DS404 BRIDGELUX | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 28

Technical content

Datasheet sections

V Series™ HD LED array product, an ultra-high lumen density COB product line, is designed for high intensity spotlights used in commercial and retail settings. V Series HD arrays offer industry leading color over angle uniformity, and replace ceramic metal halide lamps by providing equal or greater center beam candle power at lower power and at greater lifetimes. Their tight beam control and exceptional quality of light is well suited for demanding directional spot applications. The V4 HD LED array is available in a variety of CCT and CRI combinations providing substantial design flexibility and energy efficiencies. Lighting system designs incorporating these LED arrays deliver increased system level efficacy and longer service life. Typical applications include, but are not limited to, commercial and residential down lights, accent, spot and track lights. Bridgelux Décor Series™ is our state of the art color line designed specifically for premium applications, producing unmatched LED light quality with brilliant color-rendering options and offer pleasing and inspiring lighting palettes. Bridgelux Décor Series color points are available on Vero® SE Series, Vero® Series, V Series™ and V Series™ HD. Décor Series™ Ultra products provide a high CRI of 97 and a minimum R9 value of 91, which emphasizes the reds and color tones to which the human eye is most receptive - perfect for the most luxurious retail shops and world renowned museums. Décor Series Ultra is designed as a replacement for halogen.

Features

  • Efficacy of 136 lm/W typical
  • Compact high flux density light source
  • Uniform high quality illumination
  • Minimum 80, 90 and 95 CRI options
  • Streamlined thermal path
  • ENERGY STAR® / ANSI compliant color binning structure with 3 SDCM options
  • More energy efficient than incandescent, halogen and fluorescent lamps
  • Low voltage DC operation
  • Instant light with unlimited dimming Benefits
  • Enhanced optical control
  • Clean white light without pixelation
  • High quality true color reproduction
  • Significantly reduced thermal resistance and increased operating temperatures
  • Uniform consistent white light
  • Lower operating costs
  • Easy to use with daylight and motion detectors to enable increased energy savings
  • Reduced maintenance costs
  • Environmentally friendly, no disposal issue

The arrays incorporate several features to simplify design integration and assembly. Please visit www.bridgelux.com for more information on the V Series HD family of products. Product Feature Map Bridgelux arrays are fully engineered devices that provide consistent thermal and optical performance on an engineered mechanical platform. The V Series HD arrays are the most compact chip-on-borad devices across all of Bridgelux’s LED Array products. Note: Part number and lot codes are scribed on back of array Polarity symbols Solder pads White ring around LES Case Temperature (Tc) Measurement Point Fully engineered substrate for consistent thermal, mechanical and optical properties Yellow phosphor Light Emitting Surface (LES) Product Nomenclature The part number designation for Bridgelux V Series HD LED arrays is explained as follows: 1 2 3 4 5 6 7 8 9 10 11 – 12 – 13 14 Product Family CCT Bin Options 3 = 3 SDCM CRI E = 80 CRI min. G = 90 CRI min. H = 97 CRI typ. Array Configuration 27 = 2,700K 30 = 3,000K 35 = 3,500K 40 = 4,000K BXRH – 30 E 060 0 – A – 8 3 Color Targeting Designator 0 = Cold Targeted 1 = Hot Targeted Gen. 8Nominal CCT Flux Indicator 060x = 600 lm

The following product configurations are available: Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 Tc = 25ºC (lm) Minimum Pulsed Flux6,7 Tc = 25ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRH-22E0600-A-8x 2200 80 175 651 586 36.6 6.4 102 BXRH-22E0600-B-8x 2200 80 350 651 586 18.3 6.4 102 BXRH-22G0600-A-8x 2200 90 175 560 504 36.6 6.4 87 BXRH-22G0600-B-8x 2200 90 350 560 504 18.3 6.4 87 BXRH-22H0600-A-8x 2200 97 175 473 426 36.6 6.4 74 BXRH-22H0600-B-8x 2200 97 350 473 426 18.3 6.4 74 BXRH-24G0600-A-8x 2400 90 175 600 540 36.6 6.4 94 BXRH-24G0600-B-8x 2400 90 350 600 540 18.3 6.4 94 BXRH-24H0600-A-8x 2400 97 175 507 456 36.6 6.4 79 BXRH-24H0600-B-8x 2400 97 350 507 456 18.3 6.4 79 BXRH-25E0600-A-8x 2500 80 175 781 703 36.6 6.4 122 BXRH-25E0600-B-8x 2500 80 350 781 703 18.3 6.4 122 BXRH-27E0600-A-8x 2700 80 175 817 735 36.6 6.4 128 BXRH-27E0600-B-8x 2700 80 350 817 735 18.3 6.4 128 BXRH-27G0600-A-8x 2700 90 175 674 607 36.6 6.4 105 BXRH-27G0600-B-8x 2700 90 350 674 607 18.3 6.4 105 BXRH-27H0600-A-8x 2700 97 175 597 538 36.6 6.4 93 BXRH-27H0600-B-8x 2700 97 350 597 538 18.3 6.4 93 BXRH-30E0600-A-8x 3000 80 175 868 781 36.6 6.4 136 BXRH-30E0600-B-8x 3000 80 350 868 781 18.3 6.4 136 BXRH-30G0600-A-8x 3000 90 175 705 634 36.6 6.4 110 BXRH-30G0600-B-8x 3000 90 350 705 634 18.3 6.4 110 BXRH-30H0600-A-8x 3000 97 175 638 574 36.6 6.4 100 BXRH-30H0600-B-8x 3000 97 350 638 574 18.3 6.4 100 BXRH-35E0600-A-8x 3500 80 175 888 800 36.6 6.4 139 BXRH-35E0600-B-8x 3500 80 350 888 800 18.3 6.4 139 BXRH-35G0600-A-8x 3500 90 175 730 657 36.6 6.4 114 BXRH-35G0600-B-8x 3500 90 350 730 657 18.3 6.4 114 BXRH-35H0600-A-8x 3500 97 175 656 590 36.6 6.4 102 BXRH-35H0600-B-8x 3500 97 350 656 590 18.3 6.4 102 BXRH-40E0600-A-8x 4000 80 175 894 804 36.6 6.4 140 BXRH-40E0600-B-8x 4000 80 350 894 804 18.3 6.4 140 BXRH-40G0600-A-8x 4000 90 175 745 671 36.6 6.4 116 BXRH-40G0600-B-8x 4000 90 350 745 671 18.3 6.4 116 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. 2. CRI values are typical for Decor Series Ultra CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI products is 91. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test.

Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C)(Continued) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 Tc = 25ºC (lm) Minimum Pulsed Flux6,7 Tc = 25ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRH-40H0600-A-8x 4000 97 175 674 607 36.6 6.4 105 BXRH-40H0600-B-8x 4000 97 350 674 607 18.3 6.4 105 BXRH-50E0601-A-8x 5000 80 175 904 813 36.6 6.4 141 BXRH-50E0601-B-8x 5000 80 350 904 813 18.3 6.4 141 BXRH-50G0601-A-8x 5000 90 175 781 703 36.6 6.4 122 BXRH-50G0601-B-8x 5000 90 350 781 703 18.3 6.4 122 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. 2. CRI values are typical for Decor Series Ultra. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI products is 91. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal drive current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test.

Table 2: Selection Guide, Stabilized DC Performance (Tc = 85°C) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85ºC (lm) Minimum DC Flux6 Tc = 85ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRH-22E0600-A-8x 2200 80 175 586 527 35.4 6.2 95 BXRH-22E0600-B-8x 2200 80 350 586 527 17.7 6.2 95 BXRH-22G0600-A-8x 2200 90 175 504 454 35.4 6.2 81 BXRH-22G0600-B-8x 2200 90 350 504 454 17.7 6.2 81 BXRH-22H0600-A-8x 2200 97 175 426 383 35.4 6.2 69 BXRH-22H0600-B-8x 2200 97 350 426 383 17.7 6.2 69 BXRH-24G0600-A-8x 2400 90 175 540 486 35.4 6.2 87 BXRH-24G0600-B-8x 2400 90 350 540 486 17.7 6.2 87 BXRH-24H0600-A-8x 2400 97 175 456 411 35.4 6.2 74 BXRH-24H0600-B-8x 2400 97 350 456 411 17.7 6.2 74 BXRH-25E0600-A-8x 2500 80 175 703 633 35.4 6.2 113 BXRH-25E0600-B-8x 2500 80 350 703 633 17.7 6.2 113 BXRH-27E0600-A-8x 2700 80 175 735 662 35.4 6.2 119 BXRH-27E0600-B-8x 2700 80 350 735 662 17.7 6.2 119 BXRH-27G0600-A-8x 2700 90 175 607 546 35.4 6.2 98 BXRH-27G0600-B-8x 2700 90 350 607 546 17.7 6.2 98 BXRH-27H0600-A-8x 2700 97 175 538 484 35.4 6.2 87 BXRH-27H0600-B-8x 2700 97 350 538 484 17.7 6.2 87 BXRH-30E0600-A-8x 3000 80 175 781 703 35.4 6.2 126 BXRH-30E0600-B-8x 3000 80 350 781 703 17.7 6.2 126 BXRH-30G0600-A-8x 3000 90 175 634 571 35.4 6.2 102 BXRH-30G0600-B-8x 3000 90 350 634 571 17.7 6.2 102 BXRH-30H0600-A-8x 3000 97 175 574 517 35.4 6.2 93 BXRH-30H0600-B-8x 3000 97 350 574 517 17.7 6.2 93 BXRH-35E0600-A-8x 3500 80 175 800 720 35.4 6.2 129 BXRH-35E0600-B-8x 3500 80 350 800 720 17.7 6.2 129 BXRH-35G0600-A-8x 3500 90 175 657 591 35.4 6.2 106 BXRH-35G0600-B-8x 3500 90 350 657 591 17.7 6.2 106 BXRH-35H0600-A-8x 3500 97 175 590 531 35.4 6.2 95 BXRH-35H0600-B-8x 3500 97 350 590 531 17.7 6.2 95 BXRH-40E0600-A-8x 4000 80 175 804 724 35.4 6.2 130 BXRH-40E0600-B-8x 4000 80 350 804 724 17.7 6.2 130 BXRH-40G0600-A-8x 4000 90 175 671 604 35.4 6.2 108 BXRH-40G0600-B-8x 4000 90 350 671 604 17.7 6.2 108 Notes for Table 2: 1. Nominal CCT as defined by ANSI C78.377-2011. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra . CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI products is 91. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.

Table 2: Selection Guide, Stabilized DC Performance (Tc = 85°C) (Continued) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85ºC (lm) Minimum DC Flux6 Tc = 85ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRH-40H0600-A-8x 4000 97 175 607 546 35.4 6.2 98 BXRH-40H0600-B-8x 4000 97 350 607 546 17.7 6.2 98 BXRH-50E0601-A-8x 5000 80 175 813 732 36.6 6.2 127 BXRH-50E0601-B-8x 5000 80 350 813 732 18.3 6.2 127 BXRH-50G0601-A-8x 5000 90 175 703 633 36.6 6.2 110 BXRH-50G0601-B-8x 5000 90 350 703 633 18.3 6.2 110 Notes for Table 2: 1. Nominal CCT as defined by ANSI C78.377-2011. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra . CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI products is 91. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.

European Product Registry for Energy Labeling The European Product Registry for Energy Labeling (EPREL) is defined in the EU Regulation 2017/1369 to provide important energy efficiency information to consumers. Together with Energy Labeling Regulation ELR (EU) 2019/2015 which was amend- ed by regulation (EU) 2021/340 for energy labelling of light sources, manufacturers are required to declare an energy class based on key technical specifications from each of their product and register it in an open data base managed by EPREL It is now a legal requirement for a vendor of light sources to upload information about their products into the EPREL database before placing these products on the market in the EU. Table 3 below provides a list of part numbers that are in compliance with ELR and are currently listed in the EPREL database. At Bridgelux, we are fully committed to supplying products that are compliant with pertinent laws, rules, and obligation im- posed by relevant government bodies including the European Energy Labeling regulation. Customers can use these products with full confidence for any projects that fall under the ELR. Table 3: Part numbers registered in European Product Registry for Energy Labeling PART NUMBER1 CCT (K) CRI Current2 (mA) Vf (V) Useful flux3 (Φuse) at 85C (lm) Pow- er (W) Efficacy (lm/W) Energy efficiency class4 Regis- tration No URL to Product Information Sheet in EPREL Database Notes for Table 3: 1. All device listed here must be disposed as e-waste upon its end of life according to local country guideline in each country. 2. For information on performance values at alternative drive conditions. please refer to the Product Selection Guide, Absolute Maximum Rating Table and Performance Curves in this data sheet. 3. For a definition of useful luminous flux (ΦΦuse), please see the ELR regulations at https:/ /tinyurl.com/4b6zvt4m. 4. EPREL requires an arrow symbol containing the letter of the energy efficiency class to be displayed. on technical promotional material. Refer to this energy efficiency class column for specific energy efficiency class on each part number.

Performance at Commonly Used Drive Currents V Series HD LED arrays are tested to the specifications shown using the nominal drive currents in Table 1. V Series HD LED arrays may also be driven at other drive currents dependent on specific application design requirements. The performance at any drive current can be derived from the current vs. voltage characteristics shown in Figures 1 & 2 and the flux vs. cur- rent characteristics shown in Figures 3 & 4. The performance at commonly used drive currents is summarized in Table 4. Table 4: Product Performance at Commonly Used Drive Currents Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRH-22E0600-A-8x 80 85 34.1 2.9 341 307 117 130 35.5 4.6 501 451 109 175 36.6 6.4 651 586 102 220 37.8 8.3 791 712 95 240 38.2 9.2 850 765 92 300 39.5 11.8 1014 913 86 BXRH-22E0600-B-8x 80 170 17.1 2.9 341 307 117 260 17.7 4.6 501 451 109 350 18.3 6.4 651 586 102 440 18.9 8.3 791 712 95 480 19.1 9.2 850 765 92 600 19.7 11.8 1014 913 86 BXRH-22G0600-A-8x 90 85 34.1 2.9 293 264 101 130 35.5 4.6 431 388 93 175 36.6 6.4 560 504 87 220 37.8 8.3 681 613 82 240 38.2 9.2 731 658 80 300 39.5 11.9 872 785 74 BXRH-22G0600-B-8x 90 170 17.1 2.9 293 264 101 260 17.7 4.6 431 388 94 350 18.3 6.4 560 504 87 440 18.9 8.3 681 613 82 480 19.1 9.2 731 658 80 600 19.7 11.8 872 785 74 BXRH-22H0600-A-8x 97 85 34.1 2.9 247 223 85 130 35.5 4.6 364 328 79 175 36.6 6.4 473 426 74 220 37.8 8.3 575 517 69 240 38.2 9.2 617 556 67 300 39.5 11.9 737 663 62 BXRH-22H0600-B-8x 97 170 17.1 2.9 247 223 85 260 17.7 4.6 364 328 79 350 18.3 6.4 473 426 74 440 18.9 8.3 575 517 69 480 19.1 9.2 617 556 67 600 19.7 11.8 737 663 62 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRH-24G0600-A-8x 90 85 34.1 2.9 314 282 108 130 35.5 4.6 462 416 100 175 36.6 6.4 600 540 94 220 37.8 8.3 729 656 88 240 38.2 9.2 783 705 85 300 39.5 11.9 935 841 79 BXRH-24G0600-B-8x 90 170 17.1 2.9 314 282 108 260 17.7 4.6 462 416 100 350 18.3 6.4 600 540 94 440 18.9 8.3 729 656 88 480 19.1 9.2 783 705 85 600 19.7 11.8 935 841 79 BXRH-24H0600-A-8x 97 85 34.1 2.9 265 239 91 130 35.5 4.6 390 351 85 175 36.6 6.4 507 456 79 220 37.8 8.3 616 555 74 240 38.2 9.2 662 596 72 300 39.5 11.9 790 711 67 BXRH-24H0600-B-8x 97 170 17.1 2.9 265 239 91 260 17.7 4.6 390 351 85 350 18.3 6.4 507 456 79 440 18.9 8.3 616 555 74 480 19.1 9.2 662 596 72 600 19.7 11.8 790 711 67 BXRH-25E0600-A-8x 80 85 34.1 2.9 409 368 141 130 35.5 4.6 601 541 130 175 36.6 6.4 781 703 122 220 37.8 8.3 949 854 114 240 38.2 9.2 1020 918 111 300 39.5 11.8 1217 1095 103 BXRH-25E0600-B-8x 80 170 17.1 2.9 409 368 141 260 17.7 4.6 601 541 130 350 18.3 6.4 781 703 122 440 18.9 8.3 949 854 114 480 19.1 9.2 1020 918 111 600 19.7 11.8 1217 1095 103 BXRH-27E0600-A-8x 80 85 34.1 2.9 427 385 147 130 35.5 4.6 629 566 136 175 36.6 6.4 817 735 128 220 37.8 8.3 993 893 119 240 38.2 9.2 1066 960 116 300 39.5 11.8 1273 1146 107 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRH-27E0600-B-8x 80 170 17.1 2.9 427 385 147 260 17.7 4.6 629 566 136 350 18.3 6.4 817 735 128 440 18.9 8.3 993 893 119 480 19.1 9.2 1066 960 116 600 19.7 11.8 1273 1146 107 BXRH-27G0600-A-8x 90 85 34.1 2.9 353 317 121 130 35.5 4.6 519 467 113 175 36.6 6.4 674 607 105 220 37.8 8.3 819 737 99 240 38.2 9.2 880 792 96 300 39.5 11.8 1050 945 89 BXRH-27G0600-B-8x 90 170 17.1 2.9 353 317 121 260 17.7 4.6 519 467 113 350 18.3 6.4 674 607 105 440 18.9 8.3 819 737 99 480 19.1 9.2 880 792 96 600 19.7 11.8 1050 945 89 BXRH-27H0600-A-8x 97 85 34.1 2.9 312 281 108 130 35.5 4.6 460 414 100 175 36.6 6.4 597 538 93 220 37.8 8.3 726 653 87 240 38.2 9.2 780 702 85 300 39.5 11.8 931 838 79 BXRH-27H0600-B-8x 97 170 17.1 2.9 312 281 108 260 17.7 4.6 460 414 100 350 18.3 6.4 597 538 93 440 18.9 8.3 726 653 87 480 19.1 9.2 780 702 85 600 19.7 11.8 931 838 79 BXRH-30E0600-A-8x 80 85 34.1 2.9 454 409 156 130 35.5 4.6 668 601 145 175 36.6 6.4 868 781 136 220 37.8 8.3 1055 949 127 240 38.2 9.2 1133 1020 123 300 39.5 11.8 1352 1217 114 BXRH-30E0600-B-8x 80 170 17.1 2.9 454 409 156 260 17.7 4.6 668 601 145 350 18.3 6.4 868 781 136 440 18.9 8.3 1055 949 127 480 19.1 9.2 1133 1020 123 600 19.7 11.8 1352 1217 114 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRH-30G0600-A-8x 90 85 34.1 2.9 369 332 127 130 35.5 4.6 542 488 118 175 36.6 6.4 705 634 110 220 37.8 8.3 856 770 103 240 38.2 9.2 920 828 100 300 39.5 11.8 1098 988 93 BXRH-30G0600-B-8x 90 170 17.1 2.9 369 332 127 260 17.7 4.6 542 488 118 350 18.3 6.4 705 634 110 440 18.9 8.3 856 770 103 480 19.1 9.2 920 828 100 600 19.7 11.8 1098 988 93 BXRH-30H0600-A-8x 97 85 34.1 2.9 334 300 115 130 35.5 4.6 491 442 107 175 36.6 6.4 638 574 100 220 37.8 8.3 775 698 93 240 38.2 9.2 833 750 91 300 39.5 11.8 994 895 84 BXRH-30H0600-B-8x 97 170 17.1 2.9 334 300 115 260 17.7 4.6 491 442 107 350 18.3 6.4 638 574 100 440 18.9 8.3 775 698 93 480 19.1 9.2 833 750 91 600 19.7 11.8 994 895 84 BXRH-35E0600-A-8x 80 85 34.1 2.9 465 418 160 130 35.5 4.6 684 615 148 175 36.6 6.4 888 800 139 220 37.8 8.3 1079 971 130 240 38.2 9.2 1160 1044 126 300 39.5 11.8 1384 1246 117 BXRH-35E0600-B-8x 80 170 17.1 2.9 465 418 160 260 17.7 4.6 684 615 148 350 18.3 6.4 888 800 139 440 18.9 8.3 1079 971 130 480 19.1 9.2 1160 1044 126 600 19.7 11.8 1384 1246 117 BXRH-35G0600-A-8x 90 85 34.1 2.9 382 344 132 130 35.5 4.6 562 506 122 175 36.6 6.4 730 657 114 220 37.8 8.3 887 798 107 240 38.2 9.2 953 858 104 300 39.5 11.8 1138 1024 96 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRH-35G0600-B-8x 90 170 17.1 2.9 382 344 132 260 17.7 4.6 562 506 122 350 18.3 6.4 730 657 114 440 18.9 8.3 887 798 107 480 19.1 9.2 953 858 104 600 19.7 11.8 1138 1024 96 BXRH-35H0600-A-8x 97 85 34.1 2.9 343 309 118 130 35.5 4.6 505 454 110 175 36.6 6.4 656 590 102 220 37.8 8.3 797 717 96 240 38.2 9.2 856 771 93 300 39.5 11.8 1022 920 86 BXRH-35H0600-B-8x 97 170 17.1 2.9 343 309 118 260 17.7 4.6 505 454 110 350 18.3 6.4 656 590 102 440 18.9 8.3 797 717 96 480 19.1 9.2 856 771 93 600 19.7 11.8 1022 920 86 BXRH-40E0600-A-8x 80 85 34.1 2.9 467 421 161 130 35.5 4.6 688 619 149 175 36.6 6.4 894 804 140 220 37.8 8.3 1086 977 131 240 38.2 9.2 1166 1050 127 300 39.5 11.8 1392 1253 118 BXRH-40E0600-B-8x 80 170 17.1 2.9 467 421 161 260 17.7 4.6 688 619 149 350 18.3 6.4 894 804 140 440 18.9 8.3 1086 977 131 480 19.1 9.2 1166 1050 127 600 19.7 11.8 1392 1253 118 BXRH-40G0600-A-8x 90 85 34.1 2.9 390 351 134 130 35.5 4.6 574 516 124 175 36.6 6.4 745 671 116 220 37.8 8.3 906 815 109 240 38.2 9.2 973 876 106 300 39.5 11.8 1161 1045 98 BXRH-40G0600-B-8x 90 170 17.1 2.9 390 351 134 260 17.7 4.6 574 516 124 350 18.3 6.4 745 671 116 440 18.9 8.3 906 815 109 480 19.1 9.2 973 876 106 600 19.7 11.8 1161 1045 98 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRH-40H0600-A-8x 97 85 34.1 2.9 353 317 121 130 35.5 4.6 519 467 113 175 36.6 6.4 674 607 105 220 37.8 8.3 819 737 99 240 38.2 9.2 880 792 96 300 39.5 11.8 1050 945 89 BXRH-40H0600-B-8x 97 170 17.1 2.9 353 317 121 260 17.7 4.6 519 467 113 350 18.3 6.4 674 607 105 440 18.9 8.3 819 737 99 480 19.1 9.2 880 792 96 600 19.7 11.8 1050 945 89 BXRH-50E0601-A-8x 80 85 34.1 2.9 473 426 163 130 35.5 4.6 695 626 151 175 36.6 6.4 904 813 141 220 37.8 8.3 1098 988 132 240 38.2 9.2 1180 1062 129 300 39.5 11.8 1408 1267 119 BXRH-50E0601-B-8x 80 170 17.1 2.9 473 426 163 260 17.7 4.6 695 626 151 350 18.3 6.4 904 813 141 440 18.9 8.3 1098 988 132 480 19.1 9.2 1180 1062 129 600 19.7 11.8 1408 1267 119 BXRH-50G0601-A-8x 90 85 34.1 2.9 409 368 141 130 35.5 4.6 601 541 130 175 36.6 6.4 781 703 122 220 37.8 8.3 949 854 114 240 38.2 9.2 1019 918 111 300 39.5 11.8 1217 1095 103 BXRH-50G0601-B-8x 90 170 17.1 2.9 409 368 141 260 17.7 4.6 601 541 131 350 18.3 6.4 781 703 122 440 18.9 8.3 949 854 114 480 19.1 9.2 1019 918 111 600 19.7 11.8 1217 1095 103 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Electrical Characteristics

Table 5: Electrical Characteristics Part Number Drive Current (mA) Forward Voltage Pulsed, Tc = 25ºC (V) 1, 2, 3, 8 Typical Coefficient of Forward Voltage4 ∆Vf/∆Tc (mV/ºC) Typical Thermal Resistance Junction to Case5,6 Rj-c (ºC/W) Driver Selection Voltages7 (V) Minimum Typical Maximum Vf Min. Hot Tc = 105ºC (V) Vf Max. Cold Tc = -40ºC (V) BXRH-xxx060x-A-8x BXRH-xxx060x-B-8x Notes for Table 5: 1. Parts are tested in pulsed conditions, Tc = 25°C. Pulse width is 10ms. 2. Voltage minimum and maximum are provided for reference only and are not a guarantee of performance. 3. Bridgelux maintains a tester tolerance of ± 0.10V on forward voltage measurements. 4. Typical coefficient of forward voltage tolerance is ± 0.1mV for nominal current. 5. Thermal resistance values are based from test data of a 3000K 80 CRI product. 6. Thermal resistance value was calculated using total electrical input power; optical power was not subtracted from input power. The thermal interface material used during testing is not included in the thermal resistance value. 7. Vf min hot and max cold values are provided as reference only and are not guaranteed by test. These values are provided to aid in driver design and selection over the operating range of the product. 8. This product has been designed and manufactured per IEC 62031:2018. This product has passed dielectric withstand voltage testing at 500 V. The working voltage designated for the insulation is 50V d.c. The maximum allowable voltage across the array must be determined in the end product application.

Table 6: Eye Safety Risk Group (RG) Classifications Part Number Drive Current (mA) CCT1,3 2700K/3000K 4000K2 BXRH-xxx060x-A-8x

175 RG1 RG1

300 RG1 RG2

350 RG1 RG1

600 RG1 RG2

Notes for Table 6: 1. Eye safety classification for the use of Bridgelux V Series HD LED arrays is in accordance with specification IEC/TR 62778: Application of IEC 62471 for the assessment of blue light hazard to light sources and luminaires. 2. For products classified as RG2 at 4000K, Ethr= 1760 lx. 3. Please contact your Bridgelux sales representative for Ethr values at specific drive currents and CCTs not listed.

LED Junction Temperature (Tj) 125°C Storage Temperature -40°C to +105°C Operating Case Temperature1 (Tc) 105°C Soldering Temperature2 350°C or lower for a maximum of 6 seconds BXRH-xxx060x-A-8x BXRH-xxx060x-B-8x Maximum Drive Current3 300 mA 600 mA Maximum Peak Pulsed Drive Current4 340 mA 680 mA Maximum Reverse Voltage5 -60V -30V Notes for Table 7: 1. For IEC 62717 requirement, please consult your Bridgelux sales representative. 2. Refer to Bridgelux Application Note AN101: Handling and Assembly of Bridgelux V Series LED Arrays. 3. Arrays may be driven at higher currents however lumen maintenance may be reduced and warranty will not apply. 4. Bridgelux recommends a maximum duty cycle of 10% and pulse width of 20 ms when operating LED Arrays at maximum peak pulsed current specified. Maximum peak pulsed currents indicate values where LED Arrays can be driven without catastrophic failures. 5. Light emitting diodes are not designed to be driven in reverse voltage and will not produce light under this condition. Maximum rating provided for reference only. Table 7: Maximum Ratings

Figure 7: Typical DC ccy Shift vs. Case Temperature Figure 8: Derating Curve Performance Curves -0.0060 -0.0050 -0.0040 -0.0030 -0.0020 -0.0010 0.0000 0.0010 0 20 40 60 80 100 120 ccy shift Case Temperature (Tc) Notes for Figures 7: 1. Bridgelux does not recommend driving high power LEDs at low currents. Doing so may produce unpredictable results. Pulse width modulation (PWM) is recommended for dimming effects. 2. Characteristics shown for 3000K and 90 CRI. 100 200 300 400 500 600 700 0 20 40 60 80 100 120 Drive Current (mA) Case Temperature (Tc) BXRH-xxx060x-A-8x BXRH-xxx060x-B-8x

Figure 13: Drawing for V4 HD LED Array Notes for Figure 13: 1. Drawings are not to scale. 2. Drawing dimensions are in millimeters. 3. Solder pads are labeled “+” and “-“ to denote positive and negative polarity, respectively. 4. Unless otherwise specified, tolerances are ±0.1mm. 5. Refer to Application Notes AN101 for product handling, mounting and heat sink recommendations. 6. The optical center of the LED Array is nominally defined by the mechanical center of the array to a tolerance of ± 0.2mm. 7. Bridgelux maintains a flatness of 0.10mm across the mounting surface of the array.

Bin Code 2200K 2400K 2500K 2700K 3000K 3500K 4000K ANSI Bin (for reference only) (2207K-2309K) (2300K-2500K) - (2580K - 2870K) (2870K - 3220K) (3220K - 3710K) (3710K - 4260K) 83 (3 SDCM) (2207K-2309K) (2336K-2454K) - (2651K - 2794K) (2968K - 3136K) (3369K - 3586K) (3851K - 4130K) 82 (2 SDCM) (2224K-2291K) (2355K-2433K) - (2674K - 2769K) (2995K - 3107K) (3404K - 3548K) (3895K - 4081K) Table 8: Warm and Neutral White xy Bin Coordinates and Associated Typical CCT Figure 14: Warm and Neutral White Test Bins in xy Color Space Note: Pulsed Test Conditions, Tc = 25°C Note for Table 8-9: 1. Bridgelux maintains a tolerance of +/- 0.007 on x and y color coordinates in the CIE 1931 color Space. Note: Pulsed Test Conditions, Tc = 85°C Figure 15: Cool White Test Bins in xy Color Space 0.3 0.31 0.32 0.33 0.34 0.35 0.36 0.37 0.38 0.39 Y X

4 SDCM

3 SDCM

ANSI Bin (for reference only) (4745K - 5311K) 84 (4 SDCM) (4801K - 5282K) 83 (3 SDCM) (4835K - 5215K) Center Point (x,y) (0.3447, 0.3553) Table 9: Cool White xy Bin Coordinates and Associated Typical CCT (product is hot targeted to Tc = 85°C9

Figure 16: V4 HD Packaging Tube Notes for Figure 16: 1. Each tube holds 40 V4 HD COB arrays. 2. One tube is sealed in an anti-static bag. Four bags are placed in a shipping box. Depending on quantities ordered, a bigger shipping box, containing four boxes may be used to ship products. 3. Each bag and box is to be labeled as shown above. shipping box are 58.7 x 13.3 x 7.9 cm BXRH-30E0600-A-83 240

Figure 17: V Series HD Product Labeling Bridgelux COB arrays have laser markings on the back side of the substrate to help with product identification. In addition to the product identification markings, Bridgelux COB arrays also contain markings for internal Bridgelux manufacturing use only. The image below shows which markings are for customer use and which ones are for Bridgelux internal use only. The Bridgelux internal manufacturing markings are subject to change without notice, however these will not impact the form, function or performance of the COB array. Customer Use- 2D Barcode Scannable barcode provides product part number and other Bridgelux internal production information. Customer Use- Product part number 30E0600A 83 Internal Bin Code

Bridgelux has developed a comprehensive set of application notes and design resources to assist customers in successfully designing with the V Series product family of LED array products. For all available application notes visit www.bridgelux.com. Optical Source Models Optical source models and ray set files are available for all Bridgelux products. For a list of available formats, visit www.bridgelux.com. MINOR PRODUCT CHANGE POLICY The rigorous qualification testing on products offered by Bridgelux provides performance assurance. Slight cosmetic changes that do not affect form, fit, or function may occur as Bridgelux continues product optimization. CAUTION: CHEMICAL EXPOSURE HAZARD Exposure to some chemicals commonly used in luminaire manufacturing and assembly can cause damage to the LED array. Please consult Bridgelux CAUTION: RISK OF BURN Do not touch the V Series HD LED array during operation. Allow the array to cool for a sufficient period of time before handling. The V Series HD LED array may reach elevated temperatures such that could burn skin when touched. 3D CAD Models Three dimensional CAD models depicting the product outline of all Bridgelux V Series HD LED arrays are available in both IGS and STEP formats. Please contact your Bridgelux sales representative for assistance. LM80 LM80 testing has been completed and the LM80 report is now available. Please contact your Bridgelux sales rep- resentatives for LM-80 report. CAUTION CONTACT WITH LIGHT EMITTING SURFACE (LES) Avoid any contact with the LES. Do not touch the LES of the LED array or apply stress to the LES (yellow phosphor resin area). Contact may cause damage to the LED array. Optics and reflectors must not be mounted in contact with the LES (yellow phosphor resin area). STANDARD TEST CONDITIONS Unless otherwise stated, array testing is performed at the nominal drive current.

About Bridgelux: Bridging Light and Life™

46410 Fremont Boulevard

Fremont, CA 94538 USA Tel (925) 583-8400 www.bridgelux.com At Bridgelux, we help companies, industries and people experience the power and possibility of light. Since 2002, we’ve designed LED solutions that are high performing, energy efficient, cost effective and easy to integrate. Our focus is on light’s impact on human behavior, delivering products that create better environments, experiences and returns—both experiential and financial. And our patented technology drives new platforms for commercial and industrial luminaires. For more information about the company, please visit bridgelux.com twitter.com/Bridgelux facebook.com/Bridgelux youtube.com/user/Bridgelux linkedin.com/company/bridgelux-inc-_2 WeChat ID: BridgeluxInChina © 2025 Bridgelux, Inc. All rights reserved. Product specifications are subject to change without notice. Bridgelux, the Bridgelux stylized logo design, Vero, V Series and V Series HD are registered trademarks, and Decor Series is a trademark of Bridgelux, Inc. All other trademarks are the property of their respective owners. Bridgelux Gen V4 HD Array Series Product Data Sheet DS404 Rev. E (02/2025)