・All specifications are subject to change without notice. CC 3 - 05 05 S F -E ■ Features

  • Mounting area halved compared to existing products
  • Nonuse of tantalum capacitor or aluminum electro - lytic capacitor
  • Remote On/Off function incorporated in all series of products
  • High accuracy of ±3% in output voltage (10W of lower single output)
  • 5-side metal-shielded low noise design
  • Lightweight design with no resin filled up
  • Supports DIP insertion, SMD mounting and SIP verti- cal insertion (3W products)
  • Approved by UL60950-1, CSA C22.2 No.60950-1 (C-UL), and EN60950-1 (NEMKO) CC-E ■ Product Line up Insulation type DC-DC converter ■ Applications XBSSBOUZ ■ Model-naming method Shape Symbol for number of outputs S: Single output, D: Dual outputs Nominal output voltage 03: 3.3V, 05: 5V, 12: 12V Nominal input voltage 05: 5V, 12: 12V, 24: 24V, 48: 48V Maximum output power 10: 10W, 15: 15W, 25: 25W Representing series name by combination with "-E"at the end Output power Input voltage Model name (output voltage: 3.3V) Model name (output voltage: 5V) Model name (output voltage: 12V/15V) Model name (output voltage: ±12V/±15V) Output current DIP type SMD type SIP type Output current DIP type SMD type SIP type Output current DIP type SMD type SIP type Output current DIP type SMD type SIP type 1.5W 10W 12V 2.5A CC10-1203SF-E CC10-1203SR-E - 2A CC10-1205SF-E CC10-1205SR-E - 1A (0.8A) CC10-1212SF-E CC10-1212SR-E - 0.45A (0.36A) CC10-1212DF-E CC10-1212DR-E - 24V 2.5A CC10-2403SF-E CC10-2403SR-E - 2A CC10-2405SF-E CC10-2405SR-E - 1A (0.8A) CC10-2412SF-E CC10-2412SR-E - 0.45A (0.36A) CC10-2412DF-E CC10-2412DR-E - 48V 2.5A CC10-4803SF-E CC10-4803SR-E - 2A CC10-4805SF-E CC10-4805SR-E - 1A (0.8A) CC10-4812SF-E CC10-4812SR-E - 0.45A (0.36A) CC10-4812DF-E CC10-4812DR-E - 15W 24V 4.5A CC15-2403SF-E CC15-2403SR-E - 3A CC15-2405SF-E CC15-2405SR-E - - - - - - - - - 25W 24V 7.5A CC25-2403SF-E CC25-2403SR-E - 5A CC25-2405SF-E CC25-2405SR-E - - - - - - - - - F: Horizontally-mounted DIP type R: Horizontally-mounted SMD type FS Vertically-mounted SIP type $4"$/P -PX7PMUBHF%JSFDUJWF &MFDUSJDBM "QQMJBODF BOE.BUFSJBM4BGFUZ-BX *OQVU 7PMUBHF 7"$ %&/"/ #VJMUUPNFFU ҩɹྍɹଌ 'ɹ" ൒ಋମ ͦͷଞ ͦͷଞ LT ίϯϐϡʔλ ௨ɹ৴ 'ɹ" ൒ಋମ ͦͷଞQI QGB ILB IXT BMQIB EMQ GQT ϑΥʔϚοτ ίϯϐϡʔλ ௨ɹ৴ 'ɹ" ൒ಋମ ͦͷଞ ίϯϐϡʔλ ௨ɹ৴ ҩɹྍɹଌ 'ɹ" ൒ಋମ ͦͷଞ ίϯϐϡʔλ ௨ɹ৴ ҩɹྍɹଌ 'ɹ" ൒ಋମ ͦͷଞ ίϯϐϡʔλ ௨ɹ৴ ҩɹྍɹଌ 'ɹ" ൒ಋମ ͦͷଞ ίϯϐϡʔλ ௨ɹ৴ ҩɹྍɹଌ 'ɹ" ൒ಋମ ͦͷଞ This means that, in conformity with EU Directive 2002/95/EC, lead, cadmium, mercury, hexavalent chromium, and specific bromine-based flame retar - dants, PBB and PBDE, have not been used, except for exempted applications. ■ Conformity to RoHS Directive $4"$/P -PX7PMUBHF%JSFDUJWF &MFDUSJDBM "QQMJBODF BOE.BUFSJBM4BGFUZ-BX *OQVU 7PMUBHF 7"$ %&/"/ #VJMUUPNFFU 00-0/2008042/etl_cc_e

・All specifications are subject to change without notice. CC1R5-E Specifications MODELITEMS/UNITS CC1R5-0503Sx-E CC1R5-0505Sx-E CC1R5-0512Sx-E CC1R5-0512Dx-E Input Nominal Voltage V DC5.0 Voltage Range V DC4.5-9.0 Efficiency (typ) (*1) % 71 77 80 79 Current (typ) (*1) A 0.372 0.390 0.375 0.380 Output Nominal Voltage VDC 3.3 5 12 15 ± 12 ± 15 Maximum Power (*2) W 1.32 1.5 Maximum Line Regulation (Within input voltage range) mV 20 40 80 Maximum Load Regulation (0-100% load) (*3) mV 40 100 600 Temperature Coefficient (Ambient temperature–40°C to +50°C) 80mV 200mV 300mV Max Power Total Regulation (max) (*4) % ± 3 ± 5 Maximum Ripple & Noise (typ/max) (*5) mVp-p 40/120 30/120 Function Over Current Protection (*6) Available Over Voltage Protection Not available Remote ON/OFF Control Available Environment Operating Temperature ℃ -40 to +85 Storage Temperature ℃ -40 to +85 Operating Humidity % RH 5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.) Storage Humidity % RH 5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.) Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each Shock 980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation Isolation Withstand Voltage Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute) Isolation Resistance Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50MΩ min Standards Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO) Mechanical Weight (typ) g 3.2 Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names. Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately. Note: For 12V/ ± 12V models, output power can be set to 15V/ ± 15V by connecting the output adjustment terminal TRM to -Vout. Note: For ± 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open. (*1) With nominal input voltage, maximum output current, and Ta=25°C. (*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed. (*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal). (*4) Output voltage includes input change, load change (balanced load), and temperature change. (*5) In 50MHz, Ta=25°C. (*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30 seconds. MODELITEMS/UNITS CC1R5-1203Sx-E CC1R5-1205Sx-E CC1R5-1212Sx-E CC1R5-1212Dx-E Input Nominal Voltage V DC12 Voltage Range V DC9.0-18 Efficiency (typ) (*1) % 73 78 82 81 Current (typ) (*1) A 0.151 0.160 0.152 0.154 Output Nominal Voltage VDC 3.3 5 12 15 ± 12 ± 15 Maximum Power (*2) W 1.32 1.5 Maximum Line Regulation (Within input voltage range) mV 20 40 80 Maximum Load Regulation (0-100% load) (*3) mV 40 100 600 Temperature Coefficient (Ambient temperature–40°C to +50°C) 80mV 200mV 300mV Max Power Total Regulation (max) (*4) % ± 3 ± 5 Maximum Ripple & Noise (typ/max) (*5) mVp-p 40/120 30/120 Function Over Current Protection (*6) Available Over Voltage Protection Not available Remote ON/OFF Control Available Environment Operating Temperature ℃ -40 to +85 Storage Temperature ℃ -40 to +85 Operating Humidity % RH 5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.) Storage Humidity % RH 5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.) Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each Shock 980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation Isolation Withstand Voltage Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute) Isolation Resistance Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50MΩ min Standards Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO) Mechanical Weight (typ) g 3.2 Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names. Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately. Note: For 12V/ ± 12V models, output power can be set to 15V/ ± 15V by connecting the output adjustment terminal TRM to -Vout. Note: For ± 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open. (*1) With nominal input voltage, maximum output current, and Ta=25°C. (*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed. (*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal). (*4) Output voltage includes input change, load change (balanced load), and temperature change. (*5) In 50MHz, Ta=25°C. (*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30 seconds. CC1R5-E

・All specifications are subject to change without notice. MODELITEMS/UNITS CC1R5-2403Sx-E CC1R5-2405Sx-E CC1R5-2412Sx-E CC1R5-2412Dx-E Input Nominal Voltage V DC24 Voltage Range V DC18-36 Efficiency (typ) (*1) % 72 77 81 79 Current (typ) (*1) A 0.076 0.081 0.077 0.079 Output Nominal Voltage VDC 3.3 5 12 15 ± 12 ± 15 Maximum Power (*2) W 1.32 1.5 Maximum Line Regulation (Within input voltage range) mV 20 40 80 Maximum Load Regulation (0-100% load) (*3) mV 40 100 600 Temperature Coefficient (Ambient temperature–40°C to +50°C) 80mV 200mV 300mV Max Power Total Regulation (max) (*4) % ± 3 ± 5 Maximum Ripple & Noise (typ/max) (*5) mVp-p 40/120 30/120 Function Over Current Protection (*6) Available Over Voltage Protection Not available Remote ON/OFF Control Available Environment Operating Temperature ℃ -40 to +85 Storage Temperature ℃ -40 to +85 Operating Humidity % RH 5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.) Storage Humidity % RH 5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.) Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each Shock 980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation Isolation Withstand Voltage Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute) Isolation Resistance Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50MΩ min Standards Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO) Mechanical Weight (typ) g 3.2 Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names. Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately. Note: For 12V/ ± 12V models, output power can be set to 15V/ ± 15V by connecting the output adjustment terminal TRM to -Vout. Note: For ± 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open. (*1) With nominal input voltage, maximum output current, and Ta=25°C. (*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed. (*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal). (*4) Output voltage includes input change, load change (balanced load), and temperature change. (*5) In 50MHz, Ta=25°C. (*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30 seconds. MODELITEMS/UNITS CC1R5-4803Sx-E CC1R5-4805Sx-E CC1R5-4812Sx-E CC1R5-4812Dx-E Input Nominal Voltage V DC48 Voltage Range V DC36-76 Efficiency (typ) (*1) % 70 76 80 79 Current (typ) (*1) A 0.039 0.041 0.039 0.040 Output Nominal Voltage VDC 3.3 5 12 15 ± 12 ± 15 Maximum Power (*2) W 1.32 1.5 Maximum Line Regulation (Within input voltage range) mV 20 40 80 Maximum Load Regulation (0-100% load) (*3) mV 40 100 600 Temperature Coefficient (Ambient temperature–40°C to +50°C) 80mV 200mV 300mV Max Power Total Regulation (max) (*4) % ± 3 ± 5 Maximum Ripple & Noise (typ/max) (*5) mVp-p 40/120 30/120 Function Over Current Protection (*6) Available Over Voltage Protection Not available Remote ON/OFF Control Available Environment Operating Temperature ℃ -40 to +85 Storage Temperature ℃ -40 to +85 Operating Humidity % RH 5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.) Storage Humidity % RH 5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.) Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each Shock 980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation Isolation Withstand Voltage Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute) Isolation Resistance Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50MΩ min Standards Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO) Mechanical Weight (typ) g 3.2 Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names. Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately. Note: For 12V/ ± 12V models, output power can be set to 15V/ ± 15V by connecting the output adjustment terminal TRM to -Vout. Note: For ± 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open. (*1) With nominal input voltage, maximum output current, and Ta=25°C. (*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed. (*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal). (*4) Output voltage includes input change, load change (balanced load), and temperature change. (*5) In 50MHz, Ta=25°C. (*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30 seconds. CC1R5-E

・All specifications are subject to change without notice. Derating Curve 3FDPNNFOEFENFBTVSFNFOUTGPS NPVOUJOHCPBSE 3FDPNNFOEFENFBTVSFNFOUTGPS NPVOUJOHCPBSE $POOFDUJPOEJBHSBN E-xDxxxx-5R1CCE-xSxxxx-5R1CC 16.6±0.2 12.71.905 1.905 t=0.3 2.54 7.62 16.51 12.7 4.0 2.545.082.54 a b 7-0.3×0.6 b a 2.7 1.0 2.7 0.53.50.5 a b 2.545.082.54 14.605 7.62 10.16 13.08 2.92 16.51 2-ø1.5 (land diameter ø2.5) 7-ø1.0 (land diameter ø2.0) Unit: mm Allowable tolerance is ±0.5 if not specified separately. 16.6±0.2 t=0.3 8.8max. 16.51 4.0 $PQMBOBSJUZPSMPXFS 19.81 1.81.8(3.22)(3.22) 2.54 7.62 2.545.082.54 67-0.3×0.6 2.545.082.54 7.62 10.16 (13.38) (3.22) 22.0 3.2 3.215.6 1.2 Unit: mm Allowable tolerance is ±0.5 if not specified separately. 1 7

4 N C

–Vout +Vout TRM RC +Vin –Vin 5FSNJOBMDPOOFDUJPOT No.1 +Vin No.2 RC No.3 –Vin No.4 NC No.5 –Vout No.6 TRM No.7 +Vout 1 7 COM –Vout +Vout TRM RC +Vin –Vin 5FSNJOBMDPOOFDUJPOT No.1 +Vin No.2 RC No.3 –Vin No.4 –Vout No.5 Common out No.6 TRM No.7 +Vout 4IBQF%JNFOTJPOT 4IBQF%JNFOTJPOT -PBE-PBE -PBE 0VUFSTIBQFPG QSPEVDU 0VUFSTIBQFPG QSPEVDU Outline Drawing CC1R5-xxxxxF-E (DIP type) CC1R5-xxxxxR-E (SMD type) CC1R5-E a b "NCJFOUUFNQFSBUVSF ˃$ 0VUQVUQPXFS a:0.5m/s(100LFM) b:1m/s(200LFM) /BUVSBMBJSDPPMJOH -40 -20ɹ 0ɹ 20ɹ 40ɹ60ɹ80ɹ100 100 0VUQVUQPXFSEFSBUJOHCZBNCJFOUUFNQFSBUVSF DPNNPOTQFDJGJDBUJPO

・All specifications are subject to change without notice. CC3-E Specifications MODELITEMS/UNITS CC3-0503Sx-E CC3-0505Sx-E CC3-0512Sx-E CC3-0512Dx-E Input Nominal Voltage V DC5.0 Voltage Range V DC4.5-9.0 Efficiency (typ) (*1) % 73 77 82 81 Current (typ) (*1) A 0.723 0.779 0.732 0.741 Output Nominal Voltage VDC 3.3 5 12 15 ± 12 ± 15 Maximum Power (*2) 2.64 3 Maximum Line Regulation(Within input voltage range) mV 20 40 80 Maximum Load Regulation (0-100% load) (*3) mV 40 100 600 Temperature Coefficient (Ambient temperature -40℃ to +50℃ ) 80mV 200mV 300mV Max Power Total Regulation (max) (*4) % ± 3 ± 5 Maximum Ripple & Noise (typ/max) (*5) mVp-p 40/120 30/120 Function Over Current Protection (*6) Available Over Voltage Protection Not available Remote ON/OFF Control Available Environment Operating Temperature ℃ -40 to +85 Storage Temperature ℃ -40 to +85 Operating Humidity % RH 5-95 (the conditions of maximum 38℃ in wet bulb temperature and non-condensation should be ensured.) Storage Humidity % RH 5-95 (the conditions of maximum 38℃ in wet bulb temperature and non-condensation should be ensured.) Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, X/Y/Z 3 directions, 2h for each Shock 980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation Isolation Withstand Voltage Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute) Isolation Resistance Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50MΩ min Standards Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO) Mechanical Weight (typ) g 4.5 Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names. Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately. Note: For 12V/ ± 12V models, output power can be set to 15V/ ± 15V by connecting the output adjustment terminal TRM to -Vout. Note: For ± 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open. (*1) With nominal input voltage, maximum output current, and Ta=25°C. (*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed. (*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal). (*4) Output voltage includes input change, load change (balanced load), and temperature change. (*5) In 50MHz, Ta=25°C. (*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30 seconds. MODELITEMS/UNITS CC3-1203Sx-E CC3-1205Sx-E CC3-1212Sx-E CC3-1212Dx-E Input Nominal Voltage V DC12 Voltage Range V DC9.0-18 Efficiency (typ) (*1) % 74 79 82 81 Current (typ) (*1) A 0.297 0.316 0.305 0.309 Output Nominal Voltage VDC 3.3 5 12 15 ± 12 ± 15 Maximum Power (*2) W 2.64 3 Maximum Line Regulation(Within input voltage range) mV 20 40 80 Maximum Load Regulation (0-100% load) (*3) mV 40 100 600 Temperature Coefficient (Ambient temperature -40℃ to +50℃ ) 80mV 200mV 300mV Max Power Total Regulation (max) (*4) % ± 3 ± 5 Maximum Ripple & Noise (typ/max) (*5) mVp-p 40/120 30/120 Function Over Current Protection (*6) Available Over Voltage Protection Not available Remote ON/OFF Control Available Environment Operating Temperature ℃ -40 to +85 Storage Temperature ℃ -40 to +85 Operating Humidity % RH 5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.) Storage Humidity % RH 5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.) Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, X/Y/Z 3 directions, 2h for each Shock 980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation Isolation Withstand Voltage Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute) Isolation Resistance Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50MΩ min Standards Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO) Mechanical Weight (typ) g 4.5 Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names. Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately. Note: For 12V/ ± 12V models, output power can be set to 15V/ ± 15V by connecting the output adjustment terminal TRM to -Vout. Note: For ± 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open. (*1) With nominal input voltage, maximum output current, and Ta=25°C. (*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed. (*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal). (*4) Output voltage includes input change, load change (balanced load), and temperature change. (*5) In 50MHz, Ta=25°C. (*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30 seconds. CC3-E(DIP/SMD)

・All specifications are subject to change without notice. MODELITEMS/UNITS CC3-2403Sx-E CC3-2405Sx-E CC3-2412Sx-E CC3-2412Dx-E Input Nominal Voltage V DC24 Voltage Range V DC18-36 Efficiency (typ) (*1) % 73 78 82 81 Current (typ) (*1) A 0.151 0.160 0.152 0.154 Output Nominal Voltage VDC 3.3 5 12 15 ± 12 ± 15 Maximum Power (*2) W 2.64 3 Maximum Line Regulation(Within input voltage range) mV 20 40 80 Maximum Load Regulation (0-100% load) (*3) mV 40 100 600 Temperature Coefficient (Ambient temperature -40℃ to +50℃ ) 80mV 200mV 300mV Max Power Total Regulation (max) (*4) % ± 3 ± 5 Maximum Ripple & Noise (typ/max) (*5) mVp-p 40/120 30/120 Function Over Current Protection (*6) Available Over Voltage Protection Not available Remote ON/OFF Control Available Environment Operating Temperature ℃ -40 to +85 Storage Temperature ℃ -40 to +85 Operating Humidity % RH 5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.) Storage Humidity % RH 5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.) Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, X/Y/Z 3 directions, 2h for each Shock 980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation Isolation Withstand Voltage Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute) Isolation Resistance Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50MΩ min Standards Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO) Mechanical Weight (typ) g 4.5 Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names. Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately. Note: For 12V/ ± 12V models, output power can be set to 15V/ ± 15V by connecting the output adjustment terminal TRM to -Vout. Note: For ± 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open. (*1) With nominal input voltage, maximum output current, and Ta=25°C. (*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed. (*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal). (*4) Output voltage includes input change, load change (balanced load), and temperature change. (*5) In 50MHz, Ta=25°C. (*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30 seconds. MODELITEMS/UNITS CC3-4803Sx-E CC3-4805Sx-E CC3-4812Sx-E CC3-4812Dx-E Input Nominal Voltage V DC48 Voltage Range V DC36-76 Efficiency (typ) (*1) % 73 79 81 80 Current (typ) (*1) A 0.075 0.079 0.077 0.078 Output Nominal Voltage VDC 3.3 5 12 15 ± 12 ± 15 Maximum Power (*2) W 2.64 3 Maximum Line Regulation(Within input voltage range) mV 20 40 80 Maximum Load Regulation (0-100% load) (*3) mV 40 100 600 Temperature Coefficient (Ambient temperature -40℃ to +50℃ ) 80mV 200mV 300mV Max Power Total Regulation (max) (*4) % ± 3 ± 5 Maximum Ripple & Noise (typ/max) (*5) mVp-p 40/120 30/120 Function Over Current Protection (*6) Available Over Voltage Protection Not available Remote ON/OFF Control Available Environment Operating Temperature ℃ -40 to +85 Storage Temperature ℃ -40 to +85 Operating Humidity % RH 5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.) Storage Humidity % RH 5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.) Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, X/Y/Z 3 directions, 2h for each Shock 980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation Isolation Withstand Voltage Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute) Isolation Resistance Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50MΩ min Standards Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO) Mechanical Weight (typ) g 4.5 Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names. Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately. Note: For 12V/ ± 12V models, output power can be set to 15V/ ± 15V by connecting the output adjustment terminal TRM to -Vout. Note: For ± 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open. (*1) With nominal input voltage, maximum output current, and Ta=25°C. (*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed. (*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal). (*4) Output voltage includes input change, load change (balanced load), and temperature change. (*5) In 50MHz, Ta=25°C. (*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30 seconds. CC3-E(DIP/SMD)

・All specifications are subject to change without notice. a b "NCJFOUUFNQFSBUVSF ˃$ 0VUQVUQPXFS a:0.5m/s(100LFM) b:1m/s(200LFM) /BUVSBMBJSDPPMJOH -40 -20ɹ 0ɹ 20ɹ 40ɹ60ɹ80ɹ100 100 0VUQVUQPXFSEFSBUJOHCZBNCJFOUUFNQFSBUVSF DPNNPOTQFDJGJDBUJPO 3FDPNNFOEFENFBTVSFNFOUTGPSNPVOUJOHCPBSE 3FDPNNFOEFENFBTVSFNFOUTGPSNPVOUJOHCPBSE $POOFDUJPOEJBHSBN E-xDxxxx-3CCE-xSxxxx-3CC 17.78 2.745.245.2 (3.22)(3.22) 2.54 7.62 2.545.082.54 a b 7-0.3×0.6 ab 1.0 2.7 0.53.50.5 a b 8.5max.3.5 22.86 17.78 16.6±0.2 t=0.3 4.0 2.545.082.54 20.32 7.62 10.16 13.08 2.92 22.86 2-ø1.5 (land diameter ø2.5) 7-ø1.0 (land diameter ø2.0) Unit: mm Allowable tolerance is ±0.5 if not specified separately. 26.16 8.18.1 (3.22)(3.22) 2.54 7.62 2.545.082.54 7-0.3×0.6 8.8max. 22.86 16.6±0.2 t=0.3 4.0 $PQMBOBSJUZPSMPXFS Unit: mm Allowable tolerance is ±0.5 if not specified separately. 2.545.082.54 7.62 10.16 (13.38) (3.22) 28.4 3.2 22.0 3.2 1.2 1 7 –Vout +Vout TRM RC +Vin –Vin 5FSNJOBMDPOOFDUJPOT No.1 +Vin No.2 RC No.3 –Vin No.4 NC No.5 –Vout No.6 TRM No.7 +Vout 1 7 COM –Vout +Vout TRM RC +Vin –Vin 5FSNJOBMDPOOFDUJPOT No.1 +Vin No.2 RC No.3 –Vin No.4 –Vout No.5 Common out No.6 TRM No.7 +Vout 4IBQF%JNFOTJPOT 4IBQF%JNFOTJPOT Outer shape of product Outer shape of product LoadLoad Load Outline Drawing CC3-xxxxxF-E (DIP type) CC3-xxxxxR-E (SMD type) CC3-E(DIP/SMD) Derating Curve

・All specifications are subject to change without notice. CC3-E Specifications MODELITEMS/UNITS CC3-0503SS-E CC3-0505SS-E CC3-0512SS-E CC3-0512DS-E Input Nominal Voltage V DC5.0 Voltage Range V DC4.5-9.0 Efficiency (typ) (*1) % 73 77 82 81 Current (typ) (*1) A 0.723 0.779 0.732 0.741 Output Nominal Voltage VDC 3.3 5 12 15 ± 12 ± 15 Maximum Power (*2) W 2.64 3 Maximum Line Regulation (Within input voltage range) mV 20 40 80 Maximum Load Regulation (0-100% load) (*3) mV 40 100 600 Temperature Coefficient (Ambient temperature -40℃ to +50℃ ) 80mV 200mV 300mV Max Power Total Regulation (max) (*4) % ± 3 ± 5 Maximum Ripple & Noise (typ/max) (*5) mVp-p 40/120 30/120 Function Over Current Protection (*6) Available Over Voltage Protection Not available Remote ON/OFF Control Available Environment Operating Temperature ℃ -40 to +85 Storage Temperature ℃ -40 to +85 Operating Humidity % RH 5-95 (the conditions of maximum 38℃ in wet bulb temperature and non-condensation should be ensured.) Storage Humidity % RH 5-95 (the conditions of maximum 38℃ in wet bulb temperature and non-condensation should be ensured.) Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each Shock 980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation Isolation Withstand Voltage Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute) Isolation Resistance Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50MΩ min Standards Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO) Mechanical Weight (typ) g 7 Size (W x H x D) mm 27.8 x 17.9 x 9.2 Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately. Note: For 12V/ ± 12V models, output power can be set to 15V/ ± 15V by connecting the output adjustment terminal TRM to -Vout. Note: For ± 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open. (*1) With nominal input voltage, maximum output current, and Ta=25°C. (*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed. (*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal). (*4) Output voltage includes input change, load change (balanced load), and temperature change. (*5) In 50MHz, Ta=25°C. (*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30 seconds. MODELITEMS/UNITS CC3-1203SS-E CC3-1205SS-E CC3-1212SS-E CC3-1212DS-E Input Nominal Voltage V DC12 Voltage Range V DC9.0-18 Efficiency (typ) (*1) % 73 79 82 Current (typ) (*1) A 0.301 0.316 0.305 Output Nominal Voltage VDC 3.3 5 12 15 ± 12 ± 15 Maximum Power (*2) W 2.64 3 Maximum Line Regulation (Within input voltage range) mV 20 40 80 Maximum Load Regulation (0-100% load) (*3) mV 40 100 600 Temperature Coefficient (Ambient temperature -40℃ to +50℃ ) 80mV 200mV 300mV Max Power Total Regulation (max) (*4) % ± 3 ± 5 Maximum Ripple & Noise (typ/max) (*5) mVp-p 40/120 30/120 Function Over Current Protection (*6) Available Over Voltage Protection Not available Remote ON/OFF Control Available Environment Operating Temperature ℃ -40 to +85 Storage Temperature ℃ -40 to +85 Operating Humidity % RH 5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.) Storage Humidity % RH 5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.) Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each Shock 980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation Isolation Withstand Voltage Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute) Isolation Resistance Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50MΩ min Standards Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO) Mechanical Weight (typ) g 7 Size (W x H x D) mm 27.8 x 17.9 x 9.2 Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately. Note: For 12V/ ± 12V models, output power can be set to 15V/ ± 15V by connecting the output adjustment terminal TRM to -Vout. Note: For ± 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open. (*1) With nominal input voltage, maximum output current, and Ta=25°C. (*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed. (*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal). (*4) Output voltage includes input change, load change (balanced load), and temperature change. (*5) In 50MHz, Ta=25°C. (*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30 seconds. CC3-E(SIP)

・All specifications are subject to change without notice. MODELITEMS/UNITS CC3-2403SS-E CC3-2405SS-E CC3-2412SS-E CC3-2412DS-E Input Nominal Voltage V DC24 Voltage Range V DC18-36 Efficiency (typ) (*1) % 73 78 82 81 Current (typ) (*1) A 0.151 0.160 0.152 0.154 Output Nominal Voltage VDC 3.3 5 12 15 ± 12 ± 15 Maximum Power (*2) W 2.64 3 Maximum Line Regulation (Within input voltage range) mV 20 40 80 Maximum Load Regulation (0-100% load) (*3) mV 40 100 600 Temperature Coefficient (Ambient temperature -40℃ to +50℃ ) 80mV 200mV 300mV Max Power Total Regulation (max) (*4) % ± 3 ± 5 Maximum Ripple & Noise (typ/max) (*5) mVp-p 40/120 30/120 Function Over Current Protection (*6) Available Over Voltage Protection Not available Remote ON/OFF Control Available Environment Operating Temperature ℃ -40 to +85 Storage Temperature ℃ -40 to +85 Operating Humidity % RH 5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.) Storage Humidity % RH 5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.) Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each Shock 980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation Isolation Withstand Voltage Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute) Isolation Resistance Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50MΩ min Standards Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO) Mechanical Weight (typ) g 7 Size (W x H x D) mm 27.8 x 17.9 x 9.2 Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately. Note: For 12V/ ± 12V models, output power can be set to 15V/ ± 15V by connecting the output adjustment terminal TRM to -Vout. Note: For ± 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open. (*1) With nominal input voltage, maximum output current, and Ta=25°C. (*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed. (*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal). (*4) Output voltage includes input change, load change (balanced load), and temperature change. (*5) In 50MHz, Ta=25°C. (*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30 seconds. MODELITEMS/UNITS CC3-4803SS-E CC3-4805SS-E CC3-4812SS-E CC3-4812DS-E Input Nominal Voltage V DC48 Voltage Range V DC36-76 Efficiency (typ) (*1) % 73 79 82 Current (typ) (*1) A 0.075 0.079 0.076 Output Nominal Voltage VDC 3.3 5 12 15 ± 12 ± 15 Maximum Power (*2) W 2.64 3 Maximum Line Regulation (Within input voltage range) mV 20 40 80 Maximum Load Regulation (0-100% load) (*3) mV 40 100 600 Temperature Coefficient (Ambient temperature -40℃ to +50℃ ) 80mV 200mV 300mV Max Power Total Regulation (max) (*4) % ± 3 ± 5 Maximum Ripple & Noise (typ/max) (*5) mVp-p 40/120 30/120 Function Over Current Protection (*6) Available Over Voltage Protection Not available Remote ON/OFF Control Available Environment Operating Temperature ℃ -40 to +85 Storage Temperature ℃ -40 to +85 Operating Humidity % RH 5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.) Storage Humidity % RH 5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.) Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each Shock 980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation Isolation Withstand Voltage Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute) Isolation Resistance Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50MΩ min Standards Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO) Mechanical Weight (typ) g 7 Size (W x H x D) mm 27.8 x 17.9 x 9.2 Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately. Note: For 12V/ ± 12V models, output power can be set to 15V/ ± 15V by connecting the output adjustment terminal TRM to -Vout. Note: For ± 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open. (*1) With nominal input voltage, maximum output current, and Ta=25°C. (*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed. (*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal). (*4) Output voltage includes input change, load change (balanced load), and temperature change. (*5) In 50MHz, Ta=25°C. (*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30 seconds. CC3-E(SIP)

・All specifications are subject to change without notice. Outline Drawing CC3-xxxxxS-E (SIP type) CC3-E(SIP) E-SDxxxx-3CCE-SSxxxx-3CC

2.47 P P P P 2 P P P P P 6

3.5 (0.5) 4.1 (0.5) 17.9 17.78 5.01 2.47 22.86 1(t=0.3) a 0.5 P=2.54 9.2 9.2 27.8 a 1 2 3 4 5 7 8 9 10 SMD mounting space 17.78 2.47 22.86 2.47 27.8 P P P P 2P P=2.54 P P P 6.0 9.2 9-ø0.8 (land diameter ø2.0) 2-ø1.5 (land diameter ø2.5) Unit: mm Allowable tolerance is ±0.5 if not specified separately. 3FDPNNFOEFENFBTVSFNFOUTGPSNPVOUJOHCPBSE +Vin +Vout TRM RC –Vin +Vin –Vout 1 2 3 4 5 7 8 9 1 0 5FSNJOBMDPOOFDUJPOT No.1 +Vout No.2 NC No.3 NC No.4 –Vout No.5 TRM No.6 NC No.7 RC No.8 –Vin No.9 +Vin No.10 +Vin +Vin +Vout COM COM TRM RC –Vout 1 2 3 4 5 7 8 9 1 0 –Vin +Vin 5FSNJOBMDPOOFDUJPOT No.1 +Vout No.2 COM No.3 COM No.4 –Vout No.5 TRM No.6 NC No.7 RC No.8 –Vin No.9 +Vin No.10 +Vin 4IBQF%JNFOTJPOT $POOFDUJPOEJBHSBN Load Load Load a b "NCJFOUUFNQFSBUVSF ˃$ 0VUQVUQPXFS a:0.5m/s(100LFM) b:1m/s(200LFM) /BUVSBMBJSDPPMJOH -40 -20ɹ 0ɹ 20ɹ 40ɹ60ɹ80ɹ100 100 0VUQVUQPXFSEFSBUJOHCZBNCJFOUUFNQFSBUVSF DPNNPOTQFDJGJDBUJPO Derating Curve

・All specifications are subject to change without notice. CC6-E Specifications MODELITEMS/UNITS CC6-0503Sx-E CC6-0505Sx-E CC6-0512Sx-E CC6-0512Dx-E Input Nominal Voltage V DC5.0 Voltage Range V DC4.5-9.0 Efficiency (typ) (*1) % 76 79 82 Current (typ) (*1) A 1.042 1.266 1.463 Output Nominal Voltage VDC 3.3 5 12 15 ± 12 ± 15 Maximum Power (*2) W 3.96 5 6 Maximum Line Regulation(Within input voltage range) mV 20 40 80 Maximum Load Regulation (0-100% load) (*3) mV 40 100 600 Temperature Coefficient (Ambient temperature -40℃ to +50℃ ) 80mV 200mV 300mV Max Power Total Regulation (max) (*4) % ± 3 ± 5 Maximum Ripple & Noise (typ/max) (*5) mVp-p 40/120 30/120 Function Over Current Protection (*6) Available Over Voltage Protection Not available Remote ON/OFF Control Available Environment Operating Temperature ℃ -40 to +85 Storage Temperature ℃ -40 to +85 Operating Humidity % RH 5-95 (the conditions of maximum 38℃ in wet bulb temperature and non-condensation should be ensured.) Storage Humidity % RH 5-95 (the conditions of maximum 38℃ in wet bulb temperature and non-condensation should be ensured.) Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each Shock 980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation Isolation Withstand Voltage Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute) Isolation Resistance Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50MΩ min Standards Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO) Mechanical Weight (typ) g 5.8 Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names. Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately. Note: For 12V/ ± 12V models, output power can be set to 15V/ ± 15V by connecting the output adjustment terminal TRM to -Vout. Note: For ± 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open. (*1) With nominal input voltage, maximum output current, and Ta=25°C. (*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed. (*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal). (*4) Output voltage includes input change, load change (balanced load), and temperature change. (*5) In 50MHz, Ta=25°C. (*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30 seconds. MODELITEMS/UNITS CC6-1203Sx-E CC6-1205Sx-E CC6-1212Sx-E CC6-1212Dx-E Input Nominal Voltage V DC12 Voltage Range V DC9.0-18 Efficiency (typ) (*1) % 78 82 85 Current (typ) (*1) A 0.423 0.610 0.588 Output Nominal Voltage VDC 3.3 5 12 15 ± 12 ± 15 Maximum Power (*2) W 3.96 6 Maximum Line Regulation(Within input voltage range) mV 20 40 80 Maximum Load Regulation (0-100% load) (*3) mV 40 100 600 Temperature Coefficient (Ambient temperature -40℃ to +50℃ ) 80mV 200mV 300mV Max Power Total Regulation (max) (*4) % ± 3 ± 5 Maximum Ripple & Noise (typ/max) (*5) mVp-p 40/120 30/120 Function Over Current Protection (*6) Available Over Voltage Protection Not available Remote ON/OFF Control Available Environment Operating Temperature ℃ -40 to +85 Storage Temperature ℃ -40 to +85 Operating Humidity % RH 5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.) Storage Humidity % RH 5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.) Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each Shock 980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation Isolation Withstand Voltage Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute) Isolation Resistance Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50MΩ min Standards Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO) Mechanical Weight (typ) g 5.8 Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names. Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately. Note: For 12V/ ± 12V models, output power can be set to 15V/ ± 15V by connecting the output adjustment terminal TRM to -Vout. Note: For ± 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open. (*1) With nominal input voltage, maximum output current, and Ta=25°C. (*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed. (*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal). (*4) Output voltage includes input change, load change (balanced load), and temperature change. (*5) In 50MHz, Ta=25°C. (*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30 seconds. CC6-E

・All specifications are subject to change without notice. MODELITEMS/UNITS CC6-2403Sx-E CC6-2405Sx-E CC6-2412Sx-E CC6-2412Dx-E Input Nominal Voltage V DC24 Voltage Range V DC18-36 Efficiency (typ) (*1) % 77 81 87 86 Current (typ) (*1) A 0.214 0.309 0.287 0.291 Output Nominal Voltage VDC 3.3 5 12 15 ± 12 ± 15 Maximum Power (*2) W 3.96 6 Maximum Line Regulation(Within input voltage range) mV 20 40 80 Maximum Load Regulation (0-100% load) (*3) mV 40 100 600 Temperature Coefficient (Ambient temperature -40℃ to +50℃ ) 80mV 200mV 300mV Max Power Total Regulation (max) (*4) % ± 3 ± 5 Maximum Ripple & Noise (typ/max) (*5) mVp-p 40/120 30/120 Function Over Current Protection (*6) Available Over Voltage Protection Not available Remote ON/OFF Control Available Environment Operating Temperature ℃ -40 to +85 Storage Temperature ℃ -40 to +85 Operating Humidity % RH 5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.) Storage Humidity % RH 5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.) Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each Shock 980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation Isolation Withstand Voltage Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute) Isolation Resistance Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50MΩ min Standards Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO) Mechanical Weight (typ) g 5.8 Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names. Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately. Note: For 12V/ ± 12V models, output power can be set to 15V/ ± 15V by connecting the output adjustment terminal TRM to -Vout. Note: For ± 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open. (*1) With nominal input voltage, maximum output current, and Ta=25°C. (*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed. (*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal). (*4) Output voltage includes input change, load change (balanced load), and temperature change. (*5) In 50MHz, Ta=25°C. (*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30 seconds. MODELITEMS/UNITS CC6-4803Sx-E CC6-4805Sx-E CC6-4812Sx-E CC6-4812Dx-E Input Nominal Voltage V DC48 Voltage Range V DC36-76 Efficiency (typ) (*1) % 77 81 86 Current (typ) (*1) A 0.107 0.154 0.145 Output Nominal Voltage VDC 3.3 5 12 15 ± 12 ± 15 Maximum Power (*2) W 3.96 6 Maximum Line Regulation(Within input voltage range) mV 20 40 80 Maximum Load Regulation (0-100% load) (*3) mV 40 100 600 Temperature Coefficient (Ambient temperature -40℃ to +50℃ ) 80mV 200mV 300mV Max Power Total Regulation (max) (*4) % ± 3 ± 5 Maximum Ripple & Noise (typ/max) (*5) mVp-p 40/120 30/120 Function Over Current Protection (*6) Available Over Voltage Protection Not available Remote ON/OFF Control Available Environment Operating Temperature ℃ -40 to +85 Storage Temperature ℃ -40 to +85 Operating Humidity % RH 5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.) Storage Humidity % RH 5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.) Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each Shock 980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation Isolation Withstand Voltage Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute) Isolation Resistance Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50MΩ min Standards Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO) Mechanical Weight (typ) g 5.8 Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names. Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately. Note: For 12V/ ± 12V models, output power can be set to 15V/ ± 15V by connecting the output adjustment terminal TRM to -Vout. Note: For ± 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open. (*1) With nominal input voltage, maximum output current, and Ta=25°C. (*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed. (*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal). (*4) Output voltage includes input change, load change (balanced load), and temperature change. (*5) In 50MHz, Ta=25°C. (*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30 seconds. CC6-E

・All specifications are subject to change without notice. 3FDPNNFOEFENFBTVSFNFOUTGPSNPVOUJOHCPBSE 3FDPNNFOEFENFBTVSFNFOUTGPSNPVOUJOHCPBSE $POOFDUJPOEJBHSBN E-xDxxxx-6CCE-xSxxxx-6CC 8.5max.3.5 22.86 17.78 21.1±0.2 t=0.3 4.0 45.245.2 5.085.085.08 a b 7-0.3×0.6 ab 2.7 1.0 0.53.5 b 2.7 0.5a 5.085.085.08 20.32 10.16 15.24 17.87 2.63 22.86 2-ø1.5 (land diameter ø2.5) 7-ø1.0 (land diameter ø2.0) Unit: mm Allowable tolerance is ±0.5 if not specified separately. 8.8max. 22.86 21.1±0.2 t=0.3 4.0 $PQMBOBSJUZPSMPXFS 26.16 8.18.1 5.085.085.08 7-0.3×0.6 Unit: mm Allowable tolerance is ±0.5 if not specified separately. 5.085.08 10.16 15.24 (18.17) (2.93) 5.08 28.4 3.2 22.0 3.2 1.2 1 7 –Vout +Vout TRM RC +Vin –Vin 5FSNJOBMDPOOFDUJPOT No.1 +Vin No.2 RC No.3 –Vin No.4 NC No.5 –Vout No.6 TRM No.7 +Vout 1 7 COM –Vout +Vout TRM RC +Vin –Vin 5FSNJOBMDPOOFDUJPOT No.1 +Vin No.2 RC No.3 –Vin No.4 –Vout No.5 Common out No.6 TRM No.7 +Vout 4IBQF%JNFOTJPOT 4IBQF%JNFOTJPOT Outer shape of product Outer shape of product LoadLoad Load Outline Drawing CC6-xxxxxF-E (DIP type) CC6-xxxxxR-E (SMD type) CC6-E a b "NCJFOUUFNQFSBUVSF ˃$ 0VUQVUQPXFS a:0.5m/s(100LFM) b:1m/s(200LFM) /BUVSBMBJSDPPMJOH -40 -20ɹ 0ɹ 20ɹ 40ɹ60ɹ80ɹ100 100 0VUQVUQPXFSEFSBUJOHCZBNCJFOUUFNQFSBUVSF DPNNPOTQFDJGJDBUJPO Derating Curve

・All specifications are subject to change without notice. CC10-E Specifications MODELITEMS/UNITS CC10-0503Sx-E CC10-0505Sx-E CC10-0512Sx-E CC10-0512Dx-E Input Nominal Voltage V DC5.0 Voltage Range V DC4.5-9.0 Efficiency (typ) (*1) % 84 83 Current (typ) (*1) A 1.964 2.381 2.286 2.313 Output Nominal Voltage VDC 3.3 5 12 15 ± 12 ± 15 Maximum Power (*2) W 8.25 10 9.6 Maximum Line Regulation(Within input voltage range) mV 20 40 80 Maximum Load Regulation (0-100% load) (*3) mV 40 100 600 Temperature Coefficient (Ambient temperature -40℃ to +50℃ ) 80mV 200mV 300mV Max Power Total Regulation (max) (*4) % ± 3 ± 5 Maximum Ripple & Noise (typ/max) (*5) mVp-p 40/120 30/120 Function Over Current Protection (*6) Available Over Voltage Protection Not available Remote ON/OFF Control Available Environment Operating Temperature ℃ -40 to +85 Storage Temperature ℃ -40 to +85 Operating Humidity % RH 5-95 (the conditions of maximum 38℃ in wet bulb temperature and non-condensation should be ensured.) Storage Humidity % RH 5-95 (the conditions of maximum 38℃ in wet bulb temperature and non-condensation should be ensured.) Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each Shock 980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation Isolation Withstand Voltage Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute) Isolation Resistance Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50MΩ min Standards Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO) Mechanical Weight (typ) g 10 Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names. Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately. Note: For 12V/ ± 12V models, output power can be set to 15V/ ± 15V by connecting the output adjustment terminal TRM to -Vout. Note: For ± 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open. (*1) With nominal input voltage, maximum output current, and Ta=25°C. (*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed. (*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal). (*4) Output voltage includes input change, load change (balanced load), and temperature change. (*5) In 50MHz, Ta=25°C. (*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30 seconds. MODELITEMS/UNITS CC10-1203Sx-E CC10-1205Sx-E CC10-1212Sx-E CC10-1212Dx-E Input Nominal Voltage V DC12 Voltage Range V DC9.0-18 Efficiency (typ) (*1) % 84 86 88 86 Current (typ) (*1) A 0.318 0.969 1.136 1.047 Output Nominal Voltage VDC 3.3 5 12 15 ± 12 ± 15 Maximum Current A 2.500 2.000 1000 800 450 360 Maximum Power (*2) W 8.25 10 12 10.8 Maximum Line Regulation(Within input voltage range) mV 20 40 80 Maximum Load Regulation (0-100% load) (*3) mV 40 100 600 Temperature Coefficient (Ambient temperature -40℃ to +50℃ ) 80mV 200mV 300mV Max Power Total Regulation (max) (*4) % ± 3 ± 5 Maximum Ripple & Noise (typ/max) (*5) mVp-p 40/120 30/120 Function Over Current Protection (*6) Available Over Voltage Protection Not available Remote ON/OFF Control Available Environment Operating Temperature ℃ -40 to +85 Storage Temperature ℃ -40 to +85 Operating Humidity % RH 5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.) Storage Humidity % RH 5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.) Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each Shock 980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation Isolation Withstand Voltage Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute) Isolation Resistance Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50MΩ min Standards Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO) Mechanical Weight (typ) g 10 Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names. Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately. Note: For 12V/ ± 12V models, output power can be set to 15V/ ± 15V by connecting the output adjustment terminal TRM to -Vout. Note: For ± 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open. (*1) With nominal input voltage, maximum output current, and Ta=25°C. (*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed. (*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal). (*4) Output voltage includes input change, load change (balanced load), and temperature change. (*5) In 50MHz, Ta=25°C. (*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30 seconds. CC10-E

・All specifications are subject to change without notice. MODELITEMS/UNITS CC10-2403Sx-E CC10-2405Sx-E CC10-2412Sx-E CC10-2412Dx-E Input Nominal Voltage V DC24 Voltage Range V DC18-36 Efficiency (typ) (*1) % 84 86 87 86 Current (typ) (*1) A 0.409 0.484 0.575 0.523 Output Nominal Voltage VDC 3.3 5 12 15 ± 12 ± 15 Maximum Power (*2) W 8.25 10 12 10.8 Maximum Line Regulation(Within input voltage range) mV 20 40 80 Maximum Load Regulation (0-100% load) (*3) mV 40 100 600 Temperature Coefficient (Ambient temperature -40℃ to +50℃ ) 80mV 200mV 300mV Max Power Total Regulation (max) (*4) % ± 3 ± 5 Maximum Ripple & Noise (typ/max) (*5) mVp-p 40/120 30/120 Function Over Current Protection (*6) Available Over Voltage Protection Not available Remote ON/OFF Control Available Environment Operating Temperature ℃ -40 to +85 Storage Temperature ℃ -40 to +85 Operating Humidity % RH 5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.) Storage Humidity % RH 5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.) Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each Shock 980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation Isolation Withstand Voltage Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute) Isolation Resistance Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50MΩ min Standards Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO) Mechanical Weight (typ) g 10 Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names. Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately. Note: For 12V/ ± 12V models, output power can be set to 15V/ ± 15V by connecting the output adjustment terminal TRM to -Vout. Note: For ± 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open. (*1) With nominal input voltage, maximum output current, and Ta=25°C. (*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed. (*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal). (*4) Output voltage includes input change, load change (balanced load), and temperature change. (*5) In 50MHz, Ta=25°C. (*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30 seconds. MODELITEMS/UNITS CC10-4803Sx-E CC10-4805Sx-E CC10-4812Sx-E CC10-4812Dx-E Input Nominal Voltage V DC48 Voltage Range V DC36-76 Efficiency (typ) (*1) % 84 86 88 86 Current (typ) (*1) A 0.205 0.242 0.284 0.262 Output Nominal Voltage VDC 3.3 5 12 15 ± 12 ± 15 Maximum Power (*2) W 8.25 10 12 10.8 Maximum Line Regulation(Within input voltage range) mV 20 40 80 Maximum Load Regulation (0-100% load) (*3) mV 40 100 600 Temperature Coefficient (Ambient temperature -40℃ to +50℃ ) 80mV 200mV 300mV Max Power Total Regulation (max) (*4) % ± 3 ± 5 Maximum Ripple & Noise (typ/max) (*5) mVp-p 40/120 30/120 Function Over Current Protection (*6) Available Over Voltage Protection Not available Remote ON/OFF Control Available Environment Operating Temperature ℃ -40 to +85 Storage Temperature ℃ -40 to +85 Operating Humidity % RH 5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.) Storage Humidity % RH 5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.) Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each Shock 980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation Isolation Withstand Voltage Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute) Isolation Resistance Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50MΩ min Standards Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO) Mechanical Weight (typ) g 10 Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names. Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately. Note: For 12V/ ± 12V models, output power can be set to 15V/ ± 15V by connecting the output adjustment terminal TRM to -Vout. Note: For ± 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open. (*1) With nominal input voltage, maximum output current, and Ta=25°C. (*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed. (*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal). (*4) Output voltage includes input change, load change (balanced load), and temperature change. (*5) In 50MHz, Ta=25°C. (*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30 seconds. CC10-E

・All specifications are subject to change without notice. 4IBQF%JNFOTJPOT 4IBQF%JNFOTJPOT 3FDPNNFOEFENFBTVSFNFOUTGPSNPVOUJOHCPBSE 3FDPNNFOEFENFBTVSFNFOUTGPSNPVOUJOHCPBSE $POOFDUJPOEJBHSBN E-xDxxxx-01CCE-xSxxxx-01CC 8.5max.3.5 35.56 25.4 22.6±0.2 t=0.3 4.0 25.4 80.580.5 (3.68)(3.68) 5.08 10.16 5.085.085.08 2.7 1.0 2.7 0.53.5 0.5a b 7-0.3×0.6 a b b a 30.48 3.38 18.62 10.16 15.24 5.085.085.08 2-ø1.5 (land diameter ø2.5) 7-ø1.0 (land diameter ø2.0) 35.56 Unit: mm Allowable tolerance is ±0.5 if not specified separately. 35.56 22.6±0.2 t=0.34.0 38.86 8.18.1(3.68)(3.68) 5.08 10.16 5.085.085.08 8.8max. 7-0.3×0.6 5.085.085.08 1.2 (3.68) (18.92) 10.16 15.24 41.0 3.2 34.6 3.2 Unit: mm Allowable tolerance is ±0.5 if not specified separately. 1 7 –Vout +Vout TRM RC +Vin –Vin 5FSNJOBMDPOOFDUJPOT No.1 +Vin No.2 RC No.3 –Vin No.4 NC No.5 –Vout No.6 TRM No.7 +Vout 1 7 COM –Vout +Vout TRM RC +Vin –Vin 5FSNJOBMDPOOFDUJPOT No.1 +Vin No.2 RC No.3 –Vin No.4 –Vout No.5 Common out No.6 TRM No.7 +Vout Coplanarity: 0.1 or lower 0VUFSTIBQFPG QSPEVDU LoadLoad Load Outer shape of product Outline Drawing CC10-xxxxxF-E (DIP type) CC10-xxxxxR-E (SMD type) CC10-E a b "NCJFOUUFNQFSBUVSF ˃$ 0VUQVUQPXFS a:0.5m/s(100LFM) b:1m/s(200LFM) /BUVSBMBJSDPPMJOH -40 -20ɹ 0ɹ 20ɹ 40ɹ60ɹ80ɹ100 100 0VUQVUQPXFSEFSBUJOHCZBNCJFOUUFNQFSBUVSF DPNNPOTQFDJGJDBUJPO Derating Curve

・All specifications are subject to change without notice. CC15-E Specifications Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names. Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately. (*1) With nominal input voltage, maximum output current, and Ta=25°C. (*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed. (*3) Output voltage includes input change, load change (balanced load), and temperature change. (*4) In 50MHz, Ta=25°C. (*5) Latch method Resumes by restarting input or resetting remote on/off. CC15-E MODELITEMS/UNITS CC15-2403Sx-E CC15-2405Sx-E Input Nominal Voltage V DC24 Voltage Range V DC18-36 Efficiency (typ) (*1) % 89 Current (typ) (*1) A 0.695 0.702 Output Nominal Voltage VDC 3.3 5 Maximum Current A 4.500 3.000 Maximum Power (*2) W 14.85 15 Maximum Line Regulation(Within input voltage range) mV 65 100 Maximum Load Regulation (0-100% load) mV 120 200 Temperature Coefficient (Ambient temperature -40℃ to +50℃ ) 80mV Max Power Total Regulation (max) (*3) % +5/-3 Maximum Ripple & Noise (typ/max) (*4) mVp-p 40/120 Voltage Adjustable Range Not available Function Over Current Protection (*5) Available Over Voltage Protection Not available Remote ON/OFF Control Available Environment Operating Temperature ℃ -40 to +85 Storage Temperature ℃ -40 to +85 Operating Humidity % RH 5-95 (the conditions of maximum 38℃ in wet bulb temperature and non-condensation should be ensured.) Storage Humidity % RH 5-95 (the conditions of maximum 38℃ in wet bulb temperature and non-condensation should be ensured.) Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each Shock 980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation Isolation Withstand Voltage Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute) Isolation Resistance Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50MΩ min Standards Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO) Mechanical Weight (typ) g 12.5

・All specifications are subject to change without notice. 4IBQF%JNFOTJPOT 3FDPNNFOEFENFBTVSFNFOUTGPSNPVOUJOHCPBSE $POOFDUJPOEJBHSBN 7.0max.3.0 37.55 25.4 570.6570.6 38.1 32.1 t=0.3 (4.62)(4.62) 2.54 2.5410.16 2.7 1.0 2.7 0.53.50.5 a b b a ba 17-0.3×0.6 P P P P P P P P 4.47 22.86 27.33 10.16P P P P P P=2.5437.55 31.475 6.075 25-ø1.0 (land diameter ø2.0) Outer shape of product 2-ø1.5 (land diameter ø2.5) Unit: mm Allowable tolerance is ±0.5 if not specified separately. P P P P P P P P 4.47 22.86 27.33 10.16 P P P P P P P=2.5443.0 36.63.2 3.2 1.2 Unit: mm Allowable tolerance is ±0.5 if not specified separately. 7.5max. 40.9 38.1 32.1 t=0.3 (4.62)(4.62) 2.54 2.5410.16 1 17 17-0.3×0.6 1.8 1.8 $PQMBOBSJUZPSMPXFS 11 +Vout –Vout +Vin –Vin RC 5FSNJOBMDPOOFDUJPOT No.1 NC No.10 N C No.2 NC No.11 N C No.3 RC No.12 + Vout No.4 NC No.13 + Vout No.5 NC No.14 + Vout No.6 +Vin No.15 – Vout No.7 +Vin No.16 – Vout No.8 –Vin N o.17 NC No.9 –Vin 4IBQF%JNFOTJPOT 3FDPNNFOEFENFBTVSFNFOUTGPSNPVOUJOHCPBSE Outer shape of product -PBE CC15-E Outline Drawing CC15-xxxxxSF-E (DIP type) CC15-xxxxxSR-E (SMD type) a b "NCJFOUUFNQFSBUVSF ˃$ 0VUQVUQPXFS a:0.5m/s(100LFM) b:1m/s(200LFM) /BUVSBMBJSDPPMJOH -40 -20ɹ 0ɹ 20ɹ 40ɹ60ɹ80ɹ100 100 0VUQVUQPXFSEFSBUJOHCZBNCJFOUUFNQFSBUVSF DPNNPOTQFDJGJDBUJPO Derating Curve

・All specifications are subject to change without notice. CC25-E Specifications MODELITEMS/UNITS CC25-2403Sx-E CC25-2405Sx-E Input Nominal Voltage V DC24 Voltage Range V DC18-36 Efficiency (typ) (*1) % 90 Current (typ) (*1) A 1.146 1.157 Output Nominal Voltage VDC 3.3 5 Maximum Current A 7.500 5.000 Maximum Power (*2) W 24.75 25 Maximum Line Regulation (Within input voltage range) mV 65 100 Maximum Load Regulation (0-100% load) mV 120 200 Temperature Coefficient (Ambient temperature -40℃ to +50℃ ) 80mV Max Power Total Regulation (max) (*3) % +5/-3 Maximum Ripple & Noise (typ/max) (*4) mVp-p 40/120 Voltage Adjustable Range VDC Not available Function Over Current Protection (*5) Available Over Voltage Protection Not available Remote ON/OFF Control Available Environment Operating Temperature ℃ -40 to +85 Storage Temperature ℃ -40 to +85 Operating Humidity % RH 5-95 (the conditions of maximum 38℃ in wet bulb temperature and non-condensation should be ensured.) Storage Humidity % RH 5-95 (the conditions of maximum 38℃ in wet bulb temperature and non-condensation should be ensured.) Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each Shock 980m/s² (100G), 6ms, 3 directions, 3 times for each, in non-operation Isolation Withstand Voltage Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute) Isolation Resistance Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50MΩ min Standards Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO) Mechanical Weight (typ) g 20 Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names. Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately. (*1) With nominal input voltage, maximum output current, and Ta=25°C. (*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed. (*3) Output voltage includes input change, load change (balanced load), and temperature change. (*4) In 50MHz, Ta=25°C. (*5) Latch method Resumes by restarting input or resetting remote on/off. CC25-E

・All specifications are subject to change without notice. 4IBQF%JNFOTJPOT 3FDPNNFOEFENFBTVSFNFOUTGPSNPVOUJOHCPBSE 3FDPNNFOEFENFBTVSFNFOUTGPSNPVOUJOHCPBSE $POOFDUJPOEJBHSBN 7.0max.3.0 42.65 30.5 570.6570.6 43.2 44.9 t=0.3 5.08 5.082.54 (4.67)10.16 ab ba 25-0.3×0.6 (4.67) b a 2.7 1.0 2.7 0.53.50.5 10.16 P P P P P P P P P P P P P P P PP P P P 4.52 5.08 35.56 40.08 P=2.54 36.575 42.65 6.075 25-ø1.0 (land diameter ø2.0) 2-ø1.5 (land diameter ø2.5) 5.08 Unit: mm Allowable tolerance is ±0.5 if not specified separately. 7.5max. 46.0 43.2 44.9 t=0.3 Coplanarity: 0.1 or lower Outer shape of product 1.8 1.8 5.08 5.082.54 (4.67)10.16 (4.67) 10.16P P P PP P P P PP P=2.54 41.7 3.23.2 48.1 P P P P P P P P P P 4.52 5.08 35.56 40.08 5.08 Unit: mm Allowable tolerance is ±0.5 if not specified separately. +Vout –Vout –Vin +Vin -PBE RC 5FSNJOBMDPOOFDUJPOT No.1 NC No.10 + Vin No.19 –Vout No.2 NC No.11 + Vin No.20 –Vout No.3 NC No.12 + Vin No.21 –Vout No.4 RC No.13 N C No.22 –Vout No.5 NC No.14 N C No.23 –Vout No.6 NC No.15 + Vout No.24 – Vout No.7 –Vin No.16 + Vout No.25 N C No.8 –Vin No.17 + Vout No.9 –Vin No.18 + Vout 4IBQF%JNFOTJPOT Outer shape of product Outline Drawing CC25-xxxxSF-E (DIP type) CC25-xxxxSR-E (SMD type) a b "NCJFOUUFNQFSBUVSF ˃$ 0VUQVUQPXFS a:0.5m/s(100LFM) b:1m/s(200LFM) /BUVSBMBJSDPPMJOH -40 -20ɹ 0ɹ 20ɹ 40ɹ60ɹ80ɹ100 100 0VUQVUQPXFSEFSBUJOHCZBNCJFOUUFNQFSBUVSF DPNNPOTQFDJGJDBUJPO Derating Curve CC25-E

・All specifications are subject to change without notice. CC-E Instruction Manual 1. Remote On/Off terminal (RC) 1.5-10W type Open collector is recommended as the connection system. Consult us for use with other systems. Use a transistor with "V CE: Vin or over" and "Ic: 1mA or over". Output is switched off by setting the RC terminal open, and switched on by setting the RC terminal to LOW (0-0.4V). RC control signal +Vin +Vout –Vin –Vout RC Load When not using this function (always on), short-circuit be - tween RC terminal and -Vin terminal. +Vin +Vout –Vin –Vout RC 8IFOOPU VTJOHUIJT GVODUJPO BMXBZTPO Load 15/25W type Output is switched on by setting the RC terminal to open, and switched off by setting the RC terminal to HIGH (con - necting to Vin terminal). RC control signal +Vin +Vout –Vin –Vout RC Load When not using this function (always on), set the RC termi- nal to open. +Vin +Vout –Vin –Vout RC 8IFOOPU VTJOHUIJT GVODUJPO BMXBZTPO Load 1-2. Output voltage adjusting ter - minal (TRM) (1.5-10W type) Output voltage can be set to the values shown in the figure below by connecting the TRM terminal to the -Vout termi - nal. When not using this function (always on), set the TRM ter - minal to open. Note that when the output voltage is set high by this func - tion, derating of output current is necessary according to the maximum power. DIP/SMDNPEFMT To be replaced with 1R5(1.5W), 3(3W), 6(6W), or 10(10W) for actual model names. Model name Open Connection to -Vout Fig. CC –xx03Sx–E 3.3V 3.6V 1 CC –xx05Sx–E 5V 6V 1 CC –xx12Sx–E 12V 15V 1 CC –xx12Dx–E ±12V ±15V 2 Fig.1 Fig.2 +Vin +Vout TRM –Vin –Vout +Vin –Vin –Vout TRM +Vout 3.3V 12V 3.6V 15V +Vin +Vout TRM COM –Vin –Vout +Vin –Vin –Vout +Vout -PBE -PBE -PBE -PBETRM COM +12V –12V +15V –15V Load Load SIPNPEFMT Model name Model name Connection to -Vout Fig. CC3–xx03SS–E 3.3V 3.67V 3 CC3–xx05SS–E 5V 6V 3 CC3–xx12SS–E 12V 15V 3 CC3–xx12DS–E ±12V ±15V 4 Fig.3 Fig.4 +Vin +Vout TRM –Vin –Vout -PBE -PBE +Vin +Vout TRM –Vin –Vout 3.3V V76.3V21 15V +Vin +Vout TRM –Vin –Vout -PBE -PBE COM +Vin +Vout TRM –Vin –Vout -PBE -PBE COM +12V –12V +15V –15V 1. Control functions/Protection functions/Connections

・All specifications are subject to change without notice. For ±the 12V output model, output voltage can be set to 24V single output by making the COM terminal and TRM terminal open. And output voltage can be set to 30V single output by making the COM terminal open and connecting the TRM terminal to the -Vout terminal. NPEFMT Model name COM terminal TRM terminal Single output Fig. * To be replaced with 1R5(1.5W), 3(3W), 6(6W), or 10(10W) for actual model names. Open Open Open Connection to -Vout 6.giF5.giF +Vin –Vin –Vout +Vout TRM COM 24V +Vin –Vin –Vout +Vout TRM COM 30V Load Load NPEFMT TRM terminal Single output Fig.Model name COM terminal Open Open Open Connection to -Vout 8.giF7.giF +Vin +Vout TRM –Vin –Vout -PBE COM 24V +Vin +Vout TRM –Vin –Vout -PBE COM 30V 1-3. Output voltage adjusting func - tion (adding external resistance) (1.5-10W type) Output voltage can be varied in the range shown in the fig- ure below by connecting a resistance (Ra, Rb) between the TRM terminal and the -Vout terminal or between the TRM terminal and +Vout terminal. Note that when the output voltage is set high, derating of output current is necessary according to the maximum power. NPEFMT UP UP UP UP UP UP UP UP Model name Fig. Fig.Connection between -Vout and Ra Connection between +Vout and Rb * To be replaced with 1R5(1.5W), 3(3W), 6(6W), or 10(10W) for actual model names. Calculating output voltage Vout (V) from connected resis - tance Ra, Rb (kΩ) Adding a resistance Ra between TRM terminal and -Vout terminal, to set the output voltage high Adding a resistance Rb between TRM terminal and +Vout terminal, to set the output voltage low Calculating connected resistance Ra, Rb (kΩ) from set out- put voltage Vout (V) Adding a resistance Ra between TRM terminal and -Vout terminal, to set the output voltage high Adding a resistance Rb between TRM terminal and +Vout terminal, to set the output voltage low 01.giF9.giF 21.giF11.giF Ra –Vout TRM +Vout 3.3ʙ3.6V 5ʙ6V 12ʙ15V Rb –Vout TRM +Vout 3.15ʙ3.3V 4.75ʙ5V 11.4ʙ12V Ra –Vout TRM +Vout COM -PBE -PBE +12ʙ+15V –12ʙ–15V Rb –Vout TRM +Vout COM -PBE -PBE +11.4ʙ+12V –11.4ʙ–12V Load Load NPEFMT Model name Fig. Fig.Connection between -Vout and Ra Connection between +Vout and Rb * To be replaced with 1R5(1.5W), 3(3W), 6(6W), or 10(10W) for actual model names. UP UP UP UP UP UP UP UP Calculating output voltage Vout (V) from connected resis - tance Ra, Rb (kΩ) Adding a resistance Ra between TRM terminal and -Vout terminal, to set the output voltage high Adding a resistance Rb between TRM terminal and +Vout terminal, to set the output voltage low

・All specifications are subject to change without notice. Calculating connected resistance Ra, Rb (kΩ) from set out- put voltage Vout (V) Adding a resistance Ra between TRM terminal and -Vout terminal, to set the output voltage high Adding a resistance Rb between TRM terminal and +Vout terminal, to set the output voltage low 41.giF31.giF 61.giF51.giF +Vout TRM –Vout Load Ra 3.3ʙ3.67Vɺ5ʙ6Vɺ12ʙ15V Load Rb +Vout TRM –Vout 3.15ʙ3.3Vɺ4.75ʙ5Vɺ11.4ʙ12V +Vout TRM –Vout Load Load COM Ra +12ʙ+15V –12ʙ–15V +Vout TRM –Vout Load Load COM Rb +11.4ʙ+12V –11.4ʙ–12V 1-4. Over current protection 1.5-10W type An over current protection circuit is incorporated in the model, and if over current occurs, the output voltage is lowered. By removing the over current and shorted condi - tions, the output voltage automatically resumes. Note that if the over current status continues for 30 seconds or over, the internal elements of the converter may be deteriorated or damaged. The current value, from which it is judged as an over current, is not to be lower than the nominal current value. If the output voltage does not resume even after re - moving the over current conditions and any causes, turn off the power or remote control once, and then restart it. 15/25W type An over current protection circuit is incorporated in the model, and if over current occurs, the output voltage is lowered and the converter is stopped and latched. The output voltage does not automatically resume even after removing the over current and shorted conditions. To resume output voltage, restart input or reset remote on/ off. The current value, from which it is judged as an over cur - rent, is not to be lower than the nominal current value. 1-5. Over voltage protection An over voltage protection function is not incorporated in the model. Be careful if an external voltage over the nomi - nal voltage is applied, damage may be caused. 1-6. Low input voltage protection This series is equipped with the low input voltage protec - tion in order to prevent malfunction due to low input volt - age. The converter stops operation if the input voltage become lower than the set voltage. The set ranges are shown in the table below. .PEFMOBNF *OQVUWPMUBHFSBOHF Voltage range set for protection circuit To be replaced with 1R5(1.5W), 3(3W), 6(6W), or 10(10W) for actual model names. UP UP UP UP UP UP UP UP UP UP UP UP 1-7. Insulation withstand voltage The insulation withstand voltage between input and output, and between terminal and case, is AC500V. 1-8. Series/Parallel connections Series connection Serial connection is applicable by wiring as shown in the figure below (left). If output voltage is not generated by this connection, connect a Schottky diode in which the forward voltage is possibly low. Also note that the Schottky diode should have a reverse voltage that is twice or over the value of the voltage be - tween +Vout and -Vout. And the output current should be the same or lower than the nominal current value, whichever is smaller in the con - verters. +Vin +Vout –Vin –Vout +Vin +Vout –Vin –Vout +Vin +Vout –Vin –Vout +Vin +Vout –Vin –Vout Load Load Parallel connection Parallel connection is not applicable.

・All specifications are subject to change without notice. 2-1. Ripple noise measurement method The measured value of the converter noise may differ de - pending on the measurement method. Measurement should be conducted in a position close to the output terminal. When connecting a prove, do not allow a loop to be config- ured in order not to pick up flux. As well, note that the spike voltage greatly differs depend - ing on the ripple voltmeter and frequency band of the oscil- loscope. Our noise measurement is conducted by the wiring shown in the figure below and in the frequency band of 50MHz. +Vin Vin Vout Iin +Vout –Vin –Vout lout 1.5m 50Ω coaxial cable 50MHz 0.1µF A V 10mm 20mm 50MHz V A 3JQQMF WPMUNFUFSPS &OEQPJOU⒋ 0TDJMMPTDPQF Load 2-2. Input ripple noise This series is equipped with a built-in capacitor for input. Therefore, this series can operate without an external capacitor connected to input. However, by connecting a capacitor, input ripple noise and input return noise can be reduced. In addition, it is more effective if a π type filter is installed as shown in the figure below. +Vin +Vout –Vin –Vout +Vin +Vout –Vin –Vout Load Load When the distance to the input of the converter from the input power supply is long, attach a capacitor as close as possible to the input terminal. +Vin +Vout –Vin –Vout Load When the distance to the input of the converter from the input power supply is long, the impedance of the input line can become high, causing high spike noise. In this case, it is recommended to connect a capacitor as close as possible to the input of the DC-DC converter. 2-3. Output ripple & noise To reduce Output ripple & noise, connect a capacitor to the output of the converter. In addition, reduction can be enhanced if a π type filter is incorporated as shown in the figure below. In this case, use of a coil with around 100µH is recommended. +Vin +Vout –Vin –Vout +Vin +Vout –Vin –Vout Load Load When the distance to the load from the output of the con - verter is long, connect the capacitor as close as possible to the load. To reduce output spike noise, connect a ceramic capacitor with around 1µF to the output of the converter. +Vin +Vout –Vin –Vout 1MF Load 2-4. Capacity of external capaci - tor connected to output Note that if a capacitor with capacity over the value shown in the table below is connected to the output, or several capacitors with low impedance are connected in parallel, operation of the converter may become unstable. Model name Electrostatic capacitance (µF) max. 2. Noise reduction methods

・All specifications are subject to change without notice. 3-1. Soldering conditions ˔4PMEFSJOHDPOEJUJPOT ɹ%*1NPEFMT4*1NPEFMT 0CTFSWFUIFGPMMPXJOHDPOEJUJPOTJOTPMEFSJOHCPBSE 4PMEFSEJQ 260°C, 10s max. 4PMEFSJOHDPQQFS 380°C, 3s max. 4.%NPEFMT -FBEGSFFTPMEFSJOH)JHIUFNQFSBUVSFSFqPXQSPDFTT 150˚C 180˚C 225˚C min. 245˚C max. 4VSGBDFUFNQFSBUVSFPGQBSUT 40 to 100s1 to 3˚C/s 1 to 4˚C/s 30p20s 1 to 5˚C/s 3-2. Cleaning method Board cleaning after soldering is not recommended. How - ever, the cleaning fluids and conditions shown in the table below have been tested and proved to have no problem. These fluids and conditions can be used. Consult us for using cleaning fluids other than those shown below. Cleaning fluids and test conditions Cleanthrough 750H (1) Cleaning (shaking) at 60° C for 4 minutes (2) Rinsing (shaking in water) at 60° C for 4 minutes (3) Rinsing (shaking in water) at ordinary temperature - 40° C for 4 minutes (4) Drying at 70° C for 6 minutes Pine alpha ST100S (1) Cleaning (shaking) at 60° C for 5 minutes (2) Rinsing (shaking in water) at 30° C for 3 minutes (3) Drying at 70° C for 6 minutes Terpene Cleaner EC-7R (1) Cleaning (shaking) at 60° C for 5 minutes (2) Rinsing (shaking in IPA) at 30° C for 10 minutes (3) Drying at 70° C for 6 minutes Isopropyl alcohol (1) Ultrasonic waves at 60° C for 1 minute (2) Cool bath cleaning R.T. for 1 minute (3) Vapor cleaning at 83° C for 1 minutes Asahiklin AK-225AES (1) Ultrasonic waves at 50° C for 2 minutes (2) Cool bath cleaning R.T. for 2 minutes 3. Soldering conditions/Cleaning conditions 2-5. Common mode noise For products other than with 10W, capacitors are not con - nected between the primary GND and the secondary GND. To reduce common mode noise, connect a capacitor with around 1000pF between the primary GND and the second- ary GND, as shown in the figure below. In this case, note that if the capacitor that is connected is too large, coupling capacitance between input and output becomes large. Also be careful about the withstand voltage of the capacitor (500V or over is desirable with consideration of the insula- tion withstand voltage). +Vin +Vout –Vin –Vout Load For products with 10W, capacitors with 1000pF are inter - nally connected between primary and secondary. 2-6. Radiation noise Radiation noise of the converter can be reduced by con - necting the case terminal to the input or output GND ter - minal. The effectiveness varies depending on the device. Check it on the actual device. Regarding wiring, use GND line and solid pattern for the bottom of the converter as much as possible. - SMD models are not equipped with case terminals.