Datasheet-CEB100W

Document overview

  • PDF pages: 11

Technical content

Features

⚫ Efficiency Up to 93.5% ⚫ Fixed Switching Frequency ⚫ Regulated Outputs ⚫ Remote On/Off ⚫ Fully Protected (OTP/OCP/OVP/UVLO) ⚫ 3000Vdc I/O Isolation ⚫ Operating Case Temperature -40 to +105℃ ⚫ Eighth Brick Size Meet Industrial Standard 2.45”x1.05”x0.5” ⚫ CB Test Certificate IEC 62368-1 ⚫ UL 62368-1 (Basic Insulation) Approval ⚫ Shock & Vibration MIL-STD-810F/EN 61373 Compliant ⚫ Fire & Smoke EN 45545-2 Compliant ⚫ 5000m Operating Altitude MODEL NUMBER INPUT VOLTAGE OUTPUT VOLTAGE OUTPUT CURRENT INPUT CURRENT % EFF. CAPACITOR LOAD MAX. MIN. MAX. NO LOAD FULL LOAD (3) (2) CEB100W-24S05 9-40 VDC 5 VDC 0 mA 20 A 125 mA 4735 mA 92 91 20000uF CEB100W-24S12 9-40 VDC 12 VDC 0 mA 8.3 A 125 mA 4663 mA 92.5 90.5 8300μF CEB100W-24S24 9-40 VDC 24 VDC 0 mA 4.2 A 125 mA 4667 mA 90.5 90 4200uF CEB100W-24S48 9-40 VDC 48 VDC 0 mA 2.1 A 125 mA 4625 mA 90.5 90.5 1000uF CEB100W-24S54 9-40 VDC 54 VDC 0 mA 1.85 A 125 mA 4574 mA 91 91 1000uF CEB100W-48S05 16.5-74 VDC 5 VDC 0 mA 20 A 80 mA 2252 mA 93.5 92.5 20000uF CEB100W-48S12 16.5-74 VDC 12 VDC 0 mA 8.3 A 80 mA 2255 mA 93 92 8300μF CEB100W-48S24 16.5-74 VDC 24 VDC 0 mA 4.2 A 80 mA 2320 mA 91 90.5 4200uF CEB100W-48S48 16.5-74 VDC 48 VDC 0 mA 2.1 A 80 mA 2308 mA 91 91 1000uF CEB100W-48S54 16.5-74 VDC 54 VDC 0 mA 1.85 A 80 mA 2287 mA 91.5 91 1000uF NOTE: 1. Nominal Input Voltage 24, 48VDC. 2. Measured at Nominal Input Voltage. 3. Measured at 12VDC for 24Vin, 24VDC for 48Vin. PART NUMBER Series Nominal Input Voltage Number of Outputs Nominal Output Voltage Remote On/Off Logic Mounting Inserts Operating Case Temp. Range CEB100W- II O XX L -Y (Option) -Z (Option) CEB100W 24:24 VDC 48:48 VDC S: Single 05: 5.0VDC None: Positive -F: Flanged Baseplate with M2.5 mounting insert None: -40~105℃ 12: 12VDC 24: 24 VDC 48: 48VDC N: Negative 54: 54VDC Part Number Example: CEB100W-48S12N: Eighth Brick, 100W, 4:1 16.5-74Vdc Input, Single 12Vdc Output, Negative Logic, -40~105℃ Operating Case Temp. Range

www.cincon.com 2 REVISION: V10 CEB100W Series TECHNICAL SPECIFICATIONS (All specifications are typical at nominal input, full load at 25℃ unless otherwise noted.) ABSOLUTE MAXIMUM RATINGS PARAMETER NOTES and CONDITIONS Device Min. Typ. Max. Units Input Voltage Continuous 24Vin -0.3 40 Vdc 48Vin -0.3 75 Input Surge Voltage 100ms max. 24Vin 50 Vdc 48Vin 100 Operating Ambient Temperature At the center part of case plate (with derating) All -40 105 ℃ Maximum Case Temperature All 110 ℃ Storage Temperature All -55 125 ℃ INPUT CHARACTERISTICS PARAMETER NOTES and CONDITIONS Device Min. Typ. Max. Units Operating Input Voltage 24Vin 9 24 40 Vdc 48Vin 16.5 48 75 Input Under Voltage Lockout Turn-On Voltage Threshold 24Vin 8 8.5 8.8 Vdc 48Vin 15.7 16 16.3 Turn-Off Voltage Threshold 24Vin 7.7 8 8.3 Vdc 48Vin 14.7 15 15.3 Lockout Hysteresis Voltage 24Vin 0.6 Vdc 48Vin 1 Maximum Input Current Vin=9V, Full load. 24Vin 13.5 A Vin=16.5V, Full load 48Vin 6.8 No-Load Input Current Vin=24, 48V, Io=0A See Model Number Table mA Input Filter Pi filter All Inrush Current (I2t) As per ETS300 132-2 All 0.1 A2s Input Reflected Ripple Current P-P thru 12uH inductor, 5Hz to 20MHz All 30 mA OUTPUT CHARACTERISTICS PARAMETER NOTES and CONDITIONS Device Min. Typ. Max. Units Voltage Set Point Accuracy Vin=24, 48V, Full load, Tc=25℃ All -1.0 +1.0 % Output Voltage Regulation Load Regulation Full load to no load All ±0.2 % Line Regulation Vin=High line to low line, full load All ±0.2 % Temperature Coefficient Tc=-40℃ to 105℃ All ±0.02 %/℃ Output Voltage Ripple and Noise (5Hz to 20MHz bandwidth) Peak-to-Peak Full load, 10uF polymer and 1.0uF ceramic capacitors 5Vo 100 mV 12Vo 150 24Vo 240 48Vo 480 54Vo 480 RMS 5Vo 40 12Vo 60 24Vo 100 48Vo 200 54Vo 200

www.cincon.com 3 REVISION: V10 CEB100W Series PARAMETER NOTES and CONDITIONS Device Min. Typ. Max. Units Output Current Range Vin= 9 to 36V, 18 to 75V See Model Number Table A Over Current Protection Hiccup mode. Auto recovery All 110 125 160 % Over Voltage Protection Limited voltage 5Vo 112 130 12Vo 122 135 24Vo 122 135 48Vo 112 130 54Vo 106 115 Short Circuit Protection All Continuous, Auto Recovery External Load Capacitance Full load (resistive) See Model Number Table uF Output Voltage Trim Range Po≦max. rated power, Io ≦ Io_max. 5Vo -20 +10 12Vo -20 +20 24Vo -20 +20 48Vo -20 +10 54Vo -20 +5 EFFICIENCY PARAMETER NOTES and CONDITIONS Device Min. Typ. Max. Units 100% Load Vin=24V, 48V See Model Number Table % DYNAMIC CHARACTERISTICS PARAMETER NOTES and CONDITIONS Device Min. Typ. Max. Units Output Voltage Current Transient Error Band 75% to 100% of I o_max step load change di/dt=0.1A/us (within 1% Vout nominal) All ±5 % Recovery Time All 250 us Turn-On Delay and Rise Time Full load (constant resistive load) Turn-On Delay Time, From On/Off Control Von/off to 10%Vo_set, Remote on All 30 ms Turn-On Delay Time, From Input Vin_min to 10%Vo_set, Power up All 30 ms Output Voltage Rise Time 10%Vo_set to 90%Vo_set All 30 ms ISOLATION CHARACTERISTICS PARAMETER NOTES and CONDITIONS Device Min. Typ. Max. Units Isolation Voltage (100% factory Hi-Pot tested @2sec.)

1 Minute; input to output

Vdc 1 Minute; input to case 1600

1 Minute; output to case 1600

Isolation Resistance Input to output All 1 GΩ Isolation Capacitance Input to output All 1000 pF Input to case NC Output to case NC FEATURE CHARACTERISTICS PARAMETER NOTES and CONDITIONS Device Min. Typ. Max. Units Switching Frequency Pulse width modulation (PWM), fixed All 270 300 330 KHz On/Off Control, Positive Remote On/Off Logic, Refer to -Vin Pin Logic Low (Module Off) Von/off at Ion/off=1.0mA All 0 1.2 V Logic High (Module On) Von/off at Ion/off=0.0uA, Pin open=On All 3.5 75 V On/Off Control, Negative Remote On/Off Logic, Refer to -Vin Pin Logic High (Module Off) Von/off at Ion/off=0.0uA, Pin open=Off All 3.5 75 V Logic Low (Module On) Von/off at Ion/off=1.0mA All 0 1.2 V On/Off Current (for Both Remote On/Off Logic) Ion/off at Von/off=0V All 0.3 1 mA Leakage Current (for Both Remote On/Off Logic) Logic high, Von/off=15V All 30 uA

www.cincon.com 4 REVISION: V10 CEB100W Series PARAMETER NOTES and CONDITIONS Device Min. Typ. Max. Units Off Converter Input Current Shutdown input idle current All 5 10 mA Over Temperature Shutdown Temperature at the center part of case, non- latching All 110 ℃ Over Temperature Recovery All 100 ℃ GENERAL SPECIFICATIONS PARAMETER NOTES and CONDITIONS Device Min. Typ. Max. Units MTBF Io=100% of Io_max.; MIL-HDBK - 217F_Notice 1, GB, 25℃ 05Vo 1000 K hours 12Vo 24Vo 980 48Vo 54Vo Weight All 49 grams Case Material Plastic, DAP, UL 94V-0 Base plate Material FR4 Potting Material UL 94V-0 Pin Material Base: Copper Plating: Nickel with Matte Tin Shock/Vibration MIL-STD-810F/EN 61373 Compliant Humidity 95% RH max. Non condensing Altitude 5000m Operating altitude, 12000m Transport altitude Thermal Shock MIL-STD-810F Fire & Smoke EN 45545-2 Compliant EMC SPECIFICATIONS (External components required, please refer to application note.) EMI Meets EN 55032, External Input Filter Class A ESD EN 61000-4-2 Level 3: Air ±8kV, Contact ±6kV , external components required Perf. Criteria A Radiated Immunity EN 61000-4-3 Level 3: 80~1000MHz, 20V/m , external components required Perf. Criteria A Fast Transient EN 61000-4-4 Level 3: On power input port, ±2kV, external components required Perf. Criteria A Surge EN 61000-4-5 Level 4: Line to earth, ±4kV, Line to line, ±2kV , external components required Perf. Criteria A Conducted Immunity EN 61000-4-6 Level 3: 0.15~80MHz, 10V Perf. Criteria A Packaging Information Link Packaging Information

www.cincon.com 5 REVISION: V10 CEB100W Series Immunity to Environmental Conditions. Phenomenon EN 50155; 2017 Reference Clause(s) Reference Standard Test Conditions Result Low Temperature Start-up test 13.4.4 EN 60068-2-1 Class OT6 Temperature: -40℃ Duration: 2 hrs Pass Dry Heat Test 13.4.5 EN 60068-2-2 Class OT6 & ST2 Temperature: 85℃ Duration: 6 hrs Extended temperature: 100℃ Extended Duration: 10min Pass Low Temperature Storage Test 13.4.6 EN 60068-2-1 Temperature: -40℃ Duration: 16 hrs Pass Cyclic Damp Heat Test 13.4.7 EN 60068-2-30 Temperature: 25℃ - 55℃ Humidity: 90% RH Duration: 48 hrs Pass Random Vibration Test 13.4.11 EN 61373 Temperature: 25℃±10℃ Humidity: 50% ±25% RH Frequency range: 5 ~ 150 Hz Vertical: 1.01 𝑚 𝑠⁄ 2 Transverse: 0.450 𝑚 𝑠⁄ 2 Longitudinal: 0.700 𝑚 𝑠⁄ 2 Duration: 10 min / axis Pass Simulated Long Life Test at Increased Random Vibration Levels

13.4.11 EN 61373

Temperature: 25℃±10℃ Humidity: 50% ±25% RH Frequency range: 5 ~ 150 Hz Vertical: 5.72 𝑚 𝑠⁄ 2 Transverse: 2.55 m s⁄ 2 Longitudinal: 3.96 𝑚 𝑠⁄ 2 Duration: 5 hrs / axis Pass Shock Test 13.4.11 EN 61373 Temperature: 25℃±10℃ Humidity: 50% ±25% RH Frequency range: 5 ~ 150 Hz ±Vertical: 30 m s⁄ 2 ±Transverse: 30 𝑚 𝑠⁄ 2 ±Longitudinal: 50 𝑚 𝑠⁄ 2 Duration: 30ms x18 (Each axis 3 shocks) Pass EN 45545-2 Fire & Smoke Test Conditions. Item Standard Hazard Level R22 Oxygen Index Test EN 45545-2: 2013+A1:2015 EN ISO 4589-2: 2017 HL1, HL2, HL3 Smoke Density Test EN 45545-2: 2013+A1:2015 EN ISO 5659-2: 2017 HL1, HL2, HL3 Smoke Toxicity Test EN 45545-2: 2013+A1:2015 NF X70-100-1&2: 2006 HL1, HL2, HL3 R23 Oxygen Index Test EN 45545-2: 2013+A1:2015 EN ISO 4589-2: 2017 HL1, HL2, HL3 Smoke Density Test EN 45545-2: 2013+A1:2015 EN ISO 5659-2: 2017 HL1, HL2, HL3 Smoke Toxicity Test EN 45545-2: 2013+A1:2015 NF X70-100-1&2: 2006 HL1, HL2, HL3 R24 Oxygen Index Test EN45545-2: 2013 EN ISO 4589-2 HL1, HL2, HL3 R25 Glow - Wire Test EN 45545-2: 2020+A1:2023 EN 60695-2-11:2014 HL1, HL2, HL3 R26 Vertical Flame Test EN 45545-2: 2013+A1:2015 EN 60695-11-10: 2013 HL1, HL2, HL3

www.cincon.com 6 REVISION: V10 CEB100W Series CHARACTERISTIC CURVE Power Derating Curve 100 110 0 10 20 30 40 50 60 70 80 90 100 110 Output Power (%) Ambient Temperature (℃) CEB100W-24S05, 54 Derating Curve without Heatsink (Vin=24V) Natural 100 ft./min. 200 ft./min. 300 ft./min. 400 ft./min. 100 110 0 10 20 30 40 50 60 70 80 90 100 110 Output Power (%) Ambient Temperature (℃) CEB100W-24S05, 54 Derating Curve with Heatsink (Vin=24V) Natural 100 ft./min. 200 ft./min. 300 ft./min. 400 ft./min. 100 110 0 10 20 30 40 50 60 70 80 90 100 110 Output Power (%) Ambient Temperature (℃) CEB100W-24S12, 48 Derating Curve without Heatsink (Vin=24V) Natural 100 ft./min. 200 ft./min. 300 ft./min. 400 ft./min. 100 110 0 10 20 30 40 50 60 70 80 90 100 110 Output Power (%) Ambient Temperature (℃) CEB100W-24S12, 48 Derating Curve with Heatsink (Vin=24V) Natural 100 ft./min. 200 ft./min. 300 ft./min. 400 ft./min. 100 110 0 10 20 30 40 50 60 70 80 90 100 110 Output Power (%) Ambient Temperature (℃) CEB100W-24S24 Derating Curve without Heatsink (Vin=24V) Natural 100 ft./min. 200 ft./min. 300 ft./min. 400 ft./min. 100 110 0 10 20 30 40 50 60 70 80 90 100 110 Output Power (%) Ambient Temperature (℃) CEB100W-24S24 Derating Curve with Heatsink (Vin=24V) Natural 100 ft./min. 200 ft./min. 300 ft./min. 400 ft./min.

www.cincon.com 7 REVISION: V10 CEB100W Series 100 110 0 10 20 30 40 50 60 70 80 90 100 110 Output Power (%) Ambient Temperature (℃) CEB100W-48S05 Derating Curve without Heatsink (Vin=48V) Natural 100 ft./min. 200 ft./min. 300 ft./min. 400 ft./min. 100 110 0 10 20 30 40 50 60 70 80 90 100 110 Output Power (%) Ambient Temperature (℃) CEB100W-48S05 Derating Curve with Heatsink (Vin=48V) Natural 100 ft./min. 200 ft./min. 300 ft./min. 400 ft./min. 100 110 0 10 20 30 40 50 60 70 80 90 100 110 Output Power (%) Ambient Temperature (℃) CEB100W-48S12 Derating Curve without Heatsink (Vin=48V) Natural 100 ft./min. 200 ft./min. 300 ft./min. 400 ft./min. 100 110 0 10 20 30 40 50 60 70 80 90 100 110 Output Power (%) Ambient Temperature (℃) CEB100W-48S12 Derating Curve with Heatsink (Vin=48V) Natural 100 ft./min. 200 ft./min. 300 ft./min. 400 ft./min. 100 110 0 10 20 30 40 50 60 70 80 90 100 110 Output Power (%) Ambient Temperature (℃) CEB100W-48S24 Derating Curve without Heatsink (Vin=48V) Natural 100 ft./min. 200 ft./min. 300 ft./min. 400 ft./min. 100 110 0 10 20 30 40 50 60 70 80 90 100 110 Output Power (%) Ambient Temperature (℃) CEB100W-48S24 Derating Curve with Heatsink (Vin=48V) Natural 100 ft./min. 200 ft./min. 300 ft./min. 400 ft./min. 100 110 0 10 20 30 40 50 60 70 80 90 100 110 Output Power (%) Ambient Temperature (℃) CEB100W-48S48, 54 Derating Curve without Heatsink (Vin=48V) Natural 100 ft./min. 200 ft./min. 300 ft./min. 400 ft./min. 100 110 0 10 20 30 40 50 60 70 80 90 100 110 Output Power (%) Ambient Temperature (℃) CEB100W-48S48, 54 Derating Curve with Heatsink (Vin=48V) Natural 100 ft./min. 200 ft./min. 300 ft./min. 400 ft./min.

www.cincon.com 8 REVISION: V10 CEB100W Series Performance Data 60% 70% 80% 90% 100% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% Efficiency (%) Current Load (%) CEB100W-24S05 Eff Vs Io @25 Deg. C 12V 24V 40V Power Dissipation (W) Output Power (%) CEB100W-24S05 Pd Vs Po @25 Deg. C 12V 24V 40V 60% 70% 80% 90% 100% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% Efficiency (%) Current Load (%) CEB100W-24S12 Eff Vs Io @25 Deg. C 12V 24V 40V Power Dissipation (W) Output Power (%) CEB100W-24S12 Pd Vs Po @25 Deg. C 12V 24V 40V 60% 70% 80% 90% 100% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% Efficiency (%) Current Load (%) CEB100W-24S24 Eff Vs Io @25 Deg. C 12V 24V 40V Power Dissipation (W) Output Power (%) CEB100W-24S24 Pd Vs Po @25 Deg. C 12V 24V 40V 60% 70% 80% 90% 100% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% Efficiency (%) Current Load (%) CEB100W-24S48 Eff Vs Io @25 Deg. C 12V 24V 40V Power Dissipation (W) Output Power (%) CEB100W-24S48 Pd Vs Po @25 Deg. C 12V 24V 40V

www.cincon.com 9 REVISION: V10 CEB100W Series 60% 70% 80% 90% 100% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% Efficiency (%) Current Load (%) CEB100W-24S54 Eff Vs Io @25 Deg. C 12V 24V 40V Power Dissipation (W) Output Power (%) CEB100W-24S54 Pd Vs Po @25 Deg. C 12V 24V 36V 60% 70% 80% 90% 100% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% Efficiency (%) Current Load (%) CEB100W-48S05 Eff Vs Io @25 Deg. C 16.5V 24V 48V 75V Power Dissipation (W) Output Power (%) CEB100W-48S05 Pd Vs Po @25 Deg. C 16.5V 24V 48V 75V 50% 60% 70% 80% 90% 100% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% Efficiency (%) Current Load (%) CEB100W-48S12 Eff Vs Io @25 Deg. C 16.5V 24V 48V 75V Power Dissipation (W) Output Power (%) CEB100W-48S12 Pd Vs Po @25 Deg. C 16.5V 24V 48V 75V 60% 70% 80% 90% 100% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% Efficiency (%) Current Load (%) CEB100W-48S24 Eff Vs Io @25 Deg. C 16.5V 24V 48V 75V Power Dissipation (W) Output Power (%) CEB100W-48S24 Pd Vs Po @25 Deg. C 16.5V 24V 48V 75V

www.cincon.com 10 REVISION: V10 CEB100W Series 60% 70% 80% 90% 100% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% Efficiency (%) Current Load (%) CEB100W-48S48 Eff Vs Io @25 Deg. C 16.5V 24V 48V 75V Power Dissipation (W) Output Power (%) CEB100W-48S48 Pd Vs Po @25 Deg. C 16.5V 24V 48V 75V 60% 70% 80% 90% 100% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% Efficiency (%) Current Load (%) CEB100W-48S54 Eff Vs Io @25 Deg. C 16.5V 24V 48V 75V Power Dissipation (W) Output Power (%) CEB100W-48S54 Pd Vs Po @25 Deg. C 16.5 24V 48V 75V

sales@cincon.com www.cincon.com

11 REVISION: V10

-F: Flanged Baseplate