C200HOD219 OMRON | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 13
Technical content
Screw Terminal Block Cables XW2Z Pre-terminated Cables Simplify Connection of Terminal Blocks to PLC Modules Reduce setup time with cables pre-terminated for the exact PLC module in use
1 No need to make custom connectors
1 Crimp hook-terminated cables connect
XW2B terminal blocks with PLC modules and input boards from any manufacturer
Ordering Information
3 CABLES
Appearance Applicable terminal block Cable length Part number XW2B-20G5 XW 2B 20G 4 0.5 m (1.64 ft) XW2Z-050A XW2B-20G4 XW 2B-20G 5-T 1 m (3.28 ft) XW2Z-100A XW 2B-20G 5-T XW2B-20G5-D 1.5 m (4.92 ft) XW2Z-150A Single cable for XW 2B 20G 5 D XW2B-20G5-IN16 2 m (6.56 ft) XW2Z-200ASinglec able for 32-point I/O modules 3 m (9.84 ft) XW2Z-300A32 ointI/O m odules 5 m (16.40 ft) XW2Z-500A XW2B-40G5 XW 2B 40G 4 0.5 m (1.64 ft) XW2Z-050B XW2B-40G4 1 m (3.28 ft) XW2Z-100B 1.5 m (4.92 ft) XW2Z-150B 2 m (6.56 ft) XW2Z-200B Single cable for 3 m (9.84 ft) XW2Z-300B Single cable for 32- and 64-point I/O modules 5 m (16.40 ft) XW2Z-500B XW2B-60G5 XW 2B 60G 4 1 m (3.28 ft) XW2Z-100H-1 XW2B-60G4 2 m (6.56 ft) XW2Z-200H-1 Single cable forC S1W 3 m (9.84 ft) XW2Z-300H-1 Singlec able forC S1W high-density I/O modules 5 m (16.40 ft) XW2Z-500H-1 XW2C-20G5-IN16 1 m (3.28 ft) and 0.75 m (2.46 ft) XW2Z-100D 1.5 m (4.92 ft) and 1.25 m (4.10 ft) XW2Z-150D 2 m (6.56 ft) and 1.75 m (5.74 ft) XW2Z-200D Bifurcated cable for 3 m (9.84 ft) and 2.75 m (9.02 ft) XW2Z-300DBifurcated cable for 32- and 64-point I/O modules 5 m (16.40 ft) and 4.75 m (15.58 ft) XW2Z-500D XW2B-40G5 and XW 2B 20G 5 1 m (3.28 ft) and 1 m (3.28 ft) XW2Z-100H-2 XW2B-20G5 2 m (6.56 ft) and 2 m (6.56 ft) XW2Z-200H-2 Bifurcated cable for 3 m (9.84 ft) and 3 m (6.56 ft) XW2Z-300H-2 Bifurcated cable for CS1W high- -density I/O modules 5 m (16.40 ft) and 5 m (16.40 ft) XW2Z-500H-2
Cables (continued) Appearance Applicable terminal block Cable length Part number Three XW2B-20G5 1 m (3.28 ft) and 0.75 m (2.45 ft) and 1 m (3.28 ft)XW2Z-100H-3 2 m (6.56 ft) and 1.75 m (5.74 ft) and 2 m (6.56 ft)XW2Z-200H-3 Three connectorcable for 3 m (9.84 ft) and 2.75 m (9.02 ft) and 3 m (9.84 ft)XW2Z-300H-3 Three-connector cable for 48- and 96-point I/O modules 5 m (16.40 ft) and 4.75 m (15.58 ft) and 5 m (16.40 ft)XW2Z-500H-3 XW2B-20G5 XW 2B 20G 4 1 m (3.28 ft) XW2Z-100F XW2B-20G4 1.5 m (4.92 ft) XW2Z-150F 2 m (6.56 ft) XW2Z-200F Single cable terminated 3 m (9.84 ft) XW2Z-300FSingle cable term inated with crimp hooks 5 m (16.40 ft) XW2Z-500F Specifications
3 RATINGS/CHARACTERISTICS
Rated current 1 A at 20°C( 6 8°F) Rated voltage 125 VAC Contact resistance 20 mΩ max. with 100 mA at 20 mV max. (See Note 1) Insulation resistance 100 MΩ min. at 500 VDC Dielectric strength 500 VAC for 1 minute with a current leakage of 1 mA max. (See Note 2) Enclosure rating IP00 Electrical protection Class 0 Ambient temperature Operating: - -25°Ct o8 0°C( - - 1 3°F to 176°F) Note: 1. The resistance indicated is the contact resistance of the connector. 2. The voltage indicated is the dielectric strength of the connector.
3 MATERIALS/FINISH
Item Parts Materials/Processing Connector XG4M-2030 XG 4M 4030 Housing Black PBT resin with glass (UL94V-0) XG4M-4030 XG 4M -6030 Cover g ( ) XG 4M -6030 Contact Contact-carrying portion: Phosphor bronze and nickel plated with 0.15-µm-thick gold Press-fit portion: Phosphor bronze and nickel plated with 2.0-µm-thick tin XG4T-2004 XG4T-4004 XG4T-6004 Strain relief Black PBT resin with glass (UL94V-0) FCN-367J024-AU/F FC N 367J040 AU /F Housing Black PBT resin (UL94V-0) FCN-367J040-AU/F Contact Contact-carrying portion: Gold-plated phosphor bronze Press-fit portion: Tin-plated phosphor bronze Screw Nickel-plated steel Cable UL2464 interface cable Equivalent to AWG28 Crimp terminal Fork- -type crimp terminal Equivalent to 1.25YAS3.5
Unit: mm (inch)
3 XW2Z- PPPA FOR 32-POINT PLC I/O MODULES (CONNECTOR TYPE)
The G79-PC Cable with a connector for the G7TC cannot be used for the XW2C due to a difference in wiring. The G79-PC Cable can be used for some of the XW2B Screw Terminal Blocks, refer to the XW2B data sheet. Cable length L Part number Cable length L XW2Z-050A 0.5 m (1.64 ft) XW2Z-100A 1 m (3.28 ft) XW2Z-150A 1.5 m (4.92 ft) XW2Z-200A 2 m (6.56 ft) XW2Z-300A 3 m (9.84 ft) XW2Z-500A 5 m (16.40 ft) Wiring Diagram FCN-367J024-AU/F (mated side) XG4M-2030 (mated side) Triangle mark Combinations of Omron PLC I/O Modules and Screw Terminal Blocks PLC I/O module I/O points Terminal block Dedicated cable C200H-ID215 C200H-OD215 C200H-MD215 C200H-MD115 C200H-MD501 C200H-ID501 C200H-OD501 C500-ID218CN C500-ID501CN C500-OD415CN C500-MD211CN C500-OD501CN 32 points input 32 points output 16 points in/16 points out 16 points in/16 points out 16 points in/16 points out 32 points input 32 points output 32 points input 32 points input 32 points output 16 points in/16 points out 32 points output XW2B-20G5 XW2B-20G4 XW2B-40G5-T XW2B-20G5-D XW2Z- PPPA C200H-ID215 C200H-ID501 C500-ID218CN C500-ID501CN C200H-MD215 C200H-MD115 C200H-MD501 C500- -MD211CN 32 points input 32 points input 32 points input 32 points input 16 points in/16 points out 16 points in/16 points out 16 points in/16 points out 16 points in/16 points out XW2C-20G5-IN16 (See Note 3) Note: 1. The G79-P Cable with a connector for the G7TC cannot be used for the XW2C due to a difference in wiring. The G79-PC Cable can be used for some of the XW2B Screw Terminal Blocks, refer to the XW2B data sheet. 2. The Input or Output Modules above have two connectors, so each one can use up to two Terminal Blocks and two dedicated cables. 3. The XW2C is a dedicated Input Terminal Block. If the XW2C is connected to a PLC module that handles both input and output signals (modules with “MD” in the part number), only the input portion of the PLC module can be used.
Unit: mm (inch)
3 XW2Z- PPPB FOR 32-POINT AND 64-POINT PLC I/O MODULES (CONNECTOR TYPE)
Part number Cable length L XW2Z-050B 0.5 m (1.64 ft) XW2Z-100B 1 m (3.28 ft) XW2Z-150B 1.5 m (4.92 ft) XW2Z-200B 2 m (6.56 ft) XW2Z-300B 3 m (9.84 ft) XW2Z-500B 5 m (16.40 ft) Wiring Diagram FCN-367J040-AU/F (mated side) XG4M-4030 (mated side) Triangle mark Combinations of Omron PLC I/O Modules and Screw Terminal Blocks PLC I/O module I/O points Terminal block Dedicated cable CQM1-ID213 CQM1-OD213 C200H-ID216 C200H-OD218 C200H-OD21B 32 points XW2B-40G5 XW2B-40G4 XW2Z- PPPB C200H-ID111 C200H-ID217 C200H-OD219 C500-ID114 3G2A5-ID219 3G2A5-OD213 64 points Note: 32-point I/O modules use one Terminal Block and one dedicated cable. 64-point I/O modules use two Terminal Blocks and two dedicated cables.
3 XW2Z- PPPD FOR 32-POINT AND 64-POINT PLC I/O MODULES (CONNECTOR TYPE)
A Line B Yellow Black A B 250 (9.84) 500 (19.68) XW2Z- P00D Part number Cable length A Cable length B XW2Z-100D 1 m (3.28 ft) 0.75 m (2.46 ft) XW2Z-150D 1.5 m (4.92 ft) 1.25 m (4.10 ft) XW2Z-200D 2 m (6.56 ft) 1.75 m (5.74 ft) XW2Z-300D 3 m (9.84 ft) 2.75 m (9.02 ft) XW2Z-500D 5 m (16.40 ft) 4.75 m (15.58 ft) Note: 1. CN2 (black cable side) is wired to line A of CN1 and CN3 (yellow cable side) is wired to line B of CN1. 2. The G79-PC Cable for the G7TC Terminal Block can- not be used for the XW2C due to a difference in wiring. FCN-367J024-AU/F CN1 (mated side) XG4M-2030 CN3 (mated side) Triangle mark XG4M-2030 CN2 (mated side) Triangle mark Wiring Diagram Combinations of Omron PLC I/O Modules and Screw Terminal Blocks PLC I/O module I/O points Terminal block Dedicated cable CQM1-ID213 C200H-ID216 32 points Two XW2C-20GS-IN16 input blocksOne XW2Z- PPPD cable C200H-ID217 C 500-ID 114 64 points Four XW2C-20GS-IN16 input blocksTwo XW2Z- PPPD cables C 500-ID 114 3G2A5-ID219
Unit: mm (inch)
3 XW2Z- PPPH-P FOR 96-POINT CS1 PLC I/O MODULES (CONNECTOR TYPE)
XW2Z- P00H-2 XW2Z- P00H-3XW2Z- P00H-1 A A A B B C Part number Cable length A XW2Z-100H-1 1 m (3.28 ft) XW2Z-200H-1 2 m (6.56 ft) XW2Z-300H-1 3 m (9.84 ft) XW2Z-500H-1 5 m (16.40 ft) Part number Cable length A Cable length B XW2Z-100H-2 1 m (3.28 ft) 1 m (3.28 ft) XW2Z-200H-2 2 m (6.56 ft) 2 m (6.56 ft) XW2Z-300H-2 3 m (9.84 ft) 3 m (9.84 ft) XW2Z-500H-2 5 m (16.40 ft) 5 m (16.40 ft) Part number Cable length A B C XW2Z-100H-3 1 m (3.28 ft)0.75 ft (2.45 ft)1 m (3.28 ft) XW2Z-200H-3 2 m (6.56 ft)1.75 ft (5.74 ft)2 m (6.56 ft) XW2Z-300H-3 3 m (9.84 ft)2.75 ft (9.02 ft)3 m (9.84 ft) XW2Z-500H-3 5m (16.40 ft) 4.75 ft (15.58 ft) (16.40 ft) Combinations of Omron PLC I/O Modules and Screw Terminal Blocks PLC I/O module I/O points Terminal blocks Dedicated cable CS1W-ID291, CS1W-OD291, CS1W-OD292 CS1W-MD291, CS1W-MD292 96 points Two XW2B-60G P terminal blocks Two XW2Z- PPPH-1 cables CS1W-ID291, CS1W-OD291, CS1W-OD292 CS1W-MD291, CS1W-MD292 96 points Two XW2B-40G4 + XW2B-20G4 or two XW2B-40G5 + XW2B-20G5 terminal blocks Two XW2Z- PPPH-2 cables CS1W-ID291, CS1W-OD291, CS1W-OD292 CS1W-MD291, CS1W-MD292 96 points Six XW2B-20G4 or six XW2B-20G5 terminal blocks Two XW2Z- PPPH-3 cables Note: For detailed information about connector pin-outs, refer to CS1 Operation Manual (W339), Appendix A.
3 XW2Z- PPPF CABLE WITH CRIMP TERMINALS (20 POLES)
(M3.5) 300 (11.81) Wiring Diagram XG4M-2030 (mated side) Triangle mark Terminal Y (M3.5) Part number Cable length L XW2Z-100F 1 m (3.28 ft) XW2Z-150F 1.5 m (4.92 ft) XW2Z-200F 2 m (6.56 ft) XW2Z-300F 3 m (9.84 ft) XW2Z-500F 5 m (16.40 ft) Combinations of Omron PLC I/O Modules and Screw Terminal Blocks PLC I/O module Terminal block Dedicated cable Use any I/O module with a terminal block from Omron or another manufacturer, or an I/O board for a computer. XW2B-20G5 XW2B-20G4 XW2Z- PPPF
3 CONNECTIONS BETWEEN OMRON’S I/O MODULES AND SCREW TERMINAL BLOCKS
Item Input (ID) Output (OD) PLC I/O modules C200H-ID215 C200H-ID501 C500-ID501CN C500-ID218CN 32-point input modules use two blocks and two cables. C200H-OD215 C200H-OD501 C500-OD501CN 32-point output modules use two blocks and two cables. Terminal blocks XW2B-20G5 XW2B-20G4 XW2B-20G5 XW2B-20G4 Cable XW2Z- PPPA XW2Z- PPPA Connection diagram XW2B- -20G5 XW2B- -20G5 Cable G79-PC G79-PC Connection diagram XW2B-20G5 XW2B-20G5
Item Output (OD) PLC I/O module C500-OD415CN 32-point output module uses two blocks and two cables. Terminal block XW2B-20G5 XW2B-20G4 Cable XW2Z- PPPA G79-PC Connection diagram XW2B-20G5 XW2B-20G5 XW2B-20G5 XW2B-20G5
Item Mixed I/O (MD) PLC I/O modules C200H-MD115 C200H-MD215 C200H-MD501 C500-MD211CN 16-point input/16-point output mixed I/O modules use two blocks and two cables. Terminal blocks XW2B-20G5 XW2B-20G4 Cable XW2Z- PPPA G79-PC Connection diagram XW2B-20G5 XW2B-20G5 XW2B-20G5 XW2B-20G5
Item Group 2 High- -density Input/Output PLC I/O module CQM1-ID213 32-point Use one terminal block and one cable. C200H-ID216 32-point Use one terminal block and one cable. C200H-ID111 64-point Use two terminal blocks and two cables. C200H-ID217 64-point Use two terminal blocks and two cables. C500-ID114 64-point Use two terminal blocks and two cables. 3G2A5-ID219 64-point Use two terminal blocks and two cables. CQM1-OD213 32-point Use one terminal block and one cable. C200H-OD218 32-point Use one terminal block and one cable. C200H-OD219 64-point Use two terminal blocks and two cables. Terminal block XW2B-40G5 XW2B-40G4Cable XW2Z- PPPB Connection diagram XW2B-40G5 () ()
Item High-density I/O 1:1 Connection PLC I/O module CS1W-ID29 P CS1W-OD29 P CS1W-MD29 P Use two terminal blocks and two cables. Terminal block One XW2B-60G5 or one XW2B-60G4 per cable Cable XW2Z- PPPH-1 Connection XW2B-60G P Item High-density I/O 1:2 Connection PLC I/O module CS1W-ID29 P CS1W-OD29 P CS1W-MD29 P Use two 40-point and two 20-point terminal blocks and two cables. Terminal block XW2B-40G5 + XW2B-20G5 blocks or XW2B-40G4 + XW2B-20G4 blocks per cable Cable XW2Z- PPPH-2 Connection XW2B-40G P XW2B-20G P Note: For detailed information about connector pin-outs, refer to CS1 Operation Manual (W339), Appendix A.
Item High-density I/O 1:3 Connection PLC I/O module CS1W-ID29 P CS1W-OD29 P CS1W-MD29 P Use six 20-point terminal blocks of the same kind and two cables. Terminal block Three XW2B-20G5 blocks or three XW2B-20G4 blocks per cable Cable XW2Z- PPPH-3 Connection XW2B-20G P XW2B-20G PXW2B-20G P Note: For detailed information about connector pin-outs, refer to CS1 Operation Manual (W339), Appendix A. OMRON ELECTRONICS, INC. O n eE a s tC o m m e r c eD r i v e Schaumburg, IL 60173 NOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4. 1-800-55-OMRON OMRON CANADA, INC.
885 Milner Avenue