DS409 BRIDGELUX | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 21
Technical content
Datasheet sections
V Series™ HD LED array product, an ultra-high lumen density COB product line, is designed for high intensity spotlights used in commercial and retail settings. V Series HD arrays offer industry leading color over angle uniformity, and replace ceramic metal halide lamps by providing equal or greater center beam candle power at lower power and at greater lifetimes. Their tight beam control and exceptional quality of light is well suited for demanding directional spot applications. The V9 HD LED array is available in a variety of CCT and CRI combinations providing substantial design flexibility and energy efficiencies. Lighting system designs incorporating these LED arrays deliver increased system level efficacy and longer service life. Typical applications include, but are not limited to, commercial and residential down lights, accent, spot and track lights. Bridgelux Décor Series™ is our state of the art color line designed specifically for premium applications, producing unmatched LED light quality with brilliant color-rendering options and offer pleasing and inspiring lighting palettes. Bridgelux Décor Series color points are available on Vero® SE Series, Vero® Series, V Series™ and V Series™ HD. Décor Series™ Ultra products provide a high CRI of 97 and a minimum R9 value of 91, which emphasizes the reds and color tones to which the human eye is most receptive - perfect for the most luxurious retail shops and world renowned museums. Décor Series Ultra is designed as a replacement for halogen.
Features
- Efficacy of 141 lm/W typical
- Compact high flux density light source
- Uniform high quality illumination
- Minimum 80, 90 and 95 CRI options
- Streamlined thermal path
- ENERGY STAR® / ANSI compliant color binning structure with 3 SDCM options
- More energy efficient than incandescent, halogen and fluorescent lamps
- Low voltage DC operation
- Instant light with unlimited dimming
- V f bin code backside marking Benefits
- Enhanced optical control
- Clean white light without pixelation
- High quality true color reproduction
- Significantly reduced thermal resistance and increased operating temperatures
- Uniform consistent white light
- Lower operating costs
- Easy to use with daylight and motion detectors to enable increased energy savings
- Reduced maintenance costs
- Environmentally friendly, no disposal issue
The part number designation for Bridgelux V Series HD LED arrays is explained as follows: 1 2 3 4 5 6 7 8 9 10 11 – 12 – 13 14 Product Family CCT Bin Options 3 = 3 SDCM CRI E = 80 CRI min. G = 90 CRI min. H = 97 CRI typ. Array Configuration 27 = 2,700K 30 = 3,000K 35 = 3,500K 40 = 4,000K BXRH – 30 E 400 0 – F – 8 3 Color Targeting Designator 0 = Cold Targeted 1 = Hot Targeted Gen. 8Nominal CCT Flux Indicator 400x = 4000 lm Fully engineered substrate for consistent thermal, mechanical and optical properties Yellow phosphor Light Emitting Surface (LES) Note: Part number and lot codes are scribed on back of array Polarity symbols Solder Pads White ring around LES Case Temperature (Tc) Measurement Point Designed to comply with global safety standards for creepage and clearance distances The arrays incorporate several features to simplify design integration and assembly. Please visit www.bridgelux.com for more information on the V Series HD family of products. Bridgelux arrays are fully engineered devices that provide consistent thermal and optical performance on an engineered mechanical platform. The V Series HD arrays are the most compact chip-on-board devices across all of Bridgelux’s LED Array products.
The following product configurations are available: Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 Tc = 25ºC (lm) Minimum Pulsed Flux6,7 Tc = 25ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRH-27E4000-F-83 2700 80 1050 5092 4583 36.6 38.4 132 BXRH-27G4000-F-83 2700 90 1050 4360 3924 36.6 38.4 113 BXRH-27H4000-F-83 2700 97 1050 3723 3351 36.6 38.4 97 BXRH-30E4000-F-83 3000 80 1050 5410 4869 36.6 38.4 141 BXRH-30G4000-F-83 3000 90 1050 4583 4124 36.6 38.4 119 BXRH-30H4000-F-83 3000 97 1050 3978 3580 36.6 38.4 104 BXRH-35E4000-F-83 3500 80 1050 5537 4984 36.6 38.4 144 BXRH-35G4000-F-83 3500 90 1050 4778 4300 36.6 38.4 124 BXRH-35H4000-F-83 3500 97 1050 4089 3680 36.6 38.4 106 BXRH-40E4000-F-83 4000 80 1050 5569 5012 36.6 38.4 145 BXRH-40G4000-F-83 4000 90 1050 4833 4349 36.6 38.4 126 BXRH-40H4000-F-83 4000 97 1050 4201 3781 36.6 38.4 109 BXRH-50E4001-F-84 5000 80 1050 5633 5069 36.6 38.4 147 BXRH-50G4001-F-84 5000 90 1050 4868 4381 36.6 38.4 127 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. 2. CRI values are typical for Decor Series Ultra and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI products is 91. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test.
Table 2: Selection Guide, Stabilized DC Performance (Tc = 85°C) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85ºC (lm) Minimum DC Flux6 Tc = 85ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRH-27E4000-F-83 2700 80 1050 4583 4124 35.4 37.2 123 BXRH-27G4000-F-83 2700 90 1050 3924 3531 35.4 37.2 106 BXRH-27H4000-F-83 2700 97 1050 3351 3016 35.4 37.2 90 BXRH-30E4000-F-83 3000 80 1050 4869 4382 35.4 37.2 131 BXRH-30G4000-F-83 3000 90 1050 4124 3712 35.4 37.2 111 BXRH-30H4000-F-83 3000 97 1050 3580 3222 35.4 37.2 96 BXRH-35E4000-F-83 3500 80 1050 4984 4485 35.4 37.2 134 BXRH-35G4000-F-83 3500 90 1050 4300 3870 35.4 37.2 116 BXRH-35H4000-F-83 3500 97 1050 3680 3312 35.4 37.2 99 BXRH-40E4000-F-83 4000 80 1050 5012 4511 35.4 37.2 135 BXRH-40G4000-F-83 4000 90 1050 4349 3915 35.4 37.2 117 BXRH-40H4000-F-83 4000 97 1050 3781 3403 35.4 37.2 102 BXRH-50E4001-F-84 5000 80 1050 5069 4562 35.4 37.2 136 BXRH-50G4001-F-84 5000 90 1050 4381 3943 35.4 37.2 118 Notes for Table 2: 1. Nominal CCT as defined by ANSI C78.377-2011. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI products is 91. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.
Performance at Commonly Used Drive Currents V Series HD LED arrays are tested to the specifications shown using the nominal drive currents in Table 1. V Series HD LED arrays may also be driven at other drive currents dependent on specific application design requirements. The perfor- mance at any drive current can be derived from the current vs. voltage characteristics shown in Figure 1 and the flux vs. current characteristics shown in Figure 2. The performance at commonly used drive currents is summarized in Table 3. Table 3: Product Performance at Commonly Used Drive Currents Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRH-27E4000-F-83 80 525 34.2 18.0 2703 2432 150 750 35.3 26.5 3763 3387 142 1050 36.6 38.4 5092 4583 132 1313 37.7 49.5 6184 5565 125 1440 38.2 55.1 6687 6018 121 1800 39.5 71.1 8016 7215 113 BXRH-27G4000-F-83 90 525 34.2 18.0 2314 2083 129 750 35.3 26.5 3222 2900 122 1050 36.6 38.4 4360 3924 113 1313 37.7 49.5 5295 4765 107 1440 38.2 55.1 5726 5153 104 1800 39.5 71.1 6864 6178 97 BXRH-27H4000-F-83 97 525 34.2 18.0 1976 1779 110 750 35.3 26.5 2752 2476 104 1050 36.6 38.4 3723 3351 97 1313 37.7 49.5 4522 4070 91 1440 38.2 55.1 4890 4401 89 1800 39.5 71.1 5862 5276 82 BXRH-30E4000-F-83 80 525 34.2 18.0 2872 2584 160 750 35.3 26.5 3998 3598 151 1050 36.6 38.4 5410 4869 141 1313 37.7 49.5 6570 5913 133 1440 38.2 55.1 7105 6394 129 1800 39.5 71.1 8517 7666 120 BXRH-30G4000-F-83 90 525 34.2 18.0 2432 2189 135 750 35.3 26.5 3387 3048 128 1050 36.6 38.4 4583 4124 119 1313 37.7 49.5 5565 5009 112 1440 38.2 55.1 6018 5416 109 1800 39.5 71.1 7215 6493 102 BXRH-30H4000-F-83 97 525 34.2 18.0 2111 1900 118 750 35.3 26.5 2940 2646 111 1050 36.6 38.4 3978 3580 104 1313 37.7 49.5 4831 4348 98 1440 38.2 55.1 5224 4702 95 1800 39.5 71.1 6263 5637 88 Notes for Table 3: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
Performance at Commonly Used Drive Currents Table 3: Product Performance at Commonly Used Drive Currents (continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRH-35E4000-F-83 80 525 34.2 18.0 2939 2645 164 750 35.3 26.5 4092 3683 155 1050 36.6 38.4 5537 4984 144 1313 37.7 49.5 6725 6052 136 1440 38.2 55.1 7272 6545 132 1800 39.5 71.1 8718 7846 123 BXRH-35G4000-F-83 90 525 34.2 18.0 2536 2283 141 750 35.3 26.5 3531 3178 133 1050 36.6 38.4 4778 4300 124 1313 37.7 49.5 5803 5223 117 1440 38.2 55.1 6275 5648 114 1800 39.5 71.1 7523 6771 106 BXRH-35H4000-F-83 97 525 34.2 18.0 2171 1954 121 750 35.3 26.5 3022 2720 114 1050 36.6 38.4 4089 3680 106 1313 37.7 49.5 4966 4470 100 1440 38.2 55.1 5370 4833 98 1800 39.5 71.1 6438 5794 91 BXRH-40E4000-F-83 80 525 34.2 18.0 2956 2660 165 750 35.3 26.5 4116 3704 155 1050 36.6 38.4 5569 5012 145 1313 37.7 49.5 6763 6087 137 1440 38.2 55.1 7314 6582 133 1800 39.5 71.1 8768 7891 123 BXRH-40G4000-F-83 90 525 34.2 18.0 2565 2309 143 750 35.3 26.5 3571 3214 135 1050 36.6 38.4 4833 4349 126 1313 37.7 49.5 5869 5282 118 1440 38.2 55.1 6347 5712 115 1800 39.5 71.1 7609 6848 107 BXRH-40H4000-F-83 97 525 34.2 18.0 2230 2007 124 750 35.3 26.5 3104 2794 117 1050 36.6 38.4 4201 3781 109 1313 37.7 49.5 5102 4591 103 1440 38.2 55.1 5517 4965 100 1800 39.5 71.1 6614 5952 93 Notes for Table 3: 1. Alternate drive currents in Table 3 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
Performance at Commonly Used Drive Currents Table 3: Product Performance at Commonly Used Drive Currents (continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRH-50E4001-F-84 80 525 34.2 18.0 2990 2690 167 750 35.3 26.5 4162 3746 157 1050 36.6 38.4 5633 5069 147 1313 37.7 49.5 6840 6156 138 1440 38.2 55.1 7397 6657 134 1800 39.5 71.1 8867 7981 125 BXRH-50G4001-F-84 90 525 34.2 18.0 2584 2325 144 750 35.3 26.5 3597 3238 136 1050 36.6 38.4 4868 4381 127 1313 37.7 49.5 5912 5321 119 1440 38.2 55.1 6393 5753 116 1800 39.5 71.1 7664 6898 108 Notes for Table 3: 1. Alternate drive currents in Table 3 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
Electrical Characteristics
Table 4: Electrical Characteristics Part Number Drive Current (mA) Forward Voltage Pulsed, Tc = 25ºC (V) 1, 2, 3, 8 Typical Coefficient of Forward Voltage4 ∆Vf/∆Tc (mV/ºC) Typical Thermal Resistance Junction to Case5,6 Rj-c (ºC/W) Driver Selection Voltages7 (V) Minimum Typical Maximum Vf Min. Hot Tc = 105ºC (V) Vf Max. Cold Tc = -40ºC (V) BXRH-xxx40xx-F-83 Notes for Table 4: 1. Parts are tested in pulsed conditions, Tc = 25°C. Pulse width is 10ms. 2. Voltage minimum and maximum are provided for reference only and are not a guarantee of performance. 3. Bridgelux maintains a tester tolerance of ± 0.10V on forward voltage measurements. 4. Typical coefficient of forward voltage tolerance is ± 0.1mV for nominal current. 5. Thermal resistance values are based from test data of a 3000K 80 CRI product. 6. Thermal resistance value was calculated using total electrical input power; optical power was not subtracted from input power. The thermal interface material used during testing is not included in the thermal resistance value. 7. Vf min hot and max cold values are provided as reference only and are not guaranteed by test. These values are provided to aid in driver design and selection over the operating range of the product. 8. This product has been designed and manufactured per IEC 62031:2018. This product has passed dielectric withstand voltage testing at 500 V. The working voltage designated for the insulation is 50V d.c. The maximum allowable voltage across the array must be determined in the end product application.
Table 5: Eye Safety Risk Group (RG) Classifications Part Number Drive Current (mA) CCT1,4 2700K/3000K2 4000K3 BXRH-xxx40xx-F-83
1050 RG1 RG2
1400 RG1 RG2
Notes for Table 5: 1. Eye safety classification for the use of Bridgelux V Series HD LED arrays is in accordance with specification IEC/TR 62778: Application of IEC 62471 for the assessment of blue light hazard to light sources and luminaires. 2. For products classified as RG2 at 3000K, Ethr= 2670 lx. 3. For products classified as RG2 at 4000K, Ethr= 1760 lx. 4. Please contact your Bridgelux sales representative for Ethr values at specific drive currents and CCTs not listed.
LED Junction Temperature (Tj) 125°C Storage Temperature -40°C to +105°C Operating Case Temperature1 (Tc) 105°C Soldering Temperature2 300°C or lower for a maximum of 6 seconds BXRH-xxx40xx-F-83 Maximum Drive Current3 1800 mA Maximum Peak Pulsed Drive Current4 2036 mA Maximum Reverse Voltage5 -60V Notes for Table 6: 1. For IEC 62717 requirement, please consult your Bridgelux sales representative. 2. Refer to Bridgelux Application Note AN101: Handling and Assembly of Bridgelux V Series LED Arrays. 3. Arrays may be driven at higher currents however lumen maintenance may be reduced and warranty will not apply. 4. Bridgelux recommends a maximum duty cycle of 10% and pulse width of 20 ms when operating LED Arrays at maximum peak pulsed current specified. Maximum peak pulsed currents indicate values where LED Arrays can be driven without catastrophic failures. 5. Light emitting diodes are not designed to be driven in reverse voltage and will not produce light under this condition. Maximum rating provided for reference only. Table 6: Maximum Ratings
Figure 11: Drawing for V11 HD LED Array Notes for Figure 11: 1. Drawings are not to scale. 2. Drawing dimensions are in millimeters. 3. Solder pads are labeled “+” and “-“ to denote positive and negative polarity, respectively. 4. Unless otherwise specified, tolerances are ±0.1mm. 5. Refer to Application Notes AN101 for product handling, mounting and heat sink recommendations. 6. The optical center of the LED Array is nominally defined by the mechanical center of the array to a tolerance of ± 0.2mm. 7. Bridgelux maintains a flatness of 0.10mm across the mounting surface of the array.
Bin Code 2700K 3000K 3500K 4000K ANSI Bin (for reference only) (2580K - 2870K) (2870K - 3220K) (3220K - 3710K) (3710K - 4260K) 83 (3 SDCM) (2651K - 2794K) (2968K - 3136K) (3369K - 3586K) (3851K - 4130K) 82 (2 SDCM) (2674K - 2769K) (2995K - 3107K) (3404K - 3548K) (3895K - 4081K) Table 7: Warm and Neutral White xy Bin Coordinates and Associated Typical CCT Figure 12: Warm and Neutral White Test Bins in xy Color Space Note: Pulsed Test Conditions, Tc = 25°C Note for Table 7-8: 1. Bridgelux maintains a tolerance of +/- 0.007 on x and y color coordinates in the CIE 1931 color Space. Note: Pulsed Test Conditions, Tc = 85°C Figure 13: Cool White Test Bins in xy Color Space 0.3 0.31 0.32 0.33 0.34 0.35 0.36 0.37 0.38 0.39 Y X
4 SDCM
3 SDCM
Bin Code 5000K 5700K 6500K ANSI Bin (for reference only) (4745K - 5311K) (5312K - 6022K) (6022K - 7042K) 84 (4 SDCM) (4801K - 5282K) (5395K- 5970K) (6200K - 6910K) 83 (3 SDCM) (4835K - 5215K) (5460K- 5891K) (6279K -6811K) Table 8: Cool White xy Bin Coordinates and Associated Typical CCT (product is hot targeted to Tc = 85°C9
Figure 14: V11 HD Packaging Tube Notes for Figure 14: 1. Each tube holds 25 V11 HD COB arrays. 2. One tube is sealed in an anti-static bag. Four bags are placed in a shipping box. Depending on quantities ordered, a bigger shipping box, containing four boxes may be used to ship products. 3. Each bag and box is to be labeled as shown above. shipping box are 58.7 x 13.3 x 7.9 cm BXRH-30E3000-D-83 960
Figure 15: V Series HD Product Labeling Bridgelux COB arrays have laser markings on the back side of the substrate to help with product identification. In addition to the product identification markings, Bridgelux COB arrays also contain markings for internal Bridgelux manufacturing use only. The image below shows which markings are for customer use and which ones are for Bridgelux internal use only. The Bridgelux internal manufacturing markings are subject to change without notice, however these will not impact the form, function or performance of the COB array. Customer Use- 2D Barcode Scannable barcode provides product part number and other Bridgelux internal production information. Customer Use- Product part number 30E4000F 83 Internal Bin Code
Bridgelux has developed a comprehensive set of application notes and design resources to assist customers in successfully designing with the V Series product family of LED array products. For all available application notes visit www.bridgelux.com. Optical Source Models Optical source models and ray set files are available for all Bridgelux products. For a list of available formats, visit www.bridgelux.com. MINOR PRODUCT CHANGE POLICY The rigorous qualification testing on products offered by Bridgelux provides performance assurance. Slight cosmetic changes that do not affect form, fit, or function may occur as Bridgelux continues product optimization. CAUTION: CHEMICAL EXPOSURE HAZARD Exposure to some chemicals commonly used in luminaire manufacturing and assembly can cause damage to the LED array. Please consult Bridgelux CAUTION: RISK OF BURN Do not touch the V Series HD LED array during operation. Allow the array to cool for a sufficient period of time before handling. The V Series HD LED array may reach elevated temperatures such that could burn skin when touched. 3D CAD Models Three dimensional CAD models depicting the product outline of all Bridgelux V Series HD LED arrays are available in both IGS and STEP formats. Please contact your Bridgelux sales representative for assistance. LM80 LM80 testing has been completed and the LM80 report is now available. Please contact your Bridgelux sales rep- resentatives for LM-80 report. CAUTION CONTACT WITH LIGHT EMITTING SURFACE (LES) Avoid any contact with the LES. Do not touch the LES of the LED array or apply stress to the LES (yellow phosphor resin area). Contact may cause damage to the LED array. Optics and reflectors must not be mounted in contact with the LES (yellow phosphor resin area). STANDARD TEST CONDITIONS Unless otherwise stated, array testing is performed at the nominal drive current.
About Bridgelux: Bridging Light and Life™
46410 Fremont Boulevard
Fremont, CA 94538 USA Tel (925) 583-8400 www.bridgelux.com At Bridgelux, we help companies, industries and people experience the power and possibility of light. Since 2002, we’ve designed LED solutions that are high performing, energy efficient, cost effective and easy to integrate. Our focus is on light’s impact on human behavior, delivering products that create better environments, experiences and returns—both experiential and financial. And our patented technology drives new platforms for commercial and industrial luminaires. For more information about the company, please visit bridgelux.com twitter.com/Bridgelux facebook.com/Bridgelux youtube.com/user/Bridgelux linkedin.com/company/bridgelux-inc-_2 WeChat ID: BridgeluxInChina © 2023 Bridgelux, Inc. All rights reserved. Product specifications are subject to change without notice. Bridgelux, the Bridgelux stylized logo design, Vero, V Series and V Series HD are registered trademarks, and Decor Series is a trademark of Bridgelux, Inc. All other trademarks are the property of their respective owners. Bridgelux Gen 8 V11 HD Array Series Product Data Sheet DS409 Rev. D (10/2023)