Greegoo Electric 5.2008 http://www.greegoo.com Surge Protective Device Signal Type Surge Protector Device BYX-BNC Coaxial Signal Lightning Protector

Description

BYX-BNC coaxial signal lightning protector perfect shape dimenstion, IP standard mode and 35mm DIN rail 35mm installation. Ports direction can be choose by one sides or different sides, easily to install. Product height is IU standard dimension, easily assemble several modules into19 inches standard cabinet brace and also can adjust lightning connector and voltages to meet different requests, come to freely conveniently combination and installation. ■ Discharge current come to 10KA ■ Low voltage protection level ■ DIN rail 35mm installation ■ Two ports and two class surge protection ■ Multi-connectors standard module design ■ High response speed ■ Bidirection connectors (F/M,F/F) ■ Super transmisstion performance, low insert loss ■ Information system surge over voltage protector ■ Can integrate 1-24 ports combination mode Performance parameters Scope of application ■ Protection of public CATV terminal equipment ■ Protection of monitoring system video equipment ■ Protection of coaxial network signal equipment ■ Protection of other signal equipment 6VDC 7.2VDC >0.1M 20V 5kA, 10 times 10kA, 2 times 0.5A 2A, 1s, 5 times 1.5kV. 10/700 S 37.5A. 10/300 S BYX-BNC 10 times Mode 2 0.5dB 1.2 1.5 BNC Connector 1ns UL94V-0/IP20 Atmospheric pressure 80kPa~160kPa Temperature -40 ~+70 Relative humid 5%~96% See figure 35mm DIN trail (1.2/50 S, 0.5kV) Up Type Rated operting voltage Max. continuous operating voltage Uc Insulation resistance Voltage protection level In(8/20 S ) Imax(8/20 S ) Nominal discharge current Rated operating current AC withstand capability of resistance Withstand capability of impulse Max.discharge current Over load failure mode Insert loss(10MHz) Resistance VSWR Serial resistance Connector type Response time Dimension Shell material/ shell protection class Installation mode Usage condition BNC core wire- BNC shield Different input ports With earthing terminal Connect to equipment Connect coaxial circuit Same sides Earthing terminal Connect coaxial circuit Connect to the protected 18.5mm 101mm 42mm 18.5mm 82.5mm 42mm BYX-BNC Un: 6VDC Uc: 7.2VDC ln: 5kA Up: 20V IN OUT Safe Coaxial Safe Coaxial Un: 6VDC Uc: 7.2VDC ln: 5kA Up: 20V BYX-BNC BYX-BNC

Greegoo Electric 5.2008 http://www.greegoo.com Signal Type Surge Protector Device Dimension 6VDC 7.2VDC >0.1M 20V 5kA, 10 times 10kA, 2 times 0.5A 2A, 1s, 5 times 1.5kV. 10/700 S 37.5A. 10/300 S BYX-BNC 10 times Mode 2 0.5dB 1.2 1.5 BNC Connector 1ns UL94V-0/IP20 Atmospheric pressure 80kPa~160kPa Temperature -40 ~+70 Relative humid 5%~96% See figure 35mm DIN trail (1.2/50 S, 0.5kV) Up Type Rated operting voltage Max. continuous operating voltage Uc Insulation resistance Voltage protection level In(8/20 S ) Imax(8/20 S ) Nominal discharge current Rated operating current AC withstand capability of resistance Withstand capability of impulse Max.discharge current Over load failure mode Insert loss(10MHz) Resistance VSWR Serial resistance Connector type Response time Dimension Shell material/ shell protection class Installation mode Usage condition BNC core wire- BNC shield Different input ports With earthing terminal Connect to equipment Connect coaxial circuit Same sides Earthing terminal Connect coaxial circuit Connect to the protected 18.5mm 101mm 42mm 18.5mm 82.5mm 42mm BYX-BNC Un: 6VDC Uc: 7.2VDC ln: 5kA Up: 20V IN OUT Safe Coaxial Safe Coaxial Un: 6VDC Uc: 7.2VDC ln: 5kA Up: 20V BYX-BNC