C5570 BELDEN | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 2

Technical content

Product: C5570 Teck90 600V, 12+G C #10+12 Str BC, XLPE Ins M4, PVC Jkt, AIA Armor, Blk PVC Jkt, CSA HL SUN RES -40C Product Description Teck90 600V, 12+G Conductor 10+12AWG (7x18H) Bare Copper, XLPE Insulation M4 Color Code, PVC Inner Jacket, Aluminum Interlock Armor, Black PVC Outer Jacket, CSA HL SUN RES -40C Technical Specifications Product Overview Suitable Applications: CEC Power and Control Applications up to 600V Construction Details Conductor Element No. of Elements Size Stranding Material Conductor(s) 12 10 AWG 7x18 BC - Bare Copper Ground Wire 1 12 AWG 7x20 BC - Bare Copper Insulation Element Material Nom. Thickness Nom. Insulation Diameter Color Code Conductor(s) XLP, XLPO, XLPE (Thermoset) 0.030 in (0.76 mm) 0.174 in (4.42 mm) Black and Numbered Ground Wire No Insulation Outer Shield Material No Shield Inner Jacket Material Nom. Thickness Nom. Diameter Ripcord Color PVC - Polyvinyl Chloride 0.083 in (2.1 mm) 0.888 in (22.6 mm) Yes Black Armor Armor Type & Material Armor Thickness Diameter Over Armor AIA - Aluminum Interlock Armor 0.034 in (0.86 mm) 1.148 in (29.16 mm) Outer Jacket Material Nom. Thickness Nom. Diameter PVC - Polyvinyl Chloride 0.048 in (1.2 mm) 1.244 in (31.60 mm) Overall Cable Diameter (Nominal): 1.244 in (31.60 mm)

Electrical Characteristics

Element Nom. Conductor DCR Max. Current Conductor(s) 1.04 Ohm/1000ft 28 Amps per Conductor at 30ºC Ground Wire 1.68 Ohm/1000ft (5.51 Ohm/km) 30 Amps per Conductor at 30ºC Voltage Voltage Rating

600 V (TECK 90)

Mechanical Characteristics Temperature UL Temperature Operating Installation 90°C -40°C To +90°C -25°C To +90°C Bend Radius Stationary Min. Installation Min. 9.952 in (252.8 mm) 9.952 in (252.8 mm) Max. Pull Tension: 2068.4 lbs (938.21 kg) Bulk Cable Weight: 898 lbs/1000ft Standards and Compliance Environmental Suitability: Indoor, Outdoor, Sunlight Resistance, UV Resistance CEC / C(UL) Compliance: TECK 90, HL European Directive Compliance: EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) APAC Compliance: China RoHS II (GB/T 26572-2011) History Update and Revision: Revision Number: 0.164 Revision Date: 12-22-2023 © 2024 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "ASIS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden's knowledge, information and belief at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product.