Cage-Protected Submersible
613613 SERIES
Industrial Level Transmitters & Transducers
APPLICATIONS
■ Lift stations ■ Sewage ■ Slurry tanks ■ Storm canals ■ Water & wastewater ■ Wet wells SPECIFICATIONS Output signals 4 mA to 20 mA, 2-wire; 0 Vdc to 5 Vdc and 0 Vdc to 10 Vdc, 3-wire; 0.5 Vdc to 2.5 Vdc, 3-wire Pressure ranges 0 psi to 5 psi through 0 psi to 300 psi Accuracy ± 0.25% full scale (BFSL); optional ± 0.125% full scale (BFSL); (includes the effects of non-linearity, hysteresis, non-repeatability, zero point and full scale errors) Stability ≤ ± 0.2% full scale for 1 year, non-accumulating Response time ≤ 1 ms (between 10% and 90% full scale) Service life > 100,000,000 full scale cycles Temperature measurement Optional PT100, 4-wire per IEC 60751 Temperature ranges Compensated 32 °F to 122 °F/0 °C to 50 °C Effect ± 0.01%/ °F for zero and span Media 14 °F to 122 °F / -10 °C to 50 °C Storage -22 °F to 175 °F/ -30 °C to 80 °C Power requirement* 10 Vdc to 30 Vdc (4 mA to 20 mA, 2-wire, 0 Vdc to 5 Vdc, 3-wire) 5 Vdc to 30 Vdc (0.5 Vdc to 2.5 Vdc, 3-wire)
14 Vdc to 30 Vdc (0 Vdc to 10 Vdc, 3-wire)
Load limitations ≤ (VPower-10)/0.020 Amp for 4 mA to 20 mA ≥ 10,000 Ω for 0 Vdc to 10 Vdc, 3-wire ≥ 5,000 Ω for 0 Vdc to 5 Vdc, 3-wire Proof pressure 2 times range Burst pressure 4 times range Measuring element Cage seal: All 316 Stainless Steel Cable: Polyurethane, optional FEP Connection 316 Stainless Steel Housing material 316 Stainless Steel Environmental rating IP68 Electromagnetic rating Built to suppress RFI, EMI and ESD protection Electrical protection Reverse polarity protection, short circuit and optional lightning protection per EN 6100-4-5; 1.5J Shock 100 g’s according to IEC 60068-2-27 Vibration 15 g’s according to IEC 60068-2-6 Weight Approximately 3.2 lb. - cable extra * Unregulated
- Ranges from 0 psi to 5 psi through 0 psi to 300 psi
- Current & voltage outputs available
- 316 Stainless Steel and polyurethane wetted parts WARNING: This product can expose you to chemicals including Lead and Nickel, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
613 SERIES
ORDERING INFORMATION
5 0 psi to 5 psi (11.55 ft/H2O) 20 0 psi to 20 psi (46.20 ft/H 2O) 75 0 psi to 75 psi (173.25 ft/H 2O) 300 0 psi to 300 psi (693 ft/H 2O) 10 0 psi to 10 psi (23.10 ft/H2O) 30 0 psi to 30 psi (69.30 ft/H 2O) 100 0 psi to 100 psi (231.00 ft/H 2O) 15 0 psi to 15 psi (34.65 ft/H 2O) 50 0 psi to 50 psi (115.50 ft/H 2O) 150 0 psi to 150 psi (346.50 ft/H 2O) ACCURACIES 1 ±0.25% full scale (BFSL) 2 ±0.125% full scale (BFSL) OUTPUT SIGNALS 1 4 mA to 20 mA, 2-wire 5 0 Vdc to 10 Vdc, 3-wire 2 0 Vdc to 5 Vdc, 3-wire 11 0.5 Vdc to 2.5 Vdc, 3-wire ELECTRICAL CONNECTIONS XX Standard polyurethane (PUR) cable 38-XX Optional FEP cable NOTE: XX = length of cable in feet. OPTIONS CBC Cable Clamp FE Filter Element LP Lightning Protection * PT1 PT100 RTD * DC Desiccant Cartridge JB Cable Junction Box LR Lifting Ring Please consult your local NOSHOK Distributor or NOSHOK, Inc. for availability and delivery information. * Only available with PUR cable Optional Lifting Ring Optional Cable Junction Box Optional Desiccant Cartridge Optional Cable Clamp Optional Filter Element 1.06″ (27 mm) 2.14″ (54 mm) Active area Ø 3.75″ (95 mm) 4.44″ (113 mm) Ø 1.06″ (27 mm) 1/2″ NPT 1.25″ (32 mm) 1.75″ (44 mm) 0.25″ (6 mm) 613 – 5 – 1 – 1 – 50' – LR EXAMPLE
613 Series Wiring 0-5 Vdc, 0-10 Vdc,
0.5 to 2.5 Vdc CONNECTION TYPE (CODE) V+ COMMON OUTPUT CASE GROUND PUR Cable Brown Green White Gray FEP Cable Brown Green White Gray
613 Series Wiring 4 mA to 20 mA
CONNECTION TYPE (CODE) V+ V- CASE GROUND PUR Cable Brown Green Gray FEP Cable Brown White Blue Load Limitations 4 mA to 20 mA output Vmin = [10V + (.020 x RL)] - RC RL = RS + RW RL = Loop resistance (Ω) RS = Sensor resistance (Ω) RW = Wire resistance (Ω) RC = 0.0435 x cable length (ft.)Ft. WARNING: This product can expose you to chemicals including Lead and Nickel, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov