Power Entry Modules with Line Filter C20F www.schurter.com/pg06 EMC Products IEC Appliance Inlet C20 with Filter, Front or Rear Side Mounting Screw-on mounting from front side Snap-in mounting from front side Screw-on mounting from rear side with wires (stranded) Standard- or Medical-Filter C20 70° C

Description

  • Panel Mount: Screw-on version from front or rear side, snap-in version from front side - 2 Functions: Appliance Inlet Protection class I, Line filter in standard and medical version - Solder, quick connect or wires (stranded) Approvals - VDE Certificate Number: 104884 - UL File Number: E72928 Characteristics - Compact design with optimal shielding Suitable for assembly in metal plated plastic housings - Version with class X1 and X2 (standard version) capacitors - Universal line filter for standard applications Designed for standard and medical applications - Qualified for use in equipment according IEC/EN 60950 Other versions on request - 16A according to UL - Capacity CX 330 nF References Weblinks pdf, html, General Product Information, Approvals, RoHS, CHINA-RoHS, Mating Connectors, e-Store, SCHURTER-Stock-Check, Distributor- Stock-Check, Accessories, Wire Harness Newly available variants corresponding to V-Lock mating cordset. The connector is equipped with a notch intended for use with the latching cordset. The cord latching system prevents against accidental removal of the cordset. T echnical Data Ratings IEC 16 A @ Ta 40 °C / 250 VAC; 50 Hz Ratings UL/CSA 20 A @ Ta 40 °C / 250 VAC; 60 Hz Leakage Current standard < 0.5 mA (250 V / 60 Hz) medical < 5 µA (250 V / 60 Hz) Dielectric Strength > 1.7 kVDC between L-N (Cy2) > 2.7 kVDC between L/N-PE (Cy2) Test voltage (2 sec) Impulse Withstand Voltage > 2.5 kV between L-N (CX2) > 4 kV between L-N (CX1) > 5 kV between L/N-PE (Cy2) voltage (1.2/50 μs) Allowable Operation Temp. -25 °C to 85 °C Climatic Category 25/085/21 acc. to IEC 60068-1 Degree of Protection from front side IP 40 acc. to IEC 60529 Protection Class Suitable for appliances with protection class 1 acc. to IEC 61140 Terminal Solder, quick connect or wires (stran- ded) Panel Thickness s Screw: max 8 mm Mounting screw torque max 0.5 Nm Snap-in: 1 mm to 3 mm Material: Housing Thermoplastic, black, UL 94V-0 Appliance-Inlet/-Outlet C20 acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for cold conditions) pin-temperature 70 °C, 16 A, Protection Class 1 Line Filter Standard and Medical Version, IEC 60939, IEC 60601-1, UL 1283, UL 544, EN 133 200, CSA C22.2 no. 8 Technical details MTBF > 3'000'000 h acc. to MIL-HB-217 F

Power Entry Modules with Line FilterC20F www.schurter.com/pg06 EMC Products Dimensions 78.8 mm Screw-on mounting from front side 78.8 64.6530 3.85 26.8 3.4 ø 6x80° 33.90 x 25.90 9.4R6 10.3 34.8 3.5/M3 ±0.15 +0.20 +0.20 6.3 x 0.8* * Solder terminal: identical outer dimensions Screw-on mounting from rear side with metal flange 78.8 64.6528 3.85 28.3 M 3 33.90 x 25.90 9.4R 6 10.3 max. R 0.5 36.4 3.5 ±0.15 +0.20 +0.20 R 0.5 Snap-in mounting from front side 78.8 64.6530 3.85 26.3 33.90 x 25.85 9.4 10.3 34.8+0.20 +0.20 T echnical Data of Filter-Components Rated Current [A] Filter-Type Inductances L [mH] Capacitance CX [nF] Capacitance CY [nF] R [MΩ] 16 Standard Version 2 x 0.3 100 2.2 1 16 Medical Version (M5) 2 x 0.3 100 - 1 16 Medical Version (M80) 2 x 0.3 100 0.47 1

Power Entry Modules with Line Filter C20F www.schurter.com/pg06 EMC Products Diagrams Standard or medical version (M80) 1) Line 2) Load Medical version 1) Line 2) Load Attenuation Loss - - - - differential mode _____ common mode Standard version 20 A Medical version (M5) 20 A Variants Rated Current IEC [A] Rated Current UL [A] Filter-Type Panel mounting Mounting side T erminal Capacitor Order Number 16 20 Standard Version Screw Front-Side Quick connect terminals 6.3 x 0.8 mm X2 C20F.0101 16 20 Standard Version Screw Front-Side Quick connect terminals 6.3 x 0.8 mm X2 C20F.0101.21 16 20 Standard Version Screw Front-Side Quick connect terminals 6.3 x 0.8 mm X1 C20F.0103 16 20 Standard Version Screw Front-Side Solder terminals X2 C20F.0001 16 20 Standard Version Screw Front-Side Solder terminals X2 C20F.0001.21 16 20 Standard Version Screw Front-Side Solder terminals X1 C20F.0003 16 20 Standard Version Screw Rear-Side Flexible wire AWG14 X2 C20F.0221 16 20 Standard Version Screw Rear-Side Flexible wire AWG14 X1 C20F.0223 16 20 Standard Version Screw Rear-Side Quick connect terminals 6.3 x 0.8 mm X2 C20F.0121 16 20 Standard Version Screw Rear-Side Quick connect terminals 6.3 x 0.8 mm X1 C20F.0123 16 20 Standard Version Screw Rear-Side Solder terminals X2 C20F.0021 16 20 Standard Version Screw Rear-Side Solder terminals X1 C20F.0023 16 20 Standard Version Snap-in Front-Side Quick connect terminals 6.3 x 0.8 mm X2 C20F.0111 16 20 Standard Version Snap-in Front-Side Quick connect terminals 6.3 x 0.8 mm X1 C20F.0113 16 20 Standard Version Snap-in Front-Side Solder terminals X2 C20F.0011 16 20 Standard Version Snap-in Front-Side Solder terminals X1 C20F.0013 16 20 Medical Version (M5) Screw Front-Side Quick connect terminals 6.3 x 0.8 mm X2 C20F.0102 16 20 Medical Version (M5) Screw Front-Side Quick connect terminals 6.3 x 0.8 mm X1 C20F.0104 16 20 Medical Version (M5) Screw Front-Side Solder terminals X2 C20F.0002 16 20 Medical Version (M5) Screw Front-Side Solder terminals X1 C20F.0004 16 20 Medical Version (M5) Screw Rear-Side Flexible wire AWG14 X2 C20F.0222 16 20 Medical Version (M5) Screw Rear-Side Flexible wire AWG14 X1 C20F.0224 16 20 Medical Version (M5) Screw Rear-Side Quick connect terminals 6.3 x 0.8 mm X2 C20F.0122 T echnical Data of Filter-Components Rated Current [A] Filter-Type Inductances L [mH] Capacitance CX [nF] Capacitance CY [nF] R [MΩ] 16 Standard Version 2 x 0.3 100 2.2 1 16 Medical Version (M5) 2 x 0.3 100 - 1 16 Medical Version (M80) 2 x 0.3 100 0.47 1

Power Entry Modules with Line FilterC20F www.schurter.com/pg06 EMC Products Rated Current IEC [A] Rated Current UL [A] Filter-Type Panel mounting Mounting side T erminal Capacitor Order Number 16 20 Medical Version (M5) Screw Rear-Side Quick connect terminals 6.3 x 0.8 mm X1 C20F.0124 16 20 Medical Version (M5) Screw Rear-Side Solder terminals X2 C20F.0022 16 20 Medical Version (M5) Screw Rear-Side Solder terminals X1 C20F.0024 16 20 Medical Version (M5) Snap-in Front-Side Quick connect terminals 6.3 x 0.8 mm X2 C20F.0112 16 20 Medical Version (M5) Snap-in Front-Side Quick connect terminals 6.3 x 0.8 mm X1 C20F.0114 16 20 Medical Version (M5) Snap-in Front-Side Solder terminals X2 C20F.0012 16 20 Medical Version (M5) Snap-in Front-Side Solder terminals X1 C20F.0014 Wire lenght: 150 mm Suffix "21" corresponds to the version with V-Lock mating cordset. The connector is equipped with a notch intended for use with the latching cordset. The cord latching sy- stem prevents against accidental removal of the cordset. Available only for screw-on versions. Packaging unit 20 Pcs Accessories 0859.0047 Wire Harness Wire harness for SCHURTER products Cord retaining kits Cord retaining strain relief Countersunk, K 4700.0010 Flat head, L 4700.0011 Mating Outlets/Connectors Category / Description ConnectorOverview complete IEC Connector C19, Rewireable, Straight 0104 IEC Connector C19, Rewireable, Angled 1651 IEC Connector C19, Rewireable, Straight 1652 IEC Connector C19, Rewireable, Angled 4790 IEC Connector C19, Rewireable, Straight 4795 Connectorfurther types toC20F

Power Entry Modules with Line Filter C20F www.schurter.com/pg06 EMC Products Power CordOverview complete Power Cord with IEC Connector C19, Straight 1654 Power Cordfurther types toC20F Power Supply or Interconnection CordOverview complete Divers Power Supply and Interconnection Cords 16 A Kabelverbindung/16 A Power Supply or Interconnection Cordfurther types toC20F The specifications, descriptions and illustrations indicated in this document are based on current information. All content is subject to modifications and amendments.