Gen. 7 V4 HD LED Array Product Data Sheet DS400
V Series™ HD LED array product, an ultra-high lumen density COB product line, is designed for high intensity spotlights used in commercial and retail settings. V Series HD arrays offer industry leading color over angle uniformity, and replace ceramic metal halide lamps by providing equal or greater center beam candle power at lower power and at greater lifetimes. Their tight beam control and exceptional quality of light is well suited for demanding directional spot applications. The V4 HD LED array is available in a variety of CCT and CRI combinations providing substantial design flexibility and energy efficiencies. Lighting system designs incorporating these LED arrays deliver increased system level efficacy and longer service life. Typical applications include, but are not limited to, commercial and residential down lights, accent, spot and track lights. Bridgelux Décor Series™ is our state of the art color line designed specifically for premium applications, producing unmatched LED light quality with brilliant color-rendering options and offer pleasing and inspiring lighting palettes. Bridgelux Décor Series color points are available on Vero® SE Series, Vero® Series, V Series™ and V Series™ HD. Décor Series Class A is based on human response testing, providing color points with a combined GAI and CRI metric. Décor Series™ Ultra products provide a high CRI of 97 and a minimum R9 value of 91, which emphasizes the reds and color tones to which the human eye is most receptive - perfect for the most luxurious retail shops and world renowned museums. Décor Series Ultra is designed as a replacement for halogen. Décor Series™ Showcase is the optimal solution for replacing ceramic metal halide lamps, incorporating the same pure white light with enhanced spectrum coverage and higher efficacy. V Series HD
Features
- Efficacy of 120 lm/W typical
- Compact high flux density light source
- Uniform high quality illumination
- Minimum 80, 90 and 95 CRI options
- Streamlined thermal path
- ENERGY STAR® / ANSI compliant color binning structure with 3 SDCM options
- More energy efficient than incandescent, halogen and fluorescent lamps
- Low voltage DC operation
- Instant light with unlimited dimming
- V f bin code backside marking Benefits
- Enhanced optical control
- Clean white light without pixelation
- High quality true color reproduction
- Significantly reduced thermal resistance and increased operating temperatures
- Uniform consistent white light
- Lower operating costs
- Easy to use with daylight and motion detectors to enable increased energy savings
- Reduced maintenance costs
- Environmentally friendly, no disposal issue
The part number designation for Bridgelux V Series HD LED arrays is explained as follows: 1 2 3 4 5 6 7 8 9 10 11 – 12 – 13 14 Product Family CCT Bin Options 3 = 3 SDCM CRI E = 80 CRI min. G = 90 CRI min. H = 97 CRI typ. A = Class A Array Configuration 27 = 2,700K 30 = 3,000K 35 = 3,500K 40 = 4,000K BXRH – 30 E 060 0 – A – 7 3 Color Targeting Designator 0 = Cold Targeted 1 = Hot Targeted C = Décor Series Showcase Target Gen. 7Nominal CCT Flux Indicator 060x = 600 lm Bridgelux arrays are fully engineered devices that provide consistent thermal and optical performance on an engineered mechanical platform. The V Series HD arrays are the most compact chip-on-board devices across all of Bridgelux’s LED Array products. The arrays incorporate several features to simplify design integration and assembly. Please visit www.bridgelux.com for more information on the V Series HD family of products. Fully engineered substrate for consistent thermal, mechanical and optical properties Yellow phosphor Light Emitting Surface (LES) Note: Part number and lot codes are scribed on back of array Polarity symbols White ring around LES Case Temperature (Tc) Measurement Point Designed to comply with global safety standards for creepage and clearance distances Solder Pads
The following product configurations are available: Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 Tc = 25ºC (lm) Minimum Pulsed Flux6,7 Tc = 25ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRH-27E0600-A-73 2700 80 175 727 625 36.4 6.4 114 BXRH-27G0600-A-73 2700 90 175 604 520 36.4 6.4 95 BXRH-27H0600-A-73 2700 97 175 536 461 36.4 6.4 84 BXRH-30E0600-A-73 3000 80 175 765 658 36.4 6.4 120 BXRH-30G0600-A-73 3000 90 175 643 553 36.4 6.4 101 BXRH-30G060C-A-73 3000 90 175 589 507 36.4 6.4 92 BXRH-30H0600-A-73 3000 97 175 566 487 36.4 6.4 89 BXRH-35A0601-A-738,9 3500 93 175 643 553 36.4 6.4 101 BXRH-35G0600-A-73 3500 90 175 658 566 36.4 6.4 103 BXRH-40E0600-A-73 4000 80 175 796 684 36.4 6.4 125 BXRH-40G0600-A-73 4000 90 175 673 579 36.4 6.4 106 BXRH-50E0600-A-73 5000 80 175 796 685 36.4 6.4 125 BXRH-50G0600-A-73 5000 90 175 688 592 36.4 6.4 108 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. 2. CRI values are typical for Decor Series Ultra and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI products is 91. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test. 8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line.
Table 2: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85ºC (lm) Minimum DC Flux6 Tc = 85ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRH-27E0600-A-73 2700 80 175 640 550 35.4 6.2 103 BXRH-27G0600-A-73 2700 90 175 532 457 35.4 6.2 86 BXRH-27H0600-A-73 2700 97 175 471 405 35.4 6.2 76 BXRH-30E0600-A-73 3000 80 175 673 579 35.4 6.2 109 BXRH-30G0600-A-73 3000 90 175 565 486 35.4 6.2 91 BXRH-30G060C-A-73 3000 90 175 518 446 35.4 6.2 84 BXRH-30H0600-A-73 3000 97 175 498 428 35.4 6.2 80 BXRH-35A0601-A-737,8 3500 93 175 565 486 35.4 6.2 91 BXRH-35G0600-A-73 3500 90 175 579 498 35.4 6.2 93 BXRH-40E0600-A-73 4000 80 175 700 602 35.4 6.2 113 BXRH-40G0600-A-73 4000 90 175 592 509 35.4 6.2 96 BXRH-50E0600-A-73 5000 80 175 701 603 35.4 6.2 113 BXRH-50G0600-A-73 5000 90 175 606 521 35.4 6.2 98 Notes for Table 2: 1. Nominal CCT as defined by ANSI C78.377-2011. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI products is 91. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance.
European Product Registry for Energy Labeling The European Product Registry for Energy Labeling (EPREL) is defined in the EU Regulation 2017/1369 to provide import- ant energy efficiency information to consumers. Together with Energy Labeling Regulation ELR (EU) 2019/2015 which was amended by regulation (EU) 2021/340 for energy labelling of light sources, manufacturers are required to declare an ener- gy class based on key technical specifications from each of their product and register it in an open data base managed by EPREL It is now a legal requirement for a vendor of light sources to upload information about their products into the EPREL database before placing these products on the market in the EU. Table 3 below provides a list of part numbers that are in compliance with ELR and are currently listed in the EPREL data- base. At Bridgelux, we are fully committed to supplying products that are compliant with pertinent laws, rules, and obligation imposed by relevant government bodies including the European Energy Labeling regulation. Customers can use these products with full confidence for any projects that fall under the ELR. Table 3: Part numbers registered in European Product Registry for Energy Labeling PART NUMBER1 CCT (K) CRI Current2 (mA) Vf (V) Useful flux3 (Φuse) at 85C (lm) Pow- er (W) Efficacy (lm/W) Energy efficiency class4 Regis- tration No URL to Product Information Sheet in EPREL Database Notes for Table 3: 1. All device listed here must be disposed as e-waste upon its end of life according to local country guideline in each country. 2. For information on performance values at alternative drive conditions. please refer to the Product Selection Guide, Absolute Maximum Rating Table and Performance Curves in this data sheet. 3. For a definition of useful luminous flux (ΦΦuse), please see the ELR regulations at https:/ /tinyurl.com/4b6zvt4m. 4. EPREL requires an arrow symbol containing the letter of the energy efficiency class to be displayed. on technical promotional material. Refer to this energy efficiency class column for specific energy efficiency class on each part number.
Performance at Commonly Used Drive Currents V Series HD LED arrays are tested to the specifications shown using the nominal drive currents in Table 1. V Series HD LED arrays may also be driven at other drive currents dependent on specific application design requirements. The performance at any drive current can be derived from the current vs. voltage characteristics shown in Figure 1 and the flux vs. current characteristics shown in Figure 2. The performance at commonly used drive currents is summarized in Table 4. Table 4: Product Performance at Commonly Used Drive Currents Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRH-27E0600-A-73 80 85 34.1 2.9 380 334 131 130 35.3 4.6 559 492 122 175 36.4 6.4 727 640 114 220 37.3 8.2 883 777 107 240 37.8 9.1 949 835 105 BXRH-27G0600-A-73 90 85 34.1 2.9 316 278 109 130 35.3 4.6 465 409 101 175 36.4 6.4 604 532 95 220 37.3 8.2 734 646 89 240 37.8 9.1 789 694 87 BXRH-27H0600-A-73 97 (typical) 85 34.1 2.9 280 246 97 130 35.3 4.6 412 363 90 175 36.4 6.4 536 471 84 220 37.3 8.2 650 572 79 240 37.8 9.1 699 615 77 BXRH-30E0600-A-73 80 85 34.1 2.9 400 352 138 130 35.3 4.6 589 518 128 175 36.4 6.4 765 673 120 220 37.3 8.2 929 818 113 240 37.8 9.1 999 879 110 BXRH-30G0600-A-73 90 85 34.1 2.9 336 296 116 130 35.3 4.6 495 435 108 175 36.4 6.4 643 565 101 220 37.3 8.2 781 687 95 240 37.8 9.1 839 738 93 BXRH-30G060C-A-73 90 85 34.1 2.9 308 271 106 130 35.3 4.6 453 399 99 175 36.4 6.4 589 518 93 220 37.3 8.2 716 630 87 240 37.8 9.1 769 677 85 BXRH-30H0600-A-73 97 (typical) 85 34.1 2.9 296 260 102 130 35.3 4.6 436 384 95 175 36.4 6.4 566 498 89 220 37.3 8.2 688 605 84 240 37.8 9.1 739 650 82 BXRH-35A0601-A-73 93 (typical) 85 34.1 2.9 336 296 116 130 35.3 4.6 495 435 108 175 36.4 6.4 643 565 101 220 37.3 8.2 781 687 95 240 37.8 9.1 839 738 93 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRH-35G0600-A-73 90 85 34.1 2.9 344 303 119 130 35.3 4.6 506 446 110 175 36.4 6.4 658 579 103 220 37.3 8.2 799 703 97 240 37.8 9.1 859 756 95 BXRH-40E0600-A-73 80 85 34.1 2.9 416 366 144 130 35.3 4.6 612 539 134 175 36.4 6.4 796 700 125 220 37.3 8.2 966 850 118 240 37.8 9.1 1039 914 115 BXRH-40G0600-A-73 90 85 34.1 2.9 352 310 121 130 35.3 4.6 518 456 113 175 36.4 6.4 673 592 106 220 37.3 8.2 818 720 100 240 37.8 9.1 879 774 97 BXRH-50E0600-A-73 80 85 34.1 2.9 416 366 144 130 35.3 4.6 613 539 134 175 36.4 6.4 796 701 125 220 37.3 8.2 967 852 118 240 37.8 9.1 1040 915 115 BXRH-50G0600-A-73 90 85 34.1 2.9 360 317 124 130 35.3 4.6 530 466 115 175 36.4 6.4 688 606 108 220 37.3 8.2 836 736 102 240 37.8 9.1 899 791 99 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
Electrical Characteristics
Table 5: Electrical Characteristics Part Number Drive Current (mA) Forward Voltage Pulsed, Tc = 25ºC (V) 1, 2, 3, 8 Typical Coefficient of Forward Voltage4 ∆Vf/∆Tc (mV/ºC) Typical Thermal Resistance Junction to Case5,6 Rj-c (ºC/W) Driver Selection Voltages7 (V) Minimum Typical Maximum Vf Min. Hot Tc = 105ºC (V) Vf Max. Cold Tc = -40ºC (V) BXRH-xxx060x-A-73 Notes for Table 5: 1. Parts are tested in pulsed conditions, Tc = 25°C. Pulse width is 10ms. 2. Voltage minimum and maximum are provided for reference only and are not a guarantee of performance. 3. Bridgelux maintains a tester tolerance of ± 0.10V on forward voltage measurements. 4. Typical coefficient of forward voltage tolerance is ± 0.1mV for nominal current. 5. Thermal resistance values are based from test data of a 3000K 80 CRI product. 6. Thermal resistance value was calculated using total electrical input power; optical power was not subtracted from input power. The thermal interface material used during testing is not included in the thermal resistance value. 7. Vf min hot and max cold values are provided as reference only and are not guaranteed by test. These values are provided to aid in driver design and selection over the operating range of the product. 8. This product has been designed and manufactured per IEC 62031:2018. This product has passed dielectric withstand voltage testing at 500 V. The working voltage designated for the insulation is 50V d.c. The maximum allowable voltage across the array must be determined in the end product application.
Table 6: Eye Safety Risk Group (RG) Classifications Part Number Drive Current3 (mA) CCT1,3 2700K/3000K 4000K2 BXRH-xxx060x-A-73
175 RG1 RG2
240 RG1 RG2
Notes for Table 6: 1. Eye safety classification for the use of Bridgelux V Series HD LED arrays is in accordance with specification IEC/TR 62778: Application of IEC 62471 for the assessment of blue light hazard to light sources and luminaires. 2. For products classified as RG2 at 4000K, Ethr= 1760 lx. 3. Please contact your Bridgelux sales representative for Ethr values at specific drive currents and CCTs not listed.
LED Junction Temperature (Tj) 125°C Storage Temperature -40°C to +105°C Operating Case Temperature1 (Tc) 105°C Soldering Temperature2 300°C or lower for a maximum of 6 seconds Maximum Drive Current3 240mA Maximum Peak Pulsed Drive Current4 340mA Maximum Reverse Voltage5 -60V Notes for Table 7: 1. For IEC 62717 requirement, please consult your Bridgelux sales representative. 2. Refer to Bridgelux Application Note AN101: Handling and Assembly of Bridgelux V Series LED Arrays. 3. Arrays may be driven at higher currents however lumen maintenance may be reduced, and product warranty will be void. 4. Bridgelux recommends a maximum duty cycle of 10% and pulse width of 20 ms when operating LED Arrays at maximum peak pulsed current specified. Maximum peak pulsed currents indicate values where LED Arrays can be driven without catastrophic failures. 5. Light emitting diodes are not designed to be driven in reverse voltage and will not produce light under this condition. Maximum rating provided for reference only. Table 7: Maximum Ratings
Figure 14: Drawing for V4 HD LED Array Notes for Figure 14: 1. Drawings are not to scale. 2. Drawing dimensions are in millimeters. 3. Unless otherwise specified, tolerances are ±0.1mm. 4. Solder pad labeled “+” denotes positive contact. 5. Refer to Application Notes AN101 for product handling, mounting and heat sink recommendations. 6. The optical center of the LED Array is nominally defined by the mechanical center of the array to a tolerance of ± 0.2mm. 7. Bridgelux maintains a flatness of 0.10mm across the mounting surface of the array.
Bin Code 2700K 3000K 3500K1 4000K ANSI Bin (for reference only) (2580K - 2870K) (2870K - 3220K) (3220K - 3710K) (3710K - 4260K) 73 (3 SDCM) (2651K - 2794K) (2968K - 3136K) (3369K - 3586K) (3851K - 4130K) Center Point (x,y) (0.4578, 0.4101) (0.4338, 0.403) Table 8: Warm and Neutral White xy Bin Coordinates and Associated Typical CCT Notes for Table 8-9: 1. Color Binning information excludes Décor Series Class A products. Please contact your Bridgelux Sales Representative for more information. 2. Center Point for Decor Series Showcase. 3. Bridgelux maintains a tolerance of +/- 0.007 on x and y color coordinates in the CIE 1931 color Space. Figure 15: Warm and Neutral White Test Bins in xy Color Space Note: Pulsed Test Conditions, Tc = 25°C 0.34 0.36 0.38 0.4 0.42 0.44 Y X
3 SDCM
Poly. (Black Body Curve) 3500K 4000K 3000K 2700K Note: Pulsed Test Conditions, Tc = 85°C Figure 16: Cool White Test Bins in xy Color Space 0.3 0.31 0.32 0.33 0.34 0.35 0.36 0.37 0.38 0.39 Y X
4 SDCM
Bin Code 5000K 5700K 6500K ANSI Bin (for reference only) (4745K - 5311K) (5312K - 6022K) (6022K - 7042K) 84 (4 SDCM) (4801K - 5282K) (5395K- 5970K) (6200K - 6910K) 83 (3 SDCM) (4835K - 5215K) (5460K- 5891K) (6279K -6811K) Table 9: Cool White xy Bin Coordinates and Associated Typical CCT (product is hot targeted to Tc = 85°C9
Figure 17: V4 HD Packaging Tube Notes for Figure 17: 1. Each tube holds 40 V4 HD COB arrays. 2. One tube is sealed in an anti-static bag. Four bags are placed in a shipping box. Depending on quantities ordered, a bigger shipping box, containing four boxes may be used to ship products. 3. Each bag and box is to be labeled as shown above. shipping box are 58.7 x 13.3 x 7.9 cm BXRH-30E0600-A-73
Figure 18: V Series HD Product Labeling Bridgelux COB arrays have laser markings on the back side of the substrate to help with product identification. In addition to the product identification markings, Bridgelux COB arrays also contain markings for internal Bridgelux manufacturing use only. The image below shows which markings are for customer use and which ones are for Bridgelux internal use only. The Bridgelux internal manufacturing markings are subject to change without notice, however these will not impact the form, function or performance of the COB array. Customer Use- 2D Barcode Scannable barcode provides product part number and other Bridgelux internal production information. Customer Use- Product part number 30E0600A 73 Internal Bin Code
Bridgelux has developed a comprehensive set of application notes and design resources to assist customers in successfully designing with the V Series HD product family of LED array products. For all available application notes visit www.bridgelux.com. Optical Source Models Optical source models and ray set files are available for all Bridgelux products. For a list of available formats, visit www.bridgelux.com. MINOR PRODUCT CHANGE POLICY The rigorous qualification testing on products offered by Bridgelux provides performance assurance. Slight cosmetic changes that do not affect form, fit, or function may occur as Bridgelux continues product optimization. CAUTION: CHEMICAL EXPOSURE HAZARD Exposure to some chemicals commonly used in luminaire manufacturing and assembly can cause damage to the LED array. Please consult Bridgelux CAUTION: RISK OF BURN Do not touch the V Series HD LED array during operation. Allow the array to cool for a sufficient period of time before handling. The V Series HD LED array may reach elevated temperatures such that could burn skin when touched. 3D CAD Models Three dimensional CAD models depicting the product outline of all Bridgelux V Series HD LED arrays are available in both IGS and STEP formats. Please contact your Bridgelux sales representative for assistance. LM80 LM80 testing has been completed and the LM80 report is now available. Please contact your Bridgelux sales rep- resentative for LM-80 report. STANDARD TEST CONDITIONS Unless otherwise stated, array testing is performed at the nominal drive current. CAUTION CONTACT WITH LIGHT EMITTING SURFACE (LES) Avoid any contact with the LES. Do not touch the LES of the LED array or apply stress to the LES (yellow phosphor resin area). Contact may cause damage to the LED array. Optics and reflectors must not be mounted in contact with the LES (yellow phosphor resin area).
About Bridgelux: Bridging Light and Life™ © 2021 Bridgelux, Inc. All rights reserved 2018. Product specifications are subject to change without notice. Bridgelux, the Bridgelux stylized logo design and Vero are registered trademarks, V Series and Decor Series are trademarks of Bridgelux, Inc. All other trademarks are the property of their respective owners. Bridgelux V4 HD Array Series Product Data Sheet DS400 Rev. G (11/2022)
46410 Fremont Boulevard
Fremont, CA 94538 U.S.A. Tel (925) 583-8400 www.bridgelux.com At Bridgelux, we help companies, industries and people experience the power and possibility of light. Since 2002, we’ve designed LED solutions that are high performing, energy efficient, cost effective and easy to integrate. Our focus is on light’s impact on human behavior, delivering products that create better environments, experiences and returns—both experiential and financial. And our patented technology drives new platforms for commercial and industrial luminaires. For more information about the company, please visit bridgelux.com twitter.com/Bridgelux facebook.com/Bridgelux youtube.com/user/Bridgelux linkedin.com/company/bridgelux-inc-_2 WeChat ID: BridgeluxInChina