010V-058-206 0.02 0.04 0.06 0.08 0.1 012345 6 0 0.5 1.5 2.5 Air Flow (CFM) Static Pressure (inch H2 O) Air Flow (CMM) Static Pressure (mm H O) 0.02 0.04 0.06 0.08 0.1 0.12 0 2468 0.5 1.5 2.5 00 .055 0.11 0.1650 .22 Air Flow (CFM) Static Pressure (inch H2 O) Air Flow (CMM) Static Pressure (mm H2 O) CFM-4010V-070-273 CFM-4010V-158-206CFM-4010V-150-157 Additional Resources: Product Page | 3D Model

CUI DEVICES | SERIES: CFM-40V | DESCRIPTION: DC AXIAL FAN date 08/12/2022 | page 4 of 11 cuidevices.com PERFORMANCE CURVES (CONTINUED) 0.04 0.08 0.12 0.16 0.2 0246 8 00 .055 0.11 0.1650 .22 Air Flow (CFM) Static Pressure (inch H2 O) Air Flow (CMM) Static Pressure (mm H2 O) 0.05 0.1 0.15 0.2 0.25 0246 81 0 1.27 2.54 3.81 5.08 6.35 Air Flow (CFM) Static Pressure (inch H2 O) Air Flow (CMM) Static Pressure (mm H2 O) CFM-4010V-170-273 Air Flow (CFM) Static Pressure (inch H2 O) Air Flow (CMM) Static Pressure (mm H2 O) 0.02 0.04 0.06 0.08 0.1 0.12 0246 8 0.5 1.5 2.5 00 .055 0.11 0.1650 .22 0.04 0.08 0.12 0.16 0.2 0246 8 00 .055 0.11 0.165 0.22 Air Flow (CFM) Static Pressure (inch H2 O) Air Flow (CMM) Static Pressure (mm H2 O) CFM-4010V-185-314 CFM-4020V-060-210CFM-4020V-050-165 Additional Resources: Product Page | 3D Model

CUI DEVICES | SERIES: CFM-40V | DESCRIPTION: DC AXIAL FAN date 08/12/2022 | page 5 of 11 cuidevices.com PERFORMANCE CURVES (CONTINUED) 0.06 0.12 0.18 0.24 0 24681 0 1.5 4.5 Air Flow (CFM) Static Pressure (inch H2 O) Air Flow (CMM) Static Pressure (mm H2 O) 0.02 0.04 0.06 0.08 0.1 01 2345 6 0.5 1.5 2.5 Air Flow (CFM) Static Pressure (inch H2 O) Air Flow (CMM) Static Pressure (mm H2 O) CFM-4020V-070-255 0.02 0.04 0.06 0.08 0.1 0.12 01 .4 2.84 .2 5.67 0.5 1.5 2.5 Air Flow (CFM) Static Pressure (inch H2 O) Air Flow (CMM) Static Pressure (mm H2 O) 0.04 0.08 0.12 0.16 0.2 0246 8 00 .055 0.11 0.1650 .22 Air Flow (CFM) Static Pressure (inch H2 O) Air Flow (CMM) Static Pressure (mm H2 O) CFM-4020V-145-123 CFM-4020V-160-210CFM-4020V-160-165 Additional Resources: Product Page | 3D Model

CUI DEVICES | SERIES: CFM-40V | DESCRIPTION: DC AXIAL FAN date 08/12/2022 | page 6 of 11 cuidevices.com PERFORMANCE CURVES (CONTINUED) 0.06 0.12 0.18 0.24 0246 81 0 1.5 4.5 Air Flow (CFM) Static Pressure (inch H2 O) Air Flow (CMM) Static Pressure (mm H2 O) 0.05 0.1 0.15 0.2 0.25 0.3 0369 12 1.27 2.54 3.81 5.08 6.35 7.62 00 .085 0.17 0.2550 .34 Air Flow (CFM) Static Pressure (inch H2 O) Air Flow (CMM) Static Pressure (mm H2 O) CFM-4020V-170-255 0.04 0.08 0.12 0.16 0.2 0246 8 00 .055 0.11 0.165 0.22 Air Flow (CFM) Static Pressure (inch H2 O) Air Flow (CMM) Static Pressure (mm H2 O) 0.06 0.12 0.18 0.24 0 24681 0 1.5 4.5 Air Flow (CFM) Static Pressure (inch H2 O) Air Flow (CMM) Static Pressure (mm H2 O) CFM-4020V-180-275 CFM-4020V-270-255CFM-4020V-260-210 Additional Resources: Product Page | 3D Model

CUI DEVICES | SERIES: CFM-40V | DESCRIPTION: DC AXIAL FAN date 08/12/2022 | page 7 of 11 cuidevices.com PERFORMANCE CURVES (CONTINUED) 0.05 0.1 0.15 0.2 0.25 0.3 0369 12 1.27 2.54 3.81 5.08 6.35 7.62 00 .085 0.17 0.2550 .34 Air Flow (CFM) Static Pressure (inch H2 O) Air Flow (CMM) Static Pressure (mm H2 O) CFM-4020V-280-275 Additional Resources: Product Page | 3D Model

CUI DEVICES | SERIES: CFM-40V | DESCRIPTION: DC AXIAL FAN date 08/12/2022 | page 8 of 11 cuidevices.com MECHANICAL parameter conditions/description min typ max units motor 4 pole DC brushless bearing system omniCOOLTM direction of rotation counter-clockwise viewed from front of fan blade dimensions CFM-4010V models: 40 x 40 x 10 CFM-4020V models: 40 x 40 x 20 mm mm material PBT (UL94V-0) weight CFM-4010V models CFM-4020V models 15.6 g g MECHANICAL DRAWINGS CFM-4010V WIRE CONNECTIONS Wire Color Function Red +Vin Black -Vin White1 RD Signal Yellow1 Tach Signal MOUNTING SCREW (Pan Head) Screw Type Size Standard Torque Machine Screw M4 JIS B1111-1974 3~4 kgf-cm Self-tapping Screw M5 JIS B1122 Type 2 6~8 kgf-cm units: mm wire: UL 1007 , 26 AWG CFM-4020V WIRE CONNECTIONS Wire Color Function Red +Vin Black -Vin White1 RD Signal Yellow1 Tach Signal Notes: 1. Wires only present on versions with output signals. Additional Resources: Product Page | 3D Model

CUI DEVICES | SERIES: CFM-40V | DESCRIPTION: DC AXIAL FAN date 08/12/2022 | page 9 of 11 cuidevices.com APPLICATION NOTES Figure 1: Auto Start Protection Auto Restart Protection When the fan motor is locked by an external force, the device will temporarily turn off electrical power to the motor and restart automatically when the locked rotor condition is released. Tachometer Signal (Yellow Wire) The tachometer signal is for detecting the rotational speed of the fan motor. The output will be a square wave when fan is operating and logical high (Vcc) when fan motor is locked (See Figures 4~5 below). The relationship between RPM & output pulses from the signal wire is as follows.

1 RPM = 2 Pulses

1 Pulse

1 RPM

t VL Vcc Figure 5: Tachometer Output Circuit DC Fan Red (+) Yellow Black (-) Customer Circuit Vcc Ic RL Vcc ≤ max input voltage Ic ≤ 4 mA RL ≥ Vcc/Ic VL ≤ 0.5 V Vsig Figure 4: Tachometer Output Waveform Rotation Detector Signal (White Wire) The rotation detector signal is used to detect if the fan motor is operating or stopped. The output will be logical low (VL) when fan is operating and be logical high (Vcc) when fan motor is locked. (See Figures 2~3 below). Figure 2: Rotation Detector Output Waveform Figure 3: Rotation Detector Output Circuit Run Locked Vsig t VL Vcc DC Fan Red (+) White Black (-) Customer Circuit Vcc Ic RL Vcc ≤ max input voltage Ic ≤ 4 mA RL ≥ Vcc/Ic VL ≤ 0.5 V Vsig Run Input Current t Locked Additional Resources: Product Page | 3D Model

CUI DEVICES | SERIES: CFM-40V | DESCRIPTION: DC AXIAL FAN date 08/12/2022 | page 10 of 11 cuidevices.com SAFETY CONSIDERATIONS 1. Do not use or operate this fan in excess of the limitations set forth in this specification. CUI is not responsible for the non-performance of this fan and/or any damages resulting from its use, if it is not used or operated in accordance with the specifications. 2. CUI recommends adding a protection circuit to the product or application in which this fan is installed, such as a thermo-fuse, or current fuse or thermo-protector. The failure to use such a device may result in smoke, fire, electric shock by insulation degradation in cases of motor lead short circuit, overload, or over voltage, and/or other failure. 3. CUI recommends installing a protection device to the product or application in which this fan is installed if there is a possibility of reverse connection between Vdc (+) and GND (-). The failue to install such a device may result in smoke, fire, and/or destruction, although these conditions may not manifest immediately. 4. This fan mush be installed and used in compliance with all applicable safety standards and regulations. 5. Use proper care when handling and/or installing this fan. Improper handling of installation of this fan may cause damage that could result in unsafe conditions. 6. Use proper care during installation and/or wiring. Failure to use proper care may cause damage to certain components of the fan including, but not limited to, the coil and lead wires, which could result in smoke and/or fire. 7. Do not use power or ground PWM to control the fan speed. If the fan speed needs to be adjusted, please contact CUI to customize the product design for your application. 8. For critical or extreme environments, including non-stop operation, please contact CUI and we will gladly provide assistance with your product selection to ensure an appropriate cooling product for your application. 9. When building your device, please examine thouroughly any variation of EMC, temperature rise, life data, quality, etc. of this product by shock/drop/vibration testing, etc. If there are any problems or accidents in connection with this product, it should be mutually discussed and examined. 10. Use proper care when handling these fans. Components such as fan holders or bearings may be damaged, if touched with fingers or other objects. Additionally, static electricity (ESD) may damage internal circuits of the fan. 11. Do not operate these fans in proximity to hazardous materials such as organic silicon, cyanogens, formalin, phenol, or corrosive gas environments including, but not limited to, H2S, SO2, NO2, or Cl2. 12. CUI recommends that you protect these fans from exposure to outside elements such as dust, condensation, humidity, or insects. Exposure of this fan to such elements may affect its performance and my cause safety hazards. CUI does not warrant against damage to the product caused by outside elements. 13. The fans must be installed properly and securely. Improper mounting may cause harsh resonance, vibration, and noise. 14. Do not store these fans in an environment with high humidity. These fans must be stored in accordance with the specified storage temperature. 15. CUI reserves the right to use components from multiple sources at its discretion. The use of components from other sources will not affect the specifications as described herein. 16. The life expectancy of these fans has not been evaluated for use in combination with any end application. Therefore, the life expectancy that relate to these fans are only for reference. Additional Resources: Product Page | 3D Model

CUI DEVICES | SERIES: CFM-40V | DESCRIPTION: DC AXIAL FAN date 08/12/2022 | page 11 of 11 CUI Devices offers a one (1) year limited warranty. Complete warranty information is listed on our website. CUI Devices reserves the right to make changes to the product at any time without notice. Information provided by CUI Devices is believed to be accurate and reliable. However, no responsibility is assumed by CUI Devices for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI Devices products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. cuidevices.com rev. description date 1.0 initial release 07 /21/2017 1.01 brand update 02/07 /2020 1.02 logo, datasheet style update 08/12/2022 The revision history provided is for informational purposes only and is believed to be accurate.

REVISION HISTORY

Additional Resources: Product Page | 3D Model