DS401 BRIDGELUX | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 24
Technical content
Datasheet sections
Gen. 7 V6 HD LED Array Product Data Sheet DS401
V Series™ HD LED array product, an ultra-high lumen density COB product line, is designed for high intensity spotlights used in commercial and retail settings. V Series HD arrays offer industry leading color over angle uniformity, and replace ceramic metal halide lamps by providing equal or greater center beam candle power at lower power and at greater lifetimes. Their tight beam control and exceptional quality of light is well suited for demanding directional spot applications. The V6 HD LED array is available in a variety of CCT and CRI combinations providing substantial design flexibility and energy efficiencies. Lighting system designs incorporating these LED arrays deliver increased system level efficacy and longer service life. Typical applications include, but are not limited to, commercial and residential down lights, accent, spot and track lights. Bridgelux Décor Series™ is our state of the art color line designed specifically for premium applications, producing unmatched LED light quality with brilliant color-rendering options and offer pleasing and inspiring lighting palettes. Bridgelux Décor Series color points are available on Vero® SE Series, Vero® Series, V Series™ and V Series™ HD. Décor Series Class A is based on human response testing, providing color points with a combined GAI and CRI metric. Décor Series™ Ultra products provide a high CRI of 97 and a minimum R9 value of 91, which emphasizes the reds and color tones to which the human eye is most receptive - perfect for the most luxurious retail shops and world renowned museums. Décor Series Ultra is designed as a replacement for halogen. Décor Series™ Showcase is the optimal solution for replacing ceramic metal halide lamps, incorporating the same pure white light with enhanced spectrum coverage and higher efficacy. V Series HD
Features
- Efficacy of 125 lm/W typical, 3000K 80 CRI
- Compact high flux density light source
- Uniform high quality illumination
- Minimum 80, 90 and 95 CRI options
- Streamlined thermal path
- ENERGY STAR® / ANSI compliant color binning structure with 3 SDCM options
- More energy efficient than incandescent, halogen and fluorescent lamps
- Low voltage DC operation
- Instant light with unlimited dimming
- V f bin code backside marking Benefits
- Enhanced optical control
- Clean white light without pixelation
- High quality true color reproduction
- Significantly reduced thermal resistance and increased operating temperatures
- Uniform consistent white light
- Lower operating costs
- Easy to use with daylight and motion detectors to enable increased energy savings
- Reduced maintenance costs
- Environmentally friendly, no disposal issue
The part number designation for Bridgelux V Series HD LED arrays is explained as follows: 1 2 3 4 5 6 7 8 9 10 11 – 12 – 13 14 Product Family CCT Bin Options 3 = 3 SDCM CRI E = 80 CRI min. G = 90 CRI min. H = 97 CRI typ. A = Class A Array Configuration 27 = 2,700K 30 = 3,000K 35 = 3,500K 40 = 4,000K BXRH – 30 E 100 0 – B – 7 3 Color Targeting Designator 0 = Cold Targeted 1 = Hot Targeted C = Décor Series Showcase Target Gen. 7Nominal CCT Flux Indicator 100x = 1000 lm Bridgelux arrays are fully engineered devices that provide consistent thermal and optical performance on an engineered mechanical platform. The V Series HD arrays are the most compact chip-on-board devices across all of Bridgelux’s LED array products. The arrays incorporate several features to simplify design integration and assembly. Please visit www.bridgelux.com for more information on the V Series HD family of products. Fully engineered substrate for consistent thermal, mechanical and optical properties Yellow phosphor Light Emitting Surface (LES) Note: Part number and lot codes are scribed on back of array Polarity symbols Solder Pads White ring around LES Case Temperature (Tc) Measurement Point Designed to comply with global safety standards for creepage and clearance distances
The following product configurations are available: Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 Tc = 25ºC (lm) Minimum Pulsed Flux6,7 Tc = 25ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRH-27E1000-B-73 2700 80 350 1508 1297 36.4 12.7 118 BXRH-27E1000-G-73 2700 80 700 1508 1297 18.2 12.7 118 BXRH-27G1000-B-73 2700 90 350 1254 1078 36.4 12.7 98 BXRH-27G1000-G-73 2700 90 700 1254 1078 18.2 12.7 98 BXRH-27G10H0-B-73 2700 90 350 1385 1191 36.4 12.7 109 BXRH-27G10H0-G-73 2700 90 700 1385 1191 18.2 12.7 109 BXRH-27H1000-B-73 2700 97 350 1111 955 36.4 12.7 87 BXRH-27H1000-G-73 2700 97 700 1111 955 18.2 12.7 87 BXRH-30E1000-B-73 3000 80 350 1587 1365 36.4 12.7 125 BXRH-30E1000-G-73 3000 80 700 1587 1365 18.2 12.7 125 BXRH-30G1000-B-73 3000 90 350 1333 1146 36.4 12.7 105 BXRH-30G1000-G-73 3000 90 700 1333 1146 18.2 12.7 105 BXRH-30G10H0-B-73 3000 90 350 1455 1251 36.4 12.7 105 BXRH-30G10H0-G-73 3000 90 700 1455 1251 18.2 12.7 105 BXRH-30G100C-B-73 3000 90 350 1222 1051 36.4 12.7 96 BXRH-30G100C-G-73 3000 90 700 1222 1051 18.2 12.7 96 BXRH-30H1000-B-73 3000 97 350 1174 1010 36.4 12.7 92 BXRH-30H1000-G-73 3000 97 700 1174 1010 18.2 12.7 92 BXRH-35A1001-B-738,9 3500 93 350 1333 1146 36.4 12.7 105 BXRH-35A1001-G-738,9 3500 93 700 1333 1146 18.2 12.7 105 BXRH-35E1000-B-73 3500 80 350 1635 1406 36.4 12.7 128 BXRH-35E1000-G-73 3500 80 700 1635 1406 18.2 12.7 128 BXRH-35G1000-B-73 3500 90 350 1365 1174 36.4 12.7 107 BXRH-35G1000-G-73 3500 90 700 1365 1174 18.2 12.7 107 BXRH-35H1000-B-73 3500 97 350 1339 1151 36.4 12.7 105 BXRH-35H1000-G-73 3500 97 700 1339 1151 18.2 12.7 105 BXRH-40E1000-B-73 4000 80 350 1650 1419 36.4 12.7 130 BXRH-40E1000-G-73 4000 80 700 1650 1419 18.2 12.7 130 BXRH-40G1000-B-73 4000 90 350 1397 1201 36.4 12.7 110 BXRH-40G1000-G-73 4000 90 700 1397 1201 18.2 12.7 110 BXRH-40H1000-B-73 4000 97 350 1374 1182 36.4 12.7 108 BXRH-40H1000-G-73 4000 97 700 1374 1182 18.2 12.7 108 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. 2. CRI values are typical for Decor Series Ultra and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI products is 91. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test. 8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance.
Table 2: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85ºC (lm) Minimum DC Flux6 Tc = 85ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRH-27E1000-B-73 2700 80 350 1327 1141 35.4 12.4 107 BXRH-27E1000-G-73 2700 80 700 1327 1141 17.7 12.4 107 BXRH-27G1000-B-73 2700 90 350 1103 949 35.4 12.4 89 BXRH-27G1000-G-73 2700 90 700 1103 949 17.7 12.4 89 BXRH-27G10H0-B-7x 2700 90 350 1219 1048 35.4 12.4 98 BXRH-27G10H0-G-7x 2700 90 700 1219 1048 17.7 12.4 98 BXRH-27H1000-B-73 2700 97 350 978 841 35.4 12.4 79 BXRH-27H1000-G-73 2700 97 700 978 841 17.7 12.4 79 BXRH-30E1000-B-73 3000 80 350 1397 1201 35.4 12.4 113 BXRH-30E1000-G-73 3000 80 700 1397 1201 17.7 12.4 113 BXRH-30G1000-B-73 3000 90 350 1173 1009 35.4 12.4 95 BXRH-30G1000-G-73 3000 90 700 1173 1009 17.7 12.4 95 BXRH-30G10H0-B-73 3000 90 350 1280 1101 35.4 12.4 103 BXRH-30G10H0-G-73 3000 90 700 1280 1101 17.7 12.4 103 BXRH-30G100C-B-73 3000 90 350 1075 925 35.4 12.4 87 BXRH-30G100C-G-73 3000 90 700 1075 925 17.7 12.4 87 BXRH-30H1000-B-73 3000 97 350 1033 889 35.4 12.4 83 BXRH-30H1000-G-73 3000 97 700 1033 889 17.7 12.4 83 BXRH-35A1001-B-738,9 3500 93 350 1173 1009 35.4 12.4 95 BXRH-35A1001-G-738,9 3500 93 700 1173 1009 17.7 12.4 95 BXRH-35E1000-B-73 3500 80 350 1438 1237 35.4 12.4 116 BXRH-35E1000-G-73 3500 80 700 1438 1237 17.7 12.4 116 BXRH-35G1000-B-73 3500 90 350 1201 1033 35.4 12.4 97 BXRH-35G1000-G-73 3500 90 700 1201 1033 17.7 12.4 97 BXRH-35H1000-B-73 3500 97 350 1178 1013 35.4 12.4 95 BXRH-35H1000-G-73 3500 97 700 1178 1013 17.7 12.4 95 BXRH-40E1000-B-73 4000 80 350 1452 1249 35.4 12.4 117 BXRH-40E1000-G-73 4000 80 700 1452 1249 17.7 12.4 117 BXRH-40G1000-B-73 4000 90 350 1229 1057 35.4 12.4 99 BXRH-40G1000-G-73 4000 90 700 1229 1057 17.7 12.4 99 BXRH-40H1000-B-73 4000 97 350 1209 1040 35.4 12.4 98 BXRH-40H1000-G-73 4000 97 700 1209 1040 17.7 12.4 98 Notes for Table 2: 1. Nominal CCT as defined by ANSI C78.377-2011. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI prod- ucts is 91. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance.
European Product Registry for Energy Labeling The European Product Registry for Energy Labeling (EPREL) is defined in the EU Regulation 2017/1369 to provide import- ant energy efficiency information to consumers. Together with Energy Labeling Regulation ELR (EU) 2019/2015 which was amended by regulation (EU) 2021/340 for energy labelling of light sources, manufacturers are required to declare an ener- gy class based on key technical specifications from each of their product and register it in an open data base managed by EPREL It is now a legal requirement for a vendor of light sources to upload information about their products into the EPREL database before placing these products on the market in the EU. Table 3 below provides a list of part numbers that are in compliance with ELR and are currently listed in the EPREL data- base. At Bridgelux, we are fully committed to supplying products that are compliant with pertinent laws, rules, and obligation imposed by relevant government bodies including the European Energy Labeling regulation. Customers can use these Table 3: Part numbers registered in European Product Registry for Energy Labeling PART NUMBER1 CCT (K) CRI Current2 (mA) Vf (V) Useful flux3 (Φuse) at 85C (lm) Pow- er (W) Efficacy (lm/W) Energy efficiency class4 Regis- tration No URL to Product Information Sheet in EPREL Database Notes for Table 3: 1. All device listed here must be disposed as e-waste upon its end of life according to local country guideline in each country. 2. For information on performance values at alternative drive conditions. please refer to the Product Selection Guide, Absolute Maximum Rating Table and Performance Curves in this data sheet. 3. For a definition of useful luminous flux (ΦΦuse), please see the ELR regulations at https:/ /tinyurl.com/4b6zvt4m. 4. EPREL requires an arrow symbol containing the letter of the energy efficiency class to be displayed. on technical promotional material. Refer to this energy efficiency class column for specific energy efficiency class on each part number.
Performance at Commonly Used Drive Currents V Series HD LED arrays are tested to the specifications shown using the nominal drive currents in Table 1. V Series HD LED arrays may also be driven at other drive currents dependent on specific application design requirements. The performance at any drive current can be derived from the current vs. voltage characteristics shown in Figure 1 & 2 and the flux vs. current characteristics shown in Figure 3 & 4. The performance at commonly used drive currents is summarized in Table 4. Table 4: Product Performance at Commonly Used Drive Currents Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRH-27E1000-B-73 80 175 34.2 6.0 813 715 136 250 35.2 8.8 1123 988 128 350 36.4 12.7 1508 1327 118 440 37.3 16.4 1833 1613 112 480 37.7 18.1 1970 1734 109 BXRH-27E1000-G-73 80 350 16.9 5.9 813 715 137 500 17.4 8.7 1123 988 129 700 18.2 12.7 1508 1327 118 880 18.5 16.3 1833 1613 113 960 18.7 17.9 1970 1734 110 BXRH-27G1000-B-73 90 175 34.2 6.0 676 595 113 250 35.2 8.8 934 822 106 350 36.4 12.7 1254 1103 98 440 37.3 16.4 1524 1341 93 480 37.7 18.1 1638 1442 90 BXRH-27G1000-G-73 90 350 16.9 5.9 676 595 114 500 17.4 8.7 934 822 107 700 18.2 12.7 1254 1103 98 880 18.5 16.3 1524 1341 94 960 18.7 17.9 1638 1442 91 BXRH-27G10H0-B-73 90 175 34.2 6.0 747 672 125 250 35.2 8.8 1030 927 117 350 36.4 12.7 1385 1246 109 440 37.3 16.4 1684 1516 103 480 37.7 18.1 1810 1629 100 BXRH-27G10H0-G-73 90 350 16.9 5.9 747 672 126 500 17.4 8.7 1030 927 118 700 18.2 12.7 1385 1246 109 880 18.5 16.3 1684 1516 103 960 18.7 18.0 1810 1629 101 BXRH-27H1000-B-73 97 (typcal) 175 34.2 6.0 599 527 100 250 35.2 8.8 827 728 94 350 36.4 12.7 1111 978 87 440 37.3 16.4 1351 1189 82 480 37.7 18.1 1452 1277 80 BXRH-27H1000-G-73 97 (typcal) 350 16.9 5.9 599 527 101 500 17.4 8.7 827 728 95 700 18.2 12.7 1111 978 87 880 18.5 16.3 1351 1189 83 960 18.7 17.9 1452 1277 81 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRH-30E1000-B-73 80 175 34.2 6.0 855 753 143 250 35.2 8.8 1182 1040 134 350 36.4 12.7 1587 1397 125 440 37.3 16.4 1930 1698 117 480 37.7 18.1 2074 1825 114 BXRH-30E1000-G-73 80 350 16.9 5.9 855 753 144 500 17.4 8.7 1182 1040 136 700 18.2 12.7 1587 1397 125 880 18.5 16.3 1930 1698 119 960 18.7 17.9 2074 1825 116 BXRH-30G1000-B-73 90 175 34.2 6.0 718 632 120 250 35.2 8.8 993 874 113 350 36.4 12.7 1333 1173 105 440 37.3 16.4 1621 1426 99 480 37.7 18.1 1742 1533 96 BXRH-30G1000-G-73 90 350 16.9 5.9 718 632 121 500 17.4 8.7 993 874 114 700 18.2 12.7 1333 1173 105 880 18.5 16.3 1621 1426 100 960 18.7 17.9 1742 1533 97 BXRH-30G10H0-B-73 90 175 34.2 6.0 784 706 131 250 35.2 8.8 1082 974 123 350 36.4 12.7 1455 1309 114 440 37.3 16.4 1769 1592 108 480 37.7 18.1 1901 1711 105 BXRH-30G10H0-G-73 90 350 16.9 5.9 784 706 133 500 17.4 8.7 1082 974 124 700 18.2 12.7 1455 1309 114 880 18.5 16.3 1769 1592 109 960 18.7 18.0 1901 1711 106 BXRH-30G100C-B-73 90 175 34.2 6.0 659 580 110 250 35.2 8.8 910 801 103 350 36.4 12.7 1222 1075 96 440 37.3 16.4 1486 1308 90 480 37.7 18.1 1597 1405 88 BXRH-30G100C-G-73 90 350 16.9 5.9 659 580 111 500 17.4 8.7 910 801 105 700 18.2 12.7 1222 1075 96 880 18.5 16.3 1486 1308 91 960 18.7 17.9 1597 1405 89 BXRH-30H1000-B-73 97 (typcal) 175 34.2 6.0 633 557 106 250 35.2 8.8 874 770 99 350 36.4 12.7 1174 1033 92 440 37.3 16.4 1428 1257 87 480 37.7 18.1 1535 1350 85 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRH-30H1000-G-73 97 (typcal) 350 16.9 5.9 633 557 107 500 17.4 8.7 874 770 100 700 18.2 12.7 1174 1033 92 880 18.5 16.3 1428 1257 88 960 18.7 17.9 1535 1350 86 BXRH-35A1001-B-73 93 (typcal) 175 34.2 6.0 718 632 120 250 35.2 8.8 993 874 113 350 36.4 12.7 1333 1173 105 440 37.3 16.4 1621 1426 99 480 37.7 18.1 1742 1533 96 BXRH-35A1001-G-73 93 (typcal) 350 16.9 5.9 718 632 121 500 17.4 8.7 993 874 114 700 18.2 12.7 1333 1173 105 880 18.5 16.3 1621 1426 100 960 18.7 17.9 1742 1533 97 BXRH-35E1000-B-73 80 175 34.2 6.0 881 775 147 250 35.2 8.8 1217 1071 138 350 36.4 12.7 1635 1438 128 440 37.3 16.4 1988 1749 121 480 37.7 18.1 2136 1880 118 BXRH-35E1000-G-73 80 350 17.1 6.0 881 775 147 500 17.6 8.8 1217 1071 138 700 18.2 12.7 1635 1438 128 880 18.7 16.4 1988 1749 121 960 18.9 18.1 2136 1880 118 BXRH-35G1000-B-73 90 175 34.2 5.9 736 647 123 250 35.2 8.8 1016 894 116 350 36.4 12.7 1365 1201 107 440 37.3 16.4 1659 1460 101 480 37.7 18.1 1783 1569 98 BXRH-35G1000-G-73 90 350 16.9 6.0 736 647 124 500 17.4 8.7 1016 894 117 700 18.2 12.7 1365 1201 107 880 18.5 16.3 1659 1460 102 960 18.7 17.9 1783 1569 99 BXRH-35H1000-B-73 97 (typcal) 175 34.2 6.0 722 650 121 250 35.2 8.8 996 896 113 350 36.4 12.7 1339 1205 105 440 37.3 16.4 1628 1465 99 480 37.7 18.1 1750 1575 97 BXRH-35H1000-G-73 97 (typcal) 350 16.9 5.9 722 650 122 500 17.4 8.7 996 896 114 700 18.2 12.7 1339 1205 105 880 18.5 16.3 1628 1465 100 960 18.7 18.0 1750 1575 97 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRH-40E1000-B-73 80 175 34.2 6.0 889 783 149 250 35.2 8.8 1229 1082 140 350 36.4 12.7 1650 1452 130 440 37.3 16.4 2007 1766 122 480 37.7 18.1 2157 1898 119 BXRH-40E1000-G-73 80 350 16.9 5.9 889 783 150 500 17.4 8.7 1229 1082 141 700 18.2 12.7 1650 1452 130 880 18.5 16.3 2007 1766 123 960 18.7 17.9 2157 1898 120 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
Electrical Characteristics
Table 5: Electrical Characteristics Part Number Drive Current (mA) Forward Voltage Pulsed, Tc = 25ºC (V) 1, 2, 3, 8 Typical Coefficient of Forward Voltage4 ∆Vf/∆Tc (mV/ºC) Typical Thermal Resistance Junction to Case5,6 Rj-c (ºC/W) Driver Selection Voltages7 (V) Minimum Typical Maximum Vf Min. Hot Tc = 105ºC (V) Vf Max. Cold Tc = -40ºC (V) BXRH-xxx100x-B-73 BXRH-xxx100x-G-73 Notes for Table 5: 1. Parts are tested in pulsed conditions, Tc = 25°C. Pulse width is 10ms. 2. Voltage minimum and maximum are provided for reference only and are not a guarantee of performance. 3. Bridgelux maintains a tester tolerance of ± 0.10V on forward voltage measurements. 4. Typical coefficient of forward voltage tolerance is ± 0.1mV for nominal current. 5. Thermal resistance values are based from test data of a 3000K 80 CRI product. 6. Thermal resistance value was calculated using total electrical input power; optical power was not subtracted from input power. The thermal interface material used during testing is not included in the thermal resistance value. 7. Vf min hot and max cold values are provided as reference only and are not guaranteed by test. These values are provided to aid in driver design and selection over the operating range of the product. 8. This product has been designed and manufactured per IEC 62031:2018. This product has passed dielectric withstand voltage testing at 500 V. The working voltage designated for the insulation is 50V d.c. The maximum allowable voltage across the array must be determined in the end product application.
Table 6: Eye Safety Risk Group (RG) Classifications Part Number Drive Current3 (mA) CCT1,3 2700K/3000K 4000K2 BXRH-xxx100x-B-73
350 RG1 RG2
480 RG1 RG2
700 RG1 RG2
960 RG1 RG2
Notes for Table 6: 1. Eye safety classification for the use of Bridgelux V Series HD LED arrays is in accordance with specification IEC/TR 62778: Application of IEC 62471 for the assessment of blue light hazard to light sources and luminaires. 2. For products classified as RG2 at 4000K, Ethr= 1760 lx. 3. Please contact your Bridgelux sales representative for Ethr values at specific drive currents and CCTs not listed.
LED Junction Temperature (Tj) 125°C Storage Temperature -40°C to +105°C Operating Case Temperature1 (Tc) 105°C Soldering Temperature2 300°C or lower for a maximum of 6 seconds BXRH-xxx100x-B-73 BXRH-xxx100x-G-73 Maximum Drive Current3 480mA 960mA Maximum Peak Pulsed Drive Current4 680mA 1360mA Maximum Reverse Voltage5 -60V -35V Notes for Table 7: 1. For IEC 62717 requirement, please consult your Bridgelux sales representative. 2. Refer to Bridgelux Application Note AN101: Handling and Assembly of Bridgelux V Series LED Arrays. 3. Arrays may be driven at higher currents however lumen maintenance may be reduced, and product warranty will be void. 4. Bridgelux recommends a maximum duty cycle of 10% and pulse width of 20 ms when operating LED Arrays at maximum peak pulsed current specified. Maximum peak pulsed currents indicate values where LED Arrays can be driven without catastrophic failures. 5. Light emitting diodes are not designed to be driven in reverse voltage and will not produce light under this condition. Maximum rating provided for reference only. Table 7: Maximum Ratings
Figure 16: Drawing for V6 HD LED Array Notes for Figure 16: 1. Drawings are not to scale. 2. Drawing dimensions are in millimeters. 3. Unless otherwise specified, tolerances are ±0.1mm. 4. Solder pad labeled “+” denotes positive contact. 5. Refer to Application Notes AN101 for product handling, mounting and heat sink recommendations. 6. The optical center of the LED Array is nominally defined by the mechanical center of the array to a tolerance of ± 0.2mm. 7. Bridgelux maintains a flatness of 0.10mm across the mounting surface of the array.
Bin Code 2700K 3000K1 3500K1 4000K1 ANSI Bin (for reference only) (2580K - 2870K) (2870K - 3220K) (3220K - 3710K) (3710K - 4260K) 73 (3 SDCM) (2651K - 2794K) (2968K - 3136K) (3369K - 3586K) (3851K - 4130K) Center Point (x,y) (0.4578, 0.4101) (0.4338, 0.403) Table 8: Warm and Neutral White xy Bin Coordinates and Associated Typical CCT Notes for Table 8: 1. Color Binning information excludes Décor Series Class A products. Please contact your Bridgelux Sales Representative for more information. 2. Center Point for Decor Series Showcase. 3. Bridgelux maintains a tolerance of +/- 0.007 on x and y color coordinates in the CIE 1931 color Space. Figure 17: Warm and Neutral White Test Bins in xy Color Space Note: Pulsed Test Conditions, Tc = 25°C 0.34 0.36 0.38 0.4 0.42 0.44 Y X
3 SDCM
Poly. (Black Body Curve) 3500K 4000K 3000K 2700K
Figure 18: V6 HD Packaging Tube Notes for Figure 18: 1. Each tube holds 35 V6 HD COB arrays. 2. One tube is sealed in an anti-static bag. Four bags are placed in a shipping box. Depending on quantities ordered, a bigger shipping box, containing four boxes may be used to ship products. 3. Each bag and box is to be labeled as shown above. shipping box are 58.7 x 13.3 x 7.9 cm BXRH-30E1000-B-73
Figure 19: V Series HD Product Labeling Bridgelux COB arrays have laser markings on the back side of the substrate to help with product identification. In addition to the product identification markings, Bridgelux COB arrays also contain markings for internal Bridgelux manufacturing use only. The image below shows which markings are for customer use and which ones are for Bridgelux internal use only. The Bridgelux internal manufacturing markings are subject to change without notice, however these will not impact the form, function or performance of the COB array. Customer Use- 2D Barcode Scannable barcode provides product part number and other Bridgelux internal production information. Customer Use- Product part number 30E1000B 73 Internal Bin Code
Bridgelux has developed a comprehensive set of application notes and design resources to assist customers in successfully designing with the V Series HD product family of LED array products. For all available application notes visit www.bridgelux.com. Optical Source Models Optical source models and ray set files are available for all Bridgelux products. For a list of available formats, visit www.bridgelux.com. MINOR PRODUCT CHANGE POLICY The rigorous qualification testing on products offered by Bridgelux provides performance assurance. Slight cosmetic changes that do not affect form, fit, or function may occur as Bridgelux continues product optimization. CAUTION: CHEMICAL EXPOSURE HAZARD Exposure to some chemicals commonly used in luminaire manufacturing and assembly can cause damage to the LED array. Please consult Bridgelux CAUTION: RISK OF BURN Do not touch the V Series HD LED array during operation. Allow the array to cool for a sufficient period of time before handling. The V Series HD LED array may reach elevated temperatures such that could burn skin when touched. 3D CAD Models Three dimensional CAD models depicting the product outline of all Bridgelux V Series HD LED arrays are available in both IGS and STEP formats. Please contact your Bridgelux sales representative for assistance. LM80 LM80 testing has been completed and the LM80 report is now available. Please contact your Bridgelux sales rep- resentative for LM-80 report. STANDARD TEST CONDITIONS Unless otherwise stated, array testing is performed at the nominal drive current. CAUTION CONTACT WITH LIGHT EMITTING SURFACE (LES) Avoid any contact with the LES. Do not touch the LES of the LED array or apply stress to the LES (yellow phosphor resin area). Contact may cause damage to the LED array. Optics and reflectors must not be mounted in contact with the LES (yellow phosphor resin area).
About Bridgelux: Bridging Light and Life™ © 2021 Bridgelux, Inc. All rights reserved 2020. Product specifications are subject to change without notice. Bridgelux, the Bridgelux stylized logo design and Vero are registered trademarks, V Series and Decor Series are trademarks of Bridgelux, Inc. All other trademarks are the property of their respective owners. Bridgelux V6 HD Array Series Product Data Sheet DS401 Rev. K (11/2022)
46410 Fremont Boulevard
Fremont, CA 94538 U.S.A. Tel (925) 583-8400 www.bridgelux.com At Bridgelux, we help companies, industries and people experience the power and possibility of light. Since 2002, we’ve designed LED solutions that are high performing, energy efficient, cost effective and easy to integrate. Our focus is on light’s impact on human behavior, delivering products that create better environments, experiences and returns—both experiential and financial. And our patented technology drives new platforms for commercial and industrial luminaires. For more information about the company, please visit bridgelux.com twitter.com/Bridgelux facebook.com/Bridgelux youtube.com/user/Bridgelux linkedin.com/company/bridgelux-inc-_2 WeChat ID: BridgeluxInChina