Features
- Plug into mounting boards for C4 Series modules
- AC Inputs (Yellow Case)
- DC Inputs (White Case)
- 4kV Optical isolation
- Open-collector Output
- Industry standard packaging
- Built-in LED Status Indicator SPECIFICATIONS 1 Part Number C4IAC C4IACA C4IDC Input Voltage Range 90-140 VAC 180-280 VAC 10-32 VDC Maximum Current [mA] 2 14 5 20 Resistance [Ohms] 3, 4 22 k 75 k 2 k Drop-out Current [mA] 5 3 1 1.5 Allowable Voltage for No Output [VAC/VDC] 6 50 50 3.0 Allowable Current for No Output [mA] 6 2.5 0.7 1.0 Output Maximum Logic Supply Voltage[VDC] 30 30 30 Maximum Output Voltage Drop [VDC] 7 0.2 0.2 0.2 Minimum Logic Supply Voltage [VDC] 4.5 4.5 4.5 Logic Supply Voltage Range [VDC] 4.5-30 4.5-30 4.5-30 Maximum Current [mA] 8 50 50 50 Maximum Logic Supply Current [mA] 9 25.0 25.0 25.0 Maximum Logic Supply Leakage Current [μA] 10 10.0 10.0 10.0 Maximum Supply Idle Current [μA] 11 10.0 10.0 10.0 Maximum Turn-On Time [msec] 12 20 20 5.0 Maximum Turn-Off Time [msec] 12 20 20 5.0
www.sensata.com Page 2 Copyright © 2018 Sensata Technologies, Inc. GENERAL SPECIFICATIONS Description Parameters Input/Output Isolation Voltage 13 4000 Vrms Input/Output Capacitance 8 pF Operating Temperature Range -30ºC to 80ºC Storage Temperature Range -40ºC to 100ºC Weight 1.1 oz. (31.2g) EQUIVALENT CIRCUIT DIAGRAM / MECHANICAL SPECIFICATIONS SPECIFICATIONS 1 Part Number C4IDCB C4IDCG C4IDCK Input Voltage Range 4-16 VDC 35-60 VDC 2.5-16 VDC Maximum Current [mA] 2 40 10 60 Resistance [Ohms] 3, 4 400 10 k 300 Drop-out Current [mA] 5 2 1 2 Allowable Voltage for No Output [VAC/VDC] 6 1 7 1 Allowable Current for No Output [mA] 6 0.7 0.7 0.2 Output Maximum Logic Supply Voltage[VDC] 30 30 30 Maximum Output Voltage Drop [VDC] 7 0.2 0.2 0.2 Minimum Logic Supply Voltage [VDC] 4.5 4.5 4.5 Logic Supply Voltage Range [VDC] 4.5-30 4.5-30 4.5-30 Maximum Current [mA] 8 50 50 50 Maximum Logic Supply Current [mA] 9 25.0 25.0 25.0 Maximum Logic Supply Leakage Current [μA] 10 10.0 10.0 10.0 Maximum Supply Idle Current [μA] 11 10.0 10.0 10.0 Maximum Turn-On Time [msec] 12 0.05 10.0 0.025 Maximum Turn-Off Time [msec] 12 0.1 10.0 0.025
www.sensata.com CONTACT US Americas +1 (877) 502 5500 sales.crydom@sensata.com Europe, Middle East & Africa +44 (1202) 416170 ssr-info.eu@sensata.com Asia Pacific sales.isasia@list.sensata.com China +86 (21) 2306 1500 Japan +81 (45) 277 7117 Korea +82 (31) 601 2004 India +91 (80) 67920890 Rest of Asia +886 (2) 27602006 ext 2808 Copyright © 2018 Sensata Technologies, Inc. Sensata Technologies, Inc. (“Sensata”) data sheets are solely intended to assist designers (“Buyers”) who are developing systems that incorporate Sensata products (also referred to herein as “components”). Buyer understands and agrees that Buyer remains responsible for using its independent analysis, evaluation and judgment in designing Buyer’s systems and products. Sensata data sheets have been created using standard laboratory conditions and engineering practices. Sensata has not conducted any testing other than that specifically described in the published documentation for a particular data sheet. Sensata may make corrections, enhancements, improvements and other changes to its data sheets or components without notice. Buyers are authorized to use Sensata data sheets with the Sensata component(s) identified in each particular data sheet. HOWEVER, NO OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE TO ANY OTHER SENSATA INTELLECTUAL PROPERTY RIGHT, AND NO LICENSE TO ANY THIRD PARTY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT, IS GRANTED HEREIN. SENSATA DATA SHEETS ARE PROVIDED “AS IS”. SENSATA MAKES NO WARRANTIES OR REPRESENTATIONS WITH REGARD TO THE DATA SHEETS OR USE OF THE DATA SHEETS, EXPRESS, IMPLIED OR STATUTORY , INCLUDING ACCURACY OR COMPLETENESS. SENSATA DISCLAIMS ANY WARRANTY OF TITLE AND ANY IMPLIED WARRANTIES OF MERCHANTABILITY , FITNESS FOR A PARTICULAR PURPOSE, QUIET ENJOYMENT, QUIET POSSESSION, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL PROPERTY RIGHTS WITH REGARD TO SENSATA DATA SHEETS OR USE THEREOF. All products are sold subject to Sensata’s terms and conditions of sale supplied at www.sensata.com SENSATA ASSUMES NO LIABILITY FOR APPLICATIONS ASSISTANCE OR THE DESIGN OF BUYERS’ PRODUCTS. BUYER ACKNOWLEDGES AND AGREES THAT IT IS SOLELY RESPONSIBLE FOR COMPLIANCE WITH ALL LEGAL, REGULATORY AND SAFETY-RELATED REQUIREMENTS CONCERNING ITS PRODUCTS, AND ANY USE OF SENSATA COMPONENTS IN ITS APPLICATIONS, NOTWITHSTANDING ANY APPLICATIONS-RELATED INFORMATION OR SUPPORT THAT MAY BE PROVIDED BY SENSATA. Mailing Address: Sensata Technologies, Inc., 529 Pleasant Street, Attleboro, MA 02703, USA. Rev. 03/29/18 ECN 20395 FDE-07-01 Rev. B GENERAL NOTES (1) Specifications apply to an ambient temperature of -30 to 80 °C unless otherwise noted. (2) Measured at maximum specified input voltage, 25°C. (3) Resistance values for C4IAC modules are effective impedance values at 25 °C. (4) Resistance values are +/-10% at 25 °C. (5) Defined as the maximum current allowed through the module’s input to guarantee that the output will switch from “on” to “off”. Higher currents may result in the output remaining in the “on” state. (6) Defined as the maximum voltage/current allowed through the module’s input that will not switch the module’s output state from “off “ to “on”. (7) At maximum output current and 25°C (8) Maximum allowable sinking current through open collector output transistor (9) At maximum logic supply voltage and 25°C. (10) At maximum output voltage and 25°C. (11) At maximum specified logic voltage and 25°C. (12) At 15 VDC logic, 30 VDC output, 50 mA, 25°Cand nominal input voltage. (13) At 25°C for 1 second maximum duration. WARNINGS RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE
- The product’s side panels may be hot, allow the product to cool before touching
- Follow proper mounting instructions including torque values
- Do not allow liquids or foreign objects to enter this product Failure to follow these instructions can result in serious injury, or equipment damage. HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH
- Disconnect all power before installing or working with this equipment
- Verify all connections and replace all covers before turning on power Failure to follow these instructions will result in death or serious injury. AGENCY APPROVALS & CERTIFICATIONS E46203 38595