DS_CAR100M_G Subject to technical changes without notice * Released document – Copy is not subject to revision service! 1 / 3 CAR100M Car Adapter DC/DC Features: Wide input voltage range Max. output power 110.00W Galvanic isolation for maximum patient safety Car/Truck input connector Wall-mount kit optional Applications: Suitable for use with all mobile medical devices (e.g. respirator, defibrillator, suction pump etc.)
DS_CAR100M_G Subject to technical changes without notice * Released document – Copy is not subject to revision service! 2 / 3 Specification Input Voltage range 10.00 – 32.00VDC Stand-by current Typical 45.00mA @ 10.00V input Typical 35.00mA @ 32.00V input Input fuse 13.00A Protection Reverse polarity Over voltage protection (Transient suppression circuit) Output Voltage range 16.00 – 24.00V nominal Power 100.00W cont. Initial set tolerance ±3% max. Load regulation -4% max. Line regulation ±1% max. Ripple & Noise < 120.00mVpk-pk Current limit Constant current Protection Short circuit, over temperature protection, over voltage protection Environmental Operation: Storage: Ambient Temperature -20°C to 40°C 40°C to 50°C, derating 35% -40°C to 75°C Pressure & Altitude 1200hPa to 570hPA max. 4600m above sea level 1200hPa to 115hPa max. 15000m above sea level Humidity (non-condensing) 5% to 95% r.H. 5% to 95% r.H. General Galvanic isolation Isolation voltage 2.00kV Input connector Cigarette lighter adapter Output connector Customer-specific Efficiency Typical 88% at 100% load MTBF > 100000h @ 25°C ambient temperature and GB per MIL HDBK217F Green procurement WEEE RoHS Indicator Single green LED Ingress protection rating IEC60529, IP42 Cooling Convection cooled Safety & EMC Regulatory approvals Europe United Kingdom International USA/Canada Australia & New Zealand CE UKCA CB Report IEC 60601-1 3rd edition UL60601-1 RCM Electromagnetic Emissions Europe USA Medical electrical equipment Airborne equipment EN 55011/55022 class B FCC15 class B IEC60601-1-2 RTCA/DO-160F, Section 21 Electromagnetic Immunity ESD immunity IEC61000-4-2, 8kV contact/ 15kV air Electromagnetic field immunity IEC61000-4-3, 80-2700MHz, 30V/m, modulation 80%/200Hz Electrical fast transient/burst immun- ity test IEC61000-4-4,+/-2kV, 5/50ns Surge immunity test Conducted Immunity IEC61000-4-5,+/-0,5kVsym, 1.2/50(8/20)µs IEC61000-4-6, 0.15-80MHz, 10V, 80%, 1KHz, AM, with CDN ISO-Impulses Medical electrical equipment ISO7637-2, pulse 1 till 5, immunity test level III IEC60601-1-2 - other approvals on request
DS_CAR100M_G Subject to technical changes without notice * Released document – Copy is not subject to revision service! 3 / 3 Mechanical Details Housing dimensions (LxWxH) 165.00 x 64.00 x 38.00mm, without cables and connectors Input cable length 240cm ±5% Output cable length 100cm ±5% Weight Approx. 420g, without cables, connectors and wall-mount kit Germany/Headquarters USA Hong Kong China RRC power solutions GmbH Technologiepark 1
66424 Homburg / Saar
Tel.: +49 6841 98090 Fax: +49 6841 9809280 Email: sales@rrc-ps.de Web: www.rrc-ps.com RRC power solutions Inc. 18340 Yorba Linda Blvd., # 107-437 Yorba Linda, CA 92886 Tel.: +1 714 777 3604 Fax: +1 714 777 3658 Email: usa@rrc-ps.com Web: www.rrc-ps.com RRC power solutions Ltd. S-V,6/F, Valiant Industrial Centre 2-12 Au Pui Wan Street Fo Tan, N.T., Hong Kong Tel.: +852 2376 0106 Fax: +852 2375 0107 Email: hkrrc@rrc-ps.cn Web: www.rrc-ps.cn RRC power solutions Ltd. Room 1306, C Building, Tianan International building, Renmin South Road, Luohu District, Shenzhen 518021 Tel.: +86 755 8374 1908 Fax: +86 755 8374 1861 Email: hkrrc@rrc-ps.cn Web: www.rrc-ps.cn