BY75SW OMRON | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 70
Technical content
- This manual gives you important information to use the this unit safely and therefore be sure to read it before installation and use.
- Keep this manual handy at the place where you install the this unit so that you can read it whenever necessary. BX75XS2 Uninterruptible Power Supply (UPS) Instruction Manual BY50FW/BY75SW
Notes on the use of the Unit The unit is designed and manufactured for use for OA equipment such as personal computers. Do not use it when very high reliability and safety are required as listed belo w.
- Medical equipment that may cause death directl y
- Applications that may cause injury (applications that directly affect the operation and control of planes, ships, railroads, elevators, and so on)
- Applications that are always subjected to vibration such as cars and ships
- Applications in which a failure of this product may cause significant damage or ef fect to the society and public (essential computer systems, main communication equipment, public transportation systems, and so on)
- Equipment with the same level of importanc e For equipment that greatly affects the safety of people and maintaining public functions, special considerations must be taken for operation, maintenance, and management, such as duplication of the system and emergency power generation facilities . Observe the contents of this manual such as the use conditions and environments. If you want to use the unit for an important system that requires very high reliability, contact the shop of purchase. Do not modify/alter the unit. This product is designed for use within Japan. When incorporating this product into equipment for export, please contact the shop of purchase.
- The export of this product (including transport by an individual) may require the permission of the Ministry of Economy, Trade and Industry under the Foreign Exchange and Foreig n Trade Law. Export of this product without the required permission is punishable under the law.
- Injury or fire may result if the voltage or frequency is different . ©OMRON SOCIAL SOLUTIONS CO.,LTD. 2006-2019 All Rights Reserved. Introduction Thank you for purchasing the POWLI BY50FW/BY75SW Uninterruptible Power Supply (UPS) . This unit is a UPS designed specifically for personal computers. The UPS protects (backs up) personal computers, displays, peripherals, and so on up to a power consumption of 500VA/300W (BY50FW), 750VA/450W (BY75SW) from failures in the power supply, such as power failures and voltage variations . It protects connected devices from surge coming from power line . You can easily replace batteries by yourself. By using the UPS monitoring software, the system can be shut down automatically when a power failure occurs. Read this manual thoroughly to make the most of the unit . Disclaimers We are not liable to all damage including malfunction and failure of equipment, connected devices, and software and other secondary damage even if it is caused by the use of our product. Make sure to read the safety precautions before using the unit.
IMPORTANT SAFETY INSTRUCTION 1.SAVE THESE INSTRUCTIONS. This manual contains important instruction for Model BY50FW, BY75SW. That should be followed during instruction of the UPS and batteries. 2.SYMBOL This symbol indicates earth ground. This symbol indicates turning on UPS. This symbol indicates turning off UPS. 3.INTERNAL BATTERY Internal battery is Lead-acid type. For BY50FW model, the internal battery voltage is 6V 7.2AH. Each UPS used 2pcs batteries. And the total battery voltage is 12Vdc. For BY75SW model, the internal battery voltage is 12V 7AH or 7.2AH. The UPS used 2pcs batteries. And the total battery voltage is 24Vdc. 4.TEMPERATURE RATING Maximun ambit temperature of UPS 40°C. 5.ENVIRONMENT The unit is intended for installation in a temperature controlled, indoor area free of conductive contaminants. This pluggable type A equipment with battery already installed by the supplier is operator installable and may be operated by laymen. During the installation of this equipment it should be assured that the sum of the leakage currents of the UPS and the connected loads does not exceed 3.5mA. The mains socket outlet that supplies the UPS shall be installed near the UPS and shall be easily accessible. For battery information, see users manual.
Procedure from installation to operation Yes No No Yes StartRead “Safety precautions” Pages 4 – 10 Perform installation and connection Page 15 Check the operation Page 24 Charge the battery Page 26 Measure the backup time Page 26 Operate Page 27 Perform maintenance and inspection Page 39 Replace the battery Page 40 Deteriorated battery? Recharge the battery again Page 26 * Preparation is complete. Remove the product from the package and check the contents Page 11 Installation/connection Preparation for operation Maintenance/inspection It is possible to omit the backup time measurement step. Are you using UPS monitoring software or contact signal? "Using the UPS monitoring software and contact signal" Page 47
■ Table of Contents ■ 6-3 When performing auto-save functions using the UPS service in 6-4 When performing auto-save functions using the standard UPS service in
Do not use this unit when very high reliability and safety are required as listed below. This unit is designed and manufactured for use with OA equipment such as personal computers.
- Medical equipment or system that may cause death directly.
- Applications that directly affect the safety of people (For example, the operation and control of cars and elevators).
- Applications in which a failure of the unit may cause significant damage to the society and public (For example, essential computer systems and main communication equipment.)
- Applications with the same level of importance.
- Not for use in a computer room as defined in the Standard for the Protection of Electronic Computer/Data Processing Equipment, ANSI/NFPA75. Carry the unit considering its weight and balance, and place it on a stable and robust base.
- Dropping or toppling the unit may cause injury.
- The weight of this unit is approximately: 6 kg (BY50FW)/ 9 kg (BY75SW).
- If you drop the unit, stop using it and have an inspection and repair be done. For repair, contact the shop of purchase. Keep plastic package bags out of reach of children.
- They may put their heads into it, and may be suffocated. Make sure to connect the AC input plug of the unit into a wall outlet (commercial power) with rated input voltage.
- Connecting to a wall outlet (commercial power) of a different rated input voltage may result in fire.
- The unit may fail. Do not connect devices such as dryers, which have a half-wave rectifier where only half-cycles of the AC power flows.
- Overcurrent may damage the UPS.. :I ndicates prohibition. For example, indicates that disassembly is prohibited . :I ndicates obligation. For example, indicates that grounding is necessar y. Misuse may cause death or serious injury.Warning Caution The safety symbols and their meaning used in this manual are as follows: * Property damage means damage to houses/household effects, livestock, and pets. Note that events categorized as a caution required matter also may cause more serious results under certain conditions. Do not use this unit when very high reliability and safety are required as listed below. This unit is designed and manufactured for use with OA equipment such as personal computers. Medical equipment or system that may cause death directly. Applications that directly affect the safety of people (For example, the operation and control of cars and elevators). Applications in which a failur e of the unit may cause significant damage to the society and public (For example, essential computer systems and main communication equipment.) Applications with the same level of importance. Not for use in a computer room as defined in the Standard for the Protection of Electronic Computer/Data Processing Equipment, ANSI/NFPA75. Warning Important information for safe operation is described. Be sure to read it before installation and start of use. Misuse may cause injury or property damage. Carry the unit considering its weight and balance, and place it on a stable and robust base. Dropping or toppling the unit may cause injury. The weight of this unit is approximately: 6 kg (BY50FW)/ 9 kg (BY75SW). If you drop the unit, stop using it and have an inspection and repair be done. For repair, contact the shop of purchase. Keep plastic package bags out of reach of children. They may put their heads into it, and may be suffocated. Make sure to connect the AC input plug of the unit into a wall outlet (commercial power) with rated input voltage. Connecting to a wall outlet (commercial power) of a different rated input voltage may result in fire. The unit may fail. Caution (for installation and connection) Safety precautions Warning Caution (for installation and connection)
Connect the unit to a wall outlet (commercial power) with a current capacity of 12A or more.
- Otherwise, the power cord may be heated.
- When equipment with the maximum output capacity is connected, a maximum current of 12A flows. Provide secure grounding.
- For a 3P wall outlet, directly connect the AC input plug of the unit to it. Not doing so may cause an electric shock in the case of unit failure or electric leakage.
- When you use a 3P-2P conversion plug for AC input plug, be sure to perform grounding be- fore connecting the AC input plug into a wall outlet (commercial power).
- Do not disconnect the grounding before disconnecting the AC input plug from a wall outlet (commercial power).
- Grounding is necessary to enable its surge protection function. Do not disassemble, repair, or modify the unit.
- Doing so may cause an electric shock or a fire. Do not install the unit in other than specified orientations.
- Dropping or toppling the unit may cause injury.
- If you install the unit in an orientation other than specified, the unit cannot be protected from a battery fluid leakage. Donot put any object on the unit whenever installing it vertically or horizontally.
- Doing so may cause distortion of/damage to the case, which may cause a fire. Do not use the unit where the maximum temperature exceeds 40°C.
- The battery becomes week rapidly, which may cause a fire.
- Doing so may cause a failure or malfunction of the unit. Do not install or store the unit in the places listed below.
- The humidity is lower than 25%. The humidity is higher than 85%. A closed place such as in a cabinet without clearance. There is flammable gas or corrosive gas. A place subject to vibration or shock. Outdoors.
- Installation or storing the unit in such a place may cause a fire. Do not use the unit in a closed place or do not cover the unit.
- Doing so may cause a failure or malfunction of the unit. Do not connect equipment that exceeds the output capacity of the unit.
- Overcurrent may damage the UPS or cause it to malfunction.
- Even when connected to the input side, the UPS may fail or malfunction. Make sure to check the operation before use. Do not use it in a condition listed below. - Blocking the ventilating hole - Placing objects on the unit - Stacking units (vertically or alongside)
- Doing so may cause abnormal heating, which may cause burns or damage the unit. Do not pinch or tie the cable of the unit.
- Doing so may cause the cable to be damaged or heated, which may cause an electric shock or a fire.
- If the cable is damaged, stop using the unit and the cable must be repaired. For repair, contact the shop of purchase. Caution (for installation and connection)
Do not wet or pour water onto the unit.
- Doing so may cause an electric shock or a fire.
- If you wet the unit, stop using it and the unit must be inspected and/or repaired. For repair, contact the shop of purchase. When the battery is dead, replace it immediately or stop using the unit.
- Continuing the use of it may cause fire or electric shock due to liquid leaks. Ambient temperature Expected life 20°C 4 to 5 years 30°C 2 to 2.5 years Wipe the 100-VAC input plug clean of dirt with a dry cloth occasionally.
- Settled dust may cause a fire. All of the included accessories are designed to be used exclusively with the unit. Do not use the accessories with other devices.
- Doing so may compromise the safety of devices.
- This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user serviceable parts. Only factory service personnel may perform repairs.
- Connection to any other type of receptacle other than a two-pole, three-wire grounded receptacle may result in shock hazard as well as violate local electical codes.
- Do not allow liquids or any foreign object to enter the UPS. DO not place beverages or any other liquid-containing vessels on or near the unit.
- This unit intended for installation in a controlled environment (temperature controlled, indoor area free of conductive contaminants). Avoid installing the UPS in locations where there is standing or running water, or excessive humidity.
- Do not attach a power strip or surge suppressor to the UPS.
- Do not attach non-computer-related items, such as medical equipment, life-support equip- ment, microwave ovens, or vacuum cleaners to UPS.
- With the installation of the equipment it should be prevented, that the sum of the leakage current of the UPS and the connected consumer does not exceed 3.5mA.
- For PLUGGABLE EQUIPMENT, the socket-outlet shall be installer near the equipment and shall be easily accessible. An additional circuit breaker or fuse with breaking capacity 3kA shall be used between power source and input when installation this unit. Caution (for installation and connection) Caution (for use) * The values in the table are the expected life under standard use conditions and are not guaranteed.
Caution (for battery replacement) If you notice abnormal sound or smell, smoke, or leakage from the inside, immediately turn off the power switch and disconnect the AC input plug from a wall outlet (commercial power). Using the unit under such conditions may cause a fire. If you notice such a condition, stop using the unit and contact the shop of purchase for inspection and repairs. Use the unit under the conditions in which you can immediately disconnect the AC input plug from a wall outlet (commercial power) in the case of an abnormal event. If fluid leaks from the unit, do not touch the fluid. Doing so may cause blindness or burns. If the fluid contacts your eyes or skin, wash it out with lots of clean water and consult your doctor. Caution (for maintenance) Perform replacement on a stable and flat place. Handle the battery carefully not to drop it. Not doing so could cause injury or burns due to liquid (acid) leakage. Risk of explosion if battery is replaced by an incorrect type. When replacing batteries, replace with the same type and number of batteries or battery packs. Not doing so may cause a fire. Product model: BXB50F (battery pack for BY50FW) BXB75S (battery pack for BY75SW) Do not replace the battery in a place where there is flammable gas. Spark may occur when connecting the battery, which may cause an explosion or fire. If fluid (dilute sulfuric acid) leaks from the battery, do not touch the fluid. Doing so may cause blindness or burns. If it contacts your eyes or skin, wash it out with lots of clean water and consult your doctor. Do not open or mutilate batteries. Released electrolyte is harmful to the skin and eyes. It may be toxic. When maintaining the connected equipment, turn OFF the power switch and disconnect the AC input plug. The backup function continues to supply power from the power output receptacles while the UPS is operating, even when the AC input plug is disconnected. Do not disassemble, repair, or modify the unit. Doing so may cause an electric shock or a fire. If fluid leaks from the unit, do not touch the fluid. Doing so may cause blindness or burns. If the fluid contacts your eyes or skin, wash it out with lots of clean water and consult your doctor. Do not throw the unit into fire. The lead battery in the unit may explode, or leak dilute sulfuric acid. Caution (for use)
Do not drop the battery or do not give strong impact on it.
- Dilute sulfuric acid may leak. Do not short the battery with metal objects.
- Doing so could cause an electric shock, fire or burn.
- Some electrical energy still remains inside the spent battery. Do not dispose of batteries in a fire.
- The batteries may explode. Dispose of used batteries according to the instructions. Replacement of batteries located in a SERVICE ACCESS AREA 1) Servicing of batteries should be performed or supervised by personnel knowledgeable about batteries and the required precautions. 2) A battery can present a risk of electrical shock and high short circuit current. The following precautions should be observed when working on batteries: a. Remove watches, rings, or other metal objects. b. Use tools with insulated handles. c. Wear rubber gloves and boots. d. Do not lay tools or metal parts on top of batteries. e. Disconnect charging source prior to connecting or disconnecting battery terminals. f. Determine if battery is inadvertently grounded. If inadvertently grounded, remove source from ground. Contact with any part of a grounded battery can result in electrical shock. The likelihood of such shock can be reduced if such grounds are removed during instal- lation and maintenance (applicable to equipment and remote battery supplies not having a grounded supply circuit). Do not dispose of batteries in a fire. The batteries may explode. Dispose of used batteries according to the instructions. Do not open or mutilate batteries. Released electrolyte is harmful to the skin and eyes. It may be toxic. Caution (for battery replacement) Protéger les batteries du feu. Risque d’explosion des batteries. Utilisez les batteries conformément aux instructions. Ne pas ouvrir ni détériorer les batteries. Les fuites d’électrolyte sont dangereuses pour la peau et les yeux. Les batteries peuvent présenter un risque de choc électrique avec un fort courant de court circuit. Les précautions suivantes doivent être suivie lors de l’intervention sur les batteries : a: retirer les montres, bagues et autre objets en métal b: Utilisez des outils a manche isolé c: Utilisez des gants et des chaussures isolant d: Ne pas laisser des outils ou des objets métalliques proches des batteries e: Déconnecter le chargeur avant de connecter ou de déconnecter les batteries f: Determiner si la pile est mise a la terre. Si elle est mise a la terre, effectuer la deconnection. Le contact avec une pile mise a la terre peut creer un choc electrique. Ceci sera reduit si cette mie a la terre est supprimee pendant installation et maintenance. Attention
When moving the unit from a cold place to a warm place, leave it for several hours before using it.
- If the unit is moved to a warmer place and the power is turned on soon, the unit failure may occur due to condensation to the unit. Charge the battery for at least 12 hours soon after purchasing the unit.
- If you do not use the unit for a long time after the purchase, the property of the battery may deteriorate and the battery may become unusable.
- To charge a battery, connect the AC input plug of the unit to a wall outlet (commercial power). When storing the unit, charge the battery for at least 12 hours and turn off the power switch.
- Even if the unit is not used, the battery gradually discharges, and if it is left for a long time, it goes into an over discharge state. The backup time may become shorter or the battery may become unusable.
- We recommend keeping the temperature 40°C or less when storing the unit for long periods of time. Connect the unit’s AC input plug to a wall outlet (commercial power) for at least 12 hours at the following intervals: - Every 6 months when storage temperature is 25°C or less - Every 2 months when storage temperature is 40°C or less
- Turn off the power switch of the unit during storage. Do not short the output lines of the unit each other and the output lines to the ground.
- The unit may fail. Do not connect the AC input plug of the unit to its Power Supply Output. Receptacle during the Battery Mode.
- The unit may fail. Do not connect a page printer (laser printer, copy machine, etc.) to the unit.
- The Commercial Power Mode and Battery Mode are repeated frequently, which may shorten the life of the battery.
- As the peak current of a page printer is large, an excess of the connection capacity or a power failure due to instantaneous voltage drop may be detected. This unit is a full-time commercial power supply method uninterruptible power supply (UPS). Do not use the unit with the types of devices described below.
- Devices that experience problems in the event of a momentary power failure of 8 msec. (0.008 sec.) or less. Switching time of 8 msec. or less occurs, which has the potential to cause connected devices to stop.
- Devices that require a highly stable power supply. Instantaneous fluctuations in the output voltage have the potential to cause connected devices to stop. If the unit is used with an inductive device, check the operation beforehand.
- With some types of devices, the effect of inrush current may cause this unit to stop operating properly.
- An inductive device is one that has transformers, coils, motors, etc. built into the input. Do not fail to confirm the system operation beforehand if the unit is used combined with devices which power supply frequency fluctuate widely, such as private electric generator.
- This unit automatically recognizes the input power frequency when input power is supplied. If the unit is connected when the input power frequency is not stable at the rated level, the unit may mis- identify the power supply frequency and may fail to operate normally. (If the unit is in operation, changing from commercial power supply to another power supply source, such as generating equipment, will cause no problem.)
Do not install or store the unit in a place exposed to direct sunlight.
- The rise of temperature may cause the built-in battery to deteriorate rapidly and become unusable. Do not perform a withstand voltage test.
- The input circuit has a built-in surge absorption device. A withstand voltage test may break it.
- When performing an insulation resistance test, use the 250 VDC range. Before stopping commercial power to the unit, turn OFF the power switch of the unit.
- The unit enters Battery Mode when commercial power is stopped. If you frequently use the unit in Battery Mode, the battery life may be significantly shortened. Do not fail to confirm the system operation beforehand if the unit is used other than “Output 100V mode”.
- At the time of battery operation, the maximum voltage (peak voltage) of output (sine wave) may be lower than the maximum voltage at the time of usual operation (commercial power supply). For this reason, some connected devices may fail to operate normally. Battery recycling
- This unit uses lead acid batteries. The lead acid batteries are precious recyclable resources. Please cooperate recycling. For information on recycling, please contact the shop of purchase. Take measures for handling unforeseen accidents, such as data backup and system redundancy.
- The output may stop when there is a circuit failure. In the event you transfer or sell this unit to a third party, please include all of the documentation that came with the unit. This is to ensure that the unit is used in line with the conditions described in the included documentation.
- This manual contains important safety-related information. Please read and understand the contents of the manual before beginning operation. Explanation Usual operation
- You may either leave the power switch of the unit on (operation status) or turn it off each time when stop- ping the connected system. You can choose either of the operation methods for your convenience. We recommend turning off the power switch when you do not use connected devices for a long time.
- The battery is charged when the AC input plug of the unit is connected to a wall outlet (commercial power). End of Battery Mode
- If a power failure lasts long, the battery discharges and power output from the unit stops. Shut down your computer after performing appropriate procedure (for example, saving data) while the unit supplies power. Reboot
- If the battery discharges completely during a power failure, the unit stops. After recovery from the power failure, the unit automatically restarts and supplies power. If you do not want to restart the connected de- vices, turn OFF the power switch of either the unit or the connected devices while the power is out. It is also possible to deactivate the auto restart by turning ON the auto restart setting (setting switch 2 ). (See page 33.)
- Preparation 1. Preparation 1-1 Checking the contents BY50FWB Y75SW Instruction manual (Japanese and English versions) 1 each 1 each Wa 11drac ytnarr 11drac noitartsiger resU 11rotpada noisrevnoc P2-P3 Label (How to determine operating status) 11 4enoNteef rebbuR Ver enoN)seceip 2( tes 1dnats lacit 11rotcennoc FFO/NO etomeR Check whether all the package contents are included and there is no damage found on their appearance. If you should notice defects or anything wrong, contact the shop of purchase. (1) Accessories related to the main unit (2) Auto shutdown software BX50FW/BX75SW 1ediuG llatsnI kciuQ 1MOR-DC USB/communication cable (Approx. 2.2m) 1 (USB) Serial communication cable (Approx. 2m) 1 (USB) <Accessories related to the main unit > 3P-2P conversion plug Connector for remote ON/OFF CD-ROM Rubber feet (BY75SW only) Serial communication cable (Approx. 2m) USB/communication cable (Approx. 2.2m) User registration card Label (How to determine operating status) Quick Installation guide Instruction manual Vertical stand (BY50FW only) <Auto shutdown software> Warranty card
- Preparation BY50F Front view Rear view Power supply output receptacle AC input overcurrent protection Communication method selection switch Dip switch USB communication connector Remote ON/OFF connector Serial/Dry contact communication connector Grounding terminal AC input cable/plug Digital status indicator Beep stop/test switch Battery replacement indication lamp Power switch Battery replacement cover 1-2 Part names
- Preparation BY75SW Front view Digital status indicator Battery replacement cover Battery replacement indication lamp Beep stop/test switch Power switch Dip switch Serial/Dry contact communication connector Power supply output receptacle Communication method selection switch Grounding terminal AC input cable/plug AC input overcurrent protection USB communication connector Remote ON/OFF connector Rear view
- Preparation 1-3 Explanation of symbol used on unit noitpircseDlobmyS Start the UPS. Stop the UPS. Suspend a beep.
- Installation and connection Carry the unit considering its weight and balance, and place it on a stable and robust base.
- Dropping or toppling the unit may cause injury.
- The weight of this unit is approximately: 5.3 kg (BY50FW)/ 8.7 kg (BY75SW).
- If you drop the unit, stop using it and have an inspection and repair be done. For repair, contact the shop of purchase. Keep plastic package bags out of reach of children.
- They may put their heads into it, and may be suffocated. Make sure to connect the AC input plug of the unit into a wall outlet (commercial power) with rated input voltage.
- Connecting to a wall outlet (commercial power) of a different rated input voltage may result in fire.
- The unit may not operate properly when connected to a generator or to a power supply that passes through a transformer.
- The unit may fail. Do not connect devices such as dryers, which have a half-wave rectifier where only half-cycles of the AC power flows.
- Overcurrent may damage the UPS. Connect the unit to a wall outlet (commercial power) with a current capacity of 12A or more.
- Otherwise, the power cord may be heated.
- When equipment with the maximum output capacity is connected, a maximum current of 12A flows. Provide secure grounding.
- For a 3P wall outlet, directly connect the AC input plug of the unit to it. Not doing so may cause an electric shock in the case of unit failure or electric leakage.
- When you use a 3P-2P conversion plug for AC input plug, be sure to perform grounding be- fore connecting the AC input plug into a wall outlet (commercial power). Do not disconnect the grounding before disconnecting the AC input plug from a wall outlet (commercial power).
- Grounding is necessary to enable its surge protection function. Do not disassemble, repair, or modify the unit.
- Doing so may cause an electric shock or a fire. Do not install the unit in other than specified orientations.
- Dropping or toppling the unit may cause injury.
- If you install the unit in an orientation other than specified, the unit cannot be protected from a battery fluid leakage. Caution (for installation and connection) 2. Installation and connection 2-1 Precautions and notes on installation and connection
- Installation and connection Notes When moving the unit from a cold place to a warm place, leave it for several hours before using it.
- If the unit is moved to a warmer place and the power is turned on soon, the unit failure may occur due to condensation to the unit. Charge the battery for at least 12 hours soon after purchasing the unit.
- If you do not use the unit for a long time after the purchase, the property of the battery may deteriorate and the battery may become unusable.
- To charge a battery, connect the 100 VAC input plug of the unit to a wall outlet (commercial power). When installing the unit either vertically or horizontally, do not put any objects on it.
- Doing so may cause distortion of/damage to the case, which may cause a fire.
- The life of the battery and electronic components may shorten due a decrease in the heat dissipation performance. This may lead to a failure of the device. Do not use the unit where the maximum temperature exceeds 40°C.
- The battery becomes week rapidly, which may cause a fire.
- Doing so may cause a failure or malfunction of the unit. Do not install or store the product in the places listed below. Do not install or store the unit in the places listed below.
- The humidity is lower than 25%. The humidity is higher than 85%. A closed place such as in a cabinet without clearance. There is flammable gas or corrosive gas. A place subject to vibration or shock. Outdoors.
- Installation or storing the unit in such a place may cause a fire. Do not use the unit in a closed place or do not cover the unit.
- Doing so may cause abnormal heating or a fire. Do not connect equipment that exceeds the output capacity of the unit.
- The current protection of the unit may operate, which may stop the output.
- The wiring of the plug strip heats up, which may cause a fire. Do not pinch or tie the cable of the unit.
- Doing so may cause the cable to be damaged or heated, which may cause an electric shock or a fire.
- If the cable is damaged, stop using the unit and the cable must be repaired. For repair, contact the shop of purchase. All of the included accessories are designed to be used exclusively with the unit. Do not use the accessories with other devices.
- Doing so may compromise the safety of devices. Caution (for installation and connection)
- Installation and connection Notes When storing the unit, charge the battery for at least 12 hours and turn off the power switch.
- Even if the unit is not used, the battery gradually discharges, and if it is left for a long time, it goes into an over discharge state. The backup time may become shorter or the battery may become unusable.
- We recommend keeping the temperature 40°C or less when storing the unit for long periods of time. Connect the unit’s AC input plug to a wall outlet (commercial power) for at least 12 hours at the following intervals: - Every 6 months when storage temperature is 25°C or less - Every 2 months when storage temperature is 40°C or less
- Turn off the power switch of the unit during storage. Do not short the output lines of the unit each other and the output lines to the ground.
- The unit may fail. Do not connect the AC input plug of the unit to its Power Supply Output. Receptacle during the Battery Mode.
- The unit may fail. Do not connect a page printer (laser printer, copy machine, etc.) to the unit.
- The Commercial Power Mode and Battery Mode are repeated frequently, which may shorten the life of the battery.
- As the peak current of a page printer is large, an excess of the connection capacity or a power failure due to instantaneous voltage drop may be detected. This unit is a full-time commercial power supply method uninterruptible power supply (UPS). Do not use the unit with the types of devices described below.
- Devices that experience problems in the event of a momentary power failure of 8 msec. (0.008 sec.) or less. Switching time of 8 msec. or less occurs, which has the potential to cause connected devices to stop.
- Devices that require a highly stable power supply. Instantaneous fluctuations in the output voltage have the potential to cause connected devices to stop. If the unit is used with an inductive device, check the operation beforehand.
- With some types of devices, the effect of inrush current may cause this unit to stop operating properly.
- An inductive device is one that has transformers, coils, motors, etc. built into the input. Do not fail to confirm the system operation beforehand if the unit is used combined with devices which power supply frequency fluctuate widely, such as private electric generator.
- This unit automatically recognizes the input power frequency when input power is supplied.
- If the unit is connected when the input power frequency is not stable at the rated level, the unit may mis- identify the power supply frequency and may fail to operate normally. (If the unit is in operation, changing from commercial power supply to another power supply source, such as generating equipment, will cause no problem.) Do not install or store the unit in a place exposed to direct sunlight.
- The rise of temperature may cause the built-in battery to deteriorate rapidly and become unusable. Do not perform a withstand voltage test.
- The input circuit has a built-in surge absorption device. A withstand voltage test may break it.
- When performing an insulation resistance test, use the 250 VDC range. Before stopping commercial power to the unit, turn OFF the power switch of the unit.
- The unit enters Battery Mode when commercial power is stopped. If you frequently use the unit in Battery Mode, the battery life may be significantly shortened. Do not fail to confirm the system operation beforehand if the unit is used other than "Output 100V mode".
- At the time of battery operation, the maximum voltage (peak voltage) of output (sine wave) may be lower than the maximum voltage at the time of usual operation (commercial power supply). For this reason, some connected devices may fail to operate normally.
- Installation and connection 2-2 Installation and connection (BY50FW) Connection to back up your computer and peripherals (2) Install the unit. Do not install the unit in any position other than those indicated below. Write the usage start date on the label on the top side. Also, by using the included UPS monitoring software, possible to keep a record of usage start date by the software. (1) Disconnect all AC input plugs of your computer and peripherals from a wall outlet (commercial power). Note Before installing this device, make a record of the serial number of this device. The serial number is required when contacting the shop of purchase about the device. The serial number is written in the label on the unit. Horizontal BY50FW Vertical BY50FW (Attach the included stand so that the left side is the bottom.)
- Detach the rubber feet from the bottom surface (both at the front and rear) when positioning vertically.
- O nce the rubber feet ar e removed, protrusions on the bottom su rface will become visible. Align the stand with these protrusions to attach it . Remove the rubber feet and attach the stand. Computer Modem or other peripheral Wall outlet (commercial power)
- Installation and connection Do not position the unit in the ways shown below. (3) Connect devices that require backup to the unit’s power supply output receptacle. When the unit’s 3 output receptacles are insufficient, increase the number of output receptacles by attach- ing a separately purchased power strip.
- Even when the connected device has a 2P AC input plug, it can be connected to the power supply output receptacle. However, when a 2P AC input plug has a ground wire, attach the ground wire to the grounding terminal ( ) on the back of the unit. <When connected device has 3P plug> <When connected device has 2P plug> <When connected device has 2P plug + ground> Plug of connected device yltcerid gulp eht tcennoCyltcerid tcennoCyltcerid tcennoC Plug of connected device Plug of connected device The unit’s power supply output receptacle Front panel facing upward Front panel Front panel Front panel facing downward Vertical (Right side at bottom) Upside downDo not use it in a condition listed below. - Blocking the ventilating hole - Placing objects on the unit - Stacking units (vertically or alongside) Connect the ground wire to the grounding terminal ( ) on the unit <Connection example 1> <Connection example 2> PC PC Separately purchased power strip External HD Modem or other peripheral
- Installation and connection 2-3 Installation and connection (BY75SW) Connection to back up your computer and peripherals (1) Disconnect all computer and peripheral AC input plugs from the wall outlet (commercial power). AC input plug of the unit Plug of connected device Connect it directly. Use the attached 3P-2P Conversion Plug. Attached 3P-2P Conversion Plug Wall outlet (commercial power) Connect the grounding wire to the grounding terminal equipped to the building. (If no grounding terminal is available, a means of grounding must be constructed.) Wall outlet (commercial power) (4) When the installation and connection are complete, connect the AC input plug of this unit to a wall outlet (commercial power). When you connect the AC input plug of this unit to a wall outlet (commercial power), battery charging automatically starts regardless of the on/off state of the Power Switch and charging completes within 12 hours. > teltuo llaw P2 <> teltuo llaw P3 <
- This unit was charged before shipment, but if it is being used for the first time, the backup time may be reduced due to natural discharge. We recommend charging the unit before use. Computer Modem or other peripheral Wall outlet (commercial power)
- Installation and connection (2) Install the unit. Do not use this unit in any position other than the “proper positions” indicated in the illustration below. Write the usage start date on the label on the side. Also, by using the included UPS monitoring software, possible to keep a record of usage start date by the software. Vertical Proper positions Horizontal Improper positions The left surface in on the bottom. The front surface in on the bottom. The back surf ace in on the bottom. * Attach the rubber feet to each of the four corners on the bottom surface of the unit.
- Installation and connection Diagram showing BY75SW mounted with anchor screws
- When attaching the unit to a base plate, take the thickness of the plate cover into consideration when choosing the appropriate screws. Screw diameter: M4 Maximum screw length: 12 mm Maximum tightening torque: 1.57 N/m * Attach the unit to the base plate by threading 4 screws through the temporary screw holes on the unit’s bottom surface. Wall panel (metal) Supporting surfaceBase plate (metal) Attach to wall surface with no supporting surface.Hanging from ceiling (above) Proper positions Improper positions Vertical Horizontal
- Installation and connection (3) Connect devices that require backup to the unit’s power supply output receptacle. A total of up to 750VA (7.5A) or 450W can be connected. If the unit has an insufficient number of power output receptacles, increase the number of output receptacles by attaching a separately purchased power strip. (4) When installation and connection are complete, connect the unit’s AC input plug to a wall outlet (commer- cial power). When the AC input plug is connected to a wall outlet (commercial power), the battery automatically starts charging, taking up to 12 hours to complete. > teltuo llaw P2 <> teltuo llaw P3 <
- E ven when the connected device has a 2P AC input plug, it can be connected to the power supply output receptacle. However, when a 2P AC input plug has a ground wire, attach the ground wire to the grounding terminal ( ) on the back of the unit. AC input plug of the unit Plug of connected device Connect it directly. Use the attached 3P-2P Conversion Plug. Attached 3P-2P Conversion Plug Wall outlet (commercial power) Connect the grounding wire to the grounding terminal equipped to the building. (If no grounding terminal is available, a means of grounding must be constructed.) Wall outlet (commercial power)
- This unit was charged before shipment, but if it is being used for the first time, the backup time may be reduced due to natural discharge. We recommend charging the unit before use. <Connection example 1> <Connection example 2> PC PC External HD Modem or other peripheral Separately purchased power strip
- Installation and connection 2-4 Checking the operation When you are complete with connecting devices to the unit, the backup function must be confirmed. Check that the Battery Mode is performed normally according to the following procedure. This operation check simulates a power failure by disconnecting the AC input plug from a wall outlet.) (1)T urn on the Power Switch of this unit. The beeper sounds and the current settings are displayed on the LED. After 5 secounds, the self-diagnostic test is performed in Battery Mode for approximately 10 seconds. When the self-diagnostic test finishes successfully, switching to AC output from commercial power is per- formed and the following display is obtained. (If the battery voltage is low, the self-diagnostic test is not performed and the operation starts immediately, using output from commercial power.) * Self-diagnostic test is not performed at cold start. (2) Bring all the connected devices into operation. (Including devices connected to the AC outlet of your PC.) Operate the devices in a way in which abrupt power stop does not damage the connected devices, data, etc. (3) Under this condition, check the LED display and a beep of this unit. Are they in the same status as shown below? Are the same as shown above. The operation is normal. Proceed to (4). Are not the same as shown above. The operation is abnormal. One of the description in "4. Display and beeps when there is an equipment failure" of "4-3 Interpreting a beep and display" on page 30 must apply. Take necessary measures and then proceed to (4). (4) Disconnect the AC input plug of this unit from a wall outlet (commercial power). The UPS enters Battery Mode. Status indicator Description Power switch “ON” Operating nor mally Status indicator Beep Power supply output r eceptacles None Outputs power (connected devices ar e powered)
- Installation and connection (5) In Battery Mode, check the LED display and a beep of the unit. Are the LED display in the same status as A or B below? Are not the same as shown above. Operation is abnormal. Check the status of lamps and beep and turn off the Power Switch.
- If the display is one of those shown in “4. Displays and beeps when there is an equipment failure” in “4-3 Interpreting beeps and displays” on page 30, take the necessar y measures and then go back to (1) on page 24.
- If no Battery Mode is performed and the UPS and the connected devices stop, insufficient charging of the battery is suspected. Connect the AC input plug of the UPS to a wall outlet (commer- cial power), charge the battery for approximately 6 hours, and then go back to (4) on page 24.
- If the problem persists after checking the 2 points above, contact the shop of purchase. (6) Connect the AC input plug to a wall outlet (commercial power) again. The Status indicator stops blinking and turns on without intervals, and the beeper stops. (The status is as shown below.) Checking the operation is now complete. Installation and connection is now complete. ( indicates blinking) Status indicator Description Backup is operating due to power failur e or AC input er ror. The battery will be depleted if backup operation continues. (Same as above. ) Battery level is low, so output will stop soon . Battery is dead, so output stopped. (This is displayed only for a few seconds. ) Status indicato r Description Power switch “ON” Operating normally Beep Intermittent 4-second intervals Intermittent 1-second intervals None Output ON ON OFF Charging OFF Discharging OFF Discharging OFF Discharging
- Preparation for operation 3. Preparation for operation 3-1 Charging the battery When you connect the AC input plug of this unit to a wall outlet (commercial power), the battery charg- ing automatically starts regardless of the on/off state of the Power Switch, and it is fully charged within 12 hours. This unit has been charged prior to shipment. However, the backup time becomes shorter when using it for the first time due to spontaneous discharge. We recommend charging this unit before using it. If you do not perform the initial backup time measurement described below in “3-2 Measuring the initial value of backup time”, proceed to “4. Operation”. Page 27 When you measure the backup time initial value of the unit in your environment, this value can be used as a guide when checking the battery and deciding the UPS monitoring software setting values. See also "7. Measuring the backup time" Page 61 The battery is discharged completely when the backup time is measur ed, so you need to recharge it befo re using the UPS. You can use connected devices while recharging the battery, but the backup time when a power failure occurs is shorter until the battery is fully charged. (If a power failure occurs immediately after the start of charging, backup stops immediately.) See also Charge the battery as described in "3-1 Charging the battery." Preparation for starting operation is now complete. 3-2 Measuring the initial value of backup time 3-3 Recharging the battery
- Operation 4. Operation 4-1 Precautions and notes on operation Do not wet or pour water onto the unit.
- Doing so may cause an electric shock or a fire.
- If you wet the unit, stop using it and the unit must be inspected and/or repaired. For repair, contact the shop of purchase. When the battery is dead, replace it immediately or stop using the unit.
- Continuing the use of it may cause a fire or electric shock due to liquid leaks.
- For more on how to check the battery, see “5. Maintenance and inspection” on page 39.
- For more on how to replace the battery, see “5-2 Replacing the battery” on page 40. Wipe the AC input plug clean of dirt with a dry cloth occasionally.
- Settled dust may cause fire or electric shock due to liquid leaks. If you notice abnormal sound or smell, smoke, or leakage from the inside, immediately turn off the power switch and disconnect the AC input plug from a wall outlet (commercial power).
- Using the unit under such conditions may cause a fire.
- If you notice such a condition, stop using the unit and contact the shop of purchase for in- spection and repairs.
- Use the unit under the conditions in which you can immediately disconnect the AC input plug from a wall outlet (commercial power) in the case of an abnormal event. If fluid leaks from the unit, do not touch the fluid.
- Doing so may cause blindness or burns.
- If the fluid contacts your eyes or skin, wash it out with lots of clean water and consult your doctor. Caution (for use) * The values in the table are the expected life under standard use conditions and are not guaranteed. Notes Before stopping the commercial power to the unit, turn OFF the power switch of the unit.
- The unit enters Battery Mode when commercial power is stopped. If you frequently use the unit in Battery Mode, the battery life may be significantly shortened. Ambient temperature Expected life 20°C 4 to 5 years 30°C 2 to 2.5 years
- Operation 4-2 Start and stop procedures and basic operation Explanation Usual operation
- You may either leave the power switch of the unit on (operation status) or turn it off each time when stop- ping the connected system. You can choose either of the operation methods for your convenience. We recommend turning off the power switch when you do not use connected devices for a long time.
- The battery is charged when the AC input plug of the unit is connected to a wall outlet (commercial power). End of Battery Mode
- If a power failure lasts long, the battery discharges and power output from the unit stops. Shut down your computer after performing appropriate procedure (for example, saving data) while the unit supplies power. Reboot
- If the battery discharges completely during a power failure, the unit stops. After recovery from the power failure, the unit automatically restarts and supplies power. If you do not want to restart the connected de- vices, turn OFF the power switch of either the unit or the connected devices while the power is out. It is also possible to deactivate the auto restart by turning ON the auto restart setting (setting switch 2 ). (See page 33.) When the AC input plug is connected to a wall outlet and the power switch is in the OFF position:
- The status indicator displays " ".
- Power output is stopped.
- The battery is charged automatically. Start procedure Operation Turn on the power switch of the UPS.
- The details of the most recent error are displayed. (item 4 on page 30)
- The beeper sounds and the current setting is displayed on the status indicator. Cold start ON/OFF setting Output voltage setting.
- T he status indicator displays “ ”, and the self-diagnostic test is performed in Battery Mode for about 10 seconds. (If the battery voltage is low, the self-diagnostic test is not performed. It is automatically executed after the battery is charged.) * Self-diagnostic test is not performed at cold start.
- W hen the self-diagnostic test finishes successfully, switching to AC output from commercial power is performed and normal operation starts.
- If the self-diagnostic test is not executed, the UPS immediately sta rts outputting AC from commercial power.
- During operation, the battery is charged automatically. Status indicator Beep Power supply output r eceptacles None Outputs power (connected devices ar e powered)
- Operation Operation during a power failure
- If a power failure or abnormal input power supply occurs, the UPS automatically switches to Battery Mode, continuing power output from the Power Supply Output Receptacles supplied from the battery.
- The status is displayed and the beeper sounds intermittently to alert the user. See also Setting switch 1 can be used to turn the beeper ON/OFF. Page 33 Operation during recovery from a power failure
- If a power failure or abnormal power input is resolved while the UPS supplies power, it returns to the commercial power output status automatically. Charging the consumed battery starts.
- If a power failure or abnormal power input is resolved after the batte ry is discharged completely and power output is stopped, the UPS restarts automatically and resumes power output. Charging the con- sumed battery starts. Stop procedure Operation Turn on the power switch of the UPS.
- The power output from the UPS stops.
- Even if you turn off the power switch, if 1AC is supplied from commercial power, the battery is automati- cally charged. Status indicator Battery replacement noituloSnoitpircseDgnigrahCtuptuOpeeB Intermittent 4-second intervals Intermittent 1-second intervals None OFF DischargingON OFF DischargingON OFF DischargingOFF Backup is operating due to power failure or AC input error. The battery will be depleted if backup operation continues. Perform shutdown operations for the connected devices and stop them. (Same as above.) Battery level is low, so output will stop soon. (Same as above.) Battery is dead, so output stopped. (This is displayed only for a few seconds.) Charge the battery. Status indicator Battery replacement Beep Output Charging Description None ONOFF There is AC input Power switch “OFF” ( indicates blinking)
- Operation 4-3 Interpreting beeps and displays Status indicatorNo. Battery replacement noituloSnoitpircseDgnigrahCtuptuOpeeB None None None OFF ON ON OFF OFF ON No AC input Operation stopped — There is AC input Power switch “OFF” Power switch “ON” Operating normally 1. Displays and beeps during normal operation indicates blinking
5 None
—ssergorp ni tset citsongaid-fleS —Auto battery test in progress 2. Displays and beeps while testing
8 None
Backup is operating due to power failure or AC input error. The battery will be depleted if backup operation continues. Perform shutdown operations for the connected devices and stop them. (Same as above.) Charge the battery. (Same as above.) Battery level is low, so output will stop soon. Battery is dead, so output stopped. (This is displayed only for a few seconds.) None None (ON) (ON) OFF OFF AC input voltage or frequency is too high (over) Power switch “OFF” Use within the input voltage/frequency range described in the specifications. (Same as above.) AC input voltage or frequency is too low (under) Power switch “OFF” 3. Displays and beeps during power failure or AC input error Intermittent 0.5-second intervals ON, or DischargingON Reduce the number of connected devices until the display appears as in status No. 3. There are too many connected devices and the rated capacity is exceeded. If this status continues for 5 minutes or more, the status No. 12 occurs and output stops.
12 Continuous ON, or
devices. Reduce the number of connected devices, and then turn ON this unit and the connected devices. Stopped due to excess connection capacity. 4. Displays and beeps when there is an equipment failure
- Operation Status indicatorNo. Battery replacement noituloSnoitpircseDgnigrahCtuptuOpeeB Continuous Continuous ON, or OFF OFF OFF Output stopped due to exceeded connection capacity or a short-circuit with the connected devices. Output stopped due to a failure. When the beep stop switch is pressed, the details of the error are displayed. (No.15 to No.19)
16 Continuous —OFF Output stopped due to output voltage error
(under). Continuous —OFF Output stopped due to battery charge voltage error (over) Continuous —OFF Output stopped due to battery charge voltage error (under) 4. Displays and beeps when there is an equipment failure (continued) indicates blinking Intermittent 2-second intervals ON The battery test detected a weak battery. ON Charge the battery. You can replace the weak battery with a separately purchased replacement battery as needed. Check that the AC input of connected devices is not short- circuited, or that the connection capacity does not exceed the rated capacity.
19 Continuous— OFF Output stopped due to problem with
- Display and beep for battery replacement —————12 Cold start ON setting UPS can start up even when there is no AC input —————22 Cold start OFF setting UPS can start up only when there is AC input Output voltage is 100V (effective value) 6. UPS operation mode setting display Follow the corresponding solutions in boxes No. 15 to 19. There is a problem with this unit, so get it repaired.
15 Continuous —OFF Output stopped due to output voltage error
(over) Turn OFF this unit and all connected devices. Then, turn the power switch back ON for this unit only. If the display does not change, there is a problem with this unit, so get it repaired. If the display does change, it is due to a combination with a connected device. If anything is unclear, contact the the shop of purchase. The cause of this may be that the ambient temperature of the UPS has increased. Check the ambient tempera- ture of the UPS. If it exceeds 40°C, lower the ambient tempera- ture. Turn OFF this unit and all connected devices. Then, turn the power switch back ON for this unit only. If the temperature is lower than 40°C, there is a problem with this unit, so get it repaired.
- Operation 4-4 Suspending a beep You can suspend a beep by pressing and holding the Beep Stop/Test Switch while a beep is sounding for 0.5 second or longer. You can use the following procedure to check whether a failure occurs inside the unit and whether replacing the battery is required. If the battery is not fully charged, the self-diagnostic test is not executed immediately . After charging is complete, it is automatically executed . (1) Connect your computer and other devices to the UPS and then turn on the power switch of the UPS. (2) Press and hold the Beep Stop/Test Switch of the UPS for 0.5 secondsto 9 seconds. The Battery Mode starts for testing purpose. (No beep sounds.) When the test is complete, the normal operation automatically starts. (3) If the status indicator/battery replacement lamp blinks and the beeper sounds: See also "4-3 Interpreting a beep and display" Page 30 Follow the directions for the solutions described in “4. Displays and beeps when there is an equipment failure” and “5. Display and beep for battery replacement”. This UPS provides functions to automatically check whether replacing the battery is required and whether the internal circuit is at fault. (You do not have to perform any operation.) The test is performed at intervals of 4 weeks after the AC Input Plug is connected to a wall outlet (commercial power). The test is not performed if the power switch is OFF or if the battery is not fully charged. (1) When the auto battery test starts, the Battery Mode automatically starts. (No beep sounds.) After the auto battery test is complete, the normal operation automatically starts. (2) If the status indicator/battery replacement lamp blinks and the beeper sounds: See also "4-3 Interpreting a beep and display" Page 30 Follow the directions for the solutions described in “4. Displays and beeps when there is an equipment failure” and “5. Display and beep for battery replacement”. The setting switch on the rear of the UPS allows you to select the "disable the auto battery test" setting . See also "4-7 Changing the setting of the functions" Page 33 See " Auto battery test ON/OFF setting. " 4-5 Description of the self-diagnostic test function 4-6 Description of the auto battery test function Output voltage is 110V (effective value) Output voltage is 115V (effective value) Output voltage is 120V (effective value) 6. UPS operation mode setting display
- Operation 1. Selecting functions with the setting switches Operation After changing the setting switches, turn ON the power switch again while the AC input plug is connected to a wall outlet (commercial power).
- Otherwise, the change will not take effect.
- Use a fine-pointed tool such as a small screwdriver to maneuver the switch’s lever. Power output stop delay time setting (setting switch 1 ) … Factory-shipped setting: OFF OFF: The beeper sounds when an alarm is necessary. ON: The beeper does not sound for backup operation or batte ry replacement. The beeper sounds for other errors (connection capacity exceeded, operation error, etc.). Auto restart setting (setting switch 2 ) … Factory-shipped setting: OFF OFF: Automatically restarts when power is restored. After a power failure occurs and the unit shuts down using the shutdown software or contact signal, the unit automatically starts and begins to output when the commercial power is restored. ON: Does not automatically restart when power is restored. After the unit shuts down using the shutdown softwar e or contact signal, it does not star t up when commercial power is restored. Startup is performed manually by turning the power switch OFF once, and then back ON again. Auto battery test ON/OFF setting (setting switch 3 ) … Factory-shipped setting: OFF OFF: The battery test is automatically executed at intervals of 4 weeks. ON: The auto battery test is disabled. Use this setting to disable Battery Mode in for the regularly performed auto battery test. ON 1 2 53 4 86 7 ON 1 2 53 4 86 7 Setting switch ON Setting switch ON BY75SW (when positioned vertically) BY50FW (when positioned vertically) ON 1 2 56 783 4 4-7 Changing the setting of the functions
- Operation Power output stop delay time setting (setting switches 5 and 6 ) … Factory- shipped setting: OFF and OFF The UPS delays the power supply output stop timing. If the user sets “switch 5: ON, switch 6: ON”, the UPS does not stop the output, even if the backup stop (BS) is valid. ON 1 2 3 4 56 78 ON OFF ON OFF ON AC input BS signal UPS output OFF Power supply output stop delay timing This delay corresponds to the settings for switch 5 and switch 6. This timing is 10 ms or 10 sec. Timing corresponds to the settings for switch 0 second 60 seconds 120 seconds Setting switch 5 Setting switch 6 OFF OFF ON OFF OFF ON ON ON Does not stop power output Power output stop delay time <Note> The remote ON/OFF signal is not related to this setting. When the remote ON/OFF signal is “closed”, the UPS stops the output immediately.
- Operation UPS stop signal setting (setting switch 7 ) … Factory-shipped setting: OFF (Only for BX50FW, BX75SW) OFF: The unit’s power output can be stopped by inputting a “High” backup power supply stop signal (BS) that continues for 10 seconds or more. The power supply output is stopped with a voltage signal input, even in commercial operation. After stopping power output, a “Low” backup power supply stop signal (BS) restarts the unit once the commercial power supply is normal. However, it does not restart if the automatic restart setting (setting switch 2 ) is ON. ON: The unit’s power output can be stopped by inputting a “High” backup power supply stop signal (BS) that continues for 0.01 (10 ms) seconds or more. Power supply output can be stopped when the stop signal is received, only during backup operation (Battery Mode). After stopping power output, a “Low” backup power supply stop signal (BS) restarts the unit once the error that caused the power failure is eliminated. Use this setting in commercial operation when you do not want to stop operations when a backup power supply stop signal (BS) is received. Communication connector 8th-pin output signal switching setting (setting switch 8 ) … Factory-shipped setting: OFF * Valid only when using contact signal interface. ON 1 2 53 4 86 7 OFF: Outputs the BU signal ON: Outputs the BU inversion signal ON 1 2 53 4 86 7 Caution
- Before operating the switching switch, turn OFF the power switch of the main unit and unplug the AC input plug (turn OFF the AC input).
- If the switching switch is changed during operation, communication with peripherals (PC, etc.) will cease to perform normally.
- I f the AC input plug is not disconnected, the switching switch setting changes will not become valid. Use when switching the communication interface (serial communication, contact com- munication). Contact Serial 2. Switching switch AC input BU NBU ON OFF ON OFF ON OFF
- Operation 3-1. The UPS operation mode can be set if the power switch is turned ON while the beeper stop switch is pressed. Note: While in setting mode, output from the output receptacles are OFF, even if the power switch is ON. How to make settings: There are 3 items to select. 1) Cold start ON/OFF setting 2) Output voltage setting) 3) Signal input/output test (1) When the beeper stop switch is briefly pressed (for less than 1 second), the next item is displayed. (2) When the beeper stop switch is pressed and held (for more than 1 second), the unit enters the “individual item setting mode”. (3) When the power switch is turned OFF, setting mode quits and it returns to normal status (Status No.2). 3. UPS operation mode settings The settings available for this operation are shown below.
- Cold start ON/OFF setting When ON, it is possible to start up the unit even when there is no AC input plug. (It is not possible, however, to start up the unit by the remote signals.)
- Output voltage setting (100V/110V/115V/120V) Four types of output voltage can be set for the output voltage during Battery Mode.
- Signal input/output test (BL/TR/BU/WB/BS/remote) Test output can be made for four types of signals. The signal is output without causing an actual power failure or internal malfunction. It is also possible to detect two types of signal input. The signal input from the system can be checked on the LED display . (The unit does not actually stop, because it is in test mode.) Cold start ON/OFF setting Output voltage setting Signal input/output test
- Operation RemoteRemote Remote ON/OFF signal input test (*2) Backup power supply stop signal input test (*2) BL Battery low signal output test (*1) BS <C> <C> <C> <C> <D> <A> <B> <D> <D> <D> <D> <D> ON 100V <C> 110V OFF <D> <D> 115V <D> <D> 120V <D> TR Trouble signal output test (*1) <D> BU Backup signal output test (*1) <D> WB <D> Cold start ON: The unit can start up even when there is no AC input Output 100V mode Output 110V mode Output 115V mode Output 120V mode Cold start OFF: The unit can start up only when there is AC input Normal status There is AC input (when athe status indicator is ON) Power switch “OFF” (Status No. 2) Cold start ON/OFF setting Output voltage setting Signal input/output test Setting mode JOEJDBUFTCMJOLJOH Battery replacement signal output test (*1) Signal output Signal output Signal output Signal output Signal input Signal input *1 The signal has not been output yet. The signal is output by holding the beep stop switch for at least 1 second. *2 The signal has not been accepted yet. Blinking of the indicator after the signal has been input to the UPS indicates that the UPS accepted the signal. <C><C>
- Operation (A) Turn ON the power switch while the beeper stop switch is pressed. (B) Turn OFF the power switch. (C) Press and hold the beeper stop switch (for more than 1 second). (D) Press the beeper stop switch (for less than 1 second). (E) Input a signal to the UPS. (F) Stop the signal. Output signal Input signal Battery Low signal (BL) (Between pins 1 and 5) Trouble signal (TR) (Between pins 2 and 5) Backup signal (BU) (Between pins 8 and 5) Deteriorated battery signal (WB) (Between pins 9 and 5) Backup power supply stop signal (BS) (Between pins 3 and 5) Remote ON/OFF signal (Between pins 6 and 7) While the signal is being input, these status indications blink and the beep sounds. Beep Signal input/output test start ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF Signal output test Contact signal is forced to turn ON. Signal input test While the signal is being input, the status indicator blinks and the beep sounds. Signal input/output test end Signal input/output test (BL/TR/BU/WB/BS/remote) Four types of output signal can be forcibly turned ON. The ON/OFF state of two types of input signal can be checked with the status indicator and the beeper.
- Maintenance and inspection The sealed lead battery used in the unit has a limited life. (The life varies depending on your storage/use environment and backup frequency.) The nearer the end of the life is, the more rapidly deterioration proceeds. 1. Life of battery (estimated replacement timing) 2. Method to check the battery There are 3 methods for checking the battery.
- Perform a self-diagnostic test. (See page 32.)
- Use the auto battery test function. (See page 32.)
- Measure the backup time. (See page 47.) By measuring the backup time, the battery life can be determined more accurately. See also Measure the backup time according to "7-1 Measuring method of the backup time." Page 61 If the measured value is equal to the "initial value of the backup time" or less than half the value obtained from the graph of "Estimated backup time" on page 60, replace the battery.
- When you compare the "initial value of the backup time" you measured and the current backup time, make the capacity of devices connected to the UPS same as when you measured the initial value to make judgment accurately. 3. Guideline on the frequency of checking the battery (measuring the backup time) * The battery deteriorates even if it is stored. The higher the temperature is, the shorter the life becomes. Ambient temperatur e 20°C 30°C Life of battery 4 to 5 years 2 to 2.5 years Replacement estimatio n 4 to 5 years after staring us e 2 years after staring us e Ambient temperatur e 20°C 30°C Check at intervals of 6 months Until 3 years from purchas e Until 1.5 years from purchas e Check at intervals of 1 mont h From after 3 years From after 1.5 years When maintaining the connected equipment, turn OFF the power switch and disconnect the AC input plug.
- The backup function continues to supply power from the power output receptacles while the UPS is operating, even when the AC input plug is disconnected. Do not disassemble, repair, or modify the unit.
- Doing so may cause an electric shock or a fire. If fluid leaks from the unit, do not touch the fluid.
- Doing so may cause blindness or burns.
- If the fluid contacts your eyes or skin, wash it out with lots of clean water and consult your doctor. Do not throw the unit into fire.
- The lead battery in the unit may explode, or leak dilute sulfuric acid. 5. Maintenance and Inspection Caution (maintenance) 5-1 Checking the battery
- Maintenance and inspection The battery can be replaced either while the unit is stopped (power supply output stopped) or while it is in operation (outputting power supply). * When replacing the battery, stop the connected devices, turn OFF the power switch of the UPS, and disconnect the AC input plug fr om the wall. *I f an input power supply error such as a power failure occurs when replacing the battery while in opera- tion, backup cannot be perfor med and output stops. *D o not replace the battery during backup operation. Output will stop . Caution When the unit is used in compliance with UL standards, do not replace the battery while in operation (while power is being output). Replacing the battery while in operation does not comply with UL stan- dards. Make sure to stop the operation of the unit befo re replacing the battery. 5-2 Replacing the battery Perform replacement on a stable and flat place.
- Handle the battery carefully not to drop it.
- Not doing so could cause injury or burns due to liquid (acid) leakage. Use a specified battery for replacement.
- Not doing so may cause a fire.
- Product model: BXB50F (battery pack for BY50FW) BXB75S (battery pack for BY75SW) Do not replace the battery in a place where there is flammable gas.
- Spark may occur when connecting the battery, which may cause an explosion or fire. If fluid (dilute sulfuric acid) leaks from the battery, do not touch the fluid.
- Doing so may cause blindness or burns.
- If it contacts your eyes or skin, wash it out with lots of clean water and consult your doctor. Do not disassemble or modify the battery.
- Doing so could cause dilute sulfuric acid leak, which could cause blindness and burns. Do not drop the battery or do not give strong impact on it.
- Dilute sulfuric acid may leak. Do not short the battery with metal objects.
- Doing so could cause an electric shock, fire or burn.
- Some electrical energy still remains inside the spent battery. Do not put the battery into fire or do not break it.
- The battery may explode or leak dilute sulfuric acid. Caution (for battery replacement)
- Maintenance and inspection
- A battery can present a risk of electrical shock and high short circuit current.The following precautions should be observed when working on batteries: 1) Remove watches, rings, or other metal objects from the hands. 2) Use tools with insulated handles. 3) Wear rubber gloves and boots. 4) Do not lay tools or metal parts on top of batteries. 5) Disconnect charging source prior to connecting or disconnecting batteries terminals.
- Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions. Keep unauthorized personnel away from batteries. Do not dispose of batteries in a fire. The batteries may explode. Dispose of used batteries according to the instructions. Do not open or mutilate batteries. Released electrolyte is harmful to the skin and eyes. It may be toxic. Caution (for battery replacement) Protéger les batteries du feu. Risque d’explosion des batteries. Utilisez les batteries conformément aux instructions. Ne pas ouvrir ni détériorer les batteries. Les fuites d’électrolyte sont dangereuses pour la peau et les yeux. Les batteries peuvent présenter un risque de choc électrique avec un fort courant de court circuit. Les précautions suivantes doivent être suivie lors de l’intervention sur les batteries : a: retirer les montres, bagues et autre objets en métal b: Utilisez des outils a manche isolé c: Utilisez des gants et des chaussures isolant d: Ne pas laisser des outils ou des objets métalliques proches des batteries e: Déconnecter le chargeur avant de connecter ou de déconnecter les batteries f: Determiner si la pile est mise a la terre. Si elle est mise a la terre, effectuer la deconnection. Le contact avec une pile mise a la terre peut creer un choc electrique. Ceci sera reduit si cette mie a la terre est supprimee pendant installation et maintenance. Attention
- Maintenance and inspection Notes Battery recycling This unit uses lead acid batteries. The lead acid batteries are precious recyclable resources. Please cooperate recycling. For information on recycling, please contact the shop of purchase. Preparation (1) Purchase a BXB50F spare battery pack (sold separately). (2) Remove any objects that are on this device when replacing the battery. Replacing the battery (BY50FW) (1) Open the front panel. Disconnect the red and black connectors. If the connectors have a locking mechanism, lift the lock hook on the front or back of the connector, and with the lock off, disconnect the connectors. Hold one connector in each hand and pull them apart. (1) Slide the fr ont metal cover to the right, and (2) Pull it toward you to remove it. Use a screwdriver to remove the screw (1). Detach the front panel. (2) Disconnect the battery connector and remove the metal cover. Lock hookLocking mechanism 5-2-1 Battery replacement procedure (BY50FW)
- Maintenance and inspection Pull on the white label attached to the battery, and then hold the battery with your hands to remove it. Be careful not to drop the battery. Insert the new battery. (4) Reattach the metal cover and connect the connectors.
- Y ou may hear a “pop” sound when you connect the battery if it is replaced after the unit’s operation is stopped, but this is not abnormal. Fit the metal cover into the grooves and slide it to the left to secure it. (The battery is secured inside the case.) Connect the red and black connectors. (5) Reattach the front panel. Fit the left side of the panel on the case, and then attach it. Tighten the screw with a screwdriver to secure the front panel. Do not remove the battery by holding the cables. Caution (3) Remove the old battery, and insert the new battery. Battery replacement is complete. Make sure that the connectors are securelyconnected. If the connectors have a locking mechanism, make sure the lock hook is completely inserted into the connector and locked in place.
- Maintenance and inspection <After replacing the battery during operation...> r <After replacing the battery when operation was stopped...> Connect the AC input plug to a wall outlet (commer cial power) and turn ON the power switch of the UPS. When operation starts, the self-diagnostic test is automatically performed. Normal operation resumes after the 10-second test. Preparation (1) Purchase a BXB75S spare battery pack (sold separately). (2) Remove any objects that are on this device when replacing the battery. Replacing the battery (BY75SW) (1) Open the front panel. Loosen and remove the 2 screws.D etach the front panel. Pull the front panel upwa rd a little if the front panel is hard to detach. (1) Slide the front metal cover upward, and (2) Pull it toward you to remove it. (2) Disconnect the battery connector and remove the metal cover. Write the usage start date on the label on the top side. Also, by using the included UPS monitoring software, possible to keep a record of usage start date by the software. If the battery replacement indicator is displayed and the beeper sounds before replacement, press the beeper stop/test button once to stop the beeper, and hold it for 5 - 9 sec. to perform a self-diagnostic test. The beeper stops and normal operation resumes after the 10-second test is complete. Disconnect the red and black connectors. Hold one connector in each hand and pul l If the connectors have a locking mechanism, lift the lock hook on the front or back of the connector, and with the lock off, disconnect the connectors. them apart. Lock hookLocking mechanism 5-2-2 Replacing the battery (BY75SW)
- Maintenance and inspection (3) Hold the label stuck to the battery pack and remove it. Insert the new battery pack. Do not remove the battery by holding the cables. Caution (4) Reattach the metal cover and connect the connectors. You may hear a “pop” sound when you connect the battery if it is replaced after the unit ’s operation is stopped, but this is not abnormal. Pull on the white label attached to the battery, and then hold the battery with your hands to remove it. Be careful not to drop the battery. Insert the new battery pack. Fit the metal cover into the grooves and slide it downward to secure it. (The battery is secured inside the case.) Connect the red and black connectors. Make sure that the connectors are If the connectors have a locking mechanism, make sure the lock hook is completely inserted into the connector and locked in place. securely connected.
- Maintenance and inspection 5-3 Cleaning If the battery replacement indicator is displayed and the beeper sounds before replacement, press the beeper stop/test button once to stop the beeper, and hold it for 5 - 9 sec. to perform a self-diagnostic test. The beeper stops and normal operation resumes after the 10-second test is complete. (5) Fit the front panel. Turn the 2 screws to secure the font panel clockwise with a screwdriver. .swercs 2 eht nethgiT.lenap tnorf eht tiF <After replacing the battery during operation...> <After replacing the battery when operation was stopped...> Connect the AC input plug to a wall outlet (commer cial power) and turn ON the power switch of the UPS. When operation starts, the self-diagnostic test is automatically performed. Normal operation resumes after the 10-second test. Cleaning the UPS Wipe the UPS lightly by tight squeezed soft cloth soaked with water or detergent Do not use chemicals such as thinner and benzene. (They cause deformation or discoloration.) Removing dust from the unit’s AC input plug
- T urn off connected devices and the Power Switch of the UPS.
- Disconnect the AC Input Plug from a wall outlet (commercial power) and remove dust around the plug with a dry cloth.
- D isconnect the AC Input plugs of the connected devices from the UPS and clean them also.
- Connect the AC Input plugs of the connected devices to the UPS again, and connect the AC Input Plug of the UPS to a wall outlet (commercial power). (For information on the connection procedure:) See also "2-2 Installation and connection" Page 18 Write the usage start date on the label on the side. Also, by using the included UPS monitor- ing software, possible to keep a record of usage start date by the software. Battery replacement is now completed.
- Using the UPS monitoring software and contact signal [Explanation of software functions]
1 Auto shutdown The computer can be shut down automatically when a problem occurs with the
power supply. 2 UPS monitoring (operating status) The operating status of the UPS can be monitore d (in Commercial Power Mode/ Battery Mode). 3 UPS monitoring (data) Monitoring can be performed for input voltage value, connection capacity, battery capacity, etc.
4 Pop-up notification When a problem such as a power failure occurs, a pop-up window that shows the
details of the problem can be displayed. 5 Shutdown when OS is inactive Shutdown can be performed when the computer is in an inactive state. The operat- ing status is retained at shutdown in inactive state, so operation details ar e not lost.
6 Auto file save Files such as open Word and Excel documents are automatically saved at shut-
down. 7 Schedule operation Schedule settings can be made for UPS stop/start. 8 UPS setting change UPS settings (beep ON/OFF , etc.) can be changed. (Items that can be set vary according to the UPS.) 9 External command execution By executing commands at shutdown, items such as application pr ograms can be launched.
10 Event log save Information of events that occur on the UPS (power supply problems, setting changes,
occurrences of failure, etc.) are saved as a log. 11 Data log save Data of input/output voltage value, connection capacity, etc. is periodically saved as a log (the save frequency can be set).
12 Coordinated shutdown When a problem occurs with the power supply, multiple computers connected to
the UPS can coordinate to perform auto shutdown. 13 Output receptacle control The UPS output receptacles can be individually set to ON/OFF. (This is function is available only for BN100XR/BN150XR/BN240XR/BH60PCW/BH100PCW.) 14 Redundant power supply supportT wo or more UPS can be connected to computers equipped with redundant power supply. Shutdown is not performed when a power supply problem affects only one of the units. Shutdown is not performed when a power supply problem affects only one of the units. Shutdown is performed only when a power supply problem occurs with both UPS, so the system’s operating rate is improved. 15 Remote UPS management The UPS can be managed remotely from a computer on the network. e h t g n i b i r c s e d l i a m e n oi t a c i f i t o n a , s r u c c o e r u l i a f r e w o p a s a h c u s m e l b o r p a n e h Wd n e s l i a M 6 1 problem can be sent to the system administrator. * If you do not use the UPS monitoring software or contact signal, you can disregard this section. The following UPS monitoring softwar e is included with the BY50FW/BY75SW: PowerAct Pro (for Windows/ Linux), UPS service driver, and UPS Power Manager (for Mac). Choose which one to use based on the applica- tion. For the latest support, please visit our site. Support for OS You can download the latest software at: 6. Using the UPS monitoring software and contact signal 6-1 Selecting the UPS monitoring software
- Using the UPS monitoring software and contact signal PowerAct Pro” UPS monitoring software Using the included “PowerAct Pro” UPS monitoring software allows you to automatically save files and shut down your computer when a power failure occurs. The schedule settings also allow you to perform your required operations, such as the UPS auto startup, auto stop, etc. * However, make settings so that the amount of time fr om the occurrence of the power failur e until com- puter shutdown is complete is less than the backup time measu red in “7-1. Measuring the backup time” on page 61. For more details, refer to the instruction manual and online help for the UPS monitoring software. When using PowerAct Pro 1. Connect the UPS to a computer. Cable: The included serial communication (RS-232C) cable or USB communication cable * The serial communication cable and USB cable cannot be used at the same time. 2. Install the included UPS monitoring software on the computer. Software to install: PowerAct Pro How to install: Refer to the separate “UPS monitoring software quick installation guide”. SER. BY50FW USB port Connector Connect to USB terminal Connect to USB port on PC Included USB communication cable Connector Connect to USB port on UPS BY50FW Connector Connect to RS-232C port on PC Included serial communication RS-232C cable Connector Connect to RS-232C terminal Connect to the UPS serial communication interface (RS232C) port BY75SW USB port Connector Connect to USB terminal Connect to USB port on PC Included USB communication cable Connector Connect to USB port on UPS BY75SW Connector Connect to RS-232C port on PC Included serial communication RS-232C cable Connector Connect to RS-232C terminal Connect to the UPS serial communication interface (RS232C) port (1) USB connection (2) RS232C connection 6-2 When using the included UPS monitoring software
- Using the UPS monitoring software and contact signal Explanation Operation start using the UPS monitoring software during scheduled stop If the unit starts operation during a scheduled stop period, the next set scheduled ON operation is cancelled after the power switch is turned OFF. Auto restart after OS shutdown by UPS monitoring software In the event of a power failur e, some PC models (see Note 1 below) automatically r estart immediately after the completion of the OS shutdown processing by the UPS monitoring software. In this case, the unit stops during restart or after startup, possibly damaging files and/or the hard disk. This problem can be avoided by disabling POWER MANAGEMENT in the BIOS settings. *1) PC models: This problem has been reported with MICRON Millennia Mme. When the PC does not start up automatically, select the “System startup at power restoration” setting (example: “Restore On AC/Power Loss) in the BIOS settings of your PC, and change to a “System startup after power restoration” setting (example: Power On). Individual BIOS setting methods and/o r displays may differ depending on the PC. For more information, refer to your PC instruction manual or the technical support center for your PC. When considering a system with automatic startup at power restoration, choose a PC that satisfies th e condition shown below. For more information on PC operation when input power is supplied, consult your PC instruction manual or contact the PC technical support center. <Condition> Without pressing the power switch, the PC starts up when input power is supplied. After shutdown processing in the event of a power failur e, the unit restarts automatically and supplies power once power is restored. If you do not want the devices connected to start up, turn OFF their switches while the power is out. The automatic restart setting can also be disabled in the included UPS monitoring software.
- Using the UPS monitoring software and contact signal “UPS Power Manager” UPS monitoring software for Mac When using Macintosh computers such as Xserve, the included “UPS Power Manager” UPS monitoring software enables you to automatically shut down the system when power failures or other input power supply problems occur. * Compatible with Macintosh computers equipped with PowerPC CPU only. When using UPS Power Manager “UPS monitoring software for Mac” 1. Connect the UPS to a computer. Cable: Included USB communication cable 2. Install the included UPS monitoring software on the computer. Software to install: UPS Power Manager How to install: Refer to the separate “UPS monitoring software quick installation guide”. SER. BY50FW USB port Connector Connect to USB terminal Connect to USB port on PC Included USB communication cable Connector Connect to USB port on UPS BY75SW USB port Connector Connect to USB terminal Connect to USB port on PC Included USB communication cable Connector Connect to USB port on UPS (1) USB connection
- Using the UPS monitoring software and contact signal When using the included “UPS service driver”, the OS standard UPS service in Windows Server 2003/XP/2000 can be used. When there is a power failure, files can automatically be saved and the computer can be shut down. 1. Connect the UPS to a computer. Cable: Included connection cable (serial communication or USB) * The serial communication cable and USB cable cannot be used at the same time. 2. Install the included “UPS service driver” on the computer. Software to install: UPS service driver How to install: Refer to the “UPS monitoring software quick installation guide” and the “UPS driver Ver. 3.3 instruction manual” on the CD-ROM. SER. BY50FW USB port Connector Connect to USB terminal Connect to USB port on PC Included USB communication cable Connector Connect to USB port on UPS BY50FW Connector Connect to RS-232C port on PC Included serial communication RS-232C cable Connector Connect to RS-232C terminal Connect to the UPS serial communication interface (RS232C) port BY75SW USB port Connector Connect to USB terminal Connect to USB port on PC Included USB communication cable Connector Connect to USB port on UPS BY75SW Connector Connect to RS-232C port on PC Included serial communication RS-232C cable Connector Connect to RS-232C terminal Connect to the UPS serial communication interface (RS232C) port (1) USB connection (2) RS232C connection 6-3 When performing auto-save functions using the UPS service in Windows Server 2003/XP /2000 + included UPS service driver
- Using the UPS monitoring software and contact signal Click Click When using in combination with the optional BUC26 cable, the OS standa rd UPS service in Windows Server 2003/XP/2000/NT can be used. When there is a power failure, the computer can be shut down. 1. Connect the UPS to a computer. Cable: Connection cable (BUC26), sold separately * Set the switching switch on the back of the unit to “contact”. BY75SW Connector Connector Connect to RS-232C port on PC BUC26 cable Connect to RS-232C terminal Connect to the UPS serial communication interface (RS232C) port BY50FW Connector Connect to RS-232C port on PC BUC26 cable Connector Connect to RS-232C terminal Connect to the UPS serial communication interface (RS232C) port 2. Perform UPS service setup. You need to make Windows settings in order to perform auto shutdown. There is no need to install software. <When using the Windows Server 2003/XP/2000 standard UPS service > Start up the computer after connecting it with the UPS. Perform "Log on to Windows" as the Administrator. After logging on, follow the instructions below to set up the UPS service. How to set up UPS service (shut down Windows when low battery level is detected) 1) Double-click the "Power supply options" icon in "Control Panels". 2) Click the "UPS" tab in the "Power supply options" window. Click the "Select (S)" button. 6-4 When performing auto-save functions using the standard UPS service in Windows Server 2003/XP/2000/NT
- Using the UPS monitoring software and contact signal Click Click Click Click Click Check Check 3) Click the button on the right of the "Select manufacturer (S)" window, and select "General" from the list. Click on "Custom" in the "Select model (M)" window. Click the button on the right of the "Port (P)" window, and select from the list the port that the UPS is connected to. (In the example screen below, the UPS is connected to COM1.) Click the "Next (N)" button. 4) In the UPS signal polarity box, click on the boxes to the right of “Power supply failure/battery drive (P)” and “Low battery (L)” signals to insert check marks. Set the polarity for each signal to “Negative”. Click the “End” button. Click 5) Click the "OK" button in the "Power supply options" window. Setup is complete.
- Using the UPS monitoring software and contact signal Check Click Set 2) In the "Warning" box, place a check mark in the box to the left of "Time fr om when battery drive starts until warning is issued (M)" by clicking on it. In the window to the right, set the amount of time to wait before starting Windows shutdown after a power failure occurs. (Setting range: 2 to 720 minutes) Click the "OK" button. Click When a power failure occurs, Windows shutdown starts once the low battery level signal is detected. If the power is restored before the low battery level signal is detected, Windows shutdown does not start and the normal monitoring state is restored. Recycling and Discarding the Battery In the Windows Server 2003/XP/2000 UPS service, there is no function to stop the UPS. After Windows is shut down, manually turn OFF the unit's power switch. Stopping the UPS <How to set up UPS service (set the time to shut down Windows) > 1) After performing the setup described in the previous section, click the "Configure (C)" button in the "Power supply options" window.
- Using the UPS monitoring software and contact signal 3) Click the "OK" button in the "Power supply options" window. Setup is complete. When a power failure occurs, Windows shutdown starts once the set time is exceeded or the low battery level signal is detected. If the power is restored before the set time is exceeded, Windows shutdown does not start and the normal monitoring state is restored. <When using the Windows NT standard UPS service> 1) Double-click the "UPS" icon in "Control Panels". 2) Insert a check mark in the checkbox to the right of "Port where UPS is installed (U)..." by clicking on it. In the setting field, select the number of the serial port (COM1 to 4) the unit is connected to. 3) Insert check marks in each of the checkboxes to the left of "Power failure signal", "Low battery level signal" and "Remote uninterruptible power source shutdown signal" by clicking on the boxes. Set each signal interface voltage setting as shown below. - Power failure signal (P) ... Negative - Low battery signal (L) ... Negative - Remote uninterruptible power source shutdown (R) ... Positive Check Check Set Please note that in the case of incorr ect interface voltage signal settings, Windows NT will not receive the signal from the UPS and the UPS will not stop when there is a power failure. Failure to put check marks in the boxes will lead to the same result. Note Click
- Using the UPS monitoring software and contact signal 6-5 Using the Contact Signal You can develop your unique system based on the following specifications to automate the process at the power failure. You can perform power failure and shutdown processing by allowing the system to detect the backup signal and low battery level signal, or you can use the trouble signal to perform failure notification. You can stop the UPS by inputting the UPS Stop Signal from the system, and remote control start and stop of the UPS by using the Remote ON/OFF Signal. Also, this function is valid only when “connection communication” is selected for the “switching switch”. (See item 2 on page 35.) 1. Signal output The UPS has 5 kinds of output signals. The output circuit consists of an open collector circuit using a photo coupler (a kind of electronic switch). Backup Signal output: BU Low battery level signal output BL Goes ON when the battery becomes weak during the Battery Mode. Trouble Signal output: TR Goes ON when an internal failure of the UPS occurs. Battery Replacement Signal output (WB) Turns ON when battery deterioration is detected. BU-COM ON when a power failure occurs BL-COM ON when low battery level is detected TR-COM ON when an internal failure occurs WB-COM ON when battery deterioration is detected Click 4) After the settings are made, double-click the "Service" icon in "Control Panels". 5) Select the UPS service and click the "Start" button. By starting the alerter service, messenger service, and event log service in advance, the UPS service sends warning messages to the user and records a history of events such as power failures when they occur. When a power failure occurs, Windows shutdown is performed once the low battery level signal is detected. If the power is restored before the low battery level signal is detected, Windows shutdown is not performed and the normal monitoring state is restored.
- Using the UPS monitoring software and contact signal External contact Operate Open Start Close Stop BS-COM UPS stops2. Input of the UPS Stop Signal (BS) Stops the output of the UPS after the time period specified by the “power output stop delay time setting” (setting switches 5 and 6 ) has elapsed. (1) When the "UPS Stop Signal setting" (setting switch 7 ) is set to OFF: You can stop the output of the UPS by inputting the voltage signal (HIGH) that lasts at least 10 seconds from the outside. (2) When the "UPS Stop Signal setting" (setting switch 7 ) is set to ON: You can stop power output by inputting the voltage signal (HIGH) that lasts at least 0.01 second (1 0 ms) from the outside that is accepted only during backup. See also "4-7 Changing the setting of the functions" Pages 33 3. Remote ON/OFF Signal You can start and stop the UPS by the remote ON/OFF signals, by the contact connected to the outside, or the ON/OFF status of the open collector circuit. To use this function, turn on the Power Switch of the UPS. (Note: It is not possible to start up the UPS with the remote ON/OFF signal when there is no AC powe r supply, even when cold star t is set to ON.) 4. Connection to the system Please make a cable to connect to the system by yourself. See also "9. Example of the use of the Contact Signal circuit" Page 60 5. Contact Signal Connector (female DSUB9P) Front view Screw size: inch screw #4-40 UNC Pin assignment Pin number Signal name 1B L 2T R 3 BS 5C OM
6 Remote ON/OFF (–)
7 Remote ON/OFF (+)
- Using the UPS monitoring software and contact signal Connector Connect the remote ON/OFF connector included with the product. 6. Remote ON/OFF connector (female) (1) Connect the connector: FUPS Shutdown Disconnect the connector: FUPS Start-up (2) The corresponding warning Remote ON (+) Remote OFF (--) 10VBL TR BU/NBU BS COM 820 Ω WB Front view Screw size: Inch screw #4-40 U N C Pin assignment Pin numberS ignal name
1 Remote ON/OFF (+)
2 Remote ON/OFF (--)
- Contact Signal ratings Signal output (BL, TR, BU/NBU, WB) UPS Stop Signal input (BS) CDV 51 ot 5HGIHegatlov tupnIsgnitar relpuoc otohP ssel ro CDV 7.0WOLssel ro CDV 53:egatlov elbailppA Maximum current: 10 mA Remote ON/OFF Voltage between terminals: 10 VDC Current when closed: max.10 mA 8. Contact Signal circuit inside the UPS Note) Input current HIGH 5 to 12 mA
- Using the UPS monitoring software and contact signal 9. Example of the use of the Contact Signal circuit Example of the use of the BU signal Example of the use of the BS signal Example of remote ON/OFF BU COM 12V 1K Ω System side To port on PC UPS side TLP627 Connecting cable (twisted or shielded) Remote ON/OFF circuit Notes When connecting a device that generates counter electromotive force to the signal output circuit such as a relay, connect diodes to prevent counter electromotive force at the both end of the relay. Explanation When power is restored after the unit stopped automatically during a power failure, the unit automatically restarts and supplies power. If you do not want to start the connected devices, turn OFF their switches or set the auto restart setting (setting switch 2 ) to ON while the power is out. (See page 33.) 10. Precautions and notes on the use of the Contact Signal GND BS COM System side C2458 12V 1KΩ 1.2KΩ TLP521 From port on PC Connecting cable (twisted or shielded) UPS side
- Measuring the backup time (checking the discharge time of the battery) 7. Measuring the backup time (Checking the discharge time of the battery) (1) Connect the AC Input Plug of the UPS to a wall outlet (commercial power) and charge it for approximately 12 hours. If you operate the UPS for 12 hours or more, it is charged. If a power failure occurred during this period, charge it again. (2) Turn ON all devices connected to the power output to be “backed up during a power failure”. (Including devices connected to the AC outlet of your computer.) Operate them in a way in which it is allowable that power supply to the connected devices stops. For Windows Server 2003/XP/Me/2000/Windows NT/Linux/Mac: To be performed in case of hard drive stops. For Windows 98/95: Choose Shut Down of Windows and follow the procedure below to shut down your OS. Choose "Restart in MS-DOS mode" to exit from OS and display the MS-DOS mode screen. (3) Disconnect the AC Input Plug of the UPS and measure the backup time. Measure the time until the unit automatically stops and all displays disappear with the plug disconnected. * The backup time you measure for the first time after purchase is the "initial value of the backup time." The backup time varies depending on the capacity of connected devices. After calculating the total capacity of connected devices, r efer to the graph of the backup time to obtain an estimation of the initial value of the backup time. (This is also applied to checking the battery.) (1) Unify the total capacity (power consumption) of connected devices to W (Watt). For the indication of connected devices, check your computer and the rear of the display. There are 3 types of indication: VA (Volt·Ampare) indication, A (Ampare) indication, and W indication. Example 1) 100 VAC, 50/60Hz, 145 W Example 2) 100 VAC, 50/60Hz, 1.8 A Example 3) 100 VAC, 50/60Hz, 150 VA For devices that use the VA or A indication, conver t the capacity into W. Multiply the value indicated on devices by the value in the right table for conversion. (When the power factor is unknown, enter “1”. The power factor usually ranges between 0.6 and 1.) (2) Add the values converted into W to obtain the total capacity of the connected devices. IndicationV alue VA × power factor = W A × power factor × 100 = W 7-1 Measuring method of the backup time 7-2 Estimated backup time
- Measuring the backup time (checking the discharge time of the battery) (3) Calculate the initial value of the backup time for the total capacity of the connected devices from the graph below. Graph of backup time (initial value for product that has not been used) The smaller the capacity of connected devices becomes, the longer the backup time becomes. Connection capacity (total capacity) (W: Watt) <Reference diagram> Backup time (min.) 120 180 180 270 240 360 300 450 : BY50FW : BY75SW 3.5 BY50FW BY75SW Backup time (20˚C, initial value)
- Troubleshooting 8. Troubleshooting UPS does not operate. The LED display does not light up, even though the AC input plug is connected to a wall outlet (commercial power) and the power switch is ON. Backup is not possible. The computer stops when a power failure occurs. Backup is performed too frequently. Frequent switching is performed although a power failure does not occur. You hear the sound of switching. The display is abnormal. The display is unstable. White lines occur. Noise increases. The battery replacement lamp blinks and the beeper sounds at 2-second intervals. The status indicator shows “ ”, and the beeper sounds at 0.5-second intervals. The status indicator blinks “ ”, and the beeper sounds continuously. Perform the checks shown below if the unit is operating abnormally. If the unit continues to operate abnormally, please contact the shop of purchase. Problem 1. Check that the AC Input Plug is connected to the commercial power securely. 2. The AC Input Overcurrent Protection worked and opened. (If the black button is popped up, it is suspected that there are too many connected devices or there is a short in connected devices.) Disconnect all of the connected devices, push in the AC Input Overcurrent Protection Black Button, and turn on the Power Switch of the UPS again. If the status indicator does not display normally, there is a problem with the UPS. (See "Interpreting a beep and display" on page 30.) 3. Isn't the voltage of the wall outlet (commercial power) too low? Stop devices that consume a lot of power such as an air conditioner. Check the UPS, for example, by connect it to a wall outlet (comme rcial power) in another room or house. (It does not operate when the voltage is less than 90V.) Isn't charging insufficient? Perform the test after charging the battery for at least 12 hours. You can charge the battery by connecting the AC input plug of the UPS to a wall outlet (commercial power).) 1. The input power supply may be at fault. Connect the UPS to a wall outlet (commercial power) in another room or, if possible, another house and check it. Or, stop large devices such as a cooler. 2. Is a page printer (laser printer, etc.) connected? Because large current flows instantaneously in printers, normal backup is not possible. 1. The UPS generates some noise when performing backup. For displays susceptible to noise, distortion or white lines may occur, but the UPS is not at fault. 2. Grounding the UPS, computer, and display may improve this problem. The battery is judged to be dead in the auto battery test or the self-diagnostic test. Battery Mode cannot be performed and therefore replace the battery pack. There are too many connected devices. There are too many connected devices. Reduce the number of connected devices until “ ” is displayed on the status indicator. The UPS stopped because too many devices we re connected for 3 minutes or mor e, or because 120% was exceeded. Turn OFF all power to the unit and connected devices, and reduce the number of connected devices. Then, turn the power to the unit and connected devices back ON and check whether " " is displayed on the status indicator. Check and remedy
100V + 5% 110V mode 110V + 5% 115V mode 115V + 5% 120V mode 120V + 5% WS57YBWF05YB Method Operation method Connectable devices Input voltage range Frequency A 11A 5.7tnerruc mumixaM 100 / 110 / 115 120 VAC 100 to 120 VAC100 to 120 VAC 7.5 to 6.25 A5 to 4.2 A W054/AV057W003/AV005 approx. 6kg approx. 9kg 287 x 330 x 45 90 x 322 x 298 20W 40W 3.5 minutes or more 5 minutes or more 12 hours Nominal output voltage Output capacity *1 Voltage (effective value)*2 Switching time Backup time*3 Type Charging time Operating ambient temperature Expected lifespan Operating ambient humidity Full-time commercial power supply method PC, display, and peripherals Nominal input voltage 50/60Hz±4Hz 50/60Hz±1Hz 50/60Hz±1Hz Nominal output current Waveform (In Commercial Power Mode/Batttery Mode) Sine wave / Shine wave 8 msec. or less Nominal output frequency Compact sealed lead battery 0 to 40°C (during operation)/ -15 to 40°C (during storage) battery fully charged and with no condensation 25 to 85%RH (during operation)/10 to 90%RH (during storage) Input Output Battery Environment External dimensions (W x D x Hmm) Weight of UPS Internal power consumption (Normal, Max.) (During backup operation) 4 to 5 years (at ambient temperature of 20°C) 100V mode 86 + 4 to 114 + 4 VAC 110V mode 96 + 4 to 124 + 4 VAC 115V mode 101 + 4 to 129 + 4 VAC 120V mode 106 + 4 to 134 + 4 VAC 100V mode 100V + 5% 110V mode 110V + 5% 115V mode 115V + 5% 120V mode 120V + 5% (During backup operation) Note 1: Make sure that both the VA value and the W value of the load capacity connected to the UPS are within the range specified here. Note 2: The power supply abnormality detection voltage can be changed in the UPS operating mode settings. Note 3: When rated load is connected, at 20°C, and for initial characteristics. References A. Specifications
B. Related products BY50FW BY75SW Spare battery pack BXB50F BXB75S Attachment fittings BXP50F — Rack mounting brackets BYP50F—
Power cable (approx. 1.8m) 287 45 330 2.5 Serial communication cable (approx. 2.2m) USB communication cable (approx. 2m) 322 298 Power cable (approx. 1.8m) Serial communication cable (approx. 2.2m) USB communication cable (approx. 2m) BY75SW (unit : mm / Tolerance : ±1mm) (unit : mm / Tolerance : ±1mm) C. Dimensional outline drawing
D. Circuit block diagram This UPS outputs power input fr om commercial power as it is and charges the batter y at the same time. If a power failure or voltage variation occurs, the UPS automatically switches to operation using the battery and continues power output. At this time, the beeper sounds intermittentl y. When the power is recovered, normal operation using commercial power is automatically recovered. (The beeper stops.) You do not have to perform any operation. Input Overcurrent Protection Power Supply Output Receptacle Commercial Power Mode Battery Mode Inverter circuit Charging circuit DC-DC converterBattery
No part or whole of this manual may be reproduced without permission. The contents of this manual are subject to change without notice. OMRON SOCIAL SOLUTIONS CO.,LTD. K1L-D-06025J 614-07428-11