Vero® SE Series is a revolutionary light source system that integrates Bridgelux’s seventh generation COB technology with poke-in connectivity enabling solder-free installation. Vero SE LED light sources streamline assembly processes, lower manufacturing cost, simplify luminaire design, improve light quality and increase design flexibility. Vero SE is available in four different light emitting surface (LES) configurations that operate reliably over a broad current range. With Vero SE, secondary connector and holder components are not required, allowing for rapid integration of arrays into fixtures and an efficient field replaceable solution. Vero SE arrays deliver increased lumen density for improved beam control and precision lighting with 2 and 3 SDCM color control standards for clean and consistent uniform lighting. Bridgelux Décor Series is our state of the art color line designed specifically for premium applications, producing unmatched LED light quality with brilliant color-rendering options and offer pleasing and inspiring lighting palettes. Bridgelux Décor Series color points are available on Vero® SE Series, Vero® Series, V Series™ and V Series™ HD. Décor Series Class A is based on human response testing, providing color points with a combined GAI and CRI metric. Décor Series™ Ultra products provide a high CRI of 97 and typical R9 value of 98, which emphasizes the reds and color tones to which the human eye is most receptive - perfect for the most luxurious retail shops and world renowned museums. Décor Series Ultra is designed as a replacement for halogen lamps Décor Series™ Food products offer color points developed to address the unique requirements of the food, grocery, and restaurant industries. Highlighting the distinctive colors and nuanced patterns found in meats and breads, the Décor Series Food products are a must have for any butcher counter or bakery. Décor Series ™ Entertainment products provide color points developed specifically for the healthcare and entertainment industries. The 5600K cool white color point combined with a CRI of 90 or 97 provides the bright white required by these industries. Décor Series™ Street and Landmark is designed to be a direct replacement for high pressure sodium lamps. Vero SE

Features

  • Poke-in connectivity
  • Efficacy of 170 lm/W typical
  • Lumen output performance ranges from 5,368 to 37,173 lumens
  • Broad range of CCT options from 1750K to 6500K
  • CRI options: minimum 65, 70, 80, and 90
  • Color control: 2 and 3 SDCM for 2700K-4000K CCT
  • Reliable operation at up to 2X nominal drive current
  • Radial die pattern and improved lumen density
  • Top side part number markings
  • No exposed solder pads or electrical connections
  • V f bin code backside marking Benefits
  • Poke-in connectivity enables solderless, connector free installation
  • Broad application coverage for interior and exterior lighting
  • Flexibility for application driven lighting design requirements
  • High quality, true color reproduction
  • Uniform consistent white light
  • Flexibility in design optimization
  • Enhanced ease of use and assembly
  • Ability to configure multiple arrays in series and parallel reduces customer driver cost
  • Improved inventory management and quality control

Vero SE 29 is the largest form factor in the product family of next generation solid state light sources. In addition to delivering the performance and light quality required for many lighting applications, Vero SE incorporates several features to simplify the design integration and manufacturing process, accelerate time to market and reduce system costs. Please visit www.bridgelux.com for more information on the Vero SE Series family of products. Product Nomenclature The part number designation for Bridgelux Vero SE LED arrays is explained as follows: 1 2 3 4 – 5 6 7 8 9 10 11 – 12 – 13 14 – 15 16 Product Family CCT Bin Options 2 = 2 SDCM 3 = 3 SDCM 4 = 4 SDCM CRI B = 65 CRI min. C = 70 CRI min. E = 80 CRI min. G = 90 CRI min. A = Class A Array Configuration 17 = 1,750K 20 = 2,000K 25 = 2,500K 27 = 2,700K 30 = 3,000K 35 = 3,500K 40 = 4,000K 50 = 5,000K 56 = 5,600K 57 = 5,700K 65 = 6,500K BXRC – 30 E 10K 0 – C – 7 3 – SE Color Targeting Designator 0 = Cold Targeted 1 = Hot Targeted Gen. 7 Nominal CCT Flux Indicator 10Kx = 10,000 lm Special Edition Mounting holes Polarity indication marks simplify manufacturing operator instructions 2D Bar code provides full manufacturing traceability Dual poke-in connectivity Wire release mechanisms x4 Tc Measurement point Radial die configuration improves lumen density and beam control Test ports for probing Top side part number marking improves inventory management and outgoing Optic mounting holes

The following product configurations are available: Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 Tc = 25ºC (lm) Minimum Pulsed Flux6,7 Tc = 25ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-17E10K0-B-7x-SE 1750 80 1800 8590 7731 52.0 93.6 92 BXRC-17E10K0-C-7x-SE 1750 80 1710 10891 9802 69.4 118.7 92 BXRC-17E10K0-D-7x-SE 1750 80 2100 7246 6522 37.6 79.0 92 BXRC-20B10K1-C-7x-SE 2000 65 1710 18585 16727 69.4 118.7 157 BXRC-20B10K1-D-7x-SE 2000 65 2100 12366 11129 37.6 79.0 157 BXRC-25E10K0-B-7x-SE 2500 80 1800 14285 12856 52.0 93.6 153 BXRC-25E10K0-C-7x-SE 2500 80 1710 18112 16301 69.4 118.7 153 BXRC-25E10K0-D-7x-SE 2500 80 2100 12051 10846 37.6 79.0 153 BXRC-27E10K0-B-7x-SE 2700 80 1800 14939 13445 52.0 93.6 160 BXRC-27E10K0-C-7x-SE 2700 80 1710 18940 17046 69.4 118.7 160 BXRC-27E10K0-D-7x-SE 2700 80 2100 12602 11342 37.6 79.0 160 BXRC-27G1KH0-B-7x-SE 2700 90 1800 12791 11512 52.0 93.6 137 BXRC-27G1KH0-C-7x-SE 2700 90 1710 16218 14596 69.4 118.7 137 BXRC-27G1KH0-D-7x-SE 2700 90 2100 10790 9711 37.6 79.0 137 BXRC-27G10K0-B-7x-SE 2700 90 1800 12324 11092 52.0 93.6 132 BXRC-27G10K0-C-7x-SE 2700 90 1710 15626 14063 69.4 118.7 132 BXRC-27G10K0-D-7x-SE 2700 90 2100 10397 9357 37.6 79.0 132 BXRC-27H10K0-D-7x-SE 2700 97 2100 9215 8294 37.6 79.0 117 BXRC-30C10K1-B-7x-SE 3000 70 1800 16619 14957 52.0 93.6 178 BXRC-30C10K1-C-7x-SE 3000 70 1710 21071 18964 69.4 118.7 178 BXRC-30C10K1-D-7x-SE 3000 70 2100 14020 12618 37.6 79.0 178 BXRC-30E10K0-B-7x-SE10 3000 80 1800 15872 14285 52.0 93.6 170 BXRC-30E10K0-C-7x-SE10 3000 80 1710 20124 18112 69.4 118.7 170 BXRC-30E10K0-D-7x-SE10 3000 80 2100 13390 12051 37.6 79.0 170 BXRC-30G1KH0-B-7x-SE 3000 90 1800 13445 12100 52.0 93.6 144 BXRC-30G1KH0-C-7x-SE 3000 90 1710 17046 15342 69.4 118.7 144 BXRC-30G1KH0-D-7x-SE 3000 90 2100 11342 10208 37.6 79.0 144 BXRC-30G10K0-B-7x-SE 3000 90 1800 12885 11596 52.0 93.6 138 BXRC-30G10K0-C-7x-SE 3000 90 1710 16336 14702 69.4 118.7 138 BXRC-30G10K0-D-7x-SE 3000 90 2100 10869 9782 37.6 79.0 138 BXRC-30H10K0-D-7x-SE 3000 97 2100 9845 8861 37.6 79.0 125 BXRC-30A10K1-B-7x-SE8,9 3000 93 1800 11577 10420 52.0 93.6 124 BXRC-30A10K1-C-7x-SE8,9 3000 93 1710 14679 13211 69.4 118.7 124 BXRC-30A10K1-D-7x-SE8,9 3000 93 2100 9767 8790 37.6 79.0 124 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test. 8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance. 10. SKUs meet DLC premium (Outdoor Mid Output) requirements under certain system level conditions.

Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) (continued) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 Tc = 25ºC (lm) Minimum Pulsed Flux6,7 Tc = 25ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-35E10K0-B-7x-SE10 3500 80 1800 16246 14621 52.0 93.6 174 BXRC-35E10K0-C-7x-SE10 3500 80 1710 20598 18538 69.4 118.7 174 BXRC-35E10K0-D-7x-SE10 3500 80 2100 13705 12334 37.6 79.0 174 BXRC-35G10K0-B-7x-SE 3500 90 1800 13351 12016 52.0 93.6 143 BXRC-35G10K0-C-7x-SE 3500 90 1710 16928 15235 69.4 118.7 143 BXRC-35G10K0-D-7x-SE 3500 90 2100 11263 10137 37.6 79.0 143 BXRC-35A10K1-B-7x-SE8,9 3500 93 1800 12324 11092 52.0 93.6 132 BXRC-35A10K1-C-7x-SE8,9 3500 93 1710 15626 14063 69.4 118.7 132 BXRC-35A10K1-D-7x-SE8,9 3500 93 2100 10397 9357 37.6 79.0 132 BXRC-40C10K1-B-7x-SE 4000 70 1800 17086 15377 52.0 93.6 183 BXRC-40C10K1-C-7x-SE 4000 70 1710 21663 19497 69.4 118.7 183 BXRC-40C10K1-D-7x-SE 4000 70 2100 14414 12972 37.6 79.0 183 BXRC-40E10K0-B-7x-SE10 4000 80 1800 16339 14705 52.0 93.6 175 BXRC-40E10K0-C-7x-SE10 4000 80 1710 20716 18644 69.4 118.7 175 BXRC-40E10K0-D-7x-SE10 4000 80 2100 13783 12405 37.6 79.0 175 BXRC-40G10K0-B-7x-SE 4000 90 1800 13631 12268 52.0 93.6 146 BXRC-40G10K0-C-7x-SE 4000 90 1710 17283 15555 69.4 118.7 146 BXRC-40G10K0-D-7x-SE 4000 90 2100 11499 10349 37.6 79.0 146 BXRC-40H10K0-D-7x-SE 4000 97 2100 10397 9357 37.6 79.0 132 BXRC-40A10K1-B-7x-SE8,9 4000 93 1800 13351 12016 52.0 93.6 143 BXRC-40A10K1-C-7x-SE8,9 4000 93 1710 16928 15235 69.4 118.7 143 BXRC-40A10K1-D-7x-SE8,9 4000 93 2100 11263 10137 37.6 79.0 143 BXRC-50C10K1-B-7x-SE10 5000 70 1800 17179 15461 52.0 93.6 184 BXRC-50C10K1-C-7x-SE10 5000 70 1710 21781 19603 69.4 118.7 184 BXRC-50C10K1-D-7x-SE10 5000 70 2100 14492 13043 37.6 79.0 184 BXRC-50E10K1-B-7x-SE10 5000 80 1800 16526 14873 52.0 93.6 177 BXRC-50E10K1-C-7x-SE10 5000 80 1710 20953 18858 69.4 118.7 177 BXRC-50E10K1-D-7x-SE10 5000 80 2100 13941 12547 37.6 79.0 177 BXRC-50G10K1-B-7x-SE 5000 90 1800 14285 12856 52.0 93.6 153 BXRC-50G10K1-C-7x-SE 5000 90 1710 18112 16301 69.4 118.7 153 BXRC-50G10K1-D-7x-SE 5000 90 2100 12051 10846 37.6 79.0 153 BXRC-56G10K0-B-7x-SE 5600 80 1800 14378 12941 52.0 93.6 154 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test. 8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance. 10. SKUs meet DLC premium (Outdoor Mid Output) requirements under certain system level conditions.

Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) (continued) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 Tc = 25ºC (lm) Minimum Pulsed Flux6,7 Tc = 25ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-56G10K0-C-7x-SE 5600 80 1710 18230 16407 69.4 118.7 154 BXRC-56G10Kx-D-7x-SE 5600 80 2100 12129 10916 37.6 79.0 154 BXRC-56H10K0-D-7x-SE 5600 97 2100 10948 9853 37.6 79.0 139 BXRC-57C10K1-B-7x-SE 5700 70 1800 16713 15041 52.0 93.6 179 BXRC-57C10K1-C-7x-SE 5700 70 1710 21190 19071 69.4 118.7 179 BXRC-57C10K1-D-7x-SE 5700 70 2100 14099 12689 37.6 79.0 179 BXRC-57E10K1-B-7x-SE 5700 80 1800 15872 14285 52.0 93.6 170 BXRC-57E10K1-C-7x-SE 5700 80 1710 20124 18112 69.4 118.7 170 BXRC-57E10K1-D-7x-SE 5700 80 2100 13390 12051 37.6 79.0 170 BXRC-65C10K1-B-7x-SE 6500 70 1800 16713 15041 52.0 93.6 179 BXRC-65C10K1-C-7x-SE 6500 70 1710 21190 19071 69.4 118.7 179 BXRC-65C10K1-D-7x-SE 6500 70 2100 14099 12689 37.6 79.0 179 BXRC-65E10K1-B-7x-SE 6500 80 1800 16059 14453 52.0 93.6 172 BXRC-65E10K1-C-7x-SE 6500 80 1710 20361 18325 69.4 118.7 172 BXRC-65E10K1-D-7x-SE 6500 80 2100 13547 12192 37.6 79.0 172 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test. 8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance. 10. SKUs meet DLC premium (Outdoor Mid Output) requirements under certain system level conditions.

Table 2: Selection Guide, Stabilized DC Performance (Tc = 70°C) 7,8 Notes for Table 2: 1. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 2. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance. 3. CRI Values are specified as typical. 4. Drive current is referred to as nominal drive current. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 8. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at specified temperature. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 9. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. Part Number Nominal CCT1 (K) GAI2 CRI3 Nominal Drive Current4 (mA) Typical DC Flux5,6 Tc = 70ºC (lm) Minimum DC Flux6,9 Tc = 70ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-30A10K1-B-7x-SE 3000 80 93 1800 10767 9690 50.9 91.6 118 BXRC-30A10K1-C-7x-SE 3000 80 93 1710 13651 12286 67.9 116.1 118 BXRC-30A10K1-D-7x-SE 3000 80 93 2100 9083 8175 36.8 77.3 118 BXRC-35A10K1-B-7x-SE 3500 80 93 1800 11462 10315 50.9 91.6 125 BXRC-35A10K1-C-7x-SE 3500 80 93 1710 14532 13079 67.9 116.1 125 BXRC-35A10K1-D-7x-SE 3500 80 93 2100 9669 8702 36.8 77.3 125 BXRC-40A10K1-B-7x-SE 4000 80 93 1800 12417 11175 50.9 91.6 136 BXRC-40A10K1-C-7x-SE 4000 80 93 1710 15743 14169 67.9 116.1 136 BXRC-40A10K1-D-7x-SE 4000 80 93 2100 10475 9427 36.8 77.3 136

Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85ºC (lm) Minimum DC Flux6 Tc = 85ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-17E10K0-B-7x-SE 1750 80 1800 7731 6958 50.7 91.2 85 BXRC-17E10K0-C-7x-SE 1750 80 1710 9802 8821 68.1 116.4 84 BXRC-17E10K0-D-7x-SE 1750 80 2100 6522 5869 36.6 76.8 85 BXRC-20B10K1-C-7x-SE 2000 65 1710 16727 15054 68.1 116.4 144 BXRC-20B10K1-D-7x-SE 2000 65 2100 11129 10016 36.6 76.8 145 BXRC-25E10K0-B-7x-SE 2500 80 1800 12856 11571 50.7 91.2 141 BXRC-25E10K0-C-7x-SE 2500 80 1710 16301 14671 68.1 116.4 140 BXRC-25E10K0-D-7x-SE 2500 80 2100 10846 9761 36.6 76.8 141 BXRC-27E10K0-B-7x-SE 2700 80 1800 13445 12100 50.7 91.2 147 BXRC-27E10K0-C-7x-SE 2700 80 1710 17046 15342 68.1 116.4 146 BXRC-27E10K0-D-7x-SE 2700 80 2100 11342 10208 36.6 76.8 148 BXRC-27G1KH0-B-7x-SE 2700 90 1800 11512 10361 50.7 91.2 126 BXRC-27G1KH0-C-7x-SE 2700 90 1710 14596 13136 68.1 116.4 125 BXRC-27G1KH0-D-7x-SE 2700 90 2100 9711 8740 36.6 76.8 127 BXRC-27G10K0-B-7x-SE 2700 90 1800 11092 9983 50.7 91.2 122 BXRC-27G10K0-C-7x-SE 2700 90 1710 14063 12657 68.1 116.4 121 BXRC-27G10K0-D-7x-SE 2700 90 2100 9357 8421 36.6 76.8 122 BXRC-27H10K0-D-7x-SE 2700 97 2100 8294 7464 36.6 76.9 108 BXRC-30C10K1-B-7x-SE 3000 70 1800 14957 13462 50.7 91.2 164 BXRC-30C10K1-C-7x-SE 3000 70 1710 18964 17068 68.1 116.4 163 BXRC-30C10K1-D-7x-SE 3000 70 2100 12618 11356 36.6 76.8 164 BXRC-30E10K0-B-7x-SE 3000 80 1800 14285 12856 50.7 91.2 157 BXRC-30E10K0-C-7x-SE 3000 80 1710 18112 16301 68.1 116.4 156 BXRC-30E10K0-D-7x-SE 3000 80 2100 12051 10846 36.6 76.8 157 BXRC-30G1KH0-B-7x-SE 3000 90 1800 12100 10890 50.7 91.2 133 BXRC-30G1KH0-C-7x-SE 3000 90 1710 15342 13808 68.1 116.4 132 BXRC-30G1KH0-D-7x-SE 3000 90 2100 10208 9187 36.6 76.8 133 BXRC-30G10K0-B-7x-SE 3000 90 1800 11596 10436 50.7 91.2 127 BXRC-30G10K0-C-7x-SE 3000 90 1710 14702 13232 68.1 116.4 126 BXRC-30G10K0-D-7x-SE 3000 90 2100 9782 8804 36.6 76.8 127 BXRC-30H10K0-D-7x-SE 3000 97 2100 8861 7975 36.6 76.8 115 BXRC-30A10K1-B-7x-SE7,8 3000 93 1800 10420 9378 50.7 91.2 114 BXRC-30A10K1-C-7x-SE7,8 3000 93 1710 13211 11890 68.1 116.4 113 BXRC-30A10K1-D-7x-SE7,8 3000 93 2100 8790 7911 36.6 76.8 114 Notes for Table 3: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance.

Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 (continued) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85ºC (lm) Minimum DC Flux6 Tc = 85ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-35E10K0-B-7x-SE 3500 80 1800 14621 13159 50.7 91.2 160 BXRC-35E10K0-C-7x-SE 3500 80 1710 18538 16684 68.1 116.4 159 BXRC-35E10K0-D-7x-SE 3500 80 2100 12334 11101 36.6 76.8 161 BXRC-35G10K0-B-7x-SE 3500 90 1800 12016 10815 50.7 91.2 132 BXRC-35G10K0-C-7x-SE 3500 90 1710 15235 13712 68.1 116.4 131 BXRC-35G10K0-D-7x-SE 3500 90 2100 10137 9123 36.6 76.8 132 BXRC-35A10K1-B-7x-SE7,8 3500 93 1800 11092 9983 50.7 91.2 122 BXRC-35A10K1-C-7x-SE7,8 3500 93 1710 14063 12657 68.1 116.4 121 BXRC-35A10K1-D-7x-SE7,8 3500 93 2100 9357 8421 36.6 76.8 122 BXRC-40C10K1-B-7x-SE 4000 70 1800 15377 13840 50.7 91.2 169 BXRC-40C10K1-C-7x-SE 4000 70 1710 19497 17547 68.1 116.4 167 BXRC-40C10K1-D-7x-SE 4000 70 2100 12972 11675 36.6 76.8 169 BXRC-40E10K0-B-7x-SE 4000 80 1800 14705 13235 50.7 91.2 161 BXRC-40E10K0-C-7x-SE 4000 80 1710 18644 16780 68.1 116.4 160 BXRC-40E10K0-D-7x-SE 4000 80 2100 12405 11165 36.6 76.8 162 BXRC-40G10K0-B-7x-SE 4000 90 1800 12268 11041 50.7 91.2 135 BXRC-40G10K0-C-7x-SE 4000 90 1710 15555 13999 68.1 116.4 134 BXRC-40G10K0-D-7x-SE 4000 90 2100 10349 9314 36.6 76.8 135 BXRC-40H10K0-D-7X-SE 4000 97 2100 9357 8421 36.6 76.8 122 BXRC-40A10K1-B-7x-SE7,8 4000 93 1800 12016 10815 50.7 91.2 132 BXRC-40A10K1-C-7x-SE7,8 4000 93 1710 15235 13712 68.1 116.4 131 BXRC-40A10K1-D-7x-SE7,8 4000 93 2100 10137 9123 36.6 76.8 132 BXRC-50C10K1-B-7x-SE 5000 70 1800 15461 13915 50.7 91.2 170 BXRC-50C10K1-C-7x-SE 5000 70 1710 19603 17643 68.1 116.4 168 BXRC-50C10K1-D-7x-SE 5000 70 2100 13043 11739 36.6 76.8 170 BXRC-50E10K1-B-7x-SE 5000 80 1800 14873 13386 50.7 91.2 163 BXRC-50E10K1-C-7x-SE 5000 80 1710 18858 16972 68.1 116.4 162 BXRC-50E10K1-D-7x-SE 5000 80 2100 12547 11292 36.6 76.8 163 BXRC-50G10K1-B-7x-SE 5000 90 1800 12856 11571 50.7 91.2 141 BXRC-50G10K1-C-7x-SE 5000 90 1710 16301 14671 68.1 116.4 140 BXRC-50G10K1-D-7x-SE 5000 90 2100 10846 9761 36.6 76.8 141 BXRC-56G10K1-B-7x-SE 5600 80 1800 12941 11646 50.7 91.2 142 BXRC-56G10K1-C-7x-SE 5600 80 1710 16407 14766 68.1 116.4 141 BXRC-56G10Kx-D-7x-SE 5600 80 2100 10916 9825 36.6 76.8 142 BXRC-56H10K0-D-7x-SE 5600 97 2100 9853 8868 36.6 76.8 128 Notes for Table 3: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance.

Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 (continued) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85ºC (lm) Minimum DC Flux6 Tc = 85ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-57C10K1-B-7x-SE 5700 70 1800 15041 13537 50.7 91.2 165 BXRC-57C10K1-C-7x-SE 5700 70 1710 19071 17164 68.1 116.4 164 BXRC-57C10K1-D-7x-SE 5700 70 2100 12689 11420 36.6 76.8 165 BXRC-57E10K1-B-7x-SE 5700 80 1800 14285 12856 50.7 91.2 157 BXRC-57E10K1-C-7x-SE 5700 80 1710 18112 16301 68.1 116.4 156 BXRC-57E10K1-D-7x-SE 5700 80 2100 12051 10846 36.6 76.8 157 BXRC-65C10K1-B-7x-SE 6500 70 1800 15041 13537 50.7 91.2 165 BXRC-65C10K1-C-7x-SE 6500 70 1710 19071 17164 68.1 116.4 164 BXRC-65C10K1-D-7x-SE 6500 70 2100 12689 11420 36.6 76.8 165 BXRC-65E10K1-B-7x-SE 6500 80 1800 14453 13008 50.7 91.2 158 BXRC-65E10K1-C-7x-SE 6500 80 1710 18325 16492 68.1 116.4 157 BXRC-65E10K1-D-7x-SE 6500 80 2100 12192 10973 36.6 76.8 159 Notes for Table 3: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance.

European Product Registry for Energy Labeling The European Product Registry for Energy Labeling (EPREL) is defined in the EU Regulation 2017/1369 to provide import- ant energy efficiency information to consumers. Together with Energy Labeling Regulation ELR (EU) 2019/2015 which was amended by regulation (EU) 2021/340 for energy labelling of light sources, manufacturers are required to declare an ener- gy class based on key technical specifications from each of their product and register it in an open data base managed by EPREL It is now a legal requirement for a vendor of light sources to upload information about their products into the EPREL database before placing these products on the market in the EU. Table 4 below provides a list of part numbers that are in compliance with ELR and are currently listed in the EPREL data- base. At Bridgelux, we are fully committed to supplying products that are compliant with pertinent laws, rules, and obligation imposed by relevant government bodies including the European Energy Labeling regulation. Customers can use these products with full confidence for any projects that fall under the ELR. Table 4: Part numbers registered in European Product Registry for Energy Labeling PART NUMBER1 CCT (K) CRI Current2 (mA) Vf (V) Useful flux3 (Φuse) at 85C (lm) Pow- er (W) Efficacy (lm/W) Energy efficiency class4 Regis- tration No URL to Product Information Sheet in EPREL Database Notes for Table 4: 1. All device listed here must be disposed as e-waste upon its end of life according to local country guideline in each country. 2. For information on performance values at alternative drive conditions. please refer to the Product Selection Guide, Absolute Maximum Rating Table and Performance Curves in this data sheet. 3. For a definition of useful luminous flux (ΦΦuse), please see the ELR regulations at https:/ /tinyurl.com/4b6zvt4m. 4. EPREL requires an arrow symbol containing the letter of the energy efficiency class to be displayed. on technical promotional material. Refer to this energy efficiency class column for specific energy efficiency class on each part number.

European Product Registry for Energy Labeling Table 4: Part numbers registered in European Product Registry for Energy Labeling (Continued) PART NUMBER1 CCT (K) CRI Current2 (mA) Vf (V) Useful flux3 (Φuse) at 85C (lm) Pow- er (W) Efficacy (lm/W) Energy efficiency class4 Regis- tration No URL to Product Information Sheet in EPREL Database Notes for Table 4: 1. All device listed here must be disposed as e-waste upon its end of life according to local country guideline in each country. 2. For information on performance values at alternative drive conditions. please refer to the Product Selection Guide, Absolute Maximum Rating Table and Performance Curves in this data sheet. 3. For a definition of useful luminous flux (ΦΦuse), please see the ELR regulations at https:/ /tinyurl.com/4b6zvt4m. 4. EPREL requires an arrow symbol containing the letter of the energy efficiency class to be displayed. on technical promotional material. Refer to this energy efficiency class column for specific energy efficiency class on each part number.

European Product Registry for Energy Labeling Table 4: Part numbers registered in European Product Registry for Energy Labeling (Continued) PART NUMBER1 CCT (K) CRI Current2 (mA) Vf (V) Useful flux3 (Φuse) at 85C (lm) Pow- er (W) Efficacy (lm/W) Energy efficiency class4 Regis- tration No URL to Product Information Sheet in EPREL Database Notes for Table 4: 1. All device listed here must be disposed as e-waste upon its end of life according to local country guideline in each country. 2. For information on performance values at alternative drive conditions. please refer to the Product Selection Guide, Absolute Maximum Rating Table and Performance Curves in this data sheet. 3. For a definition of useful luminous flux (ΦΦuse), please see the ELR regulations at https:/ /tinyurl.com/4b6zvt4m. 4. EPREL requires an arrow symbol containing the letter of the energy efficiency class to be displayed. on technical promotional material. Refer to this energy efficiency class column for specific energy efficiency class on each part number.

Performance at Commonly Used Drive Currents Vero SE LED arrays are tested to the specifications shown using the nominal drive currents in Table 1. Vero SE may also be driven at other drive currents dependent on specific application design requirements. The performance at any drive current can be derived from the current vs. voltage characteristics shown in Figures 1, 2 & 3 and the flux vs. current characteristics shown in Figures 4, 5 & 6. The performance at commonly used drive currents is summarized in Table 5. Table 5: Product Performance at Commonly Used Drive Currents Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-17E10K0-B-7x-SE 80 900 49.6 44.7 4459 4070 100 1200 50.5 60.6 5871 5337 97 1800 52.0 93.6 8590 7731 92 2700 54.1 146.1 12382 11042 85 3600 55.8 201.0 15847 13963 79 BXRC-17E10K0-C-7x-SE 80 855 66.2 56.6 5651 4646 100 1140 67.3 76.7 7454 6099 97 1710 69.4 118.7 10891 9802 92 2565 72.1 185.0 15678 12430 85 3420 74.4 254.6 20063 15514 79 BXRC-17E10K0-D-7x-SE 80 1050 35.4 37.2 3661 3010 98 1400 36.2 50.6 4841 3962 96 2100 37.6 79.0 7246 6522 92 3150 39.5 124.4 10581 8389 85 4200 41.2 172.9 13826 10692 80 BXRC-20B10K1-C-7x-SE 65 855 66.2 56.6 9643 7929 170 1140 67.3 76.7 12720 10408 166 1710 69.4 118.7 18585 16727 157 2565 72.1 185.0 26755 21212 145 3420 74.4 254.6 34237 26475 134 BXRC-20B10K1-D-7x-SE 65 1050 35.4 37.2 6247 5137 168 1400 36.2 50.6 8262 6760 163 2100 37.6 79.0 12366 11129 157 3150 39.5 124.4 18057 14316 145 4200 41.2 172.9 23595 18246 136 BXRC-25E10K0-B-7x-SE 80 900 49.6 44.7 7416 6769 166 1200 50.5 60.6 9764 8876 161 1800 52.0 93.6 14285 12856 153 2700 54.1 146.1 20592 18364 141 3600 55.8 201.0 26355 23221 131 BXRC-25E10K0-C-7x-SE 80 855 66.2 56.6 9397 7727 166 1140 67.3 76.7 12396 10143 162 1710 69.4 118.7 18112 16301 153 2565 72.1 185.0 26073 20672 141 3420 74.4 254.6 33365 25801 131 BXRC-25E10K0-D-7x-SE 80 1050 35.4 37.2 6088 5006 164 1400 36.2 50.6 8052 6588 159 2100 37.6 79.0 12051 10846 153 3150 39.5 124.4 17597 13951 142 4200 41.2 172.9 22994 17781 133 Notes for Table 5: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Performance at Commonly Used Drive Currents Notes for Table 5: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. Table 5: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-27E10K0-B-7x-SE 80 900 49.6 44.7 7755 7079 174 1200 50.5 60.6 10211 9282 169 1800 52.0 93.6 14939 13445 160 2700 54.1 146.1 21534 19204 147 3600 55.8 201.0 27561 24283 137 BXRC-27E10K0-C-7x-SE 80 855 66.2 56.6 9827 8081 174 1140 67.3 76.7 12963 10607 169 1710 69.4 118.7 18940 17046 160 2565 72.1 185.0 27266 21617 147 3420 74.4 254.6 34891 26981 137 BXRC-27E10K0-D-7x-SE 80 1050 35.4 37.2 6366 5235 171 1400 36.2 50.6 8420 6890 166 2100 37.6 79.0 12602 11342 160 3150 39.5 124.4 18402 14590 148 4200 41.2 172.9 24046 18595 139 BXRC-27G1KH0-B-7x-SE 90 900 49.6 44.7 6640 6061 149 1200 50.5 60.6 8743 7948 144 1800 52.0 93.6 12791 11512 137 2700 54.1 146.1 18438 16444 126 3600 55.8 201.0 23599 20792 117 BXRC-27G1KH0-C-7x-SE 90 855 66.2 56.6 8415 6919 149 1140 67.3 76.7 11100 9082 145 1710 69.4 118.7 16218 14596 137 2565 72.1 185.0 23346 18510 126 3420 74.4 254.6 29876 23103 117 BXRC-27G1KH0-D-7x-SE 90 1050 35.4 37.2 5451 4482 146 1400 36.2 50.6 7210 5899 142 2100 37.6 79.0 10790 9711 137 3150 39.5 124.4 15757 12492 127 4200 41.2 172.9 20589 15922 119 BXRC-27G10K0-B-7x-SE 90 900 49.6 44.7 6398 5840 143 1200 50.5 60.6 8424 7658 139 1800 52.0 93.6 12324 11092 132 2700 54.1 146.1 17765 15843 122 3600 55.8 201.0 22738 20033 113 BXRC-27G10K0-C-7x-SE 90 855 66.2 56.6 8108 6667 143 1140 67.3 76.7 10695 8751 139 1710 69.4 118.7 15626 14063 132 2565 72.1 185.0 22494 17834 122 3420 74.4 254.6 28785 22260 113 BXRC-27G10K0-D-7x-SE 90 1050 35.4 37.2 5252 4319 141 1400 36.2 50.6 6946 5684 137 2100 37.6 79.0 10397 9357 132 3150 39.5 124.4 15181 12036 122 4200 41.2 172.9 19838 15340 115

Notes for Table 5: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. Table 5: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-27H10K0-D-7x-SE 97 1050 35.4 37.2 4655 3828 125 1400 36.2 50.6 6157 5038 122 2100 37.6 79.0 9215 8294 117 3150 39.5 124.4 13456 10669 108 4200 41.2 172.9 17584 13597 102 BXRC-30C10K1-B-7x-SE 70 900 49.6 44.7 9441 8984 211 1200 50.5 60.6 11999 11069 198 1800 52.0 93.6 16619 14957 178 2700 54.1 146.1 23576 20277 161 3600 55.8 201.0 29551 24831 147 BXRC-30C10K1-C-7x-SE 70 855 66.2 56.6 10933 8990 193 1140 67.3 76.7 14422 11800 188 1710 69.4 118.7 21071 18964 178 2565 72.1 185.0 30333 24049 164 3420 74.4 254.6 38817 30017 152 BXRC-30C10K1-D-7x-SE 70 1050 35.4 37.2 7083 5824 190 1400 36.2 50.6 9367 7665 185 2100 37.6 79.0 14020 12618 178 3150 39.5 124.4 20472 16231 165 4200 41.2 172.9 26751 20686 155 BXRC-30E10K0-B-7x-SE 80 900 49.6 44.7 8240 7521 184 1200 50.5 60.6 10849 9862 179 1800 52.0 93.6 15872 14285 170 2700 54.1 146.1 22879 20404 157 3600 55.8 201.0 29283 25801 146 BXRC-30E10K0-C-7x-SE 80 855 66.2 56.6 10442 8586 185 1140 67.3 76.7 13773 11270 180 1710 69.4 118.7 20124 18112 170 2565 72.1 185.0 28970 22969 157 3420 74.4 254.6 37072 28668 146 BXRC-30E10K0-D-7x-SE 80 1050 35.4 37.2 6764 5562 182 1400 36.2 50.6 8946 7320 177 2100 37.6 79.0 13390 12051 170 3150 39.5 124.4 19552 15501 157 4200 41.2 172.9 25549 19757 148 BXRC-30G1KH0-B-7x-SE 90 900 49.6 44.7 6979 6371 156 1200 50.5 60.6 9190 8354 152 1800 52.0 93.6 13445 12100 144 2700 54.1 146.1 19380 17284 133 3600 55.8 201.0 24805 21855 123 BXRC-30G1KH0-C-7x-SE 90 855 66.2 56.6 8845 7273 156 1140 67.3 76.7 11667 9546 152 1710 69.4 118.7 17046 15342 144 2565 72.1 185.0 24539 19456 133 3420 74.4 254.6 31402 24283 123 Performance at Commonly Used Drive Currents

Performance at Commonly Used Drive Currents Notes for Table 5: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. Table 5: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-30G1KH0-D-7x-SE 90 1050 35.4 37.2 5730 4711 154 1400 36.2 50.6 7578 6201 150 2100 37.6 79.0 11342 10208 144 3150 39.5 124.4 16562 13131 133 4200 41.2 172.9 21641 16735 125 BXRC-30G10K0-B-7x-SE 90 900 49.6 44.7 6689 6106 150 1200 50.5 60.6 8807 8006 145 1800 52.0 93.6 12885 11596 138 2700 54.1 146.1 18573 16564 127 3600 55.8 201.0 23771 20944 118 BXRC-30G10K0-C-7x-SE 90 855 66.2 56.6 8476 6970 150 1140 67.3 76.7 11181 9149 146 1710 69.4 118.7 16336 14702 138 2565 72.1 185.0 23517 18645 127 3420 74.4 254.6 30094 23271 118 BXRC-30G10K0-D-7x-SE 90 1050 35.4 37.2 5491 4515 148 1400 36.2 50.6 7262 5942 143 2100 37.6 79.0 10869 9782 138 3150 39.5 124.4 15872 12584 128 4200 41.2 172.9 20740 16038 120 BXRC-30H10K0-D-7x-SE 97 1050 35.4 37.2 4974 4090 134 1400 36.2 50.6 6578 5382 130 2100 37.6 79.0 9845 8861 125 3150 39.5 124.4 14376 11398 116 4200 41.2 172.9 18786 14527 109 BXRC-30A10K1-B-7x-SE 93 900 49.6 44.7 6010 5486 135 1200 50.5 60.6 7914 7193 131 1800 52.0 93.6 11577 10420 124 2700 54.1 146.1 16689 14883 114 3600 55.8 201.0 21360 18819 106 BXRC-30A10K1-C-7x-SE 93 855 66.2 56.6 7616 6262 135 1140 67.3 76.7 10046 8220 131 1710 69.4 118.7 14679 13211 124 2565 72.1 185.0 21131 16754 114 3420 74.4 254.6 27041 20910 106 BXRC-30A10K1-D-7x-SE 93 1050 35.4 37.2 4934 4057 133 1400 36.2 50.6 6525 5339 129 2100 37.6 79.0 9767 8790 124 3150 39.5 124.4 14261 11307 115 4200 41.2 172.9 18636 14411 108 BXRC-35E10K0-B-7x-SE 80 900 49.6 44.7 8434 7698 189 1200 50.5 60.6 11105 10094 183 1800 52.0 93.6 16246 14621 174 2700 54.1 146.1 23418 20884 160 3600 55.8 201.0 29972 26408 149

Performance at Commonly Used Drive Currents Notes for Table 5: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. Table 5: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-35E10K0-C-7x-SE 80 855 66.2 56.6 10687 8788 189 1140 67.3 76.7 14097 11535 184 1710 69.4 118.7 20598 18538 174 2565 72.1 185.0 29652 23509 160 3420 74.4 254.6 37944 29342 149 BXRC-35E10K0-D-7x-SE 80 1050 35.4 37.2 6923 5693 186 1400 36.2 50.6 9157 7492 181 2100 37.6 79.0 13705 12334 174 3150 39.5 124.4 20012 15866 161 4200 41.2 172.9 26150 20222 151 BXRC-35G10K0-B-7x-SE 90 900 49.6 44.7 6931 6327 155 1200 50.5 60.6 9126 8296 151 1800 52.0 93.6 13351 12016 143 2700 54.1 146.1 19246 17164 132 3600 55.8 201.0 24632 21703 123 BXRC-35G10K0-C-7x-SE 90 855 66.2 56.6 8783 7222 155 1140 67.3 76.7 11586 9480 151 1710 69.4 118.7 16928 15235 143 2565 72.1 185.0 24369 19321 132 3420 74.4 254.6 31184 24114 123 BXRC-35G10K0-D-7x-SE 90 1050 35.4 37.2 5690 4679 153 1400 36.2 50.6 7525 6158 149 2100 37.6 79.0 11263 10137 143 3150 39.5 124.4 16447 13039 132 4200 41.2 172.9 21491 16619 124 BXRC-35A10K1-B-7x-SE 93 900 49.6 44.7 6398 5840 143 1200 50.5 60.6 8424 7658 139 1800 52.0 93.6 12324 11092 132 2700 54.1 146.1 17765 15843 122 3600 55.8 201.0 22738 20033 113 BXRC-35A10K1-C-7x-SE 93 855 66.2 56.6 8108 6667 143 1140 67.3 76.7 10695 8751 139 1710 69.4 118.7 15626 14063 132 2565 72.1 185.0 22494 17834 122 3420 74.4 254.6 28785 22260 113 BXRC-35A10K1-D-7x-SE 93 1050 35.4 37.2 5252 4319 141 1400 36.2 50.6 6946 5684 137 2100 37.6 79.0 10397 9357 132 3150 39.5 124.4 15181 12036 122 4200 41.2 172.9 19838 15340 115 BXRC-40C10K1-B-7x-SE 70 900 49.6 44.7 8870 8096 199 1200 50.5 60.6 11679 10616 193 1800 52.0 93.6 17086 15377 183 2700 54.1 146.1 24629 21965 169 3600 55.8 201.0 31523 27774 157

Performance at Commonly Used Drive Currents Notes for Table 5: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. Table 5: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-40C10K1-C-7x-SE 70 855 66.2 56.6 11240 9242 199 1140 67.3 76.7 14827 12132 193 1710 69.4 118.7 21663 19497 183 2565 72.1 185.0 31185 24725 169 3420 74.4 254.6 39907 30860 157 BXRC-40C10K1-D-7x-SE 70 1050 35.4 37.2 7281 5987 196 1400 36.2 50.6 9630 7880 190 2100 37.6 79.0 14414 12972 183 3150 39.5 124.4 21047 16687 169 4200 41.2 172.9 27502 21267 159 BXRC-40E10K0-B-7x-SE 80 900 49.6 44.7 8482 7743 190 1200 50.5 60.6 11168 10152 184 1800 52.0 93.6 16339 14705 175 2700 54.1 146.1 23552 21004 161 3600 55.8 201.0 30145 26560 150 BXRC-40E10K0-C-7x-SE 80 855 66.2 56.6 10749 8838 190 1140 67.3 76.7 14179 11601 185 1710 69.4 118.7 20716 18644 175 2565 72.1 185.0 29822 23644 161 3420 74.4 254.6 38162 29511 150 BXRC-40E10K0-D-7x-SE 80 1050 35.4 37.2 6963 5725 187 1400 36.2 50.6 9209 7535 182 2100 37.6 79.0 13783 12405 175 3150 39.5 124.4 20127 15957 162 4200 41.2 172.9 26300 20338 152 BXRC-40G10K0-B-7x-SE 90 900 49.6 44.7 7076 6459 158 1200 50.5 60.6 9318 8470 154 1800 52.0 93.6 13631 12268 146 2700 54.1 146.1 19649 17524 135 3600 55.8 201.0 25149 22158 125 BXRC-40G10K0-C-7x-SE 90 855 66.2 56.6 8967 7374 158 1140 67.3 76.7 11829 9679 154 1710 69.4 118.7 17283 15555 146 2565 72.1 185.0 24880 19726 134 3420 74.4 254.6 31838 24620 125 BXRC-40G10K0-D-7x-SE 90 1050 35.4 37.2 5809 4777 156 1400 36.2 50.6 7683 6287 152 2100 37.6 79.0 11499 10349 146 3150 39.5 124.4 16792 13313 135 4200 41.2 172.9 21942 16967 127 BXRC-40H10K0-D-7x-SE 97 1050 35.4 37.2 5252 4319 141 1400 36.2 50.6 6946 5684 137 2100 37.6 79.0 10397 9357 132 3150 39.5 124.4 15181 12036 122 4200 41.2 172.9 19838 15340 115

Performance at Commonly Used Drive Currents Notes for Table 5: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. Table 5: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-40A10K1-B-7x-SE 93 900 49.6 44.7 6931 6327 155 1200 50.5 60.6 9126 8296 151 1800 52.0 93.6 13351 12016 143 2700 54.1 146.1 19246 17164 132 3600 55.8 201.0 24632 21703 123 BXRC-40A10K1-C-7x-SE 93 855 66.2 56.6 8783 7222 155 1140 67.3 76.7 11586 9480 151 1710 69.4 118.7 16928 15235 143 2565 72.1 185.0 24369 19321 132 3420 74.4 254.6 31184 24114 123 BXRC-40A10K1-D-73-SE 93 1050 35.4 37.2 5690 4679 153 1400 36.2 50.6 7525 6158 149 2100 37.6 79.0 11263 10137 143 3150 39.5 124.4 16447 13039 132 4200 41.2 172.9 21491 16619 124 BXRC-50C10K1-B-7x-SE 70 900 49.6 44.7 8918 8141 200 1200 50.5 60.6 11743 10674 194 1800 52.0 93.6 17179 15461 184 2700 54.1 146.1 24764 22085 170 3600 55.8 201.0 31695 27925 158 BXRC-50C10K1-C-7x-SE 70 855 66.2 56.6 11301 9293 200 1140 67.3 76.7 14908 12198 194 1710 69.4 118.7 21781 19603 184 2565 72.1 185.0 31356 24860 170 3420 74.4 254.6 40125 31028 158 BXRC-50C10K1-D-7x-SE 70 1050 35.4 37.2 7321 6020 197 1400 36.2 50.6 9683 7923 191 2100 37.6 79.0 14492 13043 184 3150 39.5 124.4 21162 16778 170 4200 41.2 172.9 27653 21384 160 BXRC-50E10K1-B-7x-SE 80 900 49.6 44.7 8579 7831 192 1200 50.5 60.6 11296 10268 187 1800 52.0 93.6 16526 14873 177 2700 54.1 146.1 23822 21245 163 3600 55.8 201.0 30489 26863 152 BXRC-50E10K1-C-7x-SE 80 855 66.2 56.6 10872 8939 192 1140 67.3 76.7 14341 11734 187 1710 69.4 118.7 20953 18858 177 2565 72.1 185.0 30163 23914 163 3420 74.4 254.6 38599 29848 152 BXRC-50E10K1-D-7x-SE 80 1050 35.4 37.2 7043 5791 189 1400 36.2 50.6 9315 7622 184 2100 37.6 79.0 13941 12547 177 3150 39.5 124.4 20357 16140 164 4200 41.2 172.9 26601 20570 154 x-SE

Performance at Commonly Used Drive Currents Notes for Table 5: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. Table 5: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-50G10K1-B-7x-SE 90 900 49.6 44.7 7416 6769 166 1200 50.5 60.6 9764 8876 161 1800 52.0 93.6 14285 12856 153 2700 54.1 146.1 20592 18364 141 3600 55.8 201.0 26355 23221 131 BXRC-50G10K1-C-7x-SE 90 855 66.2 56.6 9397 7727 166 1140 67.3 76.7 12396 10143 162 1710 69.4 118.7 18112 16301 153 2565 72.1 185.0 26073 20672 141 3420 74.4 254.6 33365 25801 131 BXRC-50G10K1-D-7x-SE 90 1050 35.4 37.2 6088 5006 164 1400 36.2 50.6 8052 6588 159 2100 37.6 79.0 12051 10846 153 3150 39.5 124.4 17597 13951 142 4200 41.2 172.9 22994 17781 133 BXRC-56G10K0-B-7x-SE 80 900 49.6 44.7 7464 6813 167 1200 50.5 60.6 9828 8934 162 1800 52.0 93.6 14378 12941 154 2700 54.1 146.1 20726 18484 142 3600 55.8 201.0 26527 23372 132 BXRC-56G10K0-C-7x-SE 80 855 66.2 56.6 9459 7778 167 1140 67.3 76.7 12477 10209 163 1710 69.4 118.7 18230 16407 154 2565 72.1 185.0 26243 20807 142 3420 74.4 254.6 33583 25969 132 BXRC-56G10K0-D-7x-SE 80 1050 35.4 37.2 6128 5038 165 1400 36.2 50.6 8104 6631 160 2100 37.6 79.0 12129 10916 154 3150 39.5 124.4 17712 14043 142 4200 41.2 172.9 23144 17897 134 BXRC-56H10K0-D-7x-SE 80 1050 35.4 37.2 5531 4548 149 1400 36.2 50.6 7315 5985 144 2100 37.6 79.0 10948 9853 139 3150 39.5 124.4 15987 12675 129 4200 41.2 172.9 20890 16154 121 BXRC-57C10K1-B-7x-SE 70 900 49.6 44.7 8676 7920 194 1200 50.5 60.6 11424 10384 189 1800 52.0 93.6 16713 15041 179 2700 54.1 146.1 24091 21485 165 3600 55.8 201.0 30834 27167 153 BXRC-57C10K1-C-7x-SE 70 855 66.2 56.6 10994 9040 194 1140 67.3 76.7 14503 11867 189 1710 69.4 118.7 21190 19071 179 2565 72.1 185.0 30504 24184 165 3420 74.4 254.6 39035 30185 153

Performance at Commonly Used Drive Currents Table 5: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-57C10K1-D-7x-SE 70 1050 35.4 37.2 7122 5856 191 1400 36.2 50.6 9420 7708 186 2100 37.6 79.0 14099 12689 179 3150 39.5 124.4 20587 16322 166 4200 41.2 172.9 26901 20803 156 BXRC-57E10K1-B-7x-SE 80 900 49.6 44.7 8240 7521 184 1200 50.5 60.6 10849 9862 179 1800 52.0 93.6 15872 14285 170 2700 54.1 146.1 22879 20404 157 3600 55.8 201.0 29283 25801 146 BXRC-57E10K1-C-7x-SE 80 855 66.2 56.6 10442 8586 185 1140 67.3 76.7 13773 11270 180 1710 69.4 118.7 20124 18112 170 2565 72.1 185.0 28970 22969 157 3420 74.4 254.6 37072 28668 146 BXRC-57E10K1-D-7x-SE 80 1050 35.4 37.2 6764 5562 182 1400 36.2 50.6 8946 7320 177 2100 37.6 79.0 13390 12051 170 3150 39.5 124.4 19552 15501 157 4200 41.2 172.9 25549 19757 148 BXRC-65C10K1-B-7x-SE 70 900 49.6 44.7 8676 7920 194 1200 50.5 60.6 11424 10384 189 1800 52.0 93.6 16713 15041 179 2700 54.1 146.1 24091 21485 165 3600 55.8 201.0 30834 27167 153 BXRC-65C10K1-C-7x-SE 70 855 66.2 56.6 10994 9040 194 1140 67.3 76.7 14503 11867 189 1710 69.4 118.7 21190 19071 179 2565 72.1 185.0 30504 24184 165 3420 74.4 254.6 39035 30185 153 BXRC-65C10K1-D-7x-SE 70 1050 35.4 37.2 7122 5856 191 1400 36.2 50.6 9420 7708 186 2100 37.6 79.0 14099 12689 179 3150 39.5 124.4 20587 16322 166 4200 41.2 172.9 26901 20803 156 BXRC-65E10K1-B-7x-SE 80 900 49.6 44.7 8337 7610 187 1200 50.5 60.6 10977 9978 181 1800 52.0 93.6 16059 14453 172 2700 54.1 146.1 23149 20644 158 3600 55.8 201.0 29628 26104 147 BXRC-65E10K1-C-7x-SE 80 855 66.2 56.6 10564 8687 187 1140 67.3 76.7 13935 11403 182 1710 69.4 118.7 20361 18325 172 2565 72.1 185.0 29311 23239 158 3420 74.4 254.6 37508 29005 147 Notes for Table 5: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Performance at Commonly Used Drive Currents Table 5: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-65E10K1-D-7x-SE 80 1050 35.4 37.2 6844 5627 184 1400 36.2 50.6 9051 7406 179 2100 37.6 79.0 13547 12192 172 3150 39.5 124.4 19782 15684 159 4200 41.2 172.9 25849 19989 149 Notes for Table 5: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Electrical Characteristics

Notes for Table 6: 1. Parts are tested in pulsed conditions, Tc = 25°C. Pulse width is 10ms. 2. Voltage minimum and maximum are provided for reference only and are not a guarantee of performance. 3. Bridgelux maintains a tester tolerance of ± 0.10V on forward voltage measurements. 4. Typical coefficient of forward voltage tolerance is ± 0.1mV for nominal current. 5. Thermal resistance values are based from test data of a 3000K 80 CRI product. 6. Thermal resistance value was calculated using total electrical input power; optical power was not subtracted from input power. The thermal interface material used during testing is not included in the thermal resistance value. 7. V f min hot and max cold values are provided as reference only and are not guaranteed by test. These values are provided to aid in driver design and selection over the operating range of the product. 8. This product has been designed and manufactured per IEC 62031:2014. This product has passed dielectric withstand voltage testing at 1160 V. The working voltage designated for the insulation is 80V d.c. The maximum allowable voltage across the array must be determined in the end product application. Table 6: Electrical Characteristics Part Number Drive Current (mA) Forward Voltage Pulsed, Tc = 25ºC (V) 1, 2, 3, 8 Typical Coefficient of Forward Voltage4 ∆Vf/∆Tc (mV/ºC) Typical Thermal Resistance Junction to Case5,6 Rj-c (ºC/W) Driver Selection Voltages7 (V) Minimum Typical Maximum Vf Min. Hot Tc = 105ºC (V) Vf Max. Cold Tc = -40ºC (V) BXRC-xxx10Kx-B-7x-SE BXRC-xxx10Kx-C-7x-SE BXRC-xxx10Kx-D-7x-SE

Table 7: Eye Safety Risk Group (RG) Classifications Notes for Table 7: 1. Eye safety classification for the use of Bridgelux Vero SE Series LED arrays is in accordance with specification IEC/TR 62778: Application of IEC 62471 for the assessment of blue light hazard to light sources and luminaires. 2. For products classified as RG2 at 4000K, Ethr= 1847.5 lx. 3. For products classified as RG2 at 5000K Ethr= 1315.8 lx. 4. For products classified as RG2 at 6500K, Ethr= 1124.5 lx. 5. Please contact your Bridgelux sales representative for Ethr values at specific drive currents and CCTs not listed. Part Number Drive Current 5 (mA) CCT1,5 2700K/3000K 4000K2 5000K3 6500K4 BXRC-xxx10Kx-B-7x-SE

1800 RG1 RG1 RG1 RG1

2700 RG1 RG1 RG2 RG2

3600 RG1 RG1 RG2 RG2

1710 RG1 RG1 RG1 RG2

2565 RG1 RG1 RG2 RG2

3420 RG1 RG2 RG2 RG2

2100 RG1 RG1 RG1 RG1

3150 RG1 RG1 RG1 RG2

4200 RG1 RG1 RG2 RG2

LED Junction Temperature (Tj) 150°C Storage Temperature -40°C to +105°C Operating Case Temperature1 (Tc) 105°C BXRC-xxx10Kx-B-7x-SE BXRC-xxx10Kx-C-7x-SE BXRC-xxx10Kx-D-7x-SE Maximum Drive Current3 3600mA 3420mA 4200mA Maximum Peak Pulsed Drive Current4 5140mA 4890mA 6000mA Maximum Reverse Voltage5 -90V -120V -65V Table 8: Maximum Ratings Notes for Table 8: 1. For IEC 62717 requirement, please consult your Bridgelux sales representative. 2. Refer to Bridgelux Application Note AN120: Assembly Considerations for Bridgelux Vero SE LED Arrays. 3. Arrays may be driven at higher currents however lumen maintenance may be reduced. 4. Bridgelux recommends a maximum duty cycle of 10% and pulse width of 20 ms when operating LED Arrays at maximum peak pulsed current specified. Maximum peak pulsed currents indicate values where LED Arrays can be driven without catastrophic failures. 5. Light emitting diodes are not designed to be driven in reverse voltage and will not produce light under this condition. Maximum rating provided for reference only.

Notes for Figure 17: 1. The maximum allowable drive current for the Vero 29D product is dependent on the operating case temperature. Please refer to the Product Feature Map (page 2) for the location of the Tc Point 2. LM-80 Max Drive Current must not be exceeded in order to meet LM-80 lifetime projections. 3. Lumen maintenance (L70) and lifetime predictions are valid for drive current and case temperature conditions used for LM-80 testing as included in the applicable LM-80 test report for these products. Contact your Bridgelux sales representative for LM-80 report. 3200 3400 3600 3800 4000 4200 4400 0 10 20 30 40 50 60 70 80 90 100 110 Drive Current (mA) Case Temperature (⁰C) Max Drive Current LM-80 Max Drive Current 3960 Figure 17: Vero SE 29D Drive Current Derating Curve

Figure 22: Drawing for Vero SE 29 LED Array Notes for Figure 22: 1. Drawings are not to scale. 2. Drawing dimensions are in millimeters. 3. Unless otherwise specified, tolerances are ± 0.15mm. 4. Mounting holes (2X) are for M3 screws. 5. Bridgelux recommends two tapped holes for mounting screws with 42.9 ± 0.10mm center-to-center spacing. 6. Screws with flat shoulders (pan, dome, button, round, truss, mushroom) provide optimal torque control. Do NOT use flat, countersink, or raised head screws. 7. The optical center of the LED Array is nominally defined by the mechanical center of the array to a tolerance of ± 0.2mm. 8. Bridgelux maintains a flatness of 0.10mm across the mounting surface of the array.

Figure 23: Graph of Warm and Neutral White Test Bins in xy Color Space Figure 24: Graph of Cool White Test Bins in xy Color Space Color Binning Information Bin Code 1750K 2500K 2700K 3000K1 3500K1 4000K1 ANSI Bin (for reference only) - - (2580K - 2870K) (2870K - 3220K) (3220K - 3710K) (3710K - 4260K) 73 (3 SDCM) - - (2651K - 2794K) (2968K - 3136K) (3369K - 3586K) (3851K - 4130K) 72 (2 SDCM) - - (2674K - 2769K) (2995K - 3107K) (3404K - 3548K) (3895K - 4081K) Table 9: Warm and Neutral White xy Bin Coordinates and Associated Typical CCT Bin Code 5000K 5600K1 5700K 6500K ANSI Bin (for reference only) (4745K - 5311K) (5310K - 6020K) (5312K - 6022K) (6022K - 7042K) 74 (4 SDCM) (4801K - 5282K) (5475K - 5830K) (5829K - 5481K) (6270K - 6765K) 73 (3 SDCM) (4835K - 5215K) (5490K - 5820K) (5490K - 5820K) (6250K - 6745K) Table 10: Cool White xy Bin Coordinates and Associated Typical CCT (product is hot targeted to Tc = 85°C) Note: Pulsed Test Conditions, Tc = 25°C Note: Pulsed Test Conditions, Tc = 25°C Note: Pulsed Test Conditions, Tc = 25°C Notes for Table 10: 1. Select configurations with a CCT of 5600K are available with center point targets at Tc = 85°C or Tc = 25°C. 2. Bridgelux maintains a tolerance of +/- 0.007 on x and y color coordinates in the CIE 1931 color Space. Notes for Table 9: 1. Color Binning information excludes Class A products. Please contact your Bridgelux Sales Representative for more information. 2. Bridgelux maintains a tolerance of +/- 0.007 on x and y color coordinates in the CIE 1931 color Space. 0.34 0.36 0.38 0.4 0.42 0.44 Y X

3 SDCM

4 SDCM

0.3 0.31 0.32 0.33 0.34 0.35 0.36 0.37 0.38 0.39 Y X

Figure 25: Drawing for Vero SE 29 Packaging Tray Notes for Figure 25: 1. Dimensions are in millimeters. 2. Drawings are not to scale.

Bridgelux has developed a comprehensive set of application notes and design resources to assist customers in successfully designing with the Vero product family of LED array products. For all available application notes visit www.bridgelux.com. Optical Source Models Optical source models and ray set files are available for all Bridgelux products. For a list of available formats, visit www.bridgelux.com. MINOR PRODUCT CHANGE POLICY The rigorous qualification testing on products offered by Bridgelux provides performance assurance. Slight cosmetic changes that do not affect form, fit, or function may occur as Bridgelux continues product optimization. CAUTION: CHEMICAL EXPOSURE HAZARD Exposure to some chemicals commonly used in luminaire manufacturing and assembly can cause damage to the LED array. Please consult Bridgelux CAUTION: RISK OF BURN Do not touch the Vero LED array during operation. Allow the array to cool for a sufficient period of time before handling. The Vero LED array may reach elevated temperatures such that could burn skin when touched. 3D CAD Models Three dimensional CAD models depicting the product outline of all Bridgelux Vero LED arrays are available in both IGS and STEP formats. Please contact your Bridgelux sales representative for assistance. LM80 LM80 testing has been completed and the LM80 report is now available. Please contact your Bridgelux sales representative for LM-80 report. CAUTION CONTACT WITH LIGHT EMITTING SURFACE (LES) Avoid any contact with the LES. Do not touch the LES of the LED array or apply stress to the LES (yellow phosphor resin area). Contact may cause damage to the LED array. Optics and reflectors must not be mounted in contact with the LES (yellow phosphor resin area). Optical devices may be mounted on the top surface of the plastic housing of the Vero LED array. Use the mechanical features of the LED array housing, edges and/or mounting holes to locate and secure optical devices as needed. STANDARD TEST CONDITIONS Unless otherwise stated, array testing is performed at the nominal drive current.

About Bridgelux: Bridging Light and Life™ © 2023 Bridgelux, Inc. All rights reserved. Product specifications are subject to change without notice. Bridgelux, the Bridgelux stylized logo design, Vero, V Series and V Series HD are registered trademarks, and Decor Series is a trademark of Bridgelux, Inc. All other trademarks are the property of their respective owners. Bridgelux Vero SE 29 Array Series Product Data Sheet DS123 Rev. Q (07/2023)

46410 Fremont Boulevard

Fremont, CA 94538 U.S.A. Tel (925) 583-8400 www.bridgelux.com At Bridgelux, we help companies, industries and people experience the power and possibility of light. Since 2002, we’ve designed LED solutions that are high performing, energy efficient, cost effective and easy to integrate. Our focus is on light’s impact on human behavior, delivering products that create better environments, experiences and returns—both experiential and financial. And our patented technology drives new platforms for commercial and industrial luminaires. For more information about the company, please visit bridgelux.com twitter.com/Bridgelux facebook.com/Bridgelux youtube.com/user/Bridgelux linkedin.com/company/bridgelux-inc-_2 WeChat ID: BridgeluxInChina