Features
- Plug into mounting boards for C4 Series modules
- AC Inputs (Yellow Case)
- DC Inputs (White Case)
- 4kV Optical isolation
- Replaceable 2 AG Type Fuse
- Industry standard packaging
- Built-in LED Status Indicator SPECIFICATIONS 1 Part Number C4OAC C4OACA C4OACR C4OACAR C4ODC C4ODCA Input Nominal Voltage [VDC] 4-32 4-32 4-32 4-32 4-32 4-32 Maximum Voltage [VDC] 32 32 32 32 32 32 Maximum Current [mA ] 2, 3 22 22 22 22 16 16 Resistance [Ohms] Regulated Input Regulated Input Regulated Input Regulated Input Regulated Input Regulated Input Output Nominal Line Voltage 120 VAC 240 VAC 120 VAC 240 VAC 5-48 VDC 5-150 VDC Minimum Line Voltage 12 VAC 12 VAC 12 VAC 12 VAC 5.0 VDC 3 VDC Maximum Line Voltage 140 VAC 280 VAC 140 VAC 280 VAC 60 VDC 250 VDC Max Off-State Voltage 4 600 Vpeak 600 Vpeak 600 Vpeak 600 Vpeak 60 VDC 250 VDC Max Off-State Leakage 5 0.1mArms 0.1mArms 0.1mArms 0.1mArms 10 uA 10 uA Static Off-State dv/dt 6 200 V/usec 200 V/usec 200 V/usec 200 V/usec n/a n/a Minimum On-State Current 50 mArms 50 mArms 50 mArms 50 mArms 10 mA 10 mA Max Surge Current 8 100 Apeak 100 Apeak 100 Apeak 100 Apeak 5.0 Apeak 5.0 Apeak HP Rating 1/4 1/4 1/4 1/4 n/a n/a Input/Output Isolation Voltage 11 4000 Vrms 4000 Vrms 4000 Vrms 4000 Vrms 4000 Vrms 4000 Vrms Input/Output Capacitance 4 pF 4 pF 4 pF 4 pF 4 pF 4 pF Operating Temperature Range -30 to 80°C -30 to 80°C -30 to 80°C -30 to 80°C -30 to 80°C -30 to 80°C Storage Temperature Range -40 to 100°C -40 to 100°C -40 to 100°C -40 to 100°C -40 to 100°C -40 to 100°C Line Frequency Range 47 to 63 Hz 47 to 63 Hz 47 to 63 Hz 47 to 63 Hz DC DC
www.sensata.com Page 2 Copyright © 2018 Sensata Technologies, Inc. EQUIVALENT CIRCUIT DIAGRAM / MECHANICAL SPECIFICATIONS
www.sensata.com CONTACT US Americas +1 (877) 502 5500 sales.crydom@sensata.com Europe, Middle East & Africa +44 (1202) 416170 ssr-info.eu@sensata.com Asia Pacific sales.isasia@list.sensata.com China +86 (21) 2306 1500 Japan +81 (45) 277 7117 Korea +82 (31) 601 2004 India +91 (80) 67920890 Rest of Asia +886 (2) 27602006 ext 2808 Copyright © 2018 Sensata Technologies, Inc. Sensata Technologies, Inc. (“Sensata”) data sheets are solely intended to assist designers (“Buyers”) who are developing systems that incorporate Sensata products (also referred to herein as “components”). Buyer understands and agrees that Buyer remains responsible for using its independent analysis, evaluation and judgment in designing Buyer’s systems and products. Sensata data sheets have been created using standard laboratory conditions and engineering practices. Sensata has not conducted any testing other than that specifically described in the published documentation for a particular data sheet. Sensata may make corrections, enhancements, improvements and other changes to its data sheets or components without notice. Buyers are authorized to use Sensata data sheets with the Sensata component(s) identified in each particular data sheet. HOWEVER, NO OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE TO ANY OTHER SENSATA INTELLECTUAL PROPERTY RIGHT, AND NO LICENSE TO ANY THIRD PARTY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT, IS GRANTED HEREIN. SENSATA DATA SHEETS ARE PROVIDED “AS IS”. SENSATA MAKES NO WARRANTIES OR REPRESENTATIONS WITH REGARD TO THE DATA SHEETS OR USE OF THE DATA SHEETS, EXPRESS, IMPLIED OR STATUTORY , INCLUDING ACCURACY OR COMPLETENESS. SENSATA DISCLAIMS ANY WARRANTY OF TITLE AND ANY IMPLIED WARRANTIES OF MERCHANTABILITY , FITNESS FOR A PARTICULAR PURPOSE, QUIET ENJOYMENT, QUIET POSSESSION, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL PROPERTY RIGHTS WITH REGARD TO SENSATA DATA SHEETS OR USE THEREOF. All products are sold subject to Sensata’s terms and conditions of sale supplied at www.sensata.com SENSATA ASSUMES NO LIABILITY FOR APPLICATIONS ASSISTANCE OR THE DESIGN OF BUYERS’ PRODUCTS. BUYER ACKNOWLEDGES AND AGREES THAT IT IS SOLELY RESPONSIBLE FOR COMPLIANCE WITH ALL LEGAL, REGULATORY AND SAFETY-RELATED REQUIREMENTS CONCERNING ITS PRODUCTS, AND ANY USE OF SENSATA COMPONENTS IN ITS APPLICATIONS, NOTWITHSTANDING ANY APPLICATIONS-RELATED INFORMATION OR SUPPORT THAT MAY BE PROVIDED BY SENSATA. Mailing Address: Sensata Technologies, Inc., 529 Pleasant Street, Attleboro, MA 02703, USA. Rev. 03/29/18 ECN 20395 FDE-07-01 Rev. B GENERAL NOTES (1) Specifications apply to an ambient temperature of -30 to 80 °C unless otherwise noted. (2) At 32 VDC typical. (3) 13 ma at 5 VDC for AC output modules only. (4) Maximum 1 minute duration. (5) At maximum rated line voltage, TA=80°C. (6) Minimum DV/DT per EIA/NARM RS443, method RS397, DV/DT ratings do not apply to DC output models. (7) Without any external heat sink in still air, TA=45°C, at 40°C derate 40 mA/°C to 80°C. (8) At 25°C for 1 second maximum duration: 1 AC cycle for AC modules, 1 second for DC modules. (9) At peak rated current. (10) Before zero voltage, Vin=4V AC modules only based on 60Hz. Vin=15V for DC modules. (11) For 1 second maximum duration TA= 25°C. WARNINGS AGENCY APPROVALS & CERTIFICATIONS E46203 38595 RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE
- The product’s side panels may be hot, allow the product to cool before touching
- Follow proper mounting instructions including torque values
- Do not allow liquids or foreign objects to enter this product Failure to follow these instructions can result in serious injury, or equipment damage. HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH
- Disconnect all power before installing or working with this equipment
- Verify all connections and replace all covers before turning on power Failure to follow these instructions will result in death or serious injury.