EB Series™ Gen 3 Thrive Product Data Sheet DS133 Lengths: 280mm, 560mm, 1120mm CRI: 98 Thrive CCTs: 2700K, 3000K, 3500K, 4000K, 5000K, 5700K, 6500K
Bridgelux EB Series Thrive modules are fully engineered devices that provide consistent thermal and optical performance on an engineered mechanical platform. The linear products incorporate several features to simplify design integration and assembly. Please visit www.bridgelux.com for more information on the EB Series family of products. Product Nomenclature The part number designation for Bridgelux EB Series Gen 3 Thrive is explained as follows: Nominal CCT 27 = 2700K 30 = 3000K 35 = 3500K 40 = 4000K 50 = 5000K 57 = 5700K 65 = 6500K 1 2 3 4 - 5 6 7 8 9 10 - 11 12 13 14 15 16 - 17 – 18 BXEB L0280Z 2000 C3C Product Family Module Version C = Gen 3 3 = 3 SDCM Flux Indicator 1000 = 1000 lm 2000 = 2000 lm 4000 = 4000 lm Module Configuration Nominal Dimensions L= Linear 0280 = 280 mm 0560 = 560 mm 1120 = 1120 mm Z= Zhaga compatible width (24 mm) 30 S CRI S = 98 (Thrive) – – – – Zhaga compatible mounting holes Re-usable connector Designed to comply with global safety standards for creepage and clearance distances Label containing part number and lot codes is attached on the front of the module where shown Multiple case temperature measurement points
Table 1: Product Performance at 480mA/960mA nominal (Tc = 25° C) Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. 2. Data is at nominal test current where temperature of center case temperature point Tc= 25° C. 3. Bridgelux maintains a ± 7% tolerance on typical flux data (typical SMD flux bins) Part Number Nominal CCT1 (K) Typical CRI Typical Flux2,3 (lm) Nominal Drive Current (mA) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXEB-L0280Z-27S1000-C-C3 2700 1185 480 20.3 9.7 122 BXEB-L0280Z-30S1000-C-C3 3000 1235 127 BXEB-L0280Z-35S1000-C-C3 3500 1345 138 BXEB-L0280Z-40S1000-C-C3 4000 1345 138 BXEB-L0280Z-50S1000-C-C3 5000 1345 138 BXEB-L0280Z-57S1000-C-C3 5700 1345 138 BXEB-L0280Z-65S1000-C-C3 6500 1345 138 BXEB-L0560Z-27S2000-C-C3 2700 2370 960 20.3 19.5 122 BXEB-L0560Z-30S2000-C-C3 3000 2470 127 BXEB-L0560Z-35S2000-C-C3 3500 2690 138 BXEB-L0560Z-40S2000-C-C3 4000 2690 138 BXEB-L0560Z-50S2000-C-C3 5000 2690 138 BXEB-L0560Z-57S2000-C-C3 5700 2690 138 BXEB-L0560Z-65S2000-C-C3 6500 2690 138 BXEB-L1120Z-27S4000-C-C3 2700 4740 960 40.6 39.0 122 BXEB-L1120Z-30S4000-C-C3 3000 4940 127 BXEB-L1120Z-35S4000-C-C3 3500 5380 138 BXEB-L1120Z-40S4000-C-C3 4000 5380 138 BXEB-L1120Z-50S4000-C-C3 5000 5380 138 BXEB-L1120Z-57S4000-C-C3 5700 5380 138 BXEB-L1120Z-65S4000-C-C3 6500 5380 138
Table 2: Product Performance at 350mA/700mA nominal (Tc = 25° C) Notes for Table 2: 1. Nominal CCT as defined by ANSI C78.377-2011. 2. Data is at nominal test current where temperature of center case temperature point Tc= 25° C. 3. Bridgelux maintains a ± 7% tolerance on typical flux data (typical SMD flux bins) Part Number Nominal CCT1 (K) Typical CRI Typical Flux2,3 (lm) Nominal Drive Current (mA) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXEB-L0280Z-27S1000-C-C3 2700 890 350 19.9 7.0 128 BXEB-L0280Z-30S1000-C-C3 3000 930 134 BXEB-L0280Z-35S1000-C-C3 3500 1010 145 BXEB-L0280Z-40S1000-C-C3 4000 1010 145 BXEB-L0280Z-50S1000-C-C3 5000 1010 145 BXEB-L0280Z-57S1000-C-C3 5700 1010 145 BXEB-L0280Z-65S1000-C-C3 6500 1010 145 BXEB-L0560Z-27S2000-C-C3 2700 1780 700 19.9 13.9 128 BXEB-L0560Z-30S2000-C-C3 3000 1860 134 BXEB-L0560Z-35S2000-C-C3 3500 2020 145 BXEB-L0560Z-40S2000-C-C3 4000 2020 145 BXEB-L0560Z-50S2000-C-C3 5000 2020 145 BXEB-L0560Z-57S2000-C-C3 5700 2020 145 BXEB-L0560Z-65S2000-C-C3 6500 2020 145 BXEB-L1120Z-27S4000-C-C3 2700 3560 700 39.8 27.8 128 BXEB-L1120Z-30S4000-C-C3 3000 3720 134 BXEB-L1120Z-35S4000-C-C3 3500 4040 145 BXEB-L1120Z-40S4000-C-C3 4000 4040 145 BXEB-L1120Z-50S4000-C-C3 5000 4040 145 BXEB-L1120Z-57S4000-C-C3 5700 4040 145 BXEB-L1120Z-65S4000-C-C3 6500 4040 145
Table 3: Average Spectral Difference & Color Rendering Notes for Table 3: 1. All values are typical measurements at Tsp=85C, with module drive current of 480mA (280mm) or 960mA (560mm/1120mm) 2. Bridgelux maintains a tolerance of ± 3 on Color Rendering Index R1-R15 measurements and TM-30 measurements 3. ASD (Average Spectral Difference) is a metric developed by Bridgelux that quantifies the naturalness of a light source by summing the differences between any SPD and a standardized natural light source SPD. For further information, please visit www.bridgelux.com/products/thrive and view the Bridgelux ASD White Paper. CCT ASD TM-30 CRI Rf Rg Ra R1 R2 R3 R4 R5 R6 R7 R8 R9 R10 R11 R12 R13 R14 R15 2700K 11% 96 100 98 97 98 99 96 96 94 98 98 95 96 93 92 96 99 99 3000K 10% 97 100 98 97 98 98 97 97 96 99 99 97 98 94 96 97 98 99 3500K 11% 97 101 98 99 98 95 98 98 97 98 97 92 94 97 93 99 96 98 4000K 9% 97 100 98 99 99 96 98 99 98 99 99 97 96 97 94 99 97 99 5000K 10% 97 101 98 98 98 100 97 98 97 97 98 96 98 99 90 98 99 96 5700K 9% 97 100 98 99 99 99 98 98 98 99 98 95 98 97 97 98 99 98 6500K 8% 97 100 98 99 99 99 99 99 99 99 99 97 98 99 98 99 99 99 Figure 1: 2700K TM-30 Color Sample Fidelity 100 CES01 CES03 CES05 CES07 CES09 CES11 CES13 CES15 CES17 CES19 CES21 CES23 CES25 CES27 CES29 CES31 CES33 CES35 CES37 CES39 CES41 CES43 CES45 CES47 CES49 CES51 CES53 CES55 CES57 CES59 CES61 CES63 CES65 CES67 CES69 CES71 CES73 CES75 CES77 CES79 CES81 CES83 CES85 CES87 CES89 CES91 CES93 CES95 CES97 CES99 Color Sample Fidelity (Rf,CESi) Color Evaluation Sample TM-30 Color Sample Fidelity The following seven figures show the 99 Color Evaluation Samples (CES) defined by TM-30 for each module CCT. These are typical measurements at Tsp=85C, with module drive current of 480mA (280mm) or 960mA (560mm/1120mm)
Electrical Characteristics
Table 4: Electrical Characteristics Part Number Drive Current (mA) Forward Voltage Tc2 = 25º C (V) 1, 2,3 Typical Coefficient of Forward Voltage4 ∆Vf/∆T (mV/º C) Driver Selection Voltages5 (V) Minimum Typical Maximum Vf Min, Hot Tc2 = 85º C (V) Vf Max, Cold Tc2 = -40º C (V) BXEB-L0280Z-xxS1000-C-C3 350 18.5 19.9 21.3 -8.5 18.0 21.8 BXEB-L0560Z-xxS2000-C-C3 700 18.5 19.9 21.3 -8.5 18.0 21.8 BXEB-L1120Z-xxS4000-C-C3 700 37.0 39.8 42.6 -17.0 36.0 43.7 Notes for Table 4: 1. Voltage minimum and maximum are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a tolerance of ± 0.1 V on forward voltage data. 3. This product has been designed and manufactured per IEC 62031:2018. The working voltage designated for the insulation is 60 V d.c. The maximum allow- able voltage across the module must be determined in the end product application. 4. Typical coefficient of forward voltage tolerance is ± 0.1 mV for nominal current. 5. Vf min hot and max cold values are provided as reference only and are not guaranteed. These values are provided to aid in driver design and selection over the operating range of the product.
Table 5: Maximum Ratings Parameter Maximum Rating Storage Temperature -40°C to +85°C Operating Case Temperature2 (Tc) 85°C Soldering Temperature 350°C or lower for a maximum of 5 seconds Maximum Reverse Voltage Modules are not designed to be driven in reverse bias BXEB-L0280Z-xxS1000-C-C3 BXEB-L0560Z-xxS2000-C-C3 BXEB-L1120Z-xxS4000-C-C3 Maximum Drive Current 960 mA 1920 mA 1920 mA Notes for Table 5 1. For IEC 62717 requirement, please consult your Bridgelux sales representative. 2. Lumen maintenance (L70) and lifetime predictions are valid for drive current and case temperature conditions used for LM-80 testing as included in the applicable LM-80 test report for the SMDs used in the modules. Contact your Bridgelux sales representatives for LM-80 report.
Figure 16: Typical Spatial Radiation Pattern Notes for Figure 16: 1. Typical viewing angle is 120⁰. 2. The viewing angle is defined as the off axis angle from the centerline where Iv is ½ of the peak value. 20% 40% 60% 80% 100% 120% -100 -80 -60 -40 -20 0 20 40 60 80 100 Relative Intensity Angle (°)
Figure 17: Typical Spectral Power Distribution 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 380 480 580 680 780 Relative Intensity Wavelength (nm) 2700K 3000K 3500K 4000K 5000K 5700K 6500K Note for Figure 17: 1. Color spectra measured at nominal current for TC = 65°C
Figure 21: 3 SDCM Color Bins in CIE 1931 xy Color Space Table 7: Bin Coordinates and Associated Typical CCT Notes for Table 7: 1. Color binning at solder point temperature Tsp of SMDs at 85°C. 2. Bridgelux maintains a tolerance of ± 0.007 on x and y color coordinates in the CIE 1931 color space. 0.30 0.32 0.34 0.36 0.38 0.40 0.42 0.44 CIE y CIE x CCT Color Consistency CIE Center Point (x, y) Corresponding CCT Range 2700K 3 SDCM (0.458, 0.410) 2651K - 2794K 3000K 3 SDCM (0.434, 0.403) 2968K - 3136K 3500K 3 SDCM (0.407, 0.392) 3369K - 3586K 4000K 3 SDCM (0.382, 0.380) 3851K - 4130K 5000K 3 SDCM (0.3445, 0.355) 4835K - 5215K 5700K 3 SDCM (0.329, 0.342) 5490K - 5820K 6500K 3 SDCM (0.312, 0.328) 6250K - 6745K
Figure 22: EB Series Packaging and Labeling Customer Use- 2D Barcode Scannable barcode provides product part number and other Bridgelux internal production information. EB Series Thrive 1ft 2000lm 960mA Box Parameter BXEB-L0280Z-xxS1000-C-C3 BXEB-L0560Z-xxS2000-C-C3 BXEB-L1120Z-xxS4000-C-C3 Module Quantity 200 100 100 Weight 7.9 kg 7.9 kg 15.6 kg Product Labeling Bridgelux EB Series modules contain a label on the front to help with product identification. In addition to the product identification markings, Bridgelux EB Series modules also contain markings for internal Bridgelux manufacturing use only. The image below shows which markings are for customer use and which ones are for Bridgelux internal use only. The Bridgelux internal manufacturing markings are subject to change without notice, however these will not impact the form, function or performance of the module. Table 8: Packaging Structure Note: This label & packaging diagram is for illustration only and may differ from actual product label and packaging for this product
Bridgelux has developed a comprehensive set of application notes and design resources to assist customers in successfully designing with the EB Series product family. For a list of resources under development, visit www.bridgelux.com. Optical Source Models Optical source models and ray set files are available for all Bridgelux products. For a list of available formats, visit www.bridgelux.com. MINOR PRODUCT CHANGE POLICY The rigorous qualification testing on products offered by Bridgelux provides performance assurance. Slight cosmetic changes that do not affect form, fit, or function may occur as Bridgelux continues product optimization. CAUTION: CHEMICAL EXPOSURE HAZARD Exposure to some chemicals commonly used in luminaire manufacturing and assembly can cause damage to the LED linear. Please consult Bridgelux Application Note for additional information. CAUTION: EYE SAFETY Eye safety classification for the use of Bridgelux EB Series is in accordance with IEC/TR62778: Application of IEC 62471 for the assessment of blue light hazard to light sources and luminaires. EB Series linears are classified as Risk Group 1 when operated at or below the maximum drive current. Please use appropriate precautions. It is important that employees working with LEDs are trained to use them safely. CAUTION: RISK OF BURN Do not touch the EB Series linears during operation. Allow the linear to cool for a sufficient period of time be- fore handling. The EB Series linears may reach elevated temperatures such that could burn skin when touched. 3D CAD Models Three dimensional CAD models depicting the product outline of all Bridgelux EB Series LED linears are available in both IGES and STEP formats. Please contact your Bridgelux sales representative for assistance. CAUTION CONTACT WITH LIGHT EMITTING SURFACE (LES) Avoid any contact with the LES. Do not touch the LES of the linear or apply stress to the LES (yellow phosphor resin area). Contact may cause damage to the linear. Optics and reflectors must not be mounted in con- tact with the LES (yellow phosphor resin area). Optical devices may be mounted on the top surface of the EB Series linear. Use the mechanical features of the linear housing, edges and/or mounting holes to locate and secure optical devices as needed. STANDARD TEST CONDITIONS Unless otherwise stated, linear testing is performed at the nominal drive current.
About Bridgelux: Bridging Light and Life™ © 2020 Bridgelux, Inc. All rights reserved. Product specifications are subject to change without notice. Bridgelux and the Bridgelux stylized logo design and Thrive are regis- tered trademarks of Bridgelux, Inc. EB Series and Bridging Light and Life are trademarks of Bridgelux, Inc. All other trademarks are the property of their respective owners. Bridgelux EB Series Gen 3 Thrive Data Sheet DS133 Rev. A (03/2025)
46430 Fremont Blvd
Fremont, CA 94538 USA Tel (925) 583-8400 Fax (925) 583-8401 www.bridgelux.com At Bridgelux, we help companies, industries and people experience the power and possibility of light. Since 2002, we’ve designed LED solutions that are high performing, energy efficient, cost effective and easy to integrate. Our focus is on light’s impact on human behavior, delivering products that create better environments, experiences and returns—both experiential and financial. And our patented technology drives new platforms for commercial and industrial luminaires. For more information about the company, please visit: bridgelux.com twitter.com/Bridgelux facebook.com/Bridgelux youtube.com/user/Bridgelux linkedin.com/company/bridgelux WeChat ID: BridgeluxInChina