DS407 BRIDGELUX | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 30

Technical content

Datasheet sections

V Series™ HD LED array product, an ultra-high lumen density COB product line, is designed for high intensity spotlights used in commercial and retail settings. V Series HD arrays offer industry leading color over angle uniformity, and replace ceramic metal halide lamps by providing equal or greater center beam candle power at lower power and at greater lifetimes. Their tight beam control and exceptional quality of light is well suited for demanding directional spot applications. The V6 HD LED array is available in a variety of CCT and CRI combinations providing substantial design flexibility and energy efficiencies. Lighting system designs incorporating these LED arrays deliver increased system level efficacy and longer service life. Typical applications include, but are not limited to, commercial and residential down lights, accent, spot and track lights. Bridgelux Décor Series™ is our state of the art color line designed specifically for premium applications, producing unmatched LED light quality with brilliant color-rendering options and offer pleasing and inspiring lighting palettes. Bridgelux Décor Series color points are available on Vero® SE Series, Vero® Series, V Series™ and V Series™ HD. Décor Series™ Ultra products provide a high CRI of 97 and a minimum R9 value of 91, which emphasizes the reds and color tones to which the human eye is most receptive - perfect for the most luxurious retail shops and world renowned museums. Décor Series Ultra is designed as a replacement for halogen.

Features

  • Efficacy of 140 lm/W typical
  • Compact high flux density light source
  • Uniform high quality illumination
  • Minimum 80, 90 and 95 CRI options
  • Streamlined thermal path
  • ENERGY STAR® / ANSI compliant color binning structure with 3 SDCM options
  • More energy efficient than incandescent, halogen and fluorescent lamps
  • Low voltage DC operation
  • Instant light with unlimited dimming Benefits
  • Enhanced optical control
  • Clean white light without pixelation
  • High quality true color reproduction
  • Significantly reduced thermal resistance and increased operating temperatures
  • Uniform consistent white light
  • Lower operating costs
  • Easy to use with daylight and motion detectors to enable increased energy savings
  • Reduced maintenance costs
  • Environmentally friendly, no disposal issue

The part number designation for Bridgelux V Series HD LED arrays is explained as follows: 1 2 3 4 5 6 7 8 9 10 11 – 12 – 13 14 Product Family CCT Bin Options 3 = 3 SDCM 4 = 4 SDCM CRI E = 80 CRI min. G = 90 CRI min. H = 97 CRI typ. Array Configuration 27 = 2,700K 30 = 3,000K 35 = 3,500K 40 = 4,000K 50 = 5,000K BXRH – 30 E 100 0 – B – 8 3 Color Targeting Designator 0 = Cold Targeted 1 = Hot Targeted Gen. 8Nominal CCT Flux Indicator 10xx = 1000 lm Fully engineered substrate for consistent thermal, mechanical and optical properties Yellow phosphor Light Emitting Surface (LES) Note: Part number and lot codes are scribed on back of array Solder Pads White ring around LES Case Temperature (Tc) Measurement Point Designed to comply with global safety standards for creepage and clearance distances The arrays incorporate several features to simplify design integration and assembly. Please visit www.bridgelux.com for more information on the V Series HD family of products. Bridgelux arrays are fully engineered devices that provide consistent thermal and optical performance on an engineered mechanical platform. The V Series HD arrays are the most compact chip-on-board devices across all of Bridgelux’s LED Array products. Polarity symbols

The following product configurations are available: Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 Tc = 25ºC (lm) Minimum Pulsed Flux6,7 Tc = 25ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRH-22G1000-B-8x 2200 90 350 1160 1044 36.6 12.8 91 BXRH-22G1000-G-8x 2200 90 700 1160 1044 18.3 12.8 91 BXRH-22H1000-B-8x 2200 97 350 980 882 36.6 12.8 77 BXRH-22H1000-G-8x 2200 97 700 980 882 18.3 12.8 77 BXRH-24G1000-B-8x 2400 90 350 1240 1116 36.6 12.8 97 BXRH-24G1000-G-8x 2400 90 700 1240 1116 18.3 12.8 97 BXRH-24H1000-B-8x 2400 97 350 1050 945 36.6 12.8 82 BXRH-24H1000-G-8x 2400 97 700 1050 945 18.3 12.8 82 BXRH-27E1000-B-8x 2700 80 350 1691 1522 36.6 12.8 132 BXRH-27E1000-G-8x 2700 80 700 1691 1522 18.3 12.8 132 BXRH-27G1000-B-8x 2700 90 350 1395 1256 36.6 12.8 109 BXRH-27G1000-G-8x 2700 90 700 1395 1256 18.3 12.8 109 BXRH-27G10H0-B-8x 2700 90 350 1448 1303 36.6 12.8 113 BXRH-27G10H0-G-8x 2700 90 700 1448 1303 18.3 12.8 113 BXRH-27H1000-B-8x 2700 97 350 1237 1113 36.6 12.8 97 BXRH-27H1000-G-8x 2700 97 700 1237 1113 18.3 12.8 97 BXRH-30E1000-B-8x 3000 80 350 1797 1617 36.6 12.8 140 BXRH-30E1000-G-8x 3000 80 700 1797 1617 18.3 12.8 140 BXRH-30G1000-B-8x 3000 90 350 1459 1313 36.6 12.8 114 BXRH-30G1000-G-8x 3000 90 700 1459 1313 18.3 12.8 114 BXRH-30G10H0-B-8x 3000 90 350 1522 1370 36.6 12.8 119 BXRH-30G10H0-G-8x 3000 90 700 1522 1370 18.3 12.8 119 BXRH-30H1000-B-8x 3000 97 350 1321 1189 36.6 12.8 103 BXRH-30H1000-G-8x 3000 97 700 1321 1189 18.3 12.8 103 BXRH-35E1000-B-8x 3500 80 350 1839 1655 36.6 12.8 144 BXRH-35E1000-G-8x 3500 80 700 1839 1655 18.3 12.8 144 BXRH-35G1000-B-8x 3500 90 350 1512 1360 36.6 12.8 118 BXRH-35G1000-G-8x 3500 90 700 1512 1360 18.3 12.8 118 BXRH-35H1000-B-8x 3500 97 350 1358 1222 36.6 12.8 106 BXRH-35H1000-G-8x 3500 97 700 1358 1222 18.3 12.8 106 BXRH-40E1000-B-8x 4000 80 350 1850 1665 36.6 12.8 144 BXRH-40E1000-G-8x 4000 80 700 1850 1665 18.3 12.8 144 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. 2. CRI values are typical for Decor Series Ultra. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI products is 91. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal drive current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test.

Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C)(Continued) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 Tc = 25ºC (lm) Minimum Pulsed Flux6,7 Tc = 25ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRH-40G1000-B-8x 4000 90 350 1543 1389 36.6 12.8 120 BXRH-40G1000-G-8x 4000 90 700 1543 1389 18.3 12.8 120 BXRH-40H1000-B-8x 4000 97 350 1395 1256 36.6 12.8 109 BXRH-40H1000-G-8x 4000 97 700 1395 1256 18.3 12.8 109 BXRH-50E1001-B-8x 5000 80 350 1869 1682 36.6 12.4 146 BXRH-50E1001-G-8x 5000 80 700 1869 1682 18.3 12.4 146 BXRH-50G1001-B-8x 5000 90 350 1543 1389 36.6 12.8 120 BXRH-50G1001-G-8x 5000 90 700 1543 1389 18.3 12.8 120 BXRH-57E1001-B-8x 5700 80 350 1797 1617 36.6 12.8 140 BXRH-57E1001-G-8x 5700 80 700 1797 1617 18.3 12.8 140 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. 2. CRI values are typical for Decor Series Ultra. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI products is 91. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal drive current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test.

Table 2: Selection Guide, Stabilized DC Performance (Tc = 85°C) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85ºC (lm) Minimum DC Flux6 Tc = 85ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRH-22G1000-B-8x 2200 90 350 1044 940 35.4 12.4 84 BXRH-22G1000-G-8x 2200 90 700 1044 940 17.7 12.4 84 BXRH-22H1000-B-8x 2200 97 350 882 794 35.4 12.4 71 BXRH-22H1000-G-8x 2200 97 700 882 794 17.7 12.4 71 BXRH-24G1000-B-8x 2400 90 350 1116 1004 35.4 12.4 90 BXRH-24G1000-G-8x 2400 90 700 1116 1004 17.7 12.4 90 BXRH-24H1000-B-8x 2400 97 350 945 851 35.4 12.4 76 BXRH-24H1000-G-8x 2400 97 700 945 851 17.7 12.4 76 BXRH-27E1000-B-8x 2700 80 350 1522 1370 35.4 12.4 123 BXRH-27E1000-G-8x 2700 80 700 1522 1370 17.7 12.4 123 BXRH-27G1000-B-8x 2700 90 350 1256 1130 35.4 12.4 101 BXRH-27G1000-G-8x 2700 90 700 1256 1130 17.7 12.4 101 BXRH-27G10H0-B-8x 2700 90 350 1303 1173 35.4 12.4 105 BXRH-27G10H0-G-8x 2700 90 700 1303 1173 17.7 12.4 105 BXRH-27H1000-B-8x 2700 97 350 1113 1002 35.4 12.4 90 BXRH-27H1000-G-8x 2700 97 700 1113 1002 17.7 12.4 90 BXRH-30E1000-B-8x 3000 80 350 1617 1456 35.4 12.4 131 BXRH-30E1000-G-8x 3000 80 700 1617 1456 17.7 12.4 131 BXRH-30G1000-B-8x 3000 90 350 1313 1182 35.4 12.4 106 BXRH-30G1000-G-8x 3000 90 700 1313 1182 17.7 12.4 106 BXRH-30G10H0-B-8x 3000 90 350 1370 1233 35.4 12.4 111 BXRH-30G10H0-G-8x 3000 90 700 1370 1233 17.7 12.4 111 BXRH-30H1000-B-8x 3000 97 350 1189 1070 35.4 12.4 96 BXRH-30H1000-G-8x 3000 97 700 1189 1070 17.7 12.4 96 BXRH-35E1000-B-8x 3500 80 350 1655 1490 35.4 12.4 134 BXRH-35E1000-G-8x 3500 80 700 1655 1490 17.7 12.4 134 BXRH-35G1000-B-8x 3500 90 350 1360 1224 35.4 12.4 110 BXRH-35G1000-G-8x 3500 90 700 1360 1224 17.7 12.4 110 BXRH-35H1000-B-8x 3500 97 350 1222 1100 35.4 12.4 99 BXRH-35H1000-G-8x 3500 97 700 1222 1100 17.7 12.4 99 BXRH-40E1000-B-8x 4000 80 350 1665 1498 35.4 12.4 134 BXRH-40E1000-G-8x 4000 80 700 1665 1498 17.7 12.4 134 Notes for Table 2: 1. Nominal CCT as defined by ANSI C78.377-2011. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra . CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI products is 91. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.

Table 2: Selection Guide, Stabilized DC Performance (Tc = 85°C) (Continued) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85ºC (lm) Minimum DC Flux6 Tc = 85ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRH-40G1000-B-8x 4000 90 350 1389 1250 35.4 12.4 112 BXRH-40G1000-G-8x 4000 90 700 1389 1250 17.7 12.4 112 BXRH-40H1000-B-8x 4000 97 350 1256 1130 35.4 12.4 101 BXRH-40H1000-G-8x 4000 97 700 1256 1130 17.7 12.4 101 BXRH-50E1001-B-8x 5000 80 350 1682 1513 35.4 12.4 136 BXRH-50E1001-G-8x 5000 80 700 1682 1513 17.7 12.4 136 BXRH-50G1001-B-8x 5000 90 350 1389 1250 35.4 12.4 112 BXRH-50G1001-G-8x 5000 90 700 1389 1250 17.7 12.4 112 BXRH-57E1001-B-8x 5700 80 350 1617 1456 35.4 12.4 131 BXRH-57E1001-G-8x 5700 80 700 1617 1456 17.7 12.4 131 Notes for Table 2: 1. Nominal CCT as defined by ANSI C78.377-2011. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra . CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI products is 91. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.

European Product Registry for Energy Labeling The European Product Registry for Energy Labeling (EPREL) is defined in the EU Regulation 2017/1369 to provide import- ant energy efficiency information to consumers. Together with Energy Labeling Regulation ELR (EU) 2019/2015 which was amended by regulation (EU) 2021/340 for energy labelling of light sources, manufacturers are required to declare an ener- gy class based on key technical specifications from each of their product and register it in an open data base managed by EPREL It is now a legal requirement for a vendor of light sources to upload information about their products into the EPREL database before placing these products on the market in the EU. Table 3 below provides a list of part numbers that are in compliance with ELR and are currently listed in the EPREL data- base. At Bridgelux, we are fully committed to supplying products that are compliant with pertinent laws, rules, and obligation imposed by relevant government bodies including the European Energy Labeling regulation. Customers can use these products with full confidence for any projects that fall under the ELR. Table 3: Part numbers registered in European Product Registry for Energy Labeling PART NUMBER1 CCT (K) CRI Current2 (mA) Vf (V) Useful flux3 (Φuse) at 85C (lm) Pow- er (W) Efficacy (lm/W) Energy efficiency class4 Regis- tration No URL to Product Information Sheet in EPREL Database Notes for Table 3: 1. All device listed here must be disposed as e-waste upon its end of life according to local country guideline in each country. 2. For information on performance values at alternative drive conditions. please refer to the Product Selection Guide, Absolute Maximum Rating Table and Performance Curves in this data sheet. 3. For a definition of useful luminous flux (ΦΦuse), please see the ELR regulations at https:/ /tinyurl.com/4b6zvt4m. 4. EPREL requires an arrow symbol containing the letter of the energy efficiency class to be displayed. on technical promotional material. Refer to this energy efficiency class column for specific energy efficiency class on each part number.

European Product Registry for Energy Labeling Table 3: Part numbers registered in European Product Registry for Energy Labeling (Continued) PART NUMBER1 CCT (K) CRI Current2 (mA) Vf (V) Useful flux3 (Φuse) at 85C (lm) Pow- er (W) Efficacy (lm/W) Energy efficiency class4 Regis- tration No URL to Product Information Sheet in EPREL Database Notes for Table 3: 1. All device listed here must be disposed as e-waste upon its end of life according to local country guideline in each country. 2. For information on performance values at alternative drive conditions. please refer to the Product Selection Guide, Absolute Maximum Rating Table and Performance Curves in this data sheet. 3. For a definition of useful luminous flux (ΦΦuse), please see the ELR regulations at https:/ /tinyurl.com/4b6zvt4m. 4. EPREL requires an arrow symbol containing the letter of the energy efficiency class to be displayed. on technical promotional material. Refer to this energy efficiency class column for specific energy efficiency class on each part number.

Performance at Commonly Used Drive Currents V Series HD LED arrays are tested to the specifications shown using the nominal drive currents in Table 1. V Series HD LED arrays may also be driven at other drive currents dependent on specific application design requirements. The performance at any drive current can be derived from the current vs. voltage characteristics shown in Figures 1 & 2 and the flux vs. cur- rent characteristics shown in Figures 3 & 4. The performance at commonly used drive currents is summarized in Table 4. Table 4: Product Performance at Commonly Used Drive Currents Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRH-22G1000-B-8x 90 175 34.2 6.0 619 557 103 250 35.3 8.8 862 776 98 350 36.6 12.8 1160 1044 91 440 37.8 16.6 1423 1281 86 480 38.2 18.3 1532 1379 84 600 39.5 23.7 1837 1653 78 BXRH-22G1000-G-8x 90 350 17.1 6.0 619 557 103 500 17.7 8.9 862 776 97 700 18.3 12.8 1160 1044 91 880 18.9 16.6 1423 1281 86 960 19.1 18.3 1532 1379 84 1200 19.7 23.6 1837 1653 78 BXRH-22H1000-B-8x 97 175 34.2 6.0 523 471 87 250 35.3 8.8 728 656 83 350 36.6 12.8 980 882 77 440 37.8 16.6 1203 1082 72 480 38.2 18.3 1294 1165 71 600 39.5 23.7 1552 1397 65 BXRH-22H1000-G-8x 97 350 17.1 6.0 523 471 87 500 17.7 8.9 728 656 82 700 18.3 12.8 980 882 77 880 18.9 16.6 1203 1082 72 960 19.1 18.3 1294 1165 71 1200 19.7 23.6 1552 1397 66 BXRH-24G1000-B-8x 90 175 34.2 6.0 662 596 111 250 35.3 8.8 922 830 104 350 36.6 12.8 1240 1116 97 440 37.8 16.6 1522 1369 91 480 38.2 18.3 1637 1474 89 600 39.5 23.7 1964 1767 83 BXRH-24G1000-G-8x 90 350 17.1 6.0 662 596 111 500 17.7 8.9 922 830 104 700 18.3 12.8 1240 1116 97 880 18.9 16.6 1522 1369 91 960 19.1 18.3 1637 1474 89 1200 19.7 23.6 1964 1767 83 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRH-24H1000-B-8x 97 175 34.2 6.0 561 505 94 250 35.3 8.8 781 702 88 350 36.6 12.8 1050 945 82 440 37.8 16.6 1288 1160 77 480 38.2 18.3 1387 1248 76 600 39.5 23.7 1663 1497 70 BXRH-24H1000-G-8x 97 350 17.1 6.0 561 505 94 500 17.7 8.9 781 702 88 700 18.3 12.8 1050 945 82 880 18.9 16.6 1288 1160 77 960 19.1 18.3 1387 1248 76 1200 19.7 23.6 1663 1497 70 BXRH-27E1000-B-8x 80 175 34.2 6.0 903 813 151 250 35.3 8.8 1257 1131 142 350 36.6 12.8 1691 1522 132 440 37.8 16.6 2075 1867 125 480 38.2 18.4 2233 2010 122 600 39.5 23.7 2678 2410 113 BXRH-27E1000-G-8x 80 350 17.1 6.0 903 813 151 500 17.7 8.8 1257 1131 142 700 18.3 12.8 1691 1522 132 880 18.9 16.6 2075 1867 125 960 19.1 18.4 2233 2010 122 1200 19.7 23.7 2678 2410 113 BXRH-27G1000-B-8x 90 175 34.2 6.0 745 671 124 250 35.3 8.8 1037 933 117 350 36.6 12.8 1395 1256 109 440 37.8 16.6 1712 1541 103 480 38.2 18.4 1842 1658 100 600 39.5 23.7 2209 1988 93 BXRH-27G1000-G-8x 90 350 17.1 6.0 745 671 124 500 17.7 8.8 1037 933 117 700 18.3 12.8 1395 1256 109 880 18.9 16.6 1712 1541 103 960 19.1 18.4 1842 1658 100 1200 19.7 23.7 2209 1988 93 BXRH-27G10H0-B-8x 90 175 34.2 6.0 774 696 129 250 35.3 8.8 1076 968 122 350 36.6 12.8 1448 1303 113 440 37.8 16.6 1777 1599 107 480 38.2 18.4 1912 1721 104 600 39.5 23.7 2293 2064 97 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRH-27G10H0-G-8x 90 350 17.1 6.0 774 696 129 500 17.7 8.8 1076 968 122 700 18.3 12.8 1448 1303 113 880 18.9 16.6 1777 1599 107 960 19.1 18.4 1912 1721 104 1200 19.7 23.7 2293 2064 97 BXRH-27H1000-B-8x 97 175 34.2 6.0 661 595 110 250 35.3 8.8 919 827 104 350 36.6 12.8 1237 1113 97 440 37.8 16.6 1517 1365 91 480 38.2 18.4 1633 1470 89 600 39.5 23.7 1958 1762 83 BXRH-27H1000-G-8x 97 350 17.1 6.0 661 595 110 500 17.7 8.8 919 827 104 700 18.3 12.8 1237 1113 97 880 18.9 16.6 1517 1365 91 960 19.1 18.4 1633 1470 89 1200 19.7 23.7 1958 1762 83 BXRH-30E1000-B-8x 80 175 34.2 6.0 960 864 160 250 35.3 8.8 1335 1202 151 350 36.6 12.8 1797 1617 140 440 37.8 16.6 2204 1984 133 480 38.2 18.4 2372 2135 129 600 39.5 23.7 2845 2561 120 BXRH-30E1000-G-8x 80 350 17.1 6.0 960 864 160 500 17.7 8.8 1335 1202 151 700 18.3 12.8 1797 1617 140 880 18.9 16.6 2204 1984 133 960 19.1 18.4 2372 2135 129 1200 19.7 23.7 2845 2561 120 BXRH-30G1000-B-8x 90 175 34.2 6.0 779 701 130 250 35.3 8.8 1084 976 123 350 36.6 12.8 1459 1313 114 440 37.8 16.6 1790 1611 108 480 38.2 18.4 1926 1733 105 600 39.5 23.7 2310 2079 97 BXRH-30G1000-G-8x 90 350 17.1 6.0 779 701 130 500 17.7 8.8 1084 976 123 700 18.3 12.8 1459 1313 114 880 18.9 16.6 1790 1611 108 960 19.1 18.4 1926 1733 105 1200 19.7 23.7 2310 2079 97 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRH-30G10H0-B-8x 90 175 34.2 6.0 813 732 136 250 35.3 8.8 1131 1018 128 350 36.6 12.8 1522 1370 119 440 37.8 16.6 1867 1681 112 480 38.2 18.4 2010 1809 110 600 39.5 23.7 2410 2169 102 BXRH-30G10H0-G-8x 90 350 17.1 6.0 813 732 136 500 17.7 8.8 1131 1018 128 700 18.3 12.8 1522 1370 119 880 18.9 16.6 1867 1681 112 960 19.1 18.4 2010 1809 110 1200 19.7 23.7 2410 2169 102 BXRH-30H1000-B-8x 97 175 34.2 6.0 706 635 118 250 35.3 8.8 982 884 111 350 36.6 12.8 1321 1189 103 440 37.8 16.6 1621 1459 98 480 38.2 18.4 1744 1570 95 600 39.5 23.7 2092 1883 88 BXRH-30H1000-G-8x 97 350 17.1 6.0 706 635 118 500 17.7 8.8 982 884 111 700 18.3 12.8 1321 1189 103 880 18.9 16.6 1621 1459 98 960 19.1 18.4 1744 1570 95 1200 19.7 23.7 2092 1883 88 BXRH-35E1000-B-9x 80 175 34.2 6.0 982 884 164 250 35.3 8.8 1367 1230 155 350 36.6 12.8 1839 1655 144 440 37.8 16.6 2256 2031 136 480 38.2 18.4 2428 2185 132 600 39.5 23.7 2912 2621 123 BXRH-35E1000-G-9x 80 350 17.1 6.0 982 884 164 500 17.7 8.8 1367 1230 155 700 18.3 12.8 1839 1655 144 880 18.9 16.6 2256 2031 136 960 19.1 18.4 2428 2185 132 1200 19.7 23.7 2912 2621 123 BXRH-35G1000-B-8x 90 175 34.2 6.0 807 727 135 250 35.3 8.8 1123 1011 127 350 36.6 12.8 1512 1360 118 440 37.8 16.6 1854 1669 112 480 38.2 18.4 1996 1796 109 600 39.5 23.7 2393 2154 101 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRH-35G1000-G-8x 90 350 17.1 6.0 807 727 135 500 17.7 8.8 1123 1011 127 700 18.3 12.8 1512 1360 118 880 18.9 16.6 1854 1669 112 960 19.1 18.4 1996 1796 109 1200 19.7 23.7 2393 2154 101 BXRH-35H1000-B-8x 97 175 34.2 6.0 726 653 121 250 35.3 8.8 1009 908 114 350 36.6 12.8 1358 1222 106 440 37.8 16.6 1666 1500 100 480 38.2 18.4 1793 1614 98 600 39.5 23.7 2151 1936 91 BXRH-35H1000-G-8x 97 350 17.1 6.0 726 653 121 500 17.7 8.8 1009 908 114 700 18.3 12.8 1358 1222 106 880 18.9 16.6 1666 1500 100 960 19.1 18.4 1793 1614 98 1200 19.7 23.7 2151 1936 91 BXRH-40E1000-B-8x 80 175 34.2 6.0 988 889 165 250 35.3 8.8 1375 1237 156 350 36.6 12.8 1850 1665 144 440 37.8 16.6 2269 2042 137 480 38.2 18.4 2442 2198 133 600 39.5 23.7 2929 2636 124 BXRH-40E1000-G-8x 80 350 17.1 6.0 988 889 165 500 17.7 8.8 1375 1237 156 700 18.3 12.8 1850 1665 144 880 18.9 16.6 2269 2042 137 960 19.1 18.4 2442 2198 133 1200 19.7 23.7 2929 2636 124 BXRH-40G1000-B-8x 90 175 34.2 6.0 824 742 138 250 35.3 8.8 1147 1032 130 350 36.6 12.8 1543 1389 120 440 37.8 16.6 1893 1704 114 480 38.2 18.4 2038 1834 111 600 39.5 23.7 2444 2199 103 BXRH-40G1000-G-8x 90 350 17.1 6.0 824 742 138 500 17.7 8.8 1147 1032 130 700 18.3 12.8 1543 1389 120 880 18.9 16.6 1893 1704 114 960 19.1 18.4 2038 1834 111 1200 19.7 23.7 2444 2199 103 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRH-40H1000-B-8x 97 175 34.2 6.0 745 671 124 250 35.3 8.8 1037 933 117 350 36.6 12.8 1395 1256 109 440 37.8 16.6 1712 1541 103 480 38.2 18.4 1842 1658 100 600 39.5 23.7 2209 1988 93 BXRH-40H1000-G-8x 97 350 17.1 6.0 745 671 124 500 17.7 8.8 1037 933 117 700 18.3 12.8 1395 1256 109 880 18.9 16.6 1712 1541 103 960 19.1 18.4 1842 1658 100 1200 19.7 23.7 2209 1988 93 BXRH-50E1001-B-8x 80 175 34.2 6.0 998 898 166 250 35.3 8.8 1389 1249 158 350 36.6 12.8 1869 1682 146 440 37.8 16.6 2292 2062 138 480 38.2 18.4 2466 2220 134 600 39.5 23.7 2958 2662 125 BXRH-50E1001-G-8x 80 350 17.1 6.0 998 898 166 500 17.7 8.8 1389 1249 158 700 18.3 12.8 1869 1682 146 880 18.9 16.6 2292 2062 138 960 19.1 18.4 2466 2220 134 1200 19.7 23.7 2958 2662 125 BXRH-50G1001-B-8x 90 175 34.2 6.0 824 742 138 250 35.3 8.8 1147 1032 130 350 36.6 12.8 1543 1389 120 440 37.8 16.6 1893 1704 114 480 38.2 18.4 2038 1834 111 600 39.5 23.7 2444 2199 103 BXRH-50G1001-G-8x 90 350 17.1 6.0 824 742 138 500 17.7 8.8 1147 1032 130 700 18.3 12.8 1543 1389 120 880 18.9 16.6 1893 1704 114 960 19.1 18.4 2038 1834 111 1200 19.7 23.7 2444 2199 103 BXRH-57E1001-B-8x 80 175 34.2 6.0 960 864 160 250 35.3 8.8 1335 1202 151 350 36.6 12.8 1797 1617 140 440 37.8 16.6 2204 1984 133 480 38.2 18.4 2372 2135 129 600 39.5 23.7 2845 2561 120 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRH-57E1001-G-8x 80 350 17.1 6.0 960 864 160 500 17.7 8.8 1335 1202 151 700 18.3 12.8 1797 1617 140 880 18.9 16.6 2204 1984 133 960 19.1 18.4 2372 2135 129 1200 19.7 23.7 2845 2561 120 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Electrical Characteristics

Table 5: Electrical Characteristics Part Number Drive Current (mA) Forward Voltage Pulsed, Tc = 25ºC (V) 1, 2, 3, 8 Typical Coefficient of Forward Voltage4 ∆Vf/∆Tc (mV/ºC) Typical Thermal Resistance Junction to Case5,6 Rj-c (ºC/W) Driver Selection Voltages7 (V) Minimum Typical Maximum Vf Min. Hot Tc = 105ºC (V) Vf Max. Cold Tc = -40ºC (V) BXRH-xxx10xx-B-8x BXRH-xxx10xx-G-8x Notes for Table 5: 1. Parts are tested in pulsed conditions, Tc = 25°C. Pulse width is 10ms. 2. Voltage minimum and maximum are provided for reference only and are not a guarantee of performance. 3. Bridgelux maintains a tester tolerance of ± 0.10V on forward voltage measurements. 4. Typical coefficient of forward voltage tolerance is ± 0.1mV for nominal current. 5. Thermal resistance values are based from test data of a 3000K 80 CRI product. 6. Thermal resistance value was calculated using total electrical input power; optical power was not subtracted from input power. The thermal interface material used during testing is not included in the thermal resistance value. 7. Vf min hot and max cold values are provided as reference only and are not guaranteed by test. These values are provided to aid in driver design and selection over the operating range of the product. 8. This product has been designed and manufactured per IEC 62031:2018. This product has passed dielectric withstand voltage testing at 500 V. The working voltage designated for the insulation is 50V d.c. The maximum allowable voltage across the array must be determined in the end product application.

Table 6: Eye Safety Risk Group (RG) Classifications Part Number Drive Current (mA) CCT1,4 2700K/3000K2 4000K3 BXRH-xxx10xx-B-8x

285 RG1 RG1

350 RG1 RG2

600 RG2 RG2

570 RG1 RG1

700 RG1 RG2

1200 RG2 RG2

Notes for Table 6: 1. Eye safety classification for the use of Bridgelux V Series HD LED arrays is in accordance with specification IEC/TR 62778: Application of IEC 62471 for the assessment of blue light hazard to light sources and luminaires. 2. For products classified as RG2 at 3000K, Ethr= 2670 lx. 3. For products classified as RG2 at 4000K, Ethr= 1760 lx. 4. Please contact your Bridgelux sales representative for Ethr values at specific drive currents and CCTs not listed.

LED Junction Temperature (Tj) 125°C Storage Temperature -40°C to +105°C Operating Case Temperature1 (Tc) 105°C Soldering Temperature2 350°C or lower for a maximum of 6 seconds BXRH-xxx10xx-B-8x BXRH-xxx10xx-G-8x Maximum Drive Current3 600 mA 1200 mA Maximum Peak Pulsed Drive Current4 680 mA 1360 mA Maximum Reverse Voltage5 -60V -30V Notes for Table 7: 1. For IEC 62717 requirement, please consult your Bridgelux sales representative. 2. Refer to Bridgelux Application Note AN101: Handling and Assembly of Bridgelux V Series LED Arrays. 3. Arrays may be driven at higher currents however lumen maintenance may be reduced and warranty will not apply. 4. Bridgelux recommends a maximum duty cycle of 10% and pulse width of 20 ms when operating LED Arrays at maximum peak pulsed current specified. Maximum peak pulsed currents indicate values where LED Arrays can be driven without catastrophic failures. 5. Light emitting diodes are not designed to be driven in reverse voltage and will not produce light under this condition. Maximum rating provided for reference only. Table 7: Maximum Ratings

Figure 7: Typical DC ccy Shift vs. Case Temperature Figure 8: Derating Curve Performance Curves -0.0060 -0.0050 -0.0040 -0.0030 -0.0020 -0.0010 0.0000 0.0010 0 20 40 60 80 100 120 ccy shift Case Temperature (Tc) Notes for Figure 7: 1. Bridgelux does not recommend driving high power LEDs at low currents. Doing so may produce unpredictable results. Pulse width modulation (PWM) is recommended for dimming effects. 2. Characteristics shown for 3000K and 90 CRI. 200 400 600 800 1,000 1,200 1,400 0 20 40 60 80 100 120 Drive Current (mA) Case Temperature (Tc) BXRH-xxx100x-B-8x BXRH-xxx100x-G-8x

Figure 13: Drawing for V6 HD LED Array Notes for Figure 13: 1. Drawings are not to scale. 2. Drawing dimensions are in millimeters. 3. Solder pads are labeled “+” and “-“ to denote positive and negative polarity, respectively. 4. Unless otherwise specified, tolerances are ±0.1mm. 5. Refer to Application Notes AN101 for product handling, mounting and heat sink recommendations. 6. The optical center of the LED Array is nominally defined by the mechanical center of the array to a tolerance of ± 0.2mm. 7. Bridgelux maintains a flatness of 0.10mm across the mounting surface of the array.

Bin Code 2200K 2400K 2700K 3000K 3500K 4000K ANSI Bin (for reference only) (2100K-2300K) (2300K-2500K) (2580K - 2870K) (2870K - 3220K) (3220K - 3710K) (3710K - 4260K) 83 (3 SDCM) (2207K-2309K) (2336K-2454K) (2651K - 2794K) (2968K - 3136K) (3369K - 3586K) (3851K - 4130K) 82 (2 SDCM) (2224K-2291K) (2355K-2433K) (2674K - 2769K) (2995K - 3107K) (3404K - 3548K) (3895K - 4081K) Table 8: Warm and Neutral White xy Bin Coordinates and Associated Typical CCT Figure 14: Warm and Neutral White Test Bins in xy Color Space Note: Pulsed Test Conditions, Tc = 25°C Note for Table 8-9: 1. Bridgelux maintains a tolerance of +/- 0.007 on x and y color coordinates in the CIE 1931 color Space. Bin Code 5000K 5700K ANSI Bin (for reference only) (4745K - 5311K) (5312K - 6022K) 84 (4 SDCM) (4801K - 5282K) (5395K- 5970K) 83 (3 SDCM) (4835K - 5215K) (5460K- 5891K) Center Point (x,y) (0.3447, 0.3553) (0.3287, 0.3417) Table 9: Cool White xy Bin Coordinates and Associated Typical CCT (product is hot targeted to Tc = 85°C Note: Pulsed Test Conditions, Tc = 85°C Figure 15: Cool White Test Bins in xy Color Space 0.3 0.31 0.32 0.33 0.34 0.35 0.36 0.37 0.38 0.39 Y X

4 SDCM

3 SDCM

Figure 16: V6 HD Packaging Tube Notes for Figure 16: 1. Each tube holds 35 V6 HD COB arrays. 2. One tube is sealed in an anti-static bag. Four bags are placed in a shipping box. Depending on quantities ordered, a bigger shipping box, containing four boxes may be used to ship products. 3. Each bag and box is to be labeled as shown above. shipping box are 58.7 x 13.3 x 7.9 cm BXRH-30E1000-B-83 480

Figure 17: V Series HD Product Labeling Bridgelux COB arrays have laser markings on the back side of the substrate to help with product identification. In addition to the product identification markings, Bridgelux COB arrays also contain markings for internal Bridgelux manufacturing use only. The image below shows which markings are for customer use and which ones are for Bridgelux internal use only. The Bridgelux internal manufacturing markings are subject to change without notice, however these will not impact the form, function or performance of the COB array. Customer Use- 2D Barcode Scannable barcode provides product part number and other Bridgelux internal production information. Customer Use- Product part number 30E1000B 83 Internal Bin Code

Bridgelux has developed a comprehensive set of application notes and design resources to assist customers in successfully designing with the V Series product family of LED array products. For all available application notes visit www.bridgelux.com. Optical Source Models Optical source models and ray set files are available for all Bridgelux products. For a list of available formats, visit www.bridgelux.com. MINOR PRODUCT CHANGE POLICY The rigorous qualification testing on products offered by Bridgelux provides performance assurance. Slight cosmetic changes that do not affect form, fit, or function may occur as Bridgelux continues product optimization. CAUTION: CHEMICAL EXPOSURE HAZARD Exposure to some chemicals commonly used in luminaire manufacturing and assembly can cause damage to the LED array. Please consult Bridgelux CAUTION: RISK OF BURN Do not touch the V Series HD LED array during operation. Allow the array to cool for a sufficient period of time before handling. The V Series HD LED array may reach elevated temperatures such that could burn skin when touched. 3D CAD Models Three dimensional CAD models depicting the product outline of all Bridgelux V Series HD LED arrays are available in both IGS and STEP formats. Please contact your Bridgelux sales representative for assistance. LM80 LM80 testing has been completed and the LM80 report is now available. Please contact your Bridgelux sales rep- resentatives for LM-80 report. CAUTION CONTACT WITH LIGHT EMITTING SURFACE (LES) Avoid any contact with the LES. Do not touch the LES of the LED array or apply stress to the LES (yellow phosphor resin area). Contact may cause damage to the LED array. Optics and reflectors must not be mounted in contact with the LES (yellow phosphor resin area). STANDARD TEST CONDITIONS Unless otherwise stated, array testing is performed at the nominal drive current.

About Bridgelux: Bridging Light and Life™

46410 Fremont Boulevard

Fremont, CA 94538 USA Tel (925) 583-8400 www.bridgelux.com At Bridgelux, we help companies, industries and people experience the power and possibility of light. Since 2002, we’ve designed LED solutions that are high performing, energy efficient, cost effective and easy to integrate. Our focus is on light’s impact on human behavior, delivering products that create better environments, experiences and returns—both experiential and financial. And our patented technology drives new platforms for commercial and industrial luminaires. For more information about the company, please visit bridgelux.com twitter.com/Bridgelux facebook.com/Bridgelux youtube.com/user/Bridgelux linkedin.com/company/bridgelux-inc-_2 WeChat ID: BridgeluxInChina © 2025 Bridgelux, Inc. All rights reserved. Product specifications are subject to change without notice. Bridgelux, the Bridgelux stylized logo design, Vero, V Series and V Series HD are registered trademarks, and Decor Series is a trademark of Bridgelux, Inc. All other trademarks are the property of their respective owners. Bridgelux Gen 8 V6 HD Array Series Product Data Sheet DS407 Rev. E (10/2025)