NT21-ST121-E OMRON | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 5

Technical content

FA Systems Division H.Q.

66 Matsumoto

Mishima-city, Shizuoka 411-8511 Japan Tel: (81)55-977-9181 Fax: (81)55-977-9045 Authorized Distributor: Note: Specifications subject to change without notice. Cat. No. V071-E1-02 Printed in Japan 1003-0.5M Regional Headquarters OMRON EUROPE B.V. Wegalaan 67-69, NL-2132 JD Hoofddorp The Netherlands OMRON ELECTRONICS LLC

1 East Commerce Drive, Schaumburg, IL 60173

U.S.A. OMRON ASIA PACIFIC PTE. LTD.

83 Clemenceau Avenue,

#11-01, UE Square, Singapore 239920 Tel: (65)6835-3011/Fax: (65)6835-2711 Note: Do not use this document to operate the Unit. Programmable Terminals NT11 NT21 NT11/NT21 This catalog mainly provides information that is necessary for selecting suitable models, and does not contain precautions for correct use. Always read the precautions and other required information provided in product operation manuals before using the product. The application examples provided in this catalog are for reference only. Check functions and safety of the equipment before use. Never use the products for any application requiring special safety requirements, such as nuclear energy control systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, or other application involving serious risk to life or property, without ensuring that the system as a whole has been designed to address the risks, and that the OMRON products are properly rated and installed for the intended use within the overall equipment or system. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS, OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.

Shares I/O comment data with CX-Programmer Symbol Manager previews Copy image library window data Individual editing of grouped parts Windows XP supported Concentrated functionality Effective display area 117 x 63 mm Up to 3,999 screens Supports RS-232C/422 Adapter (connector) Bar Code Reader function Programming Console function NT20S/NT31 data compatibility Mathematical functions Upgraded NT Support Tool version (-EV4.7) 31 functional parts Recipes Alarm lists/histories Image library Trend graphs Analog meters High-speed NT Links Memory Link Two RS-232C ports Supports Memory Units Compact Size, High Performance Superb functionality with a compact screen size Long-lived Backlight Simplified Ladder Programming Password Screens Conforms to NEMA4 and IP65 High-speed Host Link Full Area Access to CS1/CJ1 Fully Compatible with NT11S NT11 NT21 Display History Record Helps in Analysis of Machine Faults When the display history record function is set as a screen attribute, the time, the screen number, and a comment are recorded in the terminal's memory every time the relevant screen is displayed. This display history can be printed by issuing a print instruction from the host, and is useful for machine fault analysis. Long-lived Backlight Since LEDs are used for the backlight, it is very long-lived and rarely needs to be changed. Password Screens for Security Password screens cannot be accessed unless the correct password is entered. This means that the operations that can be performed can be restricted according to the operator. Bar Graphs can be Displayed Bar graph displays allow the progress of processes to be checked at a glance. (The bars are oriented horizontally.) Key Titles can be Marked on the Function Key Sheet Key titles can be marked on the function key sheet in accordance with the applications of the keys: the sheet can be taken out from the side face of the terminal. The front panel of the terminal has a water-withstanding construction. Example key titles: Integral Numeric Key Pad The display, numeric keys, and function keys are all integrated into the front panel, which is convenient for designers. The key layout is ergonomically designed for ease of use. Printout of Production Status Data such as the production status and production results can be printed out, leaving a record on paper which can be used as a daily report. (The NT11S has a printer port. One screen only is printed.) High-speed Host Link Up to 115,200 bps supported between CS1/CJ1 PLCs. Screen Line 1 Line 2 Line 3 Plan 200 150 350 Prod. 200 140 350 RUN AUT MAN. STOP Example printout No. Screen Comment LINE ERROR MOTOR ERROR COMPRESSER ERROR MOTOR ERROR Screen No Time 11/01-10:00 11/07-15:33 11/11-13:56 11/14-09:12 Advantages From the Standpoint of Maintenance, Advantages From the Standpoint of Maintenance, NTNT11 NT11

Small Size, Large Screen The LCD screen is larger than the OMRON NT20S (increased from 256 x 128 dots to 260 x 140 dots), but the external dimensions and panel cut-out size are the same. Two RS-232C Ports Two RS-232C ports in the NT21 (compared with one in the NT20S) enable simultaneous connection of a PLC, Bar Code Reader, and NT Support Tool (connectable to serial port A only). Plenty of Capacity for Saving Graphic Screens With 512 Kbytes of memory capacity, there is more than ample space for storing screen data. Versatile Communications In addition to the Host Link and 1:1 NT Link communications, the NT21 supports high-speed 1:N NT Links and Memory Link communications. Versatile I/O and Large-capacity Screen Memory in a Space-saving Size Versatile I/O and Large-capacity Screen Memory in a Space-saving Size Upgraded NT Support Tool Version (- EV4.7) Upgraded NT Support Tool Version (- EV4.7) Function Support Equivalent to That of a Mid-size Operator Interface Function Support Equivalent to That of a Mid-size Operator Interface Highly Reliable HardwareHighly Reliable Hardware Larger screen NT Support Tool (screen creation/transfer) RS-232C NT21 RS-232C PLC (host) High-speed 1:N NT Links RS-232C Memory Link Personal computer (host) RS-232C PLC (host) Abundant graphic screen storage NT21NT21 Long, Maintenance-Free Life (50,000 h) The NT21 conforms to the EC Directives, as well as UL, cULus (Class 1 Div2), and C-Tick. The front panel has an enclosure rating equivalent to IP65F. Conforms to International Standards System and screen data can be stored in NT21 Flash Memory. Recipe Function *C500-BAT08 Battery (sold separately) required. Alarm List/History(*) Parts tables on the PT screen can be used to set multiple word data in records, which can then be written to the PLC by a simple PT touch panel operation. For example, the setting parameters for separate models can be edited on the PT, then written to or read from the PLC. An alarm message can be displayed in response to PLC bit status, and the content and time of the message can be stored as an alarm history. RS-232C PLC (host) The NT21 is equipped with many of the same functions as the SYSMAC PLC Programming Console. Programming Console Function Up to 256 math equations can be stored in the PT processing table to allow automatic PT processing, and the results can be written to the numeral memory table or other destinations. This makes it possible to perform scaling and other mathematical operations automatically in the PT. Mathematical Functions NT21 Programming Console function I/O comments in the I/O tables of the CX-Programmer can be used directly. Enhanced Editing Functions I/O comments for designated PLC addresses can be used directly, with no need for CSV file conversion. NT Support ToolCX-Programmer CX-Server I/O comment data Symbol Manager previews are supported. This function makes it possible to preview symbols (parts created from graphics data). Parts can be copied by drag & drop operations of image, library, or mark data. The properties of grouped parts can be edited without having to ungroup them. Because NT20S and NT31 screen data is compatible with the NT21, existing software assets can be utilized to greatly reduce the number of design steps. Note: Some data revisions may be required due to size differences. Windows XP supported. ModelNT21 NT11NT11SNT20S Basic performance Display elements Special functions Communications Dimensions190 x 110 x 53.5 mm (H x W x D) 218 x 113 x 38.2 mm (H x W x D) Resolution Effective display area 260 x 140 dots (5.2 inches) 256 x 128 dots (4.91 inches) 117 x 63 mm112 x 56 mm 500 Display colorBlack & white (with blue mode) Panel cut-out size (W x H)178.5 x 100.5 mm Max. number of registered screens3,999

96 KB Screen data capacity512 KB

Rectangles, polygons, arcs, sectors Painting out Image/library displays256 positions per screen Analog meters50 positions per screen None Trend graphs1 position per screen None Broken line graphs1 position per screen None Alarm lists/histories4 positions per screen None Recipes1 position per screen None InterlocksSupported None Mathematical Function Math equations: Max. 256 (arithmetic functions, logic operations, bit manipulations, comparison operations) None Programming Console function (Executes functions equivalent to C200H-PR027 and CS1 Programming Consoles.) None High-quality fontSupported None Memory UnitSupported 10,000 hours min. Backlight service life50,000 hours min. Via RS-232C communications Memory LinksSupported None Bar Code Reader connectionSupported 9,600/19,200 Host Link Speed9,600/19,200 None Supported Supported Comparison with the NT11 160 x 64 dots (4.24 inches) 100 x 40 mm Black & white (with Yellow mode) 204.2 x 99.8 mm 250 32 KB Numeric Keys, Cursor Keys, Function Keys None None None None None None None None None None None None (Emergency transfer mode)* None None None 50,000 hours min.10,000 hours min. Up to 115,2009,600/19,200 NT2NT21 NT21 *Emergency transfer mode: When power to the NT11 is turned ON with DIP switch pin 3 turned ON, data transfer mode can be entered directly without any other operation.

NT21 General Specifications ItemSpecification Power consumption Noise resistanceConforms to IEC61000-4-4. Power supply line: 2 kV Vibration resistance2 acceleration, Shock resistancePeak acceleration 15 G, Ambient operating temperature˚ Ambient operating humidity ˚C) Dimensions190 x 110 x 53.5 mm (W x H x D) (thickness inside panel: 49.0 mm) Enclosure ratingsFront panel operating section: Equivalent to IP65F, NEMA 4.* Weight0.6 kg max. Display Capacity ItemSpecification Display elements Screen types Screen attributes Fixed displays Graphics Marks (Graphics: rectangles, circles, Character string displays 256 positions per screen, max. 1,024 display elements for overlapping screens Graph displays50 positions per screen, capable of displaying signs and percentages Analog meters50 positions per screen, capable of displaying signs and percentages Trend graphsOne frame per screen, 50 items per frame (8 items max. for data logging) Broken line graphsOne frame per screen, 256 items per frame, 260 points per item Lamps256 positions per screen Image library images256 positions per screen Touch switches 256 positions per screen 26 positions per screen 256 positions per screen RecipesOne position per screen Normal screensDisplays screens registered as normal A maximum of eight screens can be displayed overlapping each other. WindowsUp to three window screens can be displayed. Display history screensOrder of occurrence (1,024 screens max.), order of frequency (255 times max.) System startup screen Displayed when powering ON (or resetting ) the PT, and when switching to RUN mode. Programming Console screen Max. number of Screen number Emulates PLC Programming Console functions, capable of being called from RUN mode. Buzzer, display history, normal background colors, backlight mode, local windows Number of screens Screen registration method Saving screen data 3,999 By transferring screen data from the NT Support Tool to the PT via serial communications By mounting the Memory Unit and downloading (automatic/manual transfer) data to the PT Flash memory (PT internal image memory) 0: No display 1 to 3999: User registered screens (normal, overlapping, windows) 9000: System startup screen 9001: Display history screens, order of occurrence 9002: Display history screens, order of frequency 9020: Programming Console screen 9999: Return to previous screen designation Total of 256 positions for both numerical and thumbwheel settings With overlapping screens, the total is 524,280 per screen Display Specifications ItemSpecification Display panel Backlight (white cold cathode tube) Monochrome STN LCD Display device 260 dots horizontally x 140 dots vertically Number of dots (resolution) 117 mm horizontally x 63 mm vertically Effective display area ˚˚ Viewing angle Black & white (with blue mode) Display color 50,000 hours min. (until contrast reduced to 50%) Service life Can be set to turn OFF in 1 to 255 min or to remain ON with screen saver 50,000 hours min. (at room temperature, until brightness is reduced to 50%) Automatic turn-OFF Service life Non-replaceable Replacement Panel Specifications ItemSpecification Touch panel 91 (13 horizontally x 7 vertically) Number of switches Pressure-sensitive Input 1 N max. 1 million operations min. Life expectancy External Interface Specifications Communications methodSerial port ASerial port B PLC NT Support ToolSupported Supported Supported Supported Supported Supported Supported Supported Supported Supported Supported SupportedNot supported Not supported Host Link 1:1 NT Link 1:N NT Links NT Link, PT Programming Console function Memory Links SBC/personal computer Bar Code Reader *Connection via RS-422A/485 is possible using the NS-AL002 RS-232C/422A Adapter (connector), which can be connected only to serial port B. (RS-485 connections must use 1:N NT Links.) *Usage may not be possible in places where the unit would be exposed to oil for long periods. NT21 Standard Models Product NT21 Programmable Terminal Support Tooll Cables Options Monochrome STN Windows 95, 98, Me, NT, or 2000 For screen transfer Reflection Protective Sheets Chemical-resistive Cover For PLC connection PT: 9-pin PLC: 9-pin NT21-ST121-E Frame color: beige CD-ROM Cable length: 2 m NT-ZJCAT1-EV4 XW2Z-S002 XW2Z-200T PT: 9-pin PLC: 25-pin Cable length: 2 m Cable length: 5 m XW2Z-200S XW2Z-500S PT: 9-pin PLC: Mini-peripheralCable length: 5 mXW2Z-500T-2 NT20M-KBA04 Battery NT20S-KBA01 Memory Unit Display area only (5 sheets) Silicon cover For alarm lists/histories For screen and system data transfer C500-BAT08 RS-232C/422A Adapter Connector Kit NT-MF161 NS-AL002 XM2S-0911-S003 SpecificationModel number Dimensions ±15% NT11 General Specifications ItemSpecification Allowable power Noise resistanceConforms to IEC61000-4-4, 2K (power lines) Vibration resistance10 to 57 Hz with 0.075 mm amplitude and 57 to 150 Hz with 9.8 m/s2 acceleration for 30 min in each of X, Y, and Z directions Shock resistance147 m/s2 3 times in each of X, Y, and Z directions Ambient operating temperature0 to +50˚C Ambient operating humidity35 to 85% RH (with no condensation) Operating environmentNo corrosive gasses. Storage temperature–20 to +70˚C (with no freezing) Enclosure ratingsFront panel: Equivalent to IP65, NEMA4 Weight1.0 kg max.

24 VDC

15.5 19.5 4.539 min. Panel thickness: 1.6 to 4.8 mm 178 190 142 52.5 110 53.5100 122 Special Features ItemSpecification Printing function Maintenance functions

  • Simple communications confirmation. Printing of display history data Printing of daily reports (printing format registered by the users) Display Capacity ItemSpecification Display characters Number of characters displayedNormal-size: 20 horizontally x 4 lines vertically max. Double width Display elements 8 positions per screen 8 positions per screen 4 positions per screen Screen attributes Screen typesNormal screen: Displays screen registered as normal. Screen saving methodSaved to flash memory: 32 KB (downloading method) Max. number of registered screens250 Screen registration method Transfer screen data created using an IBM PC/AT personal computer to the PT. Normal characters (8 x 16 dots): Alphanumerics and symbols Marks (8 x 16 dots): User-defined, 64 max. Display/Panel Specifications ItemSpecification Display screen Indicators• RUN indicator (Green LED): Lit during operation Switch• Life expectancy: 1 million operations minimum Dot matrix of STN liquid
  • Number of dots: 160 x 64
  • Effective display area: 100 x 40 mm
  • Life expectancy: 50,000 hours minimum
  • View angle (left/right direction): ±20˚ Backlight
  • LED
  • Life expectancy: 50,000 hours minimum
  • Automatic turn-off: can be set to turn off in 10 minutes or 1 hour, or to remain on. Note: In order to improve the performance of displays, liquid crystal devices may be ch Note: In order to improve the performance of displays, liquid crystal devices may be changed without notice. and a flash ROM that downloads the system program. *Connecting cables with the PLC and NTST are the same as those for the NT21. Please refer to the next page. Character string displays Numeral Graph Numeral settings Order of frequency, 256 screens Ensures security: screens for which this attribute is set can only be displayed if the correct password is input. Four items per screen history screen Menu screen NT11 Product Configurations ProductModel Specification Terminal* Support Software Outside Dimensions Panel Plate thickness: 1.6 to 4.8 mm Rear face Recommended panel cutout: Host link direct connection, NT link method Ten-key type (frame color: beige)NT11-SF121-EV1 Ten-key type (frame color: black)NT11-SF121B-EV1 CD-ROM (for Windows 95, 98, Me, XP, NT, 2000)NT-ZJCAT1-EV4 NTNT11NT11NT2NT21 NT21 80.5 38.2 218 203 204.2 3 11398 8 98. +0.5 +0.5 Function key sheet 10 sheets for replacement for beige 10 sheets for replacement for black NT11-CKF01 NT11-CKF01B

2007.3 OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved. In the interest of product improvement, specifications are subject to change without notice. Cat. No. V071-E1-02