CDM-A108 CAMPBELL | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 2

Technical content

' =) SCIENTIFIC WHEN MEASUREMENTS MATTER Overview The CDM-A108 is an analog input module that allows you to easily expand your Campbell Scientific data logging system. The CDM-A108 features a 24-bit, analog-to-digital converter and a low-noise, analog front-end to provide you with superior analog measurements. This module also supports Benefits and Features ) Ability to make simultaneous measurements ) CANbus 2.0A/2.0B capable; contact Campbell Scientific for details Technical Description The CDM-A108 offers 24-bit sigma-delta Adc with 16 user programmable notch frequencies from 30,000 Hz to 2.5 Hz, Specifications -NOTE- Additional specifications are listed in the COM-A108 and CDM-A116 brochure. Power Requirements 96 to 32 Vdc voltage Mounting Standard 1-in. grid (DIN rail mounting available) For comprehensive details, visit: www.campbellsci.eu/cdm-a108 o Fet= (o= CDM-A10 8-Channel 5 V Analog Input Module 24-Bit Resolution Greatly increases sensor capacity period average measurements and includes both current and voltage excitation channels. The CDM-A108 has eight differential inputs and two excitation channels. It provides both a 12V and a switched 12V port for powering your peripherals and two switched 5 V ports for peripheral control. ) Increases the number of analog channels in a data logger system ) Supports period average measurements ) Includes both current and voltage excitation channels including 50 and 60 Hz. Previous generations of data loggers could notch out 50 or 60 Hz. Estimated Accuracy +(0.08% of reading + offset) -55°10 +85°C +(0.06% of reading + offset) -40°t0 +70°C +(0.04% of reading + offset) 0° 10 40°C Number of Channels 8 differential or 16 single-ended

-40°to +70°C (standard) -55°10 +85°C (extended) 3.0 kHz (using fast [100 ps] input setting) 30kHz +5000 mV, 1000 mV, and +200 mv Traditional period averaging on analog input channels For data logger connection. Baud rate selectable from 50 kbps to 1 Mbps. (Allowable cable length varies depending on baud rate, number of nodes, cable quality, and noise environment, but can be as long as 700 m under proper conditions) USB 2.0 full speed connection available for attaching to a PC. (Portiis used to configure the module and download updates via our Device Configuration Utility) One year against defects in materials and workmanship 203x127x51cm(8x5x2in) 08kg (175 1b) Typical Current Drain Sleep <1 mA Active 1 Hz Scan 2 mA (estimated) Assumes one single-ended measurement with the first notch frequency (fy;) at 30 kHz Active 20 Hz Scan 20 mA Assumes one single-ended measurement with the first notch frequency (fyy;) at 30 kHz Voltage/Current Excitation Outputs Voltage Excitation +5V (@ 50mA) Current Excitation +25mA (£5 V compliance voltage) Number of Voltage/Current 2 Excitation Outputs General Purpose Outputs Number of SW5V Outputs 2 SW5V Output Resistance 30 Q) Number of SW12V Outputs 1 Typical Limit of SW12V 200mA Outputs Minimum Limit of SW12V 180 mA Outputs Number of 12V Qutputs 1 Typical Limit of 12V Outputs200 mA Minimum Limit of 12/ 180 mA Outputs a For comprehensive details, visit: www.campbellsci.eu/cdm-a108 CAMPBELL 80 Hathern Road, Shepshed, LE12 9GX UK | +(0)1509 828888 | sale@campbellsci.couk | www.campbellsci.eu SCIENTIFIC AUSTRALIA | BRAZIL | CANADA | CHINA | COSTA RICA | FRANCE | GERMANY | INDIA | SOUTH AFRICA | SPAIN | THAILAND | UK | USA ©2020 Campbell Scientific, Ltd. | 07/29/2020