CEST1-C2 PANDUIT | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 8

Technical content

Panduit Cable Entry Systems complement our already broad and innovative control panel and on-machine solution that safely organizes, connects and protects electrical systems. The Cable Entry Systems offer a safe, organized method to transition cable and hoses through enclosures and electrical equipment, providing strain relief while maintaining IP/NEMA ingress sealing ratings. Traditional cable glands or cord grips require several time-consuming installation steps and considerable space on the enclosure; the Panduit offering simplifies the installation and can manage numerous cables in a very dense space. These design benefits provide up to 80% installation time savings dramatically increasing productivity and freeing up installers for other activities. The high-density hole configurations provide up to 80% space savings which is critical for machine applications that require several cables with limited space on the equipment. The extra hole locations in the same dense design allow for future cabling moves, adds, and changes. While cable glands or cord grips typically only handle unterminated cables, the Panduit system handles both unterminated and terminated cables for increased installation productivity. For more information about the Cable Entry Systems visit www.panduit.com/cable-entry-systems . FEATURE BENEFIT Round and rectangular solutions available Up to 80% labor savings and 80% space savings when multiple cables are required to pass into same enclosure. One hole / punch can accommodate up to 12 terminated cables and up to 140 unterminated cables. Accommodates terminated and un-terminated cables Prevents re-termination of cables in order to pass through openings Selection of IP ratings to accommodate customer requirements Meets multiple IP/NEMA ingress sealing ratings to accommodate a variety of applications that lets the user determine the most suitable solution for their requirements. Compatible with standard punch tools The circular and rectangular designs are compatible with industry standard electrical cutout punches to ease installation. Imperial dimensions physically molded into components Provides easy reference for customers who standardize on imperial dimensions Strain relief Grommets and sealing membranes prevent cables from over-bending at cable entry points

For cutout dimensions, scan the QR code or visit www.panduit.com/cable-entry-system-drawings Part Number IP/NEMA Rating Total Number of Openings Number of Grommets and Size Required Overall Dimensions Std. Pkg. Qty. Std. Ctn. Qty.Small Medium Large Length Width Installed Height In mm In mm In mm CEST1-C2 54/Type 1 and 12 2 — 2 — 3.98 101.1 2.28 57.9 0.59 15.0 1 50 CEST1-D3 3 — 3 — 4.76 120.9 CEST1-B4 4 4 — — 2.91 73.9 CEST1-E4 4 — 4 — 5.83 148.1 CEST1-C5 5 4 1 — 3.98 101.1CEST1-C6 6 6 — — CEST1-D7 7 6 1 — 4.76 120.9CEST1-D8 8 8 — — CEST1-E8 8 6 2 — 5.83 148.1CEST1-E9 9 8 1 — CEST1-E12 12 12 — — CEST2-C2 65/Type 1, 12, and 4X (indoor use only) 2 — 2 — 3.98 101.1 0.71 18.0 CEST2-D2 2 — — 2 4.76 120.9CEST2-D3 3 — 3 — CEST2-E3 3 — 1 2 5.83 148.1 CEST2-B4 4 4 — — 2.91 73.9 CEST2-E4 4 — 4 — 5.83 148.1 CEST2-C5 5 4 1 — 3.98 101.1 CEST2-A6 6 6 — — 5.83 148.1 1.5 38.1 CEST2-C6 6 6 — — 3.98 101.1 2.28 57.9 CEST2-D7 7 6 1 — 4.76 120.9CEST2-D8 8 8 — — CEST2-E8 8 6 2 — 5.83 148.1CEST2-E9 9 8 1 — CEST2-E12 12 12 — — Cable Entry System Frames for Terminated Cables - Rectangular

  • Requires the use of CEG grommets to achieve sealing properties (see page 4) — Small Grommets accommodate 0.08" – 0.47" cable diameters — Medium Grommets accommodate 0.47" – 0.87" cable diameters — Large Grommets accommodate 0.87" – 1.18" cable diameters
  • Incorporates integrated strain relief
  • Cable grommets available for ASI cables
  • Requires four (4) user supplied 10-32 screws and nuts for mounting
  • IP54 (NEMA Type 1 and 12) and IP65 (NEMA Type 1, 12, and 4X indoor use only) (with suitable grommets and cables)
  • Manufactured from polypropylene and TPE materials
  • Flammability: UL94V-0
  • Temperature rating: -22 °F – 212 °F (-30 °C – 100 °C) Cable Entry Systems CEST2 Family

Cable Entry System Frames for Terminated Cables - Round

  • Requires the use of CEG grommets to achieve sealing properties (see page 4) — Small Grommets accommodate 0.08" – 0.47" cable diameters — Medium Grommets accommodate 0.47" – 0.87" cable diameters — Large Grommets accommodate 0.87" – 1.18" cable diameters
  • Split locknut included
  • Cable grommets available for ASI cables
  • IP65 (NEMA Type 1 and 12)
  • Manufactured from polyamide 6 materials
  • Flammability: UL94V-0
  • Temperature rating: -22 °F – 212 °F (-30 °C – 100 °C)
  • Installs into a 2" (50.5mm) round hole
  • Requires the use of CEG grommets to achieve sealing properties (see page 4) — Small Grommets accommodate 0.08" – 0.47" cable diameters
  • Incorporates integrated strain relief
  • Requires four (4) user supplied 10-32 screws and nuts for mounting
  • IP65 (NEMA Type 1, 12, and 4X indoor use only)
  • Manufactured from polypropylene and TPE materials
  • Flammability: UL94V-0
  • Temperature rating: -22 °F – 212 °F (-30 °C – 100 °C) Part Number Total Number of Openings Number of Grommets and Size Required Overall Dimensions Std. Pkg. Qty. Std. Ctn. Qty.Small Medium Large Diameter Installed Height in mm in mm CEST2-RL251 1 0 1.57 39.9 0.73 18.5 5 50 CEST2-RL321 1.97 50.0 0.71 18.0 CEST2-RL401 2.44 62.0 CEST2-RL501 0 1 62.0 0.87 22.1 Part Number Total Number of Openings Number of Grommets and Size Required Overall Dimensions Std. Pkg. Qty. Std. Ctn. Qty.Small Medium Large Length Width Installed Height in mm in mm in mm For cutout dimensions, scan the QR code or visit www.panduit.com/cable-entry-system-drawings Cable Entry Systems

Grommets for Cable Entry System Frames for Terminated Cables

  • Place grommets around cables and insert into Cable Entry System Frames for Terminated Cables (see pages 2-3)
  • Three sizes allow cables from 0.08" up to 1.18" diameter to route into control panels
  • Cable grommets available for ASI cables
  • Use cable tie part number PLT2S-C0 to secure cable within grommet
  • Manufactured from TPE materials
  • Flammability: UL94V-0
  • Temperature rating: -22 °F – 212 °F (-30 °C – 100 °C) Part Number Compatibility for Frame Opening Number of Opening for Cables Cable Diameter Std. Pkg. Qty. Std. Ctn. Qty.In mm CEG-02X1 Small 12 1200 CEG-03X1 0.12 - 0.16 3.0 - 4.1 CEG-04X1 0.16 - 0.20 4.1 - 5.1 CEG-05X1 0.20 - 0.24 5.1 - 6.1 CEG-06X1 0.24 - 0.28 6.1 - 7.1 CEG-07X1 0.28 - 0.31 7.1 - 7.9 CEG-08X1 0.31 - 0.35 7.9 - 8.9 CEG-09X1 0.35 - 0.39 8.9 - 9.9 CEG-10X1 0.39 - 0.43 9.9 - 10.9 CEG-11X1 0.43 - 0.47 10.9 - 11.9 CEG-12X1 Medium 4 300 CEG-13X1 0.51 - 0.55 13.0 - 14.0 CEG-14X1 0.55 - 0.59 14.0 - 15.0 CEG-15X1 0.59 - 0.63 15.0 - 16.0 CEG-16X1 0.63 - 0.67 16.0 - 17.0 CEG-17X1 0.67 - 0.71 17.0 - 18.0 CEG-18X1 0.71 - 0.75 18.0 - 19.1 CEG-19X1 0.75 - 0.79 19.1 - 20.1 CEG-20X1 0.79 - 0.83 20.1 - 21.1 CEG-21X1 0.83 - 0.87 21.1 - 22.1 CEG-22X1 Large CEG-23X1 0.91 - 0.94 23.1 - 23.9 CEG-24X1 0.94 - 0.98 23.9 - 24.9 CEG-25X1 0.98 - 1.02 24.9 - 25.9 CEG-26X1 1.02 - 1.06 25.9 - 26.9 CEG-27X1 1.06 - 1.10 26.9 - 27.9 CEG-28X1 1.10 - 1.14 27.9 - 29.0 CEG-29X1 1.14 - 1.18 29.0 - 30.0 CEG-02X2 Small 12 1200 CEG-02X4 4 CEG-03X2 2 0.12 - 0.16 3.0 - 4.1CEG-03X4 4 CEG-04X2 2 0.16 - 0.20 4.1 - 5.1CEG-04X4 4 CEG-05X2 Medium 4 300 CEG-05X4 4 CEG-06X2 2 0.24 - 0.28 6.1 - 7.1CEG-06X4 4 CEG-07X2 2 0.28 - 0.31 7.1 - 7.9CEG-07X4 4 CEG-08X2 2 0.31 - 0.35 7.9 - 8.9CEG-08X4 4 CEG—X1 CEG—X4 Part Number Compatibility for Frame Opening Description Std. Pkg. Qty. Std. Ctn. Qty. CEGASIX2 Medium Cable bushing to accommodate two ASI bus cables 4 300 CEGAM Medium Adapter to allow the use of small grommets in a medium hole in the frame 4 300 CEGBLS Small Blank / Filler Grommet 12 1200 CEGBLM Medium Blank / Filler Grommet 4 300 CEGBLL Large Blank / Filler Grommet 4 300 CEGASIX2 CEGAM CEGBLS CEG—X2 Cable Entry Systems

Cable Entry System for Un-Terminated Cables - Rectangular

  • Engineered cable entry system offering a high degree of strain relief
  • For snap-in fastening and/or screwing in place with four (4) user supplied 10-32 screws and nuts
  • Snap-in at plate thickness of 0.06" to 0.08" thick
  • Identification area suitable for label part number T024X000FJM-BK printed with the Panduit MP75, MP100, MP200, or MP300 printer.
  • Ports feature an innovative polymer membrane that gives a high quality fit around cables and a high degree of strain relief.
  • IP65 (NEMA Type 1 and 12)
  • Manufactured from polyamide 6.6 and TPU/EPDM materials
  • Flammability: UL94V-0
  • Temperature rating: -22 °F – 212 °F (-30 °C – 100 °C) Part Number Total Number of Openings Number of Openings Size of Openings Overall Dimensions Std. Pkg. Qty. Std. Ctn. Qty. Length Width Installed Height In mm In mm In mm In mm CESU2-E10 10 5 0.35 - 0.55 8.9 - 14.0 2 0.55 - 0.79 14.0 - 20.1 CESU2-E11 11 4 0.12 - 0.26 3.0 - 6.6 3 0.55 - 0.79 14.0 - 20.1 CESU2-E12 12 12 0.31 - 0.47 7.9 - 11.9 CESU2-E13 13 4 0.35 - 0.55 8.9 - 14.0 1 0.55 - 0.79 14.0 - 20.1 CESU2-E14 14 4 0.38 - 0.63 9.7 - 16.0 CESU2-E17 17 17 0.20 - 0.36 5.1 - 9.1 CESU2-E17A 17 11 0.12 - 0.26 3.0 - 6.6 5 0.31 - 0.49 7.9 - 12.4 CESU2-E22 22 16 0.12 - 0.26 3.0 - 6.6 2 0.31 - 0.49 7.9 - 12.4 CESU2-E23 23 23 0.16 - 0.32 4.1 - 8.1 CESU2-E29 29 29 0.12 - 0.26 3.0 - 6.6 For cutout dimensions, scan the QR code or visit www.panduit.com/cable-entry-system-drawings Cable Entry Systems

Cable Entry Membrane Plate for Un-Terminated Cables - Rectangular

  • Membrane plate cable entry system offering good strain relief
  • Requires four (4) user supplied 10-32 screws and nuts for mounting
  • IP66 (NEMA Type 12 and 4X indoor use only)
  • Manufactured from polypropylene (frame) and TPE (seal)
  • Flammability: UL94V-0 Frame and UL94-HB Seal
  • Temperature rating: -22 °F – 158 °F (-30 °C – 70 °C) *Reference Greenlee website for appropriate punch tools to accommodate cutouts above Part Number Total Number of Openings Number of Openings Size of Openings Overall Dimensions Std. Pkg. Qty. Std. Ctn. Qty. Length Width Installed Height In mm In mm In mm In mm CESUM3-C14 14 14 0.20 - 0.35 5.00 - 9.00 4.1 103.0 2.4 61.0 0.59 15.0 5 50 CESUM3-C15 15 8 0.12 - 0.31 3.00 - 8.00 3 0.20 - 0.35 5.00 - 9.00 4 0.30 - 0.47 7.50 - 12.00 CESUM3-D10 10 10 0.30 - 0.47 7.50 - 12.00 4.8 123.0 CESUM3-D12 12 2 0.12 - 0.20 3.00 - 5.00 4 0.20 - 0.35 5.00 - 9.00 2 0.30 - 0.47 7.50 - 12.00 2 0.39 - 0.63 10.00 - 16.00 2 0.55 - 0.79 14.00 - 20.00 CESUM3-D17 17 17 0.20 - 0.35 5.00 - 9.00 CESUM3-D24 24 16 0.12 - 0.24 3.00 - 6.00 6 0.20 - 0.35 5.00 - 9.00 2 0.30 - 0.47 7.50 - 12.00 CESUM3-E14 14 14 0.30 - 0.47 7.50 - 12.00 5.87 149.1 CESUM3-E23 23 23 0.20 - 0.35 5.00 - 9.00 For cutout dimensions, scan the QR code or visit www.panduit.com/cable-entry-system-drawings Cable Entry Systems

Std. Pkg. Qty. Std. Ctn. Qty. Diameter Installed Height In mm In mm In mm CESU2-RL504 4 2.28 58.0 0.35 8.9 1 50 1 0.38 - 0.63 9.7 - 16.0 CESU2-RL506 6 CESU2-RL508 8 CESU2-RL5031 31 31 0.06 - 0.12 1.5 - 3.0 CESU2-RL638 8 2.80 71.0 2 0.38 - 0.63 9.7 - 16.0 CESU2-RL6313 13 CESU2-RL6319 19 19 0.12 - 0.20 3.0 - 5.1 CESU2-RL6346 46 46 0.06 - 0.12 1.5 - 3.0 Part Number Total Number of Openings Number of Openings Size of Openings Overall Dimensions Std. Pkg. Qty. Std. Ctn. Qty. Diameter Installed Height In mm In mm In mm CESUM3-R406 6 1.9 48.5 0.33 8.5 5 50 1 0.30 - 0.47 7.5 - 12.0 CESUM3-R407 7 Cable Entry System for Un-Terminated Cables - Round

  • Engineered cable entry system offering a high degree of strain relief
  • For snap-in fastening or securing in place with a locknut
  • Snaps into panel thickness of 0.06" to 0.08"
  • Locknut included is used for securement but is not UL approved
  • IP65 (NEMA 1)
  • Manufactured from polyamide 6.6 and NBR/EPDM materials
  • Temperature rating: -22 °F – 194 °F (-30 °C – 90 °C)
  • Membrane plate cable entry system offering good strain relief
  • For snap-in fastening or screwing in place with a locknut (not included)
  • Snaps into panel thickness of 0.06" to 0.08"
  • IP65 (NEMA 12 and 4X - indoor/horizontal mount only)
  • Manufactured from polyamide 6.6 and NBR/EPDM materials
  • Temperature Rating: -22 °F – 194 °F (-30 °C – 90 °C) For cutout dimensions, scan the QR code or visit www.panduit.com/cable-entry-system-drawings Cable Entry Systems

Cable Entry System Plates for Un-Terminated Cables - Rectangular - Metal

  • Aluminum and stainless steel plates are best for high density cabling and the most demanding environments
  • Stainless steel version is suitable for application in the food and chemical areas
  • Engineered cable entry system offering a high degree of strain relief
  • IP65 (NEMA Type 1 and 12)
  • Stainless steel products include integrated fasteners. Aluminum products require four (4) user supplied 10-32 screws and nuts for mounting.
  • Seals are manufactured from NBR / EDPM materials
  • Temperature rating: -22 °F - 194 °F (-30 °C - 90 °C) Part Number Material Total Number of Openings Number of Openings Size of Openings Overall Dimensions Std. Pkg. Qty. Std. Ctn. Qty. Length Width Installed Height In mm In mm In mm In mm CESU2-F25-AL+ Aluminum 5.67 144.0 3.54 89.9 0.22 5.6 1 5 16 0.16 - 0.31 4.1 - 7.9 CESU2-F47-AL 47 14 0.14 - 0.26 3.6 - 6.6 8.7 221.0 28 0.18 - 0.33 4.6 - 8.4 4 0.28 - 0.43 7.1 - 10.9 1 0.43 - 0.63 10.9 - 16.0 CESU2-F47-SS* Stainless Steel 14 0.14 - 0.26 3.6 - 6.6 0.20 5.0 28 0.18 - 0.33 4.6 - 8.4 4 0.28 - 0.43 7.1 - 10.9 1 0.43 - 0.63 10.9 - 16.0 CESU2-H140-SS*+ 140 16 0.14 - 0.24 3.6 - 6.1 64 0.18 - 0.33 4.6 - 8.4 36 0.24 - 0.39 6.1 - 9.9 4 0.31 - 0.47 7.9 - 11.9 8 0.35 - 0.55 8.9 - 14.0 8 0.55 - 0.71 14.0 - 18.0 4 0.71 - 0.98 18.0 - 24.9 *Integrated threaded bolts mean that no screws are visible from the outside +UL Recognized only (UR) For cutout dimensions, scan the QR code or visit www.panduit.com/cable-entry-system-drawings WORLDWIDE SUBSIDIARIES AND SALES OFFICES PANDUIT CANADA Markham, Ontario cs-cdn@panduit.com Phone: 800.777.3300 PANDUIT EUROPE LTD. London, UK cs-emea@panduit.com Phone: 44.20.8601.7200 PANDUIT JAPAN Tokyo, Japan cs-japan@panduit.com Phone: 81.3.6863.6000 PANDUIT SINGAPORE PTE. LTD. Republic of Singapore cs-ap@panduit.com Phone: 65.6305.7575 PANDUIT AUSTRALIA PTY. LTD. Victoria, Australia cs-aus@panduit.com Phone: 61.3.9794.9020 PANDUIT LATIN AMERICA Guadalajara, Mexico cs-la@panduit.com Phone: 52.33.3777.6000 Contact Customer Service by email: cs@panduit.com or by phone: 800.777.3300 Visit us at www.panduit.com For more information For a copy of Panduit product warranties, log on to www.panduit.com/warranty ©2022 Panduit Corp. ALL RIGHTS RESERVED. Printed in the U.S.A. FRCB3-SA-ENG Cable Entry Systems